Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Application of unsupervised deep learning to image segmentation and in-situ contact angle measurements in a CO 2 -water-rock system

Rock surface wettability is a critical property that regulates multiphase flows in porous media, which can be quantified using the surface contact angle (CA). X-ray micro-computed tomography (μCT) provides an effective approach to in-situ measurements of surface CAs. However, the CA measurement accuracy depends significantly on the quality of CT image segmentation, which is the clustering of CT pixels into separate phases. Inspired by this, we developed a deep learning (DL)-based CA measurement workflow. Motivated by the recent tremendous progress in unsupervised learning techniques and aiming to avoid expensive manual data annotations, an unsupervised DL pipeline for CT image segmentation was proposed and implemented, which includes unsupervised model training and post-processing. The unsupervised model training was driven by a novel loss function constrained with feature similarity and spatial continuity and implemented by iterative forward and backward paths; the former clustered the pixel-wise feature vectors extracted by convolution neural networks, whereas the latter updated the parameters using gradient descent. An over-segmentation strategy was adopted for model training. The post-processing steps based on agglomerative hierarchical clustering (AHC) were implemented to further merge the over-segmented model output to the desired cluster number, which is intended to improve the efficiency of image segmentation. The developed unsupervised DL pipeline was compared with other commonly-used image segmentation methods using pixel-wise and physics-based evaluation metrics on a synthetic raw-image dataset, which had a known ground truth. The unsupervised DL pipeline showed the best performance. Next, the segmented images were input to an automatic CA measurement tool, and the results were validated by comparisons with manual measurements. The CA values from the manual and automatic measurements showed similar distributions and statistical properties. The automatic measurement demonstrated a wider spectrum because of the much larger number of measurement data points. The primary novelty of the unsupervised DL pipeline developed in this study lies in the novel loss function and the over-segmentation strategy associated with AHC post-processing. Finally, the workflow has been proven an efficient tool for pore-scale wettability characterization, which has a wide range of applications in fundamental studies of multiphase flows in natural porous media, which have critical implications to geological carbon sequestration, hydrocarbon energy recovery, and contaminant transport in groundwater.

42 ENGINEERING↗

Real-Time MPC for Residential Building Water Heater Systems to Support the Electric Grid

The world of IoT (internet of things) is spawning new control options and decision making that has not been available before. This is providing a wealth of opportunities for transactive type controls and systems that can negotiate for a common goal. This paper discusses a transactive residential neighborhood with optimization at the home level utilizing a system of agents. The real-time optimization utilizes information and modeling to optimize heat pump water heater operation in occupied homes. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Starke, Michael↗

FIND: A Synthetic weather generator to control drought Frequency, Intensity, and Duration

Water systems worldwide are experiencing climate change-induced shifts in drought properties like frequency, intensity, and duration, affecting water security and reliability. To develop and test effective drought preparedness plans, researchers often use synthetic weather generators to create hydrological scenarios that explore drought variability beyond historical records. Existing weather generators typically allow users to adjust streamflow statistics like percentiles or temporal correlation but do not directly control drought properties of frequency, intensity, and duration. To fill this gap, we propose FIND (Frequency, INtensity, and Duration) synthetic weather generator. FIND incorporates a standardized drought index to directly and in dependently control drought frequency, intensity, and duration in generated streamflow time series while preserving observed hydrological variability. Use cases for FIND include i) water systems analysis applications that seek to train and test drought strategies under historical and plausible future drought conditions, and ii) bottom-up vulnerability studies relating system vulnerability outcomes to specific changes in drought properties of frequency, intensity, and duration. Here, we demonstrate FIND’s versatility through three experiments: replicating historically observed drought properties, generating streamflow scenarios for multiple sites preserving correlation between their drought conditions, and generating a set of scenarios with direct and independent changes in drought properties. FIND source code is openly available for applications beyond the scope of this paper.

