Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Utah FORGE: Well 16A(78)-32 and 16B(78)-32 Stimulation Production Logging Tests

These are production logging tests (PLT) results from Halliburton collected during the nine hour circulation test performed at Utah FORGE on April 27th, 2024. The circulation test involved injecting into well 16A(78)-32 and producing out of well 16B(78)-32) and was carried out after the fracturing of both of those wells. Data attached here includes raw and processed PLT logs from both wells, as well as technical reports summarizing the data collection and results.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Well 16B(78)-32 Drill Core Fracture Analysis Images and Data

This dataset contains drilling core data from well 16B(78)-32, including PDF documents with flattened core images annotated by feature type and core interval, as well as spreadsheets detailing feature morphologies by depth, planar feature measurements, and planar feature orientations rotated to in situ conditions. Core was recovered from three intervals, one per stimulation stage, in the crystalline rocks affected by the stimulation of well 16A(78)-32. Seven core runs were conducted, yielding 135.8 feet of recovered core. Features in the core were categorized into planar fractures, semi-planar fractures, unbroken mineralized fractures, rough fractures, curviplanar fractures, concave-convex surfaces, and planar compositional features such as mylonite or dike-like structures. Planar features were measured while the core was positioned horizontally, with the core axis aligned to a downhole azimuth of 42 degrees. Planar core measurements from stimulations 2 and 3 that could be confidently correlated with FMI data were rotated to in situ orientations. This was done by rotating the planes along vertical and horizontal axes to match the azimuth and inclination data recorded in the directional survey of well 16B(78)-32, as well as applying an axial rotation to resemble the fracture orientations observed in the FMI log at corresponding depths. Coherent sets of planar fracture measurements were made by aligning the core within each 3-foot section of the dissected core barrel, and between adjacent 3-foot sections within a core run by matching rock fabrics, saw cuts and/or tool marks. Where coherent fracture measurements could not be made within a core run, data sets are denoted by a subscript (i.e. 2-Ta and 2-Tb both come from tangent core run number 2).

15 GEOTHERMAL ENERGY↗

SiGe quantum wells with oscillating Ge concentrations for quantum dot qubits

Large-scale arrays of quantum-dot spin qubits in Si/SiGe quantum wells require large or tunable energy splittings of the valley states associated with degenerate conduction band minima. Existing proposals to deterministically enhance the valley splitting rely on sharp interfaces or modifications in the quantum well barriers that can be difficult to grow. Here, we propose and demonstrate a new heterostructure, the “Wiggle Well”, whose key feature is Ge concentration oscillations inside the quantum well. Experimentally, we show that placing Ge in the quantum well does not significantly impact our ability to form and manipulate single-electron quantum dots. We further observe large and widely tunable valley splittings, from 54 to 239 μ eV. Tight-binding calculations, and the tunability of the valley splitting, indicate that these results can mainly be attributed to random concentration fluctuations that are amplified by the presence of Ge alloy in the heterostructure, as opposed to a deterministic enhancement due to the concentration oscillations. Quantitative predictions for several other heterostructures point to the Wiggle Well as a robust method for reliably enhancing the valley splitting in future qubit devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demand-side solutions to climate change mitigation consistent with high levels of well-being

Mitigation solutions are often evaluated in terms of costs and greenhouse gas reduction potentials, missing out on the consideration of direct effects on human well-being. Here, we systematically assess the mitigation potential of demand-side options categorized into avoid, shift and improve, and their human well-being links. Here we show that these options, bridging socio-behavioural, infrastructural and technological domains, can reduce counterfactual sectoral emissions by 40–80% in end-use sectors. Based on expert judgement and an extensive literature database, we evaluate 306 combinations of well-being outcomes and demand-side options, finding largely beneficial effects in improvement in well-being (79% positive, 18% neutral and 3% negative), even though we find low confidence on the social dimensions of well-being. Implementing such nuanced solutions is based axiomatically on an understanding of malleable rather than fixed preferences, and procedurally on changing infrastructures and choice architectures. Results demonstrate the high mitigation potential of demand-side mitigation options that are synergistic with well-being.

