Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTIC MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

The integrated sounding system: Description and preliminary observations from TOGA COARE

An Integrated Sounding System (ISS) that combines state-of-the-art remote and in situ sensors into a single transportable facility has been developed jointly by the National Center for Atmospheric Research (NCAR) and the Aeronomy Laboratory of the National Oceanic and Atmospheric Administration (NOAA/AL). The instrumentation for each ISS includes a 915-MHz wind profiler, a Radio Acoustic Sounding System (RASS), an Omega-based NAVAID sounding system, and an enhanced surface meteorological station. The general philosophy behind the ISS is that the integration of various measurement systems overcomes each system's respective limitations while taking advantage of its positive attributes. The individual observing systems within the ISS provide high-level data products to a central workstation that manages and integrates these measurements. The ISS software package performs a wide range of functions: real-time data acquisition, database support, and graphical displays; data archival and communications; and operational and posttime analysis. The first deployment of the ISS consists of six sites in the western tropical Pacific--four land-based deployments and two ship-based deployments. The sites serve the Coupled Ocean-Atmosphere Response Experiment (COARE) of the Tropical Ocean and Global Atmosphere (TOGA) program and TOGA's enhanced atmospheric monitoring effort. Examples of ISS data taken during this deployment are shown in order to demonstrate the capabilities of this new sounding system and to demonstrate the performance of these in situ and remote sensing instruments in a moist tropical environment. In particular, a strong convective outflow with a pronounced impact of the atmospheric boundary layer and heat fluxes from the ocean surface was examined with a shipboard ISS. If these strong outflows commonly occur, they may prove to be an important component of the surface energy budget of the western tropical Pacific.

Parsons, David↗

Infrasonic directivity of monopole, dipole and bipole ground-surface reflected sources

Infrasound (acoustic waves below 20 Hz) can be used to detect, locate and quantify activity in the atmosphere such as volcanic eruptions and anthropogenic explosions. Attempts to quantify volcanic eruption parameters such as exit velocity, plume height and mass flow rate using infrasound data depend strongly on assumptions of the acoustic source type. Infrasonic sources may produce omnidirectional or directional wavefields, while propagation effects, such as interaction with topography, can induce further wavefield directivity that is measured by field instrumentation. Limited sampling of these wavefields can hinder our ability to infer the underlying source, and thus our understanding of the eruption characteristics. Equivalent sources are often used to represent acoustic source mechanisms and resultant wavefields. In this study, we review equivalent acoustic sources as they pertain to infrasonic scale and wavelengths commonly encountered in very local (⁠<5 km range) geophysical field deployments. We highlight the equivalent infrasonic bipole source that can be induced by ground-reflection of an elevated monopole; we are not aware of any prior infrasound studies that use the bipole source concept. We use analytical and numerical methods to explore source directivity of monopole, dipole and bipole ground-reflected sources at infrasonic frequencies as well as the additional directivity complications introduced by interactions with topography. We illustrate that for typical volcano-infrasound wavelengths, increasing height above the ground as well as increasing source frequency leads to increased wavefield directivity. Numerical modelling using a simple omnidirectional monopole source embedded in topography further illustrates that both horizontal and vertical infrasound directionality can be induced by topography at the distance scales appropriate for local volcano infrasound monitoring. Information summarized in this analytical and numerical exploration of infrasound directivity may be used to help guide future volcano-infrasound field deployments intended to estimate source parameters or quantify wavefield directivity. Analytic solutions for simple whole-space or half-space atmospheres provide useful formulations for planning or initially analysing geophysical field-scale experimental data; however, especially at very local distances from the source (⁠<5 km), 3-D simulations are necessary to account for complex topography commonly encountered in volcano-infrasound applications.

