Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “weight loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Extended Performance 8-cm Mercury Ion Thruster

A slightly modified 8-cm Hg ion thruster demonstrated significant increase in performance. Thrust was increased by almost a factor of five over that of the baseline thruster. Thruster operation with various three grid ion optics configurations; thruster performance as a function of accelerator grid open area, cathode baffle, and cathode orifice size; and a life test of 614 hours at a beam current of 250 mA (17.5 mN thrust) are discussed. Highest thruster efficiency was obtained with the smallest open area accelerator grid. The benefits in efficiency from the low neutral loss grids were mitigated, however, by the limitation such grids place on attainable ion beam current densities. The thruster components suffered negligible weight losses during a life test, which indicated that operation of the 8-cm thruster at extended levels of thrust and power is possible with no significant loss of lifetime.

Mantenieks, M. A.↗

An overview of the endocrine and metabolic changes in manned space flight

Analyses of endocrinological and metabolic data from humans during spaceflight, particularly the Skylab crews, are summarized to define the levels of knowledge of these processes and the techniques for studying them. The glomerular filtration rate was tested by urine and blood samples, yielding indications of a creatinine clearance increase. The mechanisms for an increase of free water clearance, implying an increase of antidiuretic hormone, are uncertain, and tests are also under way to evaluate the role of prostaglandins in-flight, to account for decreases in catecholamine excretion. Bone mineral losses of 7.9% were observed at the end of 84 days, and processes are suggested for the calcium metabolism. Finally, the observation of almost universal weight loss among space crewmembers is examined, and a loss of muscle tone due to decreased metabolic efficiency is cited as a feature of long duration spaceflight.

Leach, C. S.↗

Fluid shifts during thermal stress with and without fluid replacement

Six unacclimatized men rested for 4 hr in a hot, dry environment without fluid replacement (DH). Another group of six men were exposed to the same thermal stress, replacing evaporative fluid loss with warm 0.1% NaCl solution (FRP). Total grams of circulating hemoglobin, determined by CO immediately prior to and again during the last minutes of heat exposure, increased an insignificant 1.6 and 1.3% during DH and FRP, respectively. With DH, body weight loss of 2.6% was accompanied by a 7.8% reduction in calculated plasma volume (PV). Even when body weight was maintained (FRP), PV decreased 2.9% during the heat exposure. Total circulating serum protein did not change as a result of the heat stress with either DH or FRP. In a test-retest series of experiments on four men, DH was not detrimental to sweat rate. It is shown that hemodilution is not a general response to acute heat exposure. The disproportionately large reduction in PV during thermal dehydration is confirmed.

Myhre, L. G.↗

Aeolian abrasion on Venus: Preliminary results from the Venus simulator

The role of atmospheric pressure on aeolian abrasion was examined in the Venus Simulator with a constant temperature of 737 K. Both the rock target and the impactor were fine-grained basalt. The impactor was a 3 mm diameter angular particle chosen to represent a size of material that is entrainable by the dense Venusian atmosphere and potentially abrasive by virtue of its mass. It was projected at the target 10 to the 5 power times at a velocity of 0.7 m/s. The impactor showed a weight loss of approximately 1.2 x 10 to the -9 power gm per impact with the attrition occurring only at the edges. Results from scanning electron microscope analysis, profilometry, and weight measurement are summarized. It is concluded that particles can incur abrasion at Venusian temperatures even with low impact velocities expected for Venus.

Marshall, J. R.↗

Evaluation of high temperature capacitor dielectrics

Experiments were carried out to evaluate four candidate materials for high temperature capacitor dielectric applications. The materials investigated were polybenzimidazole polymer and three aramid papers: Voltex 450, Nomex 410, and Nomex M 418, an aramid paper containing 50 percent mica. The samples were heat treated for six hours at 60 C and the direct current and 60 Hz alternating current breakdown voltages of both dry and impregnated samples were obtained in a temperature range of 20 to 250 C. The samples were also characterized in terms of their dielectric constant, dielectric loss, and conductivity over this temperature range with an electrical stress of 60 Hz, 50 V/mil present. Additional measurements are underway to determine the volume resistivity, thermal shrinkage, and weight loss of the materials. Preliminary data indicate that the heat treatment of the films slightly improves the dielectric properties with no influence on their breakdown behavior. Impregnation of the samples leads to significant increases in both alternating and direct current breakdown strength. The results are discussed and conclusions made concerning their suitability as high temperature capacitor dielectrics.

