Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

SU-E-J-49: Distal Edge Activity Fall Off Of Proton Therapy Beams

Purpose: To characterize and quantify the distal edge activity fall off, created in a phantom by a proton therapy beam Method and Materials: A 30x30x10cm polymethylmethacrylate phantom was irradiated with a proton therapy beam using different ranges and beams. The irradiation volume is approximated by a right circular cylinder of diameter 7.6cm and varying lengths. After irradiation, the phantom was scanned via a Philips Gemini Big Bore™ PET-CT for isotope activation. Varian Eclipse™ treatment planning system as well as ImageJ™ were used to analyze the resulting PET and CT scans. The region of activity within the phantom was longitudinally measured as a function of PET slice number. Dose estimations were made via Monte Carlo (GATE) simulation. Results: For both the spread out Bragg peak (SOBP) and the mono-energetic pristine Bragg peak proton beams, the proximal activation rise was steep: average slope −0.735 (average intensity/slice number) ± 0.091 (standard deviation) for the pristine beams and −1.149 ± 0.117 for the SOBP beams. In contrast, the distal fall offs were dissimilar. The distal fall off in activity for the pristine beams was fit well by a linear curve: R{sup 2} (Pierson Product) was 0.9968, 0.9955 and 0.9909 for the 13.5, 17.0 and 21.0cm range beams respectively. The good fit allows for a slope comparison between the different ranges. The slope varied as a function of range from 1.021 for the 13.5cm beam to 0.8407 (average intensity/slice number) for the 21.0cm beam. This dependence can be characterized: −0.0234(average intensity/slice number/cm range). For the SOBP beams, the slopes were significantly less and were also less linear: average slope 0.2628 ± 0.0474, average R{sup 2}=0.9236. Conclusion: The distal activation fall off edge for pristine proton beams was linear and steep. The corresponding quantities for SOBP beams were shallower and less linear. Philips has provided support for this work.

07 ISOTOPE AND RADIATION SOURCES↗

TH-E-BRE-06: Challenges in the Dosimetry of Flattening Filter Free Beams

Purpose: In current dosimetry protocols [AAPM TG51, IAEA TRS-389] the beam quality correction factor kQ and the water-to-air restricted mass collision stopping-power ratio SPR are related to beam quality specifiers %dd(10){sub x} respectively TPR{sub 20,10} Determining kQ and SPR using these regular beam quality specifiers for conventional accelerators (WFF) and flattening filter free accelerators (FFF) similarly could lead to systemic bias.The influence of the flattening filter on the relationship between various beam quality specifiers and SPR respectively k{sub Q} was studied using Monte Carlo simulations with realistic beam sources. Methods: All Monte Carlo simulations were performed using the BEAMnrc/EGSnrc code system. Radiation transport through nine linear accelerator heads modeled according to technical drawings given by the manufactures and a {sup 60} Co therapy source was simulated with BEAMnrc and then used as a radiation source for further simulations. FFF beam sources were implemented by removing the fattening filter from the WFF model. SPR was calculated applying the user code SPRRZnrc. The mean photon energy below the accelerator head and the mean energies of photons and electrons at the measuring point within the water phantom were calculated using FLURZnrc. Dose calculations within a small water voxel and the thimble ionization chamber PTW-31010 in a water depth of 10 cm were made using the egs-chamber code. Results: SPR and k{sub Q} as a function of fluence spectra based beam quality specifiers as well as conventional beam quality specifiers differ systematically between FFF and WFF beams. According to the results the specifier %dd(10){sub x} revealed the smallest deviation (max. 0.4%) between FFF and WFF beams. Conclusion: The results show that %dd(10){sub x} is an acceptable beam quality specifier for FFF beams. Nevertheless the results confirm the expected bias between FFF and WFF beams which must by further investigated.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-591: Optimizing the Flattening Filter Free Beam Selection in RapidArc-Based Stereotactic Body Radiotherapy for Stage I Lung Cancer

