Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition

This report builds on the 2016 Water and Wastewater Annual Price Escalation Rates for Selected Cities across the United States report prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP). The 2017 report examined annual water and wastewater price escalation rate trends across the U.S. Annual water and wastewater price escalation rates are an important factor when conducting life-cycle cost analyses (LCCA) of water efficiency measures, which is required for Federal agencies. Following the framework of the 2017 report, PNNL used the American Water Works Association (AWWA) water and wastewater rate surveys to gather historical rate data for water and wastewater utilities in the US, which were used to calculate a sample set of water and wastewater annual price escalation rates (Figure E.1). An annual price escalation rate was calculated for 113 water utilities and 76 wastewater utilities that reported at least two AWWA surveys across the past 13 years (i.e., 2008 to 2021) and at least a five-year range between those two surveys. Statistical trends in the annual price escalation rates are also provided by the seven regions identified in Figure E.1. In the 2017 report, the average annual price escalation for the surveyed sample of water and wastewater rates were 3.0% and 3.2%, respectively. This report also calculated aggregate average annual price escalation rates for the surveyed sample of water and wastewater utilities to be 3.1% and 2.7%, respectively. These escalation rates were based on 87 water utilities and 46 wastewater utilities that reported data in at least two AWWA surveys with at least a five-year range between those two surveys and reported at least one AWWA survey in 2019 or 2021. Among water utilities, the highest average annual price escalation rate was 8.8%, and the highest average annual water de-escalation rate was -2.0%. And for wastewater utilities, the highest average annual wastewater price escalation rate was 10.2%, and the highest average annual wastewater de-escalation rate was -2.3%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Incorporation of Ion Transport Chains into Multivariate MOF for Improved Water Oxidation

The climate crisis demands clean energy technologies to cut CO 2 emissions from fossil fuels. Hydrogen fuel cells and solar-driven CO 2 reduction are promising, but both rely on efficient water oxidation. Polypyridyl ruthenium complexes are active catalysts for water oxidation; however, they exhibit poor stability and recyclability. Our group improved performance by embedding these complexes into metal−organic frameworks (MOFs). As water oxidation is pH-dependent, proton management further enhances reactivity. To address the issue, we introduced proton transfer pathways into the MOF structure. Specifically, we incorporated −SO 3 H groups onto the biphenyl linkers of UiO-67 loaded with [Ru(tpy)(dcbpy)OH 2 ]PF 6 catalyst (where tpy = 2,2′:6′,2″-terpyridine; dcbpy = 5,5-dicarboxy-2,2′- bipyridine). The sulfonated MOF exhibited a 2.5-fold increase in oxygen evolution compared to the nonsulfonated analogue. After 1 h of electrolysis, the sulfonated MOF exhibited a turnover number of 25 for oxygen evolution reaction compared to 10 for the native MOF, demonstrating the benefits of built-in proton management.

Catalysts↗

Phenotyping stomatal closure by thermal imaging for GWAS and TWAS of water use efficiency-related genes

Abstract Stomata allow CO2 uptake by leaves for photosynthetic assimilation at the cost of water vapor loss to the atmosphere. The opening and closing of stomata in response to fluctuations in light intensity regulate CO2 and water fluxes and are essential for maintaining water-use efficiency (WUE). However, a little is known about the genetic basis for natural variation in stomatal movement, especially in C4 crops. This is partly because the stomatal response to a change in light intensity is difficult to measure at the scale required for association studies. Here, we used high-throughput thermal imaging to bypass the phenotyping bottleneck and assess 10 traits describing stomatal conductance (gs) before, during and after a stepwise decrease in light intensity for a diversity panel of 659 sorghum (Sorghum bicolor) accessions. Results from thermal imaging significantly correlated with photosynthetic gas exchange measurements. gs traits varied substantially across the population and were moderately heritable (h2 up to 0.72). An integrated genome-wide and transcriptome-wide association study identified candidate genes putatively driving variation in stomatal conductance traits. Of the 239 unique candidate genes identified with the greatest confidence, 77 were putative orthologs of Arabidopsis (Arabidopsis thaliana) genes related to functions implicated in WUE, including stomatal opening/closing (24 genes), stomatal/epidermal cell development (35 genes), leaf/vasculature development (12 genes), or chlorophyll metabolism/photosynthesis (8 genes). These findings demonstrate an approach to finding genotype-to-phenotype relationships for a challenging trait as well as candidate genes for further investigation of the genetic basis of WUE in a model C4 grass for bioenergy, food, and forage production.