Infrasound↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Multimodality instrument for tissue characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

Mah, Robert W.↗

On the use of remote infrasound and seismic stations to constrain the eruptive sequence and intensity for the 2014 Kelud eruption

The February 2014 eruption of Kelud volcano (Indonesia) destroyed most of the instruments near it. We use remote seismic and infrasound sensors to reconstruct the eruptive sequence. The first explosions were relatively weak seismic and infrasound events. A major stratospheric ash injection occurred a few minutes later and produced long-lasting atmospheric and ground-coupled acoustic waves that were detected as far as 11,000 km by infrasound sensors and up to 2300 km away on seismometers. A seismic event followed ~12 minutes later and was recorded 7000 km away by seismometers. We estimate a volcanic intensity around 10.9, placing the 2014 Kelud eruption between the 1980 Mount St. Helens and 1991 Pinatubo eruptions intensities. As a result, we demonstrate how remote infrasound and seismic sensors are critical for the early detection of volcanic explosions, and how they can help to constrain and understand eruptive sequences.

58 GEOSCIENCES↗

Reservoir Stimulation Optimization with Operational Monitoring for Creation of EGS

EGS field projects have not sustained production at rates greater than ½ of what is needed for economic viability. The primary limitation that makes commercial EGS infeasible is our current inability to cost-effectively create high-permeability reservoirs from impermeable, igneous rock within the 3,000-10,000 ft depth range. Our goal is to develop a novel fracturing fluid technology that maximizes reservoir permeability while reducing stimulation cost and environmental impact. Laboratory equipment development to advance laboratory characterization/monitoring is also a priority of this project to study and optimize the physicochemical properties of these fracturing fluids in a range of reservoir conditions. Barrier G is the primarily intended GTO barrier to be addressed as well as support addressing barriers D, E and I.

15 GEOTHERMAL ENERGY↗

Nearby stars as gravitational wave detectors

Sun-like stellar oscillations are excited by turbulent convection and have been discovered in some 500 main-sequence and sub-giant stars and in more than 12,000 red giant stars. When such stars are near gravitational wave sources, low-order quadrupole acoustic modes are also excited above the experimental threshold of detectability, and they can be observed, in principle, in the acoustic spectra of these stars. Such stars form a set of natural detectors to search for gravitational waves over a large spectral frequency range, from 10{sup −7} to 10{sup −2} Hz. In particular, these stars can probe the 10{sup −6}–10{sup −4} Hz spectral window which cannot be probed by current conventional gravitational wave detectors, such as the Square Kilometre Array and Evolved Laser Interferometer Space Antenna. The Planetary Transits and Oscillations of State (PLATO) stellar seismic mission will achieve photospheric velocity amplitude accuracy of cm s{sup −1}. For a gravitational wave search, we will need to achieve accuracies of the order of 10{sup −2} cm s{sup −1}, i.e., at least one generation beyond PLATO. However, we have found that multi-body stellar systems have the ideal setup for this type of gravitational wave search. This is the case for triple stellar systems formed by a compact binary and an oscillating star. Continuous monitoring of the oscillation spectra of these stars to a distance of up to a kpc could lead to the discovery of gravitational waves originating in our galaxy or even elsewhere in the universe. Moreover, unlike experimental detectors, this observational network of stars will allow us to study the progression of gravitational waves throughout space.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

Some analyses of the variability of atmospheric parameters at low altitudes significant for aircraft propagation

The results are discussed in terms of the meteorological data acquisition procedures necessary to monitor changes in atmospheric parameters to support aircraft flyover noise measurements and aircraft noise certification programs. The data consisted primarily of sequential radiosonde ascents to approximately 5000 ft spaced some half-hour to an hour apart. The weather covered by the data sample was predominantly that of clear skies and calm-to-light surface winds associated with well established high-pressure systems. Under these restrictive weather conditions, the study shows that the largest variabilities in temperature and humidity occur during the early morning hours resulting from the effects of direct solar heating of the surface. These rapid changes apparently do not penetrate above approximately 1000 ft. In the late morning hours, the atmosphere appears to become stabilized so that net changes in temperatures and relative humidities at all levels are insignificant even in time periods exceeding three hours. By noon, however, turbulent fluctuations in surface wind and the wind speed itself increase to levels which would make the microphone recording of acoustic signals in the field difficult.