Purpose: To optimize the flattening filter free (FFF) beam energy selection in stereotactic body radiotherapy (SBRT) treatment for stage I lung cancer with different fraction schemes. Methods: Twelve patients suffering from stage I lung cancer were enrolled in this study. Plans were designed using 6XFFF and 10XFFF beams with the most widely used fraction schemes of 4*12 Gy, 3*18 Gy and 1*34 Gy, respectively. The plan quality was appraised in terms of planning target volume (PTV) coverage, conformity of the prescribed dose (CI100%), intermediate dose spillage (R50% and D2cm), organs at risk (OARs) sparing and beam-on time. Results: The 10XFFF beam predicted 1% higher maximum, mean dose to the PTV and 4–5% higher R50% compared with the 6XFFF beam in the three fraction schemes, whereas the CI100% and D2cm was similar. Most importantly, the 6XFFF beam exhibited 3–10% lower dose to all the OARs. However, the 10XFFF beam reduced the beam-on time by 31.9±7.2%, 38.7±2.8% and 43.6±4.0% compared with the 6XFFF beam in the 4*12 Gy, 3*18 Gy and 1*34 Gy schemes, respectively. Beam-on time was 2.2±0.2 vs 1.5±0.1, 3.3±0.9 vs 2.0±0.5 and 6.3±0.9 vs 3.5±0.4 minutes for the 6XFFF and 10XFFF one in the three fraction schemes. Conclusion: The 6XFFF beam obtains better OARs sparing in SBRT treatment for stage I lung cancer, but the 10XFFF one provides improved treatment efficiency. To balance the OARs sparing and intrafractional variation as a function of prolonged treatment time, the authors recommend to use the 6XFFF beam in the 4*12 Gy and 3*18 Gy schemes for better OARs sparing. However, for the 1*34 Gy scheme, the 10XFFF beam is recommended to achieve improved treatment efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated iterative beam angle selection in IMRT

Purpose: Iterative methods for beam angle selection (BAS) for intensity-modulated radiation therapy (IMRT) planning sequentially construct a beneficial ensemble of beam directions. In a naïve implementation, the nth beam is selected by adding beam orientations one-by-one from a discrete set of candidates to an existing ensemble of (n − 1) beams. The best beam orientation is identified in a time consuming process by solving the fluence map optimization (FMO) problem for every candidate beam and selecting the beam that yields the largest improvement to the objective function value. This paper evaluates two alternative methods to accelerate iterative BAS based on surrogates for the FMO objective function value. Methods: We suggest to select candidate beams not based on the FMO objective function value after convergence but (1) based on the objective function value after five FMO iterations of a gradient based algorithm and (2) based on a projected gradient of the FMO problem in the first iteration. The performance of the objective function surrogates is evaluated based on the resulting objective function values and dose statistics in a treatment planning study comprising three intracranial, three pancreas, and three prostate cases. Furthermore, iterative BAS is evaluated for an application in which a small number of noncoplanar beams complement a set of coplanar beam orientations. This scenario is of practical interest as noncoplanar setups may require additional attention of the treatment personnel for every couch rotation. Results: Iterative BAS relying on objective function surrogates yields similar results compared to naïve BAS with regard to the objective function values and dose statistics. At the same time, early stopping of the FMO and using the projected gradient during the first iteration enable reductions in computation time by approximately one to two orders of magnitude. With regard to the clinical delivery of noncoplanar IMRT treatments, we could show that optimized beam ensembles using only a few noncoplanar beam orientations often approach the plan quality of fully noncoplanar ensembles. Conclusions: We conclude that iterative BAS in combination with objective function surrogates can be a viable option to implement automated BAS at clinically acceptable computation times.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-179: Commissioning Dosimetric Data of a New 2.5 Megavoltage Imaging Beam from a TrueBeam Linear

Purpose: Recently a new 2.5 megavoltage imaging beam has become available in a TrueBeam linear accelerator for image guidance. There is limited information available related to the beam characteristics. Commissioning dosimetric data of the new imaging is necessary for configuration of the beam in a treatment planning system in order to calculate imaging doses to patients resulting from this new imaging beam. The purpose of this study is to provide measured commissioning data recommended for a beam configuration in a treatment planning system. Methods: A recently installed TrueBeam linear accelerator is equipped with a new low energy photon beam with a nominal energy of 2.5 MV which provides better image quality in addition to other therapeutic megavoltage beams. Dosimetric characteristics of the 2.5 MV are measured for commissioning. An ionization chamber was used to measure dosimetric data including depth-dose curves and dose profiles at different depths for field sizes ranging from 5×5 cm{sup 2} to 40×40 cm{sup 2}. Results: Although the new 2.5 MV beam is a flattening-filter-free (FFF) beam, its dose profiles are much flatter compared to a 6 MV FFF beam. The dose decrease at 20 cm away from the central axis is less than 30% for a 40×40 cm{sup 2} field. This moderately lower dose at off-axis distances benefits the imaging quality. The values of percentage depth-dose (PDD) curves are 53% and 63% for 10×10 cm{sup 2} and 40×40 cm{sup 2} fields respectively. The measured beam output is 0.85 cGy/MU for a reference field size at depth 5 cm obtained according to the AAPM TG-51 protocol. Conclusion: This systematically measured commissioning data is useful for configuring the new imaging beam in a treatment planning system for patient imaging dose calculations resulting from the application of this 2.5 MV beam which is commonly set as a default in imaging procedures.