54 ENVIRONMENTAL SCIENCES↗

Poly(ether‐block‐amide) membrane with deformability and adjustable surface hydrophilicity for water purification

Abstract Freshwater resources are currently insufficient, and another form of freshwater resources, namely, ice, is very interesting except for the issue of how to use new materials for effective purification during the processing procedure. In this article, a new membrane material with multisize pore structure in the cross‐section and intact thin skin layer on the upper and lower surfaces was successfully prepared by adding porogen, filler and setting heating environment during the phase separation process. The membrane exhibits excellent axial deformability, and its elongation at break can reach to 160% strain. Meanwhile, they all show elastic deformation behavior in the range from −60 to 100°C. Even if high content of hydrophobic filler is compounded into these membranes, that is, 5.7 wt% carbon tube content, water contact angle of membrane's surface is only 72.5°, demonstrating obvious hydrophilicity. In addition, in the water purification process, the adsorption rate constant reached ideal value of 0.26 s −1 , and the equilibrium adsorption capacity was about 2.8 g/g, showing fast and efficient water purification ability. In the mode of external heating source or the membrane's heat dissipation, these prepared membranes can melt the ice to obtain purified water and exhibit a controllable purification ability in this process.

Ge, Chengbiao↗

Free-standing membrane incorporating single-atom catalysts for ultrafast electroreduction of low-concentration nitrate

The release of wastewaters containing relatively low levels of nitrate (NO 3 ⁻) results in sufficient contamination to induce harmful algal blooms and to elevate drinking water NO 3 ⁻ concentrations to potentially hazardous levels. In particular, the facile triggering of algal blooms by ultra-low concentrations of NO 3 ⁻ necessitates the development of efficient methods for NO 3 ⁻ destruction. However, promising electrochemical methods suffer from weak mass transport under low reactant concentrations, resulting in long treatment times (on the order of hours) for complete NO 3 ⁻ destruction. In this study, we present flow-through electrofiltration via an electrified membrane incorporating nonprecious metal single-atom catalysts for NO 3 ⁻ reduction activity enhancement and selectivity modification, achieving near-complete removal of ultra-low concentration NO 3 ⁻ (10 mg-N L -1 ) with a residence time of only a few seconds (10 s). By anchoring Cu single atoms supported on N-doped carbon in a carbon nanotube interwoven framework, we fabricate a free-standing carbonaceous membrane featuring high conductivity, permeability, and flexibility. The membrane achieves over 97% NO 3 ⁻ removal with high N 2 selectivity of 86% in a single-pass electrofiltration, which is a significant improvement over flow-by operation (30% NO 3 ⁻ removal with 7% N 2 selectivity). This high NO 3 ⁻ reduction performance is attributed to the greater adsorption and transport of nitric oxide under high molecular collision frequency coupled with a balanced supply of atomic hydrogen through H 2 dissociation during electrofiltration. Overall, our findings provide a paradigm of applying a flow-through electrified membrane incorporating single-atom catalysts to improve the rate and selectivity of NO 3 ⁻ reduction for efficient water purification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Body water handling in response to hypertonic-saline induced diuresis in fasting northern elephant seal pups (Mirounga angustirostris)

During natural fasting conditions in postweaned northern elephant seal (NES) (Mirounga angustirostris) pups, urinary water loss is minimized and percent total body water (TBW) is maintained constant. However, following infusion of hypertonic saline, glomerular filtration rate (GFR) and urine output increased in fasting pups. Therefore, we quantified the magnitude of the hypernatremia-induced diuresis relative to the animal's total body water (TBW) pool and the percentage of filtered water reabsorbed. Following a 24 h control period, naturally fasting NES pups (n=7) were infused (4 ml min(-1)) with hypertonic saline (16.7%) at a dose of 3 mmol NaCl kg(-1) body mass. Total body water was estimated prior to infusion by tritium dilution, GFR was estimated by standard creatinine clearance, and urine output (V) was measured for 24 h during the control and post infusion periods. Percentage of filtered water reabsorbed was calculated as (1-(V/GFR))x100. Twenty-four hours following the infusion, GFR (control: 69+/-12 ml min(-1) and post-infusion: 118+/-19 ml min(-1); mean+/-S.E.) increased 77+/-28% above control and the percentage of filtered water reabsorbed was decreased 0.4+/-0.1%. The increase in urine output (control: 218+/-47 ml d(-1) and post-infusion: 883+/-92 ml d(-1)) accounted for 1.7+/-0.2% of the pups' TBW. The hypernatremia-induced diuresis was accompanied by the loss of body water indicating the lack of water retention. Although the 77% increase in GFR was only associated with a 0.4% decrease in the percentage of filtered water reabsorbed, this decrease was significant enough to result in a 4-fold increase in urine output. Despite the observed diuresis, fasting NES pups appear to possess an efficient water recycling mechanism requiring only a small percentage of body water to excrete an excess salt load. This water recycling mechanism may allow pups to avoid negative perturbations in body water as they initiate feeding in a marine environment following the fast.