Hammoud, Ahmad N.↗

Physiological mass measurements on Skylab 1/2 and 1/3

Mass measurements of crewmen and objects were made for the first time in space during Skylab. A description of the new devices designed for such measurements and of the technique of their use is detailed. Results from ground-based chamber simulation tests and from those during Skylab II and III show similar patterns of simple metabolic deficits, of a rapid loss during the first few days of flight followed by a reciprocal gain for the first few postflight days, and other transient changes. It is concluded that two major causes of weight loss are present: (1) a fluid redistribution and loss, and (2) metabolic losses. Added to these are short-term changes from transient stress. Smaller, simpler, and cheaper devices have since been designed which should allow mass measurements on virtually any object in almost any spacecraft.

Thornton, W.↗

Characterization of Cold Sprayed CuCrAl-Coated and Uncoated GRCop-84 Substrates for Space Launch Vehicles

A newly developed Cu-23(wt.%)Cr-5%Al (CuCrAl) alloy is currently being considered as a protective coating for GRCop-84 (Cu-8(at.%)Cr-4%Nb). The coating was deposited on GRCop-84 substrates by the cold spray deposition technique. Cyclic oxidation tests conducted in air on both coated and uncoated substrates between 773 and 1073 K revealed that the coating remained intact and protected the substrate up to 1073 K. No significant weight loss of the coated specimens were observed at 773 and 873 K even after a cumulative cyclic time of 500 h. In contrast, the uncoated substrate lost as much as 80% of its original weight under similar test conditions. Low cycle fatigue tests revealed that the fatigue lives of thinly coated GRCop-84 specimens were similar to the uncoated specimens within the limits of experimental scatter. It is concluded that the cold sprayed CuCrAl coating is suitable for protecting GRCop-84 substrates.

Raj, S. V.↗

Scale Adhesion, Sulfur Content, and TBC Failure on Single Crystal Superalloys

This paper summarizes the main effects of sulfur impurity content on the cyclic oxidation resistance of single crystal superalloys, with emphasis on scale and TBC adhesion. Eleven hundred degrees C cyclic oxidation of PWA 1480 produces scale spallation leading to a weight loss of more than 30 Mg/sq cm after 500 one-hr cycles for a sulfur content of 6 ppmw. The sulfur content was reduced to levels below 0.1 ppmw by hydrogen annealing, resulting in weight gains of only 0.5 to 1.0 Mg/sq cm after 1000 one-hr cycles. Samples were produced with various sulfur contents by adjusting the annealing temperature, time, and sample thickness (i.e., diffusion product Dt/L(exp 2)). The subsequent cyclic oxidation behavior, mapped over a sulfur content/thickness diagram, shows a transition to adherent behavior at sulfur levels equivalent to 1 monolayer of total segregation. Additional information is contained in the original extended abstract.

Smialek, James L.↗

Body Weight Gain during Altered Gravity: Spaceflight, Centrifugation and Transitions

Gravity is a force that influences all living systems, and is often disregarded in the study of environment on growth and development. To assess the effect of gravity exposure on growth, immature rats (130-200 g) were evaluated during chronic altered gravity exposure and during transition between gravity fields. The effects of 14 days of spaceflight on body weight gain were evaluated (n=12) and compared to controls. Spaceflight did not affect weight gain. In 6 rats, the transition from spaceflight to 1 G showed a significant (p less than 0.05) post flight weight loss over 48 hr of 13 g compared to controls. Over subsequent days this loss was compensated for with no difference noted after 5 days. Exposure to hypergravity, 2 G for 16 days, was evaluated in groups of n=6 (Control; On Center Control (OCC); Centrifuged). With centrifugation or OCC there was a reduction in body weight within 24 hr. The OCC regained control weights within 13 days. The weight difference, 26 +/- 1 g, persisted with 2 G with no subsequent difference in weight gain over days 3-16 compared to controls; 3.7 +/- 0.1 versus 3.9 +/- 0.1 g/day respectively. Transition from centrifugation to 1 G resulted in a weight increase within 48 hours. Over 16 days the rate of gain was increased 3.1 +/- 0.1 g/day for centrifuge compared to 2.1 +/- 0.1 g/day for controls between Day 3 to 16. However, differences from control were still noted on Day 16. Transition from one gravity field to another causes acute changes in body weight. Transition to microgravity or 1 G, following the acute changes, results in adjustments to attain a normal weight. In hypergravity the acute reduction in body weight persist, but weight gain is normal. Transitioning from hypergravity to 1G results in an increased weight gain to compensate for the persistent reduction during exposure.