60 APPLIED LIFE SCIENCES↗

SU-F-T-345: Quasi-Dead Beams: Clinical Relevance and Implications for Automatic Planning

Purpose: Beam direction selection for fixed-beam IMRT planning is typically a manual process. Severe dose-volume limits on critical structures in the thorax often result in atypical selection of beam directions as compared to other body sites. This work demonstrates the potential consequences as well as clinical relevance. Methods: 21 thoracic cases treated with 5–7 beam directions, 6 cases including non-coplanar arrangements, with fractional doses of 150–411cGy were analyzed. Endpoints included per-beam modulation scaling factor (MSF), variation from equal weighting, and delivery QA passing rate. Results: During analysis of patient-specific delivery QA a sub-standard passing rate was found for a single 5-field plan (90.48% of pixels evaluated passing 3% dose, 3mm DTA). During investigation it was found that a single beam demonstrated a MSF of 34.7 and contributed only 2.7% to the mean dose of the target. In addition, the variation from equal weighting for this beam was 17.3% absolute resulting in another beam with a MSF of 4.6 contributing 41.9% to the mean dose to the target; a variation of 21.9% from equal weighting. The average MSF for the remaining 20 cases was 4.0 (SD 1.8) with an average absolute deviation of 2.8% from equal weighting (SD 3.1%). Conclusion: Optimization in commercial treatment planning systems typically results in relatively equally weighted beams. Extreme variation from this can result in excessively high MSFs (very small segments) and potential decreases in agreement between planned and delivered dose distributions. In addition, the resultant beam may contribute minimal dose to the target (quasi-dead beam); a byproduct being increased treatment time and associated localization uncertainties. Potential ramifications exist for automatic planning algorithms should they allow for user-defined beam directions. Additionally, these quasi-dead beams may be embedded in the libraries for model-based systems potentially resulting in inefficient and less accurate deliveries.

60 APPLIED LIFE SCIENCES↗

SU-F-T-630: Energy Spectral Study On Lipiodol After Trans-Arterial Chemoembolization Using the Flattened and Unflattened Photon Beams

Purpose: SBRT combining transarterial chemoembolization with Lipiodol is expected to improve local control. Our showed that the dose enhancement effect in the Lipiodol with 10X flattening filter free (FFF) was inserted. This study was to investigate the energy fluence variations of electron in the Lipiodol using flattened (FF) and FFF beams. Methods: FF and FFF for 6X and 10X beams by TrueBeam were used in this study. The Lipiodol (3 X 3 X 3 cm{sup 3}) was located at the depth of 5 cm in water, the dose enhancement factor (DEF) and energy fluence were calculated by Monte Carlo (MC) calculations (PHITS). Results: DEFs with FF and FFF of 6X were 17.1% and 24.3% at rebuild-up region in the Lipiodol (5.3cm depth), 7.0% and 17.0% at the center of Lipiodol (6.5cm depth), and −13.2% and −8.2% at behind Lipiodol (8.3cm depth). DEFs with FF and FFF of 10X were 21.7% and 15.3% at rebuild-up region, 8.2% and 10.5% at the center of Lipiodol, and −14.0% and −8.6% at behind Lipiodol. Spectral results showed that the FFF beam contained more low-energy (0–0.3MeV) component of electrons than FF beam, and FF beam contained more high-energy (over 0.3MeV) electrons than FFF beam in Lipiodol. Behind the Lipiodol, build-down effect with FF beam was larger than FFF beam because FF beam contained more high energy electrons. The difference of DEFs between FFF and FF beams for 6X were larger than for 10X. This is because 10X beam contained more high-energy electrons. Conclusion: It was found that the 6XFFF beam gives the largest change of energy fluence and the largest DEF in this study. These phenomena are mainly caused by component of low-energy electrons, and this energy is almost correspond to the boundary of photo electronic dominant and Compton scattering dominant region for photon beams.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP1-01: Variable-Beam Fractionation for SAbR