Non-NASA Center↗

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

Traction-separation response of bilayer graphene interfaces: The role of an intercalated single atomic layer of water molecules and hydroxyl groups

Molecular dynamics simulations of the normal and shear traction-separation response of dry and wet bilayer graphene interfaces were performed. The influence of a single, atomic layer of water molecules sandwiched between graphene layers and hydroxyl functionalization on one or both layers were investigated. Hydroxyl groups provided a shielding effect during normal separation while favoring stick-slip friction under sliding conditions. The single, atomic layer of water molecules confined between hydrophilic and asymmetric hydrophobic/hydrophilic surfaces was found to ease sliding friction. The mechanisms arose from the balance between the attractive and repulsive graphene/water interactions through bridges of single water molecules between the two surfaces and the structure of the water monolayer under confinement for which an out-of-plane water/water hydrogen bond network could not be developed. The single, atomic layer of water molecules reduced the sliding friction the most when both surfaces were hydrophilic and lowered the sliding friction of the asymmetric hydrophobic/hydrophilic interfaces to that when both surfaces were hydrophobic. An optimal hydroxyl surface coverage of less than 10% may exist for efficient water lubrication, with diminishing effect with increasing number of hydroxyl groups. Finally, the findings offer a design strategy for assembling bilayer graphene interfaces with tailored friction and sliding contact properties.

36 MATERIALS SCIENCE↗

Evaluating Acoustic vs. AI-Based Satellite Leak Detection in Aging US Water Infrastructure: A Cost and Energy Savings Analysis

The aging water distribution system in the United States, constructed mainly during the 1970s with some pipes dating back 125 years, is experiencing significant deterioration leading to substantial water losses. Along with the potential for water loss savings, improvements in the distribution system by using leak detection technologies can create net energy and cost savings. In this work, a new framework has been presented to calculate the economic level of leakage within water supply and distribution systems for two primary leak detection technologies (acoustic vs. satellite). In this work, a new framework is presented to calculate the economic level of leakage (ELL) within water supply and distribution systems to support smart infrastructure in smart cities. A case study focused using water audit data from Atlanta, Georgia, compared the costs of two leak mitigation technologies: conventional acoustic leak detection and artificial intelligence–assisted satellite leak detection technology, which employs machine learning algorithms to identify potential leak signatures from satellite imagery. The ELL results revealed that conducting one survey would be optimum for an acoustic survey, whereas the method suggested that it would be expensive to utilize satellite-based leak detection technology. However, results for cumulative financial analysis over a 3-year period for both technologies revealed both to be economically favorable with conventional acoustic leak detection technology generating higher net economic benefits of USD 2.4 million, surpassing satellite detection by 50%. A broader national analysis was conducted to explore the potential benefits of US water infrastructure mirroring the exemplary conditions of Germany and The Netherlands. Achieving similar infrastructure leakage index (ILI) values could result in annual cost savings of $\$4$–$\$4.8$ billion and primary energy savings of 1.6–1.9 TWh. These results demonstrate the value of combining economic modeling with advanced leak detection technologies to support sustainable, cost-efficient water infrastructure strategies in urban environments, contributing to more sustainable smart living outcomes.

acoustic leak detection↗

The role of height–driven constraints and compensations on tree vulnerability to drought

Frequent observations of higher mortality in larger trees than in smaller ones during droughts have sparked an increasing interest in size–dependent drought–induced mortality. However, the underlying physiological mechanisms are not well understood, with height–associated hydraulic constraints often being implied as the potential mechanism driving increased drought vulnerability. Here we performed a quantitative synthesis on how key traits that drive plant water and carbon economy change with tree height within species and assessed the implications that the different constraints and compensations may have on the interacting mechanisms (hydraulic failure, carbon starvation and/or biotic–agent attacks) affecting tree vulnerability to drought. While xylem tension increases with tree height, taller trees present a range of structural and functional adjustments, including more efficient water use and transport and greater water uptake and storage capacity, that mitigate the path–length–associated drop in water potential. These adaptations allow taller trees to withstand episodic water stress. Conclusive evidence for height–dependent increased vulnerability to hydraulic failure and carbon starvation, and their coupling to defence mechanisms and pest and pathogen dynamics, is still lacking. Further research is needed, particularly at the intraspecific level, to ascertain the specific conditions and thresholds above which height hinders tree survival under drought.