42 ENGINEERING↗

Data-Informed Synthetic Networks of Water Distribution Systems for Resilience Analysis in Puerto Rico

The increasing potential of infrastructure disruptions calls for high-quality infrastructure models to be used in resilience analysis and decision making. Unfortunately, many utilities and communities do not have access to accurate and detailed models due to a lack of data and resources. Furthermore, security restrictions on sharing infrastructure models present roadblocks to research, analysis, and decision making. Recent advances in the development of synthetic water distribution models provide a potential solution to this problem. There is an opportunity to improve these methods by leveraging incomplete pipe datasets to aid synthetic network generation. To address this gap, we developed a methodology for synthetic network generation that incorporates partial pipe data using a modification of the minimum cost flow algorithm for network generation and pipe sizing. This methodology demonstrates how partial pipe data can be leveraged to improve site-specific synthetic network generation. For the study area of Mayagüez, Puerto Rico, a synthetic model generated using 50% of real pipe data matches the pressure of the validation system with an average error of 23.5 m of head, which improves upon the average error of 31.6 m of head produced by a synthetic model generated using no data of the real pipes. Additionally, synthetic networks are shown to replicate the pressure response under a disruption scenario of the validation network, suggesting potential use in resilience analysis.

resilience analysis↗

Role of heterogeneous surface wettability on dynamic immiscible displacement, capillary pressure, and relative permeability in a CO 2 -water-rock system

Numerical examination of CO 2 displacement in brine filled rock pores with varying wettability. Results show that as the CO 2 contact angles on the rock surface increased (intermediate water wetting conditions) negative entry pressures for CO 2 displacement were observed, indicating that when heterogeneous surface wettability is accounted for, greater mobility of CO 2 into rock pores is expected. In addition, simulated relative permeability CO 2 curves with heterogeneous intermediate water wetting conditions exhibited a greater amount of variation, indicative of a complex interrelation of geometric capillary restrictions and surface wettability.

58 GEOSCIENCES↗

U.S. Indirect and Direct Potable Water Reuse Systems (2020)

Collection of proposed, operating, demonstration, and pilot study potable reuse systems across the U.S. as of 2020. Information includes project name, location, augmentation type, capacity, year operational, treatment train, and source water type. References are included in this submission. As potable reuse facilities undergo expansions or upgrades, treatment trains and capacities are subject to change. Operational status may also change. Treatment trains listed are reported to the detail that the source provides. Type and doses of chemical post-treatment or chlorination is often not specified. Please see README section in spreadsheet for definitions of acronyms used.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US Potable Water Reuse System Costs

This submission contains a set of U.S.-specific potable reuse capital and operations and maintenance (O&M) cost data ($2020) found in published presentations and reports from engineering consulting firms, utility and water agency press releases or websites, and literature. For any unbuilt facilities, the reported costs found in technical documents are mostly engineer estimates and may be subject to change as construction proceeds. This data set contains a mix of both facility specific and total capital costs, which include conveyance infrastructure. Note that this dataset does not include detailed cost breakdowns for each of the facilities. This submission also contains the sources used to build this dataset in pdf format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coordination and Planning for Water and Power System Resilience (Workshop Report)

Water and power utilities are interdependent, subject to many of the same natural and manmade hazards, and critical for the well-being of communities and society. In April 2021, a virtual workshop was held that brought together representatives from water, wastewater, and electric utilities; government organizations; water and electricity based professional associations; consulting firms; and researcher organizations to explore water and power system interdependencies and resilience. The workshop, organized by Pacific Northwest National Laboratory (PNNL) and funded by the United States Department of Energy (DOE) Water Power Technologies Office (WPTO), explored a vision for coordinated and resilient water and electric utilities of the future and identified barriers and strategies for increased coordination and integrated planning between water and power utilities. Workshop participants suggested next steps and areas where federal research and support would be beneficial. This report documents that key outcomes of the workshop.

13 HYDRO ENERGY↗

Markov Process to Evaluate the Value Proposition of a Risk-Informed Predictive Maintenance Strategy

To achieve high-capacity factors, the nuclear fleet has relied on labor-intensive and time-consuming operation and preventive maintenance programs for plant systems. Manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies, along with time-based replacement of assets irrespective of condition, have resulted in a costly, labor-centric business model. Fortunately, there are technologies that can eliminate unnecessary preventive maintenance activities by deploying risk-informed predictive maintenance, enabling the transition to a technology-centric business model. The technology-centric business model will enable plants to optimize and automate maintenance activities, leading to cost reductions since labor is a rising cost and technology is a declining cost. The implementation of scalable technologies and methodologies across plant systems and across the nuclear fleet is critical for successful deployment of a risk-informed predictive maintenance strategy at commercial nuclear power plants. The work presented in the report is being developed as part of a collaborative research effort between Idaho National Laboratory and Public Service Enterprise Group Nuclear, LLC. This report describes the technical basis using the Markov Process to evaluate the value proposition for the risk-informed predictive maintenance strategy for the circulating water system. The plant process data from the Salem nuclear plant’s circulating water system is utilized to develop a Markov chain risk models and formulation to estimate the loss and gain in revenue based on plant availability. The outcomes presented in this report provides the technical basis for extensive quantitative evaluation of a scalable risk-informed predictive maintenance strategy as part of future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying schools at high-risk for elevated lead in drinking water using only publicly available data