Purpose: In current conventionally-fractionated as well as hypofractionated 3D conformal radiotherapy (CRT), the same beam arrangement is employed from fraction to fraction. We challenge this notion and postulate that by varying the beam arrangement between fractions we can achieve greater sparing of organs at risk (OARs) while maintaining PTV coverage. We use an inverse planning strategy using a swarm intelligence-based global optimization algorithm to exploit the additional degree of freedom represented by inter-fractional variation in beam angles. Methods: To evaluate our variable-beam fractionation (VBF) method, a 10-beam ITV-based conformal stereotactic ablative radiotherapy (CRT-SAbR) plan was optimized. In the clinical plan, 54 Gy was delivered to a 41cc lung tumor over 3 fractions. In VBF, each original clinically-assigned beam was multiplied to a bundle of n α-degree-spaced beams, n being number of fractions. Selection of α was a compromise between retaining similar tumor irradiation and separating inline OAR sub-regions. We optimized the beam fluence weights setting an upper limit for beam delivery duration (and implicitly, monitor units) along with clinical organ-based dose-volume constraints. Zero weights were allowed so that the optimization algorithm could remove unnecessary beams. All fractions in final plan had to deliver identical monitor units (MU) while satisfying a soft constraint on having no more than one beam from every n-beam bundle in each fraction. α was 10 degrees and the dose rate was 600 MU/min. Results: The VBF plan achieved significantly superior OAR sparing compared to the clinical internal target volume (ITV)-based plan. Setting maximum beam delivery duration to 13 seconds (well within breath-hold range), Esophagus Dmax, Heart Dmax, Spinal cord Dmax and Lung V13 were improved by 25%, 81%, 0% and 27%, respectively. Conclusion: We investigated a simple approach to inter-fractional VBF planning and demonstrated its potential in reducing dose to OARs. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

Astigmatic electron beam propagation

An astigmatic electron beam with an ellipticity ratio of approximately 2:1 was examined using the Enhanced Modified Faraday Cup (EMFC) diagnostic to measure its properties and show how the power density distribution varies near the beam waist. Results show that the beam has two power density peaks, one on either side of the beam crossover point, resulting from different focal distances of the major and minor axes of the elliptical beam shape. Quantification of the beam properties was used to establish a depth-of-field where the beam diameter and peak power densities are relatively constant. For the 1 kW beam studied here, the depth-of-field measured approximately ±5 mm from the beam crossover point, illustrating how electron beam diagnostics can be used to identify process control limits for repeatable and reliable welds under non-ideal electron beam power density distribution conditions.

36 MATERIALS SCIENCE↗

Spatially resolved measurements of electron cyclotron resonance ion source beam profile characteristics

Simulations predict that the concentric rings and the triangular structures in the profiles of strongly focused ion beams that are found in different experiments should be dominated by ion species with the same or at least similar m/q-ratio. To verify these theoretical predictions we have tuned our ECR ion source to deliver a beam consisting of multiple ion species whose particular m/q-depending focusing ranges from weakly focused to overfocused. We then recorded spatially resolved charge-state distributions of the beam profile at characteristic positions in the plane perpendicular to the beam line. The results validate theoretical predictions and are summarized in this paper. To achieve the required beam profile characteristics we moved the extraction along the beam line to achieve stronger focusing than by only changing the extraction voltage. To fit the regions of interest of the beam profile into the transmission area of the sector magnet, we steered the beam by moving the extraction in the plane perpendicular to the beam axis. The results of both investigations, beam focusing and beam steering by using a 3D-movable extraction, are also reported in this paper. A brief overview of the new beam monitor extensively used during these measurements, the Faraday cup array, is also given.

43 PARTICLE ACCELERATORS↗

Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed.