54 ENVIRONMENTAL SCIENCES↗

Evapotranspiration as a Regional Climate Priority: Results from a NASA/USDA Workshop

On April 5 to 7, 2011, the National Aeronautics and Space Administration (NASA) and the United States Department of Agriculture-Agricultural Research Service (USDA-ARS) sponsored a Workshop on Evapotranspiration (ET) in Silver Spring Maryland. The workshop was a response to a recommendation in the 2009-2011 GEO (Group on Earth Observations) Work Plan that a workshop on ET should be held to discuss issues related to ET products and services and the potential for incorporating ET activities into the 2012-2015 GEO Work Plan. The workshop had a regional emphasis, although there were several excellent international and global presentations including one on the GEWEX LANDFLUX project. The different scales of these activities suggests that a framework is needed that can accommodate both regional and global ET activities. Despite limitations with the workshop's scheduling, it attracted 76 experts who contributed informative presentations and insightful discussions. The goals of the workshop involved the exchange of information and ideas and the development of plans for providing more visibility for ET issues. Specific objectives included 1) defining the needs and requirements for evapotranspiration data in weather and climate studies, in natural and agro-ecoystem monitoring, and in water resource management; 2) reviewing the methods used to measure and model evapotranspiration; 3) assessing surface and satellite observation systems required to support ET measurement, modeling and evaluation; 4) assessing the feasibility of developing a proposal for a task on evapotranspiration for the 2012-2015 GEO Work Plan, and 5) exploring the level of support and consensus for developing a strategy for establishing evapotranspiration as an Essential Climate Variable (ECV) within the Global Climate Observing System (GCOS) framework The workshop featured a combination of oral presentations and breakout group sessions focused on the above objectives. There were also poster presentations providing opportunities for one-on-one discussions of ET modeling and measurement techniques. Presentations by users of ET data set the tone for the workshop. In the USA at the national and regional levels water rights issues represent a major opportunity for ET applications. ET data play a major role in estimating water loss due to irrigation, the largest cause of consumptive water loss in the USA, particularly in the West. Irrigation requirements are relatively specific since the needs are clearly defined by the geometry and number of the irrigation systems and can be monitored with high resolution satellite data. There was a strong consensus that land surface temperature (LST) at high resolution is critical for monitoring irrigation. State governments have made commitments to more efficient water management in the western US, but they need full access to improved and more timely ET data and applications to implement this plan. Water managers also reported that in spite of the recent development of. new techniques, the procedures used in some of the water balance calculations in some states are out of date and do not take advantage of new observational and data assimilation systems. The development of ET forecasts for water management is also seen as a priority. Although ET forecasts are currently being produced on an experimental basis these predictions could be improved by considering ET as a dynamic prediction variable in models and by increasing the time resolution of these ET predictions.

Lawford, Richard↗

Performance Assurance Planning Guide for Utility Energy Service Contracts: 2025 Edition

Administered by the U.S. Department of Energy's (DOE) Federal Energy Management Program (FEMP), the Utility Program has fostered collaboration among federal agencies and their serving utilities for more than 25 years. The Utility Program supports agencies using Utility Energy Service Contracts (UESCs), a well-developed, effective contracting vehicle that enable the latest approaches to cost-effective energy management at federal sites. Federal agencies have successfully used UESCs to award over 2,000 energy and water efficiency and renewable energy projects, investing approximately $\$$2.8 billion in furthering the Federal Government's efforts to reduce energy intensity. Authorized by 42 U.S. Code section 8256 (10 U.S. Code section 2913 for the Department of Defense), a UESC is a limited-source acquisition between a federal agency and an eligible serving utility for energy management services that generate savings from the implementation of energy- and water -conservation measures (collectively referred to as ECMs), with 42 U.S. Code section 8287 (Defense Federal Acquisition Regulation Supplement, Part 241), providing the term of a UESC, which may extend up to 25 years. Through a UESC, the utility partner assesses designs, and implements the desired ECMs - which can range from lighting retrofits and renewable energy systems, to combined heat and power plants or other technologies and strategies, and may provide financing for the project. The agency may use any combination of appropriations and third-party financing to pay for the project, providing useful flexibility. There is no limit to the project size, big or small, that can be implemented using a UESC. To assist agencies implementing a UESC, FEMP has developed a Utility Energy Service Contract Guide and this companion guidance document to help agencies and their utility partners better understand the best practices for to ensure UESCs continue to perform and generate savings throughout their performance period. These best practices utilize a combination of effective project management, communication, documentation, and a detailed Performance Assurance Plan. This plan is a project specific set of actionable protocols that define important tasks and responsibilities throughout the contract term and reflects the site conditions, complexities, agency capabilities, and operating and maintaining planned ECMs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review of Dew Point Evaporative Cooling Technology for Air Conditioning Applications