Chang, D. T.↗

Refining Principal Stress Measurements in Reservoir Underburden in Regions of Induced Seismicity through Seismological Tools, Laboratory Experiments - Final Technical Report

This project developed methodologies to measure the in-situ principal stress in the deep subsurface through use of multiple independent, but complementary, seismic methods, laboratory verification, and development of theoretical frameworks. By leveraging existing regional and local datasets we developed, tested, and refined a set of diagnostic tools for determining the in-situ stress state with reduced uncertainty at and below reservoir depths (1.5-6 km). A set of novel tools was produced that are scale independent, such that their utility is equivalent on regional, field scale, and near borehole monitoring of principal stresses in reservoir underburden for carbon storage projects. During a 4-year Department of Energy (DOE) and Southern Company funded project, carried out by the Electric Power Research Institute (EPRI), Lawrence Livermore National Laboratory (LLNL), the University of Oklahoma (OU), and the U.S. Geological Survey (USGS), the project team developed methodologies to measure the far-field in-situ principal stress in the deep subsurface, leveraging induced seismicity data from waste-water disposal projects. These methodologies consisted in the use of well-established and technically advanced seismic processing methods, such as virtual seismometer method-moment tensor (VSM-MT) and shear wave splitting (SWS), that are adept at recovering the stress orientation and certain components of the stress tensor. These methods were applied to robust seismicity catalogs created with matched filter techniques near sites of active fluid disposal—a proxy for carbon storage sites where such datasets are more limited. Estimates of the stress orientation made with seismic processing tools were considered along with laboratory acoustic emission experiments conducted on rock samples from the region of interest. Stress orientations in the studied region do not vary significantly across distances of ~100 km, nor are they found to rotate through time as a consequence of local wastewater disposal, as previously speculated. Finally, the project team investigated the trade-offs among the different seismic methods and evaluated the range of uncertainty that is generated with these methodologies, which led to a practical use and refinement of the VSM-MT technique when it is applied to field datasets. Understanding the trade-offs between these different methods highlighted the potential benefits of improved quantification of uncertainties on stress field estimations.

58 GEOSCIENCES↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

Underwater Noise Measurements around a Tidal Turbine in a Busy Port Setting

Acoustic emissions from current energy converters remain an environmental concern for regulators because of their potential effects on marine life and uncertainties about their effects stemming from a lack of sufficient observational data. Several recent opportunities to characterize tidal turbine sound emissions have begun to fill knowledge gaps and provide a context for future device deployments. In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire’s Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory’s Triton Field Trials (TFiT) described in this Special Issue, this effort provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites.

tidal turbine↗

The effect of modeling dose uncertainty on low-boom community noise dose-response curves

In logistic dose-response modeling, failing to account for uncertainty in estimated doses can cause an artificial flattening or attenuation of the slope of the summary curve. In Lee et al. [J. Acoust. Soc. Am. 147(4), pp. 2222-2234 (2020)], data from two NASA low-amplitude sonic boom community noise survey tests were modeled using a Bayesian multilevel logistic regression (MLR) statistical model that assumed there was no uncertainty in the noise dose estimates. However, in these community tests, the noise dose uncertainty was estimated by Page et al. [NASA/CR-2014-218180 and NASA/CR-2020-220589/Volume I] using a leave-one-out method. In the current work, a term was added to extend the Bayesian MLR model to account for the estimated noise dose uncertainty quantified in the Page et al. analyses. This uncertainty term was included in two ways, either as classical or as Berkson uncertainty, and yield similar results. When the uncertainty is accounted for in the Bayesian MLR model, the dose-response curves become 5-10% steeper, but the difference in the noise dose that elicits a 5% highly annoyed response is small (less than 1 dB). This result is encouraging for future X-59 community tests whose survey area will be sparsely populated with noise monitors.