54 ENVIRONMENTAL SCIENCES↗

Validation of Play Fairway Analysis of the geothermal potential of Camas Prairie, south-central Idaho, by an exploration well

Abstract Play Fairway Analysis (PFA) methodology was adapted for geothermal exploration at Camas Prairie, Idaho. Geophysical data, structural and geologic mapping, volcanic rock ages and vent locations, and the distribution of thermal springs and wells all indicated a relatively high geothermal potential along the southern margin of the Prairie. An exploration well (USU Camas-1) was drilled to a depth of 618.3 m to validate the PFA. A permeable zone was encountered at ~ 357.5 m with a maximum measured temperature of ~ 80 °C, which was suppressed following the injection of cold water. A moderate transmissivity of ~ 0.25–1 cm 2 /s estimated from an injection test as well a seasonal artesian flow at ~ 0.7 L/s corroborate the presence of a permeable zone. The existence of a lacustrine clay seal was confirmed near the bottom of the basin-fill sediment occupying the upper 314 m of the well. Geothermometers suggest the USU Camas-1 well water equilibrated at a reservoir temperature of ~ 120 °C. Based on the locations of both thermal and cold wells, geothermal fluids appear to be flowing upward along one or both of two fault systems. The presence of young basalts and elevated helium isotope ratios suggest that the heat source of Camas Prairie is magmatic. However, the faults may be acting as a conduit for geothermal fluids to rise from great depth without a shallow magmatic source being present. Camas Prairie is a promising area for geothermal development, but the relatively low reservoir temperatures indicate this resource may not be suitable for electric generation. Perhaps the best use would be for heating.

Lachmar, Thomas E. (ORCID:0000000249640119)↗

Cape EGS: Frisco 2-P Well Stimulation Microseismic Data

This dataset contains microseismic data acquired during the Frisco 2-P well stimulation project led by Fervo Energy, conducted between June 1 and June 11, 2024, near the Utah FORGE geothermal site. The microseismic data was collected from various Utah FORGE wells: via Distributed Acoustic Sensing (DAS) fiber in 16B, and three 3-component geophones located in wells 56-32, 78B, and 32. The dataset is structured in SEGY format, where the first nine traces represent data from the geophones, and the remaining traces capture DAS data from well 16B. Each SEGY file in this dataset contains triggered microseismic events, with event initiation based on Short-Time Average over Long-Time Average (STA/LTA) detection criteria during the stimulation process. Files are grouped by time intervals and named following the structure "[WellPad][WellName][Month]_[Year]Divine_Trigger[EventNumber].sgy," indicating well pad, well name, date, and event number. Sampling parameters include a spatial sampling of approximately 2 meters for DAS channels and a temporal sampling rate of 2000 Hz, with each data record spanning 1.2 seconds. The files' coordinates are referenced to the location of the FORGE 16A-32 wellhead, positioned at UTM coordinates: Easting 334641.1891 m and Northing 4263443.693 m. The geographic coordinates for this origin are 38.50402147 latitude and -112.8963897 longitude, with an elevation of 1650.0249 meters above sea level.

15 GEOTHERMAL ENERGY↗

Groundwater elevation data for monitoring wells within the East and Taylor River basins, Colorado (USA)