43 PARTICLE ACCELERATORS↗

Influence of the electrode gap separation on the pseudospark-sourced electron beam generation

Pseudospark-sourced electron beam is a self-focused intense electron beam which can propagate without any external focusing magnetic field. This electron beam can drive a beam-wave interaction directly or after being post-accelerated. It is especially suitable for terahertz radiation generation due to the ability of a pseudospark discharge to produce small size in the micron range and very high current density and bright electron beams. In this paper, a single-gap pseudospark discharge chamber has been built and tested with several electrode gap separations to explore the dependence of the pseudospark-sourced electron beam current on the discharge voltage and the electrode gap separation. Experimental results show that the beam pulses have similar pulse width and delay time from the distinct drop of the applied voltage for smaller electrode gap separations but longer delay time for the largest gap separation used in the experiment. It has been found that the electron beam only starts to occur when the charging voltage is above a certain value, which is defined as the starting voltage of the electron beam. The starting voltage is different for different electrode gap separations and decreases with increasing electrode gap separation in our pseudospark discharge configuration. The electron beam current increases with the increasing discharge voltage following two tendencies. Under the same discharge voltage, the configuration with the larger electrode gap separation will generate higher electron beam current. When the discharge voltage is higher than 10 kV, the beam current generated at the electrode gap separation of 17.0 mm, is much higher than that generated at smaller gap separations. The ionization of the neutral gas in the main gap is inferred to contribute more to the current increase with increasing electrode gap separation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EBIS/T charge breeding for intense rare isotope beams at MSU

Experiments with reaccelerated beams are an essential component of the science program of existing and future rare isotope beam facilities. NSCL is currently constructing ReA3, a reaccelerator for rare isotopes that have been produced by projectile fragmentation and in-flight fission and that have been thermalized in a gas stopper. The resulting low-energy beam will be brought to an Electron Beam Ion Source/Trap (EBIS/T) in order to obtain highly charged ions at an energy of 12 keV/u. This charge breeder is followed by a compact linear accelerator with a maximum beam energy of 3MeV/u for U-238 and higher energies for lighter isotopes. Next-generation rare isotope beam facilities like the Facility for Rare Isotope Beams FRIB, but also existing Isotope Separator On-line (ISOL) facilities are expected to provide rare-isotope beam rates in the order of 10(11) particles per second for reacceleration. At present the most promising scheme to efficiently start the reacceleration of these intense beams is the use of a next-generation high-current charge-breeder based on an EBIS/T. MSU has formed a collaboration to develop an EBIT for this purpose. A new high-current EBIS/T breeder will be developed and constructed at MSU, where also first tests on achievable beam rate capability will be performed. The EBIT is planned to be installed at the Isotope Separator and Accelerator facility ISAC at TRIUMF laboratory for on-line tests with rare isotope beams and to provide intense energetic reaccelerated radioactive beams. The status of the ReA3-EBIS/T in the NSCL reaccelerator project is given with a brief summary of results, followed by a discussion of plans for the future high-intensity EBIS/T charge breeder.

43 PARTICLE ACCELERATORS↗

Electrostatic and whistler instabilities excited by an electron beam

The electron beam-plasma system is ubiquitous in the space plasma environment. Here in this paper, using a Darwin particle-in-cell method, the excitation of electrostatic and whistler instabilities by a gyrating electron beam is studied in support of recent laboratory experiments. It is assumed that the total plasma frequency (ω pe ) is larger than the electron cyclotron frequency (Ω e ). The fast-growing electrostatic beam-mode waves saturate in a few plasma oscillations by slowing down and relaxing the electron beam parallel to the background magnetic field. Upon their saturation, the finite amplitude electrostatic beam-mode waves can resonate with the tail of the background thermal electrons and accelerate them to the beam parallel velocity. The slower-growing whistler waves are excited in primarily two resonance modes: (a) through Landau resonance due to the inverted slope of the beam electrons in the parallel velocity and (b) through cyclotron resonance by scattering electrons to both lower pitch angles and smaller energies. It is demonstrated that, for a field-aligned beam, the whistler instability can be suppressed by the electrostatic instability due to a faster energy transfer rate between the beam electrons and electrostatic waves. Such a competition of growth between whistler and electrostatic waves depends on the ratio of ω pe /Ω e . In terms of wave propagation, beam-generated electrostatic waves are confined to the beam region, whereas beam-generated whistler waves transport energy away from the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of output factors for stereotactic radiosurgery beams