Wade, Charles E.↗

Experiment K-7-35: Circadian Rhythms and Temperature Regulation During Spaceflight: Metabolism - Part 2

Energy expenditure can be regarded as the sum of two components; the basal metabolic rate and the energy costs of activity. Weight loss is usually associated with an energy deficit. A negative energy balance exists when energy intake is less that energy utilization. The deficit is made up by tissue catabolism (principally fat, but also some protein). By analyzing food and water intake, urine and fecal output, and changes in body weight, the Skylab investigators reached the unexpected conclusion that energy expenditure during spaceflight was about 5% greater than at 1 G (Leonard, 1983; Rambaut et al., 1977). Possible explanations for the human metabolic responses are an increased workload during spaceflight (Leonard, 1983), or as Rambaut and co-workers (1977) suggested, a progressive decrease in metabolic efficiency. It is likely to be very difficult to distinguish between these two possibilities in man because the activity component may be different during spaceflight than it is the ground. The problem is to measure energy expenditure with efficient precision during spaceflight in a non-invasive manner which will not interfere with other investigations or take an time. The doubly labeled water (DLW) method meets these criteria. The DLW method is the only method available for continuously measuring energy expenditure during spaceflight given the severely restricted conditions in the spaceflight environment. Therefore, this study focuses on the development and use of this procedure on nonhuman primates during spaceflight. Energy expenditure and total body water was determined in two Rhesus monkeys by the doubly labeled water (2H2'80) method. Three determinations were made. Monkey B (#2483) was studied twice, during the flight of COSMOS 2044 and during a follow-up ground control study a month later. A second monkey was studied on the ground only (Monkey D, #782).

Fuller, C. A.↗

Further development of high temperature-resistant graphite fiber coupling agents

Potential coupling agents for graphite fibers were screened by their effect on the weight losses of Thornel 300, HMS, and HTS fibers at 588K for 200 and 400 hours. Unidirectional laminates were made from HMS and HTS fibers, untreated, and treated with each of the seven coupling agents. The matrix of all laminates was PMR polyimide (PMR-PR). On the basis of the best overall retention of elevated temperature interlaminar shear strength after 200 hours at 588K, composite weight after 200 hours at 588K, and fiber weight after 400 hours at 588K, ventromer T-1 applied from aqueous solution and pyrolyzed PPQ were selected for further evaluation as coupling agents for HTS fiber while ventromer T-2 and pyrolyzed PPQ were selected as coupling agents for HMS fiber. It was shown that pyrolyzed PPQ as a coupling agent improves the oxidative stability of HTS/PMR-PI composites.

Griffin, R. N.↗

Flame retardant polyphosphazenes

Three processes for the preparation of polyphosphazenes were investigated: (1) the reaction of bisphosphines with diazides, (2) the condensation of bisdichlorophosphoranes with diamines; and (3) the treatment of bisphosphines with diamines in the presence of carbon tetrachloride followed by base dehydrohalogenation. All products obtained were of low molecular weight; the degree of polymerization did not exceed twelve repeating units. However, several compositions exhibited good thermal stability. No weight loss was observed up to 390 C when heated in air at 5 C/min. Treatment of bisphosphines with either an excess of a diazide or an excess of a diamine in the presence of carbon tetrachloride resulted in the production of difunctional phosphazenes which were respectively, azido and amino terminated. The reaction of these azido terminated extended monomers with bisphosphines did not produce high molecular weight materials. The bis-aminophosphazene prepared for the first time under this contract was successfully incorporated into a polyimide.

Paciorek, K. L.↗

A study of the possible effect of a thermal post cure on the mechanical properties of the 404 carbon-phenolic ring of the space shuttle solid rocket motor nozzle

Erratic pockets of erosion have occurred on the inner perimeter of the 404 rocket nozzle ring during liftoff firing. It is thought that it may be caused by pockets of volatile matter entrapped during manufacture. A thermal post cure was suggested as a possible means of outgassing such pockets, if they in fact do exist. To confirm an outgassing during a post cure and to establish a working upper temperature limit, thermal gravimetric and differential calorimetric analyses were made on a number of samples from two 404 rings supplied by the manufacturer. Continuous weight loss was observed over the temperature range explored (750 F) indicating outgassing, and a strong exothermic reaction occurs beginning about 390 F. Thus, an upper post cure temperature of 350 F is recommended. To determine the possible effect of a post cure on physical properties, the following tests will be made on matched sets of cured and post cured material: x-radiography (internal structure), linear dimensions, weight, porosity, cross ply thermal expansion, drop and double notch shear strengths, and tensional strength in the ply direction.