This dataset is comprised of temporal variations in groundwater elevation data for the 24 monitoring wells located throughout the East River watershed. Seasonal to annual variations in groundwater elevations are a critical property of mountainous watersheds needed to understand both hydrological and below ground biogeochemical processes. Such data serve as a critical constraint for numerical models describing coupled groundwater-surface water behavior within the watershed. Additionally, the offset between the maximum and minimum groundwater elevations defines the extent of the bedrock weathering zone, with annual excursions in the groundwater hydrographic (i.e., the rising and falling hydrographic limbs) imposing primary controls on bedrock saturation state and redox conditions that govern biogeochemical reactions impacting nitrogen, carbon, and metals cycling. Manufacturer-specific software is used to download pressure data from each transducer, with broadly available spreadsheet software (e.g. Microsoft Excel) used to convert temporal variations in water pressure to elevations in units of meters above mean sea level. As additional monitoring wells are installed within the East River watershed and new groundwater monitoring wells are installed in the Taylor River watershed, temporal groundwater elevation data will be included as a part of this master dataset. Details regarding the metadata associated with each monitoring well location, including well depths, screened intervals, well location coordinates, and bedrock type, are included, as is a standard operating procedure for generating groundwater elevation data from water pressure values recorded by the pressure transducers. This dataset includes: (1) a zip file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.zip), containing (a) PNG of groundwater hydrographs, (b) a CSV file with groundwater elevation data, and (c) CSV file containing metadata organized by location; (2) an Excel file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.xlsx) with the groundwater elevation data, groundwater hydrographs, and metadata organized by location; (3) a Word file (Groundwater_elevation_data_protocols.docx) and a PDF file version (Groundwater_elevation_data_protocols.pdf) containing field protocols and methods; (4) a location metadata (locations.csv) file; (5) a file level metadata (flmd.csv); and (6) data dictionary (dd.csv) file.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Wabash CarbonSAFE. Geologic Analysis of the Potosi Dolomite Reservoir Interval and Potential Confining Units, at the Wabash #1 Well, Vigo Co., Indiana, Subtask 7.2, Technical Report

The Wabash CarbonSAFE project drilled the Wabash #1 stratigraphic test well (ID# 168045) at the Wabash Valley Resources (WVR) IGCC facility in Vigo County, Indiana, to evaluate the feasibility of commercial-scale CO 2 storage near the site. The Mt. Simon Sandstone was the initial target for storage evaluation and was found to have generally poor reservoir qualities in the Wabash #1 well. Focus was then placed on the secondary target, the Potosi Dolomite. For storage and containment evaluation an extensive suite of geophysical logs was collected throughout the borehole, and whole cores were obtained from the Mt. Simon Sandstone, Eau Claire Formation, and Maquoketa Group. The Maquoketa Group is identified as a regionally extensive secondary sealing interval above the Mt. Simon Sandstone and as a primary seal for the Potosi Dolomite storage complex. Due to concerns over potential lost circulation zones in the Potosi Dolomite during drilling, no core samples or Formation Micro Imager (FMI) logs were acquired in the Potosi Dolomite. However, cased hole well testing was performed over a 20 feet (6 m) interval within the Potosi Dolomite during which a fluid swab sample was obtained. Approximately 35 miles of 2D seismic information was acquired in the project area near Wabash #1 to aid in reservoir and caprock characterization. The highly porous and permeable zones in the Potosi Dolomite and lower Oneota Dolomite observed within the Wabash #1 well are, for the purpose of this report, considered the same reservoir package and referred to as the Potosi reservoir interval. This report presents a regional depositional context for the Potosi reservoir interval, the overlying confining zones in the Knox Group, and Maquoketa Group primary seal. This context is developed through detailed information obtained from the Wabash #1 well such as lithologic data collected from cuttings and core, geophysical logging, geomechanical analysis of core samples, and well testing and fluid sampling within the Potosi reservoir interval. Information discussed in this report was compiled as a basis for the development of static and dynamic geologic models of the Potosi Dolomite storage complex. The static and dynamic modeling of CO 2 injection in the Potosi reservoir interval are discussed in a separate report (Dessenberger et al., 2022) under the Wabash CarbonSAFE project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Technology Roadmap for Advanced Geothermal Well Construction

Recent analysis has shown that by 2050, geothermal energy can supply up to 90 GW of power to the U.S. electrical grid. Reducing the lifecycle cost of geothermal wells is critical to achieving this level of adoption. While time-related costs of drilling remain an important issue, there is also a need to focus on the costs associated with casing and cementing of geothermal wells. This report provides a roadmap of R&D activities needed to reduce the life cycle cost of casing and cementing while improving life-of-well performance. The purpose of the roadmap is to develop priorities for R&D in the areas of (1) high-performance and cost-effective materials for target geothermal well conditions, (2) well construction methods and techniques to reduce construction costs, and (3) methods and techniques to decrease to decrease long-term operating costs. The roadmap sets targets for the next 10-year period and purposely excludes R&D efforts into improved rock reduction. The roadmap was developed by a joint working group of experts from Oak Ridge National Laboratory, Brookhaven National Laboratory, and Sandia National Laboratories as well as 35 experts from industry and academia. Input from a series of information gathering sessions was used to inform and guide the development of the roadmap.

