Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

In-Vessel Retention of Molten Corium: Lessons Learned and Outstanding Issues

In-vessel retention (IVR) of core melt is a key severe accident management strategy adopted by some operating nuclear power plants and proposed for some advanced light water reactors (ALWRs). If there were inadequate cooling during a reactor accident, a significant amount of core material could become molten and relocate to the lower head of the reactor vessel, as happened in the Three Mile Island Unit 2 (TMI-2) accident. If it is possible to ensure that the vessel head remains intact so that relocated core materials are retained within the vessel, the enhanced safety associated with these plants can reduce concerns about containment failure and associated risk. For example, the enhanced safety of the Advanced 600 MWe Pressurized Water Reactor (PWR) designed by Westinghouse (AP600), which relied upon External Reactor Vessel Cooling (ERVC) for IVR, resulted in the U.S. Nuclear Regulatory Commission (US NRC) approving the design without requiring certain conventional features common to existing Light Water Reactors (LWRs). However, it is not clear that the ERVC proposed for the AP600 could provide sufficient heat removal for higher-power reactors (up to 1500 MWe) without additional enhancements. This paper reviews efforts made and results reported regarding the enhancement of IVR in LWRs. Where appropriate