Estimating the risk of lead contamination of schools' drinking water at the State level is a complex, important, and unexplored challenge. Variable water quality among water systems and changes in water chemistry during distribution affect lead dissolution rates from pipes and fittings. In addition, the locations of lead-bearing plumbing materials are uncertain. We tested the capability of six machine learning models to predict the likelihood of lead contamination of drinking water at the schools' taps using only publicly available datasets. The predictive features used in the models correspond to those with a proven correlation to the dominant, but commonly unavailable, factors that govern lead leaching: the presence of lead-bearing plumbing materials and water quality conducive to lead corrosion. By combining water chemistry data from public reports, socioeconomic information from the US census, and spatial features using Geographic Information Systems, we trained and tested models to estimate the likelihood of lead contaminated tap water in over 8,000 schools across California and Massachusetts. Our best-performing model was a Random Forest, with a 10-fold cross validation score of 0.88 for Massachusetts and 0.78 for California using the average Area Under the Receiver Operating Characteristic Curve (ROC AUC) metric. The model was then used to assign a lead leaching risk category to half of the schools across California (the other half was used for training). There was good agreement between the modeled risk categories and the actual lead leaching outcomes for every school; however, the model overestimated the lead leaching risk in up to 17% of the schools. This model is the first of its kind to offer a tool to predict the risk of lead leaching in schools at the State level. Further use of this model can help deploy limited resources more effectively to prevent childhood lead exposure from school drinking water.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Implications of high-pressure oxygen hydrates on radiolytic oxygen in Jovian icy moons

Various icy moons, such as Europa and Ganymede, have thin oxygen atmospheres and exhibit spectral features attributed to oxygen held in their surface ices. The oxygen forms from the radiolysis of water. The interiors of these bodies are subject to high pressures and it is not known how deep into icy moons oxygen-bearing ices can penetrate, or the structures formed by the oxygen–water system at high pressure. Here, we show that oxygen hydrates are stable to 2.6 GPa, allowing them to penetrate deep into icy moons, both above and below proposed sub-surface liquid-water oceans. Similarities between oxygen and hydrogen hydrates indicate potentially enhanced recombination rates, transforming them back into water and offering a resolution to the discrepancy between predicted and measured radiolysis rates. In addition to the low-pressure CS-II clathrate, our results find three high-pressure phases in the oxygen–water system: an ST clathrate, a C 0 hydrate, and a filled ice isomorphous with methane hydrate III. This shows a vast storage potential for molecular oxygen in icy moons and indicates that Europa could still be absorbing oxygen into its crustal ice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seasonal Host Shifts for Legionella Within an Industrial Water‐Cooling System

Legionella is a genus of environmental bacteria containing pathogenic species such as Legionella pneumophila that are responsible for Legionnaires' disease, a potentially fatal respiratory infection. Disease aetiology can involve Legionella replication intracellularly within protists and this study aimed to characterise the Legionella -protist relationship to develop novel outbreak prevention targets. Water and sediment samples were collected from a water-cooling tower in South Carolina over a 6-month period. Concomitantly, multiple environmental parameters were recorded. Bacterial and eukaryotic communities were characterised using 16S rRNA gene V4 region and a 252 bp fragment of 18S rRNA gene, respectively. Co-occurrence network analyses were performed to elucidate Legionella -protist correlations through time. We found that Legionella correlated with different protists as the seasons progressed. Acanthamoeba correlated with Legionella in early spring followed by Vannella and Korotnevella in late spring and early summer, and were joined by Echinamoeba in mid-summer. Vannella and Acanthamoeba are known potential hosts for Legionella , while Korotnevella is a potential undocumented host. Of the environmental parameters, temperature showed strong correlation with protists genera, suggesting that Legionella abundance was driven by temperature-dependent protist availability. Our results highlight ecological shifts that are associated with elevated Legionella levels, which offers potential targets to help predict and prevent disease outbreaks.

microbial communities↗