15 GEOTHERMAL ENERGY↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

High-Throughput Microfluidic Electroporation (HTME): A Scalable, 384-Well Platform for Multiplexed Cell Engineering

Electroporation-mediated gene delivery is a cornerstone of synthetic biology, offering several advantages over other methods: higher efficiencies, broader applicability, and simpler sample preparation. Yet, electroporation protocols are often challenging to integrate into highly multiplexed workflows, owing to limitations in their scalability and tunability. These challenges ultimately increase the time and cost per transformation. As a result, rapidly screening genetic libraries, exploring combinatorial designs, or optimizing electroporation parameters requires extensive iterations, consuming large quantities of expensive custom-made DNA and cell lines or primary cells. To address these limitations, we have developed a High-Throughput Microfluidic Electroporation (HTME) platform that includes a 384-well electroporation plate (E-Plate) and control electronics capable of rapidly electroporating all wells in under a minute with individual control of each well. Fabricated using scalable and cost-effective printed-circuit-board (PCB) technology, the E-Plate significantly reduces consumable costs and reagent consumption by operating on nano to microliter volumes. Furthermore, individually addressable wells facilitate rapid exploration of large sets of experimental conditions to optimize electroporation for different cell types and plasmid concentrations/types. Use of the standard 384-well footprint makes the platform easily integrable into automated workflows, thereby enabling end-to-end automation. We demonstrate transformation of E. coli with pUC19 to validate the HTME's core functionality, achieving at least a single colony forming unit in more than 99% of wells and confirming the platform's ability to rapidly perform hundreds of electroporations with customizable conditions. This work highlights the HTME's potential to significantly accelerate synthetic biology Design-Build-Test-Learn (DBTL) cycles by mitigating the transformation/transfection bottleneck.

Gaillard, William R↗

Vectorization of a penalty function algorithm for well scheduling

In petroleum engineering, the oil production profiles of a reservoir can be simulated by using a finite gridded model. This profile is affected by the number and choice of wells which in turn is a result of various production limits and constraints including, for example, the economic minimum well spacing, the number of drilling rigs available and the time required to drill and complete a well. After a well is available it may be shut in because of excessive water or gas productions. In order to optimize the field performance a penalty function algorithm was developed for scheduling wells. For an example with some 343 wells and 15 different constraints, the scheduling routine vectorized for the CYBER 205 averaged 560 times faster performance than the scalar version.

Absar, I.↗

Characteristics of AlGaAs/GaAs multiple quantum well infrared detectors

Researchers fabricated and characterized several AlGaAs/GaAs multiple quantum well infrared detectors to evaluate the ultimate performance of these devices for low infrared background applications. The detectors were designed to have a single bound state in the quantum well and the first excited state in the continuum above the AlGaAs conduction band edge. The difference in energy between the two levels, as determined by the quantum well width and aluminum mole fraction in the barrier, was chosen such that peak absorption would occur near 8 microns. The initial structures studied comprised 50 periods with 40 A well widths and 300 A Al(0.28)Ga(0.72)As barriers. The performance of these detectors are summarized. To better interpret these results and design optimized detectors, researchers modeled both the detector noise and tunneling currents. The noise model correctly predicts that multiple quantum well detectors will, indeed, exhibit noise lower than full shot noise. The tunneling current model predicts the dark current versus bias for any choice of design parameters in a multiple quantum well detector. This model predicts a substantially reduced dark current (x 10(exp 04)) for samples with 400 A barriers. To evaluate structures with thicker barriers, researchers fabricated and characterized detectors with 400 A and 500 A barriers; a comparison of detector dark currents is shown. These results are consistent with the predictions of the dark current model.