Giardini, A. A.↗

Long-Term Durability of a Matrix for High-Temperature Composites Predicted

Polymer matrix composites (PMC's) are being increasingly used in applications where they are exposed for long durations to harsh environments such as elevated temperatures, moisture, oils and solvents, and thermal cycling. The exposure to these environments leads to the degradation of structures made from these materials. This also affects the useful lifetimes of these structures. Some of the more prominent aerospace applications of polymer matrix composites include engine supports and cowlings, reusable launch vehicle parts, radomes, thrust-vectoring flaps, and the thermal insulation of rocket motors. This demand has led to efforts to develop lightweight, high-strength, high-modulus materials that have upper-use temperatures over 316 C. A cooperative program involving two grants to the Massachusetts Institute of Technology and in-house work at the NASA Glenn Research Center was conducted to identify the mechanisms and the measurement of mechanical and physical properties that are necessary to formulate a mechanism-based model for predicting the lifetime of high-temperature polymer matrix composites. The polymer that was studied was PMR-15 polyimide, a leading matrix resin for use in high-temperature-resistant aerospace composite structures such as propulsion systems. The temperature range that was studied was from 125 to 316 C. The diffusion behavior of PMR-15 neat resin was characterized and modeled. Thermogravimetric analysis (TGA) was also conducted in nitrogen, oxygen, and air to provide quantitative information on thermal and oxidative degradation reactions. A new low-cost technique was developed to collect chemical degradation data for isothermal tests lasting up to 4000 hr in duration. In the temperature range studied, results indicate complex behavior that was not observed by previous TGA tests, including the presence of weight-gain reactions. These were found to be significant in the initial periods of aging from 125 to 225 C. Two types of weight loss reactions dominated at aging temperatures above 225 C. One was concentrated at the surface of the polymer and was very active at temperatures above 225 C. The second was observed to dominate in the latter stages of aging at temperatures below 260 C. This three-reaction model satisfactorily explains past findings that the degradation mechanism of PMR-15 appears to change around 316 C. It also indicates that the second weight gain mechanism is a significant factor at temperatures below 204 C. On the basis of these results, a predictive model was developed for the thermal degradation of PMR-15 at 316 C. A comparison of data generated by this model with actual experimental data is shown in the following figure.

Bowles, Kenneth J.↗

The effect of Na vapor on the Na content of chondrules

Chondrules contain higher concentrations of volatiles (Na) than expected for melt droplets in the solar nebula. Recent studies have proposed that chondrules may have formed under non-canonical nebular conditions such as in particle/gas-rich clumps. Such chondrule formation areas may have contained significant Na vapor. To test the hypothesis of whether a Na-rich vapor would minimize Na volatilization reaction rates in a chondrule analog and maintain the Na value of the melt, experiments were designed where a Na-rich vapor could be maintained around the sample. A starting material with a melting point lower that typical chondrules was required to keep the logistics of working with Na volatilization from NaCl within the realm of feasibility. The Knippa basalt, a MgO-rich alkali olivine basalt with a melting temperature of 1325 +/- 5 C and a Na2O content of 3.05 wt%, was used as the chondrule analog. Experiments were conducted in a 1 atm, gas-mixing furnace with the fO2 controlled by a CO/CO2 gas mixture and fixed at the I-W buffer curve. To determine the extent of Na loss from the sample, initial experiments were conducted at high temperatures (1300 C - 1350 C) for duration of up to 72 h without a Na-rich vapor present. Almost all (up to 98%) Na was volatilized in runs of 72 h. Subsequent trials were conducted at 1330 C for 16 h in the presence of a Na-rich vapor, supplied by a NaCl-filled crucible placed in the bottom of the furnace. Succeeding Knudsen cell weight-loss mass-spectrometry analysis of NaCl determined the P(sub Na) for these experimental conditions to be in the 10(exp -6) atm range. This value is considered high for nebula conditions but is still plausible for non-canonical environments. In these trials the Na2O content of the glass was maintained or in some cases increased; Na2O values ranged from 2.62% wt to 4.37% wt. The Na content of chondrules may be controlled by the Na vapor pressure in the chondrule formation region. Most heating events capable of producing chondrules are sufficient to volatile Na. Sodium volatilization reaction rates will be reduced to varying degrees from melt droplets, depending on the magnitude of the P(sub Na) generated. A combination of Na vapor during, and Na diffusion back into chondrules after, formation could maintain and/or enrich Na concentrations in chondrules.

Lewis, R. Dean↗