Indirect evaporative cooling has the potential to significantly improve the natural environment. It follows from a significant reduction in electricity consumption in the hot period, and hence lower operating costs for cooling systems. This paper presents the current state of knowledge and research directions on dew point indirect evaporative cooling. It was found that researchers focus on the development of dew point indirect evaporative coolers (DPIEC) by improving its design, geometry, water distribution, and new porous materials implementation. To evaluate the performance of new types of DPIEC, different methods are used by the scientists. Finally, optimized devices are studied in terms of their performance in different systems, like hybrid and desiccant systems, considering different climate conditions. Potential directions of development of evaporative technologies were indicated, such as increasing the coefficient of performance of solid desiccant evaporative cooling systems, developing novel geometry, and efficient water distribution, including development of porous materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical modeling of ion transport and adsorption in porous media: A pore-scale study for capacitive deionization desalination

In this report a pore-scale model is presented to simulate the dynamic ion transport and adsorption processes in porous electrodes used for capacitive deionization (CDI). The Stokes equation governing water flow is solved using the lattice Boltzmann method and Nernst-Planck equation describing ion transport is solved using the finite volume method. The ion adsorption process is considered at the surface of carbon electrodes. After validation against analytical solutions and published results, the model is used to study the coupled water flow, ion transport and adsorption in both two-dimensional and three-dimensional porous CDI electrodes at the pore scale. The effect of electrode microstructure, electrical potential and flow velocity on the adsorption processes is quantitatively investigated, and the relative importance of various parameters is determined. The presented model can be a powerful numerical tool to quantitatively analyze ion transport and adsorption in porous electrodes, and may provide useful information for the design and optimization of CDI electrodes and operating conditions for desired desalination efficiency, water throughput and cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biogeochemical Fluxes for Three Bioenergy Crops

Perennial crops have been the focus of bioenergy research and development for their sustainability benefits associated with high soil carbon (C) and reduced nitrogen (N) requirements. However, perennial crops mature over several years and their sustainability benefits can be negated through land reversion. A photoperiod‐sensitive energy sorghum (Sorghum bicolor) may provide an annual crop alternative more ecologically sustainable than maize (Zea mays) that can more easily integrate into crop rotations than perennials, such as miscanthus (Miscanthus × giganteus). This study presents an ecosystem‐scale comparison of C, N, water and energy fluxes from energy sorghum, maize and miscanthus during a typical growing season in the Midwest United States. Gross primary productivity (GPP) was highest for maize during the peak growing season at 21.83 g C m−2 day−1, followed by energy sorghum (17.04 g C m−2 day−1) and miscanthus (15.57 g C m−2 day−1). Maize also had the highest peak growing season evapotranspiration at 5.39 mm day−1, with energy sorghum and miscanthus at 3.81 and 3.61 mm day−1, respectively. Energy sorghum was the most efficient water user (WUE), while maize and miscanthus were comparatively similar (3.04, 1.75 and 1.89 g C mm−1 H2O, respectively). Maize albedo was lower than energy sorghum and miscanthus (0.19, 0.26 and 0.24, respectively), but energy sorghum had a Bowen ratio closer to maize than miscanthus (0.12, 0.13 and 0.21, respectively). Nitrous oxide (N2O) flux was higher from maize and energy sorghum (8.86 and 12.04 kg N ha−1, respectively) compared with miscanthus (0.51 kg N ha−1), indicative of their different agronomic management. These results are an important first look at how energy sorghum compares to maize and miscanthus grown in the Midwest United States. This quantitative assessment is a critical component for calibrating biogeochemical and ecological models used to forecast bioenergy crop growth, productivity and sustainability.

Field Data↗