Janousek, Bruce K.↗

Photoexcited escape probability, optical gain, and noise in quantum well infrared photodetectors

We present a detailed and thorough study of a wide variety of quantum well infrared photodetectors (QWIPs), which were chosen to have large differences in their optical and transport properties. Both n- and p-doped QWIPs, as well as intersubband transitions based on photoexcitation from bound-to-bound, bound-to-quasi-continuum, and bound-to-continuum quantum well states were investigated. The measurements and theoretical analysis included optical absorption, responsivity, dark current, current noise, optical gain, hot carrier mean free path; net quantum efficiency, quantum well escape probability, quantum well escape time, as well as detectivity. These results allow a better understanding of the optical and transport physics and thus a better optimization of the QWIP performance.

Levine, B. F.↗

Developing a Drilling Optimization System for Improved Overall Rate of Penetration in Geothermal Wells

Geothermal energy is renewable, reliable and environmentally friendly source of energy. The major cost in the development of geothermal wells is the actual drilling of the wells. The main objective of this paper is to introduce a new real-time drilling optimization system designed for granite formation to reduce the overall drilling cost. In this study, a drilling optimization system is verified using drilling data from Utah-Forge well 58-32. The drilling optimization system used the Utah-Forge well 58-32 data to achieve real-time unconfined compressive strength (UCS). Based on the UCS value from the previous feet, the system simulates the ROP for the next drilling feet. The drilling optimization system utilizes the Differential Evolution Algorithm (DEA), which is a metaheuristic method to search the space of solution, to find the best operating parameters (i.e. WOB and RPM) for the next drilling foot. The optimization algorithm takes a maximum cutter temperature into account as a constraint and avoids the accelerated wear. The developed drilling optimization system improves ROP responses and reduces the drilling cost of geothermal wells. The simulated ROP results from the system show a good agreement with the ROP from Utah-Forge well 58-32 drilling data. The drilling time before and after optimization for both intervals were presented.

15 GEOTHERMAL ENERGY↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Heat pulse testing at monitoring wells to estimate subsurface fluid velocities in geological CO 2 storage

Monitoring the injected CO 2 during geological CO 2 storage (GCS) is essential to assure containment and identify CO 2 leakage. Here in this work, a new approach is introduced to estimate the evolution of the downhole fluid velocity at a monitoring well and identify CO 2 arrival time using in-well heat pulse/tracer test. The proposed technique involves using a downhole heater to generate a series of heat pulses and measuring their corresponding temperature response. The surface temperature of the downhole heater is controlled by the supplied electrical power and the heat loss by convection to the surroundings. Convective heat transfer is well described using Newton's law of cooling in which the temperature difference between the heater and the surrounding fluids drives the heat transfer, for which the convection heat transfer coefficient (h) controls the magnitude of heat loss. Among various factors that control h, it depends on the type of the flowing fluid and its velocity. Through analyzing the measured temperature at different heat pulses, the changes in h - due to mobilization of the in-situ brine or CO 2 arrival - can be estimated. Consequently, the velocity of the flowing fluid across the heater can be obtained. Since heat transfer by convection is sensitive to the type of the surrounding fluid, intrusion of CO 2 can be detected from the relatively higher surface temperature obtained at CO 2 arrival. Churchill and Bernstein (1977)'s correlation is adopted to estimate the change of fluid velocity in terms of the change in h. To demonstrate the validity of the proposed technique, the results are applied and validated against those of COMSOL Multiphysics simulation tool for single-phase brine (before CO 2 arrival) and single-phase CO 2 (after CO 2 arrival). The observed temperature heating is sensitive to the flowing fluid velocity and fluid type. The temperature signal observed at CO 2 arrival is large and easily detectable using temperature monitoring tool which provides reliable indication for tracking CO 2 arrival at monitoring wells compared with passive temperature monitoring. The results obtained using the proposed technique agree very well with the numerical results obtained from the simulation tool with a maximum estimation error of 7 percent.

02 PETROLEUM↗