X-59↗

Characterization of Embedded Sensors in Stainless Steel Test Articles and Design/Planning for MAGNET Testing

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes for heat rejection, which results in significant thermal stresses in the monolithic structures. This work describes the initial characterization and test plan for evaluating stainless steel test articles fabricated with embedded sensors for measuring heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing. The electrically heated testing will be performed in the non-nuclear Microreactor Agile Non-Nuclear Testbed and Single Primary Heat Extraction and Removal Emulator facilities located at Idaho National Laboratory. The goals of these tests are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. More generally, the ability to monitor component and system health during microreactor operation is attractive for providing a high sensor density to inform a limited number of microreactor operators to ultimately reduce operation and maintenance costs and move toward semi-autonomous operation. This report discusses the characterization of embedded thermocouples and fiber optic sensors in relevant test articles, including cylindrical pipes and hexagonal monolithic test articles for heat pipe-based reactors. The sensors were embedded by placing them in machined channels and then building up additional material by using ultrasonic additive manufacturing (UAM). UAM is a solid-state welding process that uses downward pressure and a lateral scrubbing motion to bond thin metal foils to a base material layer by layer. The ultrasonic welding process relies on the plastic deformation of the metal—as opposed to typical melting and solidification—to break oxide scales and bond the metal layers. The characterization of these embedded sensors included evaluating fiber optic signal attenuation, observing residual strain in the fibers, investigating microstructural and mechanical aspects, and demonstrating the sensors under various thermal loads and acoustic vibrations. Post-embedding characterization showed a fine grain structure (<1 μm) near the interfaces of the bonded foils as a result of severe deformation from the welding process. A large increase in hardness was observed at the foil interfaces and the fiber/matrix interface compared with the bulk matrix. Even when compared with the SS304 interfaces, the higher hardness observed around the embedded fiber suggests a higher degree of deformation due to the soft metal coating around the silica fiber core. The distributed fiber-optic temperature sensors and embedded thermocouples reliably measured temperature distributions during steady-state and transient thermal testing. The embedded fiber-optic sensors reliably measured strain during both transient and steady-state testing and properly identified resonant frequencies during acoustic testing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi‐Sensor Trajectory Reconstruction of the 24 April 2025 Alaska Fireball and Implications for Planetary Defense

On 24 April 2025 at 18:30:57 UTC, a bright daytime fireball over Southcentral Alaska was detected by 37 seismic stations, 16 single infrasound sensors, and four infrasound arrays, yielding 30 ballistic and multiple fragmentation arrivals. Here, the unprecedented density of seismoacoustic coverage enabled detailed reconstruction of the event using acoustic signals, with fragmentation source locations further guiding the identification of Doppler weather radar signatures of a meteorite fall. Incorporation of a radar-derived terminal point yielded a final trajectory solution, which agreed closely with an independent optical trajectory solution from video analysis. The reconstructed entry parameters from seismoacoustic analysis indicate a velocity of 25.3 km/s, an entry angle of 19°, and an energy release of ∼38 t TNT equivalent. Assuming a chondritic composition, the pre-entry object diameter was ∼0.7 m. Using orbital parameters from the optical solution, we estimate meteoroid composition as most likely an L-type ordinary chondrite. The event occurred in the sub-Arctic, where space-based optical systems face challenges in detection, demonstrating the critical role of dense ground-based seismoacoustic networks in characterizing high-latitude atmospheric entries. This uniquely well-recorded event demonstrates the capability of dense seismoacoustic networks to constrain bolide trajectories, energetics, and fragmentation, with radar and optical data providing critical confirmation and complementary perspectives. These results bridge the methodological gap between planetary-defense monitoring of natural impactors and space-traffic analyses of artificial reentries, illustrating how multi-sensor integration can deliver calibration-grade trajectories even for unpredicted events.

