Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage and current controllers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Voltage Support With PV Inverters in Low-Voltage Distribution Networks: An Overview

Large solar photovoltaic (PV) penetration using inverters in low voltage (LV) distribution networks may pose several challenges, such as reverse power flow and voltage rise situations. These challenges will eventually force grid operators to carry out grid reinforcement to ensure continued safe and reliable operations. However, smart inverters with reactive power control capability enable PV systems to support voltage quality in the distribution network better. Here, this paper gives an overview of the current state-of-the-art control strategies for handling voltage problems through PV inverters and other devices. In addition, the (control) technical issues of PV systems integrated into the LV distribution network are considered from a control point of view. By comparing the control issues of PV integration into the grid, the paper aims to help distribution system operators to expand the volume of PV generation in the distribution system in an efficient and safe manner. Additionally, it will help control engineers and researchers select proper control strategies for PV systems as well as other distributed renewable sources.

42 ENGINEERING↗

Voltage reapplication rate control for commutation of thyristors

A circuit for commutating a thyristor (21) by shunting its current for a minimum interval, thereby removing sustaining voltage to said thyristor, then subsequently restoring voltage to said thyristor at a predetermined rate, utilizes a series combination of a commutation electronic switch (22) and an isolated dc voltage supply (23) connected in parallel with the thyristor. The voltage supply is arranged with a polarity that permits the current flowing through the thyristor in one direction to be bypassed through the series combination while the commutation switch is turned on and to reverse bias the thyristor when the commutation switch is fully on. A dv/dt control circuit (24) limits the rate of rise of voltage across the commutation switch (22) as it is turned off in response to a command input signal. The dv/dt control circuit is comprised of a constant current drive (31) and a capacitor (32) connected between the output terminal of the commutation switch and the control input terminal of the commutation switch. The thyristor may be a triac (40) with two commutation switches (42, 43), one for current of each polarity, or with a single commutation switch (55) and a bridge circuit (52-55) for selecting the polarity of the switch (56).

Rippel, Wally E.↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Constant-voltage drive current-steering switch

Two-element voltage control system regulates a magnetic switch consisting of dual ferrite-core shift registers. The system has a magnetic, two-core-per-bit, voltage-controlled shift register.

Caplette, R. K.↗

Hierarchical Control of Distributed Battery Energy Storage System in a DC Microgrid

This paper presents a novel hierarchical control approach of a DC microgrid (DCMG) which is supplied by a distributed battery energy storage system (BESS). With this approach, all battery units distributed in the BESS can be controlled to discharge with accurate current sharing and state-of-charge (SoC) balancing. Similar to other hierarchical control approaches used in DCMGs, this approach consists of three levels: (1) primary control, (2) secondary control and (3) tertiary control. This work includes defining a unit control error (UCE) at the secondary control level and evaluating current sharing weights at tertiary control level. A centralized controller at secondary control level is designed to detect the UCEs of each battery unit, and to restore the average voltage of a DCMG and control battery current sharing simultaneously. The distributed battery units share the load current in a DCMG based on weights. These weights are evaluated at the tertiary control level based on battery SoCs. The approach’s effectiveness was confirmed in digital simulation tests with the same simulation model as used in the NASA AMPS Modular Hardware Emulator.

Jing Zhang↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Cathode degradation and erosion in high pressure arc discharges

The various processes which control cathode erosion and degradation were identified and evaluated. A direct current arc discharge was established between electrodes in a pressure-controlled gas flow environment. The cathode holder was designed for easy testing of various cathode materials. The anode was a water cooled copper collector electrode. The arc was powered by a dc power supply with current and voltage regulated cross-over control. Nitrogen and argon were used as propellants and the materials used were two percent thoriated tungsten, barium oxide impregnated porous tungsten, pure tungsten and lanthanum hexaboride. The configurations used were cylindrical solid rods, wire bundles supported by hollow molybdenum tubes, cylindrical hollow tubes, and hollow cathodes of the type used in ion thrusters. The results of the mass loss tests in nitrogen indicated that pure tungsten eroded at a rate more than 10 times faster than the rates of the impregnated tungsten materials. It was found that oxygen impurities of less than 0.5 percent in the nitrogen increased the mass loss rate by a factor of 4 over high purity nitrogen. At power levels less than 1 kW, cathode size and current level did not significantly affect the mass loss rate. The hollow cathode was found to be operable in argon and in nitrogen only at pressures below 400 and 200 torr, respectively.

Hardy, T. L.↗

Cathode degradation and erosion in high pressure arc discharges

The various processes which control cathode erosion and degradation were identified and evaluated. A direct current arc discharge was established between electrodes in a pressure-controlled gas flow environment. The cathode holder was designed for easy testing of various cathode materials. The anode was a water cooled copper collector electrode. The arc was powered by a dc power supply with current and voltage regulated cross-over control. Nitrogen and argon were used as propellants and the materials used were two percent thoriated tungsten, barium oxide impregnated porous tungsten, pure tungsten and lanthanum hexaboride. The configurations used were cylindrical solid rods, wire bundles supported by hollow molybdenum tubes, cylindrical hollow tubes, and hollow cathodes of the type used in ion thrusters. The results of the mass loss tests in nitrogen indicated that pure tungsten eroded at a rate more than 10 times faster than the rates of the impregnated tungsten materials. It was found that oxygen impurities of less than 0.5 percent in the nitrogen increased the mass loss rate by a factor of 4 over high purity nitrogen. At power levels less than 1 kW, cathode size and current level did not significantly affect the mass loss rate. The hollow cathode was found to be operable in argon and in nitrogen only at pressures below 400 and 200 torr, respectively.

Hardy, T. L.↗

Measurement and modeling of the radio frequency sheath impedance in a large magnetized plasma

The DC and RF properties of radio frequency (RF) driven sheaths were studied in the Large Plasma Device (LAPD) at the University of California, Los Angeles. The experiments diagnosed RF sheaths on field lines connected to a grounded plate at one end and an ion cyclotron range of frequencies (ICRF) antenna at the other end. The experimental setup permitted measurement of the RF sheath impedance at the plate as a function of DC sheath voltage, with the latter controlled by varying the RF current applied to the antenna. Here, the DC current-voltage characteristics of these sheaths and the RF sheath impedance measurements were compared with modeling. Hot electrons, present in the LAPD plasma, were inferred to contribute significantly to both the DC and RF currents and hence the RF impedance. It was postulated that at very low power hot electrons could not access the region of the plasma subject to RF waves, resulting in an increased RF impedance. Within some experimental limitations and significant assumptions, an RF sheath impedance model was verified by the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar bus regulator and battery charger for IMP's H, I, and J

Interplanetary Monitoring Probe (IMP) spacecrafts H, I, and J utilize a direct energy transfer (DET) type of power system operating from a solar array source. A shunt type of regulator prevents the bus voltage from exceeding a preset voltage level. The power system utilizes a single differential amplifier with dual outputs to control the battery charge/shunt regulator and the discharge regulator. A two-voltage level, current limited, series charger and a current sensor control battery state of charge of the silver-cadmium battery pack. Premature termination of the battery charge is prevented by a power available gate that also initiates charge current to the battery upon availability of excess power.

Paulkovich, J.↗

Control and protection system for paralleled modular static inverter-converter systems

A control and protection system was developed for use with a paralleled 2.5-kWe-per-module static inverter-converter system. The control and protection system senses internal and external fault parameters such as voltage, frequency, current, and paralleling current unbalance. A logic system controls contactors to isolate defective power conditioners or loads. The system sequences contactor operation to automatically control parallel operation, startup, and fault isolation. Transient overload protection and fault checking sequences are included. The operation and performance of a control and protection system, with detailed circuit descriptions, are presented.

Birchenough, A. G.↗

Structured Neural Network Modeling for Developing Digital Twins Models of Hydropower Generation Units

Dynamic modeling is a key part in the development of digital twin (DT) for dynamic systems. This is true for hydropower systems, where whole system modeling including penstock, turbine and generators, etc is important in realizing actuate modeling for the real systems. On the other hand, in response to the large variations of the power demand due to increased penetration of renewables such as wind and solar, hydropower systems are now required to operate in a large power generation range. This situation triggers the nonlinear characteristics of the generation unit with respect to its models. As such, it is imperative to use data driven modeling such as neural networks to learn the nonlinear dynamics of the hydropower generation unit. To achieve this objective, this study constructs a modeling and learning algorithm integrated with multiple structured neural network models for the modeling of turbine shaft speed, penstock pressure, and generator power output based on the generator power control setpoint, field current, and field voltage. In addition, the study uses the hydropower data from Tacoma Public Utilities to train and validate the proposed neural network algorithm. The results have shown that this structured neural network modeling approach can learn the system dynamics effectively by using the real-time data collected from the hydropower system with the desired modeling results.

Wang, Hong↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

Power Matching of an Ion Thruster to Solar Cell Power Output

A 20-cm-diam thruster was operated over a 2:1 range of output power, allowing for continuous matching of thruster power to a varying solar cell output level. The technique of matching power by varying either the ion beam current or the net accelerating voltage is described. Ion beam current control, implemented in thruster control loops, utilized existing laboratory hardware. Stable thruster operation was achieved over a range of 1000 to 2000 W. Bistable values of mercury propellant flow at the same discharge chamber and ion beam conditions were also observed.

Pawlik, Eugene V.↗

Arc termination cracks in Inconel 718 and Incoloy 903

The welding of the nickel base, heat resistant alloys that are used extensively for welded Shuttle engine components revealed solidification cracking characteristics at weld termination points. If not detected and removed, these crater cracks may cause costly component failure. To better understand this characteristic, welding termination techniques were studied and methods developed to eliminate crater cracks. It was determined that weld termination solidification cracking can be eliminated by controlled decrease of welding current, welding voltage, wire feed, and travel speed.

Bayless, E.↗

Development of a Solid State Power Switch for the Cassini Spacecraft

The Cassini spacecraft uses a new hybrid device to replace the load switching relays used on previous missions. These hybrid devices provide additional functions such as circuit breaking, controlled voltage turn-on and current limiting features. The current limiting function makes an uninterruptible power system possible. This hybrid, the Solid State Power Switch (SSPS), performs the function of connecting the 192 Cassini loads to the spacecraft power bus in response to commands from the Command and Data subsystem.

Cassini↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