Accurate dosimetry of the narrow beam tends to be difficult to perform due to the absence of lateral electronic equilibrium and the steep dose gradient, as well as the finite size of detectors. Thus, although the high dose rate 6 MV beam on the VARIAN Trilogy accelerator is increasingly utilized for stereotactic radiosurgery (SRS) treatment, there is no general agreement in the SRS beam output factor values among the Trilogy user community. Trilogy SRS beams are confined by cone collimators and the available collimator sizes range from 5 and 10 to 30 mm, in every 2 mm increment. A range of the relative output factors are in clinic use. This variation may impair observations of dose response and optimizations of the prescribed dose. It is necessary to investigate an accurate, easily performable, and detector independent method for the narrow beam output factor measurement. In this study, a scanning beam/scanning chamber method was proposed to overcome the limitation/difficulty of using a relatively large detector in narrow beam output factor measurement. Specifically, for the scanning beam method, multiple narrow beams are used for the dose measurement using a finite size chamber. These multiple scanning beams form an equivalent large uniform field which provides lateral electron equilibrium condition. After the measurement, the contributions from neighboring beams are deconvolved and the value is used for output factor determinations. For a Linac that cannot move a beam laterally, the scanning chamber method can be used to achieve the same result. The output factors determined in such a method were compared to chambers (a 0.015 cc PTW PinPoint ion chamber and a 0.125 cc PTW ion chamber) and film measurement, as well as with Monte Carlo simulation. Film and Monte Carlo results are found to be in excellent agreement with the measurement using the scan beam method. However, the VARIAN recommended output factors measured directly by Wellhoefer CC01 chamber and Scanditronix photon field diode are consistently higher for all the cones. Especially for the 5 mm cone, the difference is more than 10%. Overall, the results suggested that the new method can help overcoming the detector volume averaging effect and the positioning uncertainties, which constitute the major challenge in small radiosurgical beam output factor measurement, and provide reliable output factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reasonable Beam Deviation Envelope for Ray-tracing

At NSLS-II the unused dipole radiation is intercepted by the photon absorbers installed inside the vacuum chamber. The water-cooled absorbers are designed to take away the heat therefore the temperature is kept within the safety limit. However, if the beam orbit is severely perturbed, the radiation fan could pass through the geometry and strikes on the vacuum chamber components. This ray-leakage is a possible reason of the accelerator component temperature rise observed during the high-current operations. The goal of this work is to find the maximum beam deviation at the dipole hence ray-tracing can be re-examined under the operational constraints. The beam is confined to the orbit by the bending and focusing magnets. At NSLS-II the orbit is further controlled by a real time orbit feedback loop. Beam could be lost in any unpredictable direction if the magnet malfunctions. Consequently reasonable assumptions must be made to define the deviation envelope. It was determined that the dipole radiation is not powerful enough to cause damage within 10 ms, for example, if the rf power is shut off and the beam deviates from the orbit. Therefore we consider the radiation produced by the stored beam only; temporarily processes, such as unstable oscillating beam, should not be a concern. The orbit of the stored beam can be altered during magnet failures. The dipole current is interlocked to a small range of ±2% from the nominal value. If the dipole current changes slowly the beam energy automatically adjusts and the orbit remains the same. If the dipole current changes rapidly the beam will not be stable. Therefore dipole variation need not to be considered. For the other magnets we consider one magnet failure at a time because it is unlikely that two fail at the same time. It was found that the beam lifetime drops dramatically if one quadrupole power supply is turned off; therefore this scenario does not meet the stable beam condition. The current of one quadrupole could drop but will not result in orbit change with the feedback on. Beam could survive if one sextupole power supply is turned off, but the orbit will not be changed. Magnet could partially fail, for example, one or part of the coil shorts due to break-down. This is a low probability event and will not be considered. During daily operations the orbit is changed by the correctors and the rf frequency. In this work the correctors and the rf frequency are varied to explore the deviation envelope.

36 MATERIALS SCIENCE↗

Mirascope Luminescent Beam Profile Monitor

Advanced beam diagnostics are essential for reliable operation of high-performance accelerators and the intense beams produced by them. Non-invasive diagnostics can be used continuously with intense beams, while invasive techniques interfere with the beams and distort the beam profiles. In addition, traditional solid-based beam monitoring instrumentation produces unacceptable levels of radiation operating in high power beam environments. Noninvasive determination of accelerated particle distributions and profiles is the most difficult task of bunch diagnostics. Muons, Inc. proposed to develop non-interfering residual-gas beam profile monitors for transfer lines with pulse-to-pulse precision of better than 0.1 mm in position and size that will operate over a wide range of proton beam intensities including those needed for multi-MW beams of future facilities. The approach was to develop a low mass residual-gas profile monitor, where beam induced fluorescence (BIF) will be used to monitor the beam profile. An original scheme of light collection using a mirascope, an optical device invented in the 16th century, is proposed. The gas composition and pressure in the beam pipe are locally controlled to minimize unwanted radiation and to improve resolution.

43 PARTICLE ACCELERATORS↗