Fireball↗

Advances and Achievements in In Situ Analysis of Corrosion and Structure–Property Relationship in Mg Alloys

Every year, TMS Magnesium Committee carefully selects a special topic in magnesium (Mg) related research and development not only having the hottest subject from both academic and industrial perspectives but also demonstrating major achievements within this subject. Following last year’s topic on Mg microallying [1], this year’s focus is on in-situ methods and associated techniques in their broad definition spanning from laboratory- to large- scale facilities to process monitoring. The applications of in-situ techniques have a wide spectrum from the analysis of melts and liquid-solid transitions to solid-state phenomena during thermo-mechanical processing and heat treatments to surface interactions with various environments. Therefore, such works are of significant interest to scientists working in the area of Mg alloy development as well as to a much broader audience from both academia and industry. This interest is primarily caused by challenges in the analysis of structure-property relationship in Mg alloys, and even cursory glance of literature reveals sharp increase of publications relevant to this topic recently. For instance, very high reactivity of Mg as well as its well-known propensity to substantially alter structure upon unloading in mechanical testing makes it difficult to understand and thus to simulate correlation between microstructures observed in post-mortem analysis and physical processes during testing or fabrication. However, recent advances in in-situ analysis based on large-scale research facilities such as neutron scattering and synchrotron radiation sources as well as microscopy-based, acoustic emission, and other more traditional techniques allowed significant achievements. Apart from apparent development of relevant experimental techniques, a significant part of this success should also be attributed to increasing accessibility of the facilities and simplification of their use from a user perspective. The selection of articles in this special topic is quite far from comprehensive review covering all aspects of in-situ methods available for metallic materials development. However, this was not the purpose in any case. Instead, this selection is intended to present several studies on Mg alloys and Mg-based composites with the use of in-situ techniques. In addition, it overviews two techniques, ‘Acoustic Emission’ (AE) and ‘Ambient-Pressure X-ray Photoelectron Spectroscopy’ (AP-XPS), that are rather novel to the Mg community. These studies are supposed to give readers representative examples of such techniques potential and to help in navigating the spectrum of modern state-of-the-art analytical methods facilitating the development of Mg alloys. These articles are organized in the order corresponding to typical Mg alloy lifecycle from material preparation and solidification to thermo-mechanical processing and product fabrication to degradation.

36 MATERIALS SCIENCE↗

Nondestructive characterization of polycrystalline 3D microstructure with time-domain Brillouin scattering

In this paper, we employ gigahertz frequency ultrasonic waves to non-invasively image grain microstructure in polycrystalline ceria, an important electrolyte material for solid oxide fuel cells. This technique, termed time domain Brillouin scattering (TDBS), is a pump-probe technique that launches and monitors ultrasonics waves as they propagate from the surface into the depth of a sample. We demonstrate the capability of TDBS to image surface and subsurface grain structure by measuring mode and depth dependent velocity of the ultrasonic wave. A neural network tool is adopted to determine grain orientation from measured velocities. The TDBS results compare closely with electron backscatter diffraction (EBSD) measurements. This work expands the application of picosecond ultrasonics to three-dimensional imaging and offers a new route for the nondestructive microstructure characterization and in situ examination of polycrystalline materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of Multiharmonic QCM-D for Detection of Plasmin at Hydrophobic Surfaces Modified by β-Casein

Plasmin protease plays an important role in many processes in living systems, including milk. Monitoring plasmin activity is important for control of the nutritional quality of milk and other dairy products. We designed a biosensor to detect the proteolytic activity of plasmin, using multiharmonic quartz crystal microbalance with dissipation (QCM-D). The β-casein immobilized on the hydrophobic surface of 1-dodecanethiol on the AT-cut quartz crystal was used to monitor plasmin activity. We demonstrated detection of plasmin in a concentration range of 0.1–20 nM, with the limit of detection about 0.13 ± 0.01 nM. The analysis of viscoelastic properties of the β-casein layer showed rapid changes of shear elasticity modulus, μ, and coefficient of viscosity, η, at plasmin sub-nanomolar concentrations, followed by modest changes at nanomolar concentrations, indicating multilayer architecture β-casein. A comparative analysis of viscoelastic properties of β-casein layers following plasmin and trypsin cleavage showed that the higher effect of trypsin was due to larger potential cleavage sites of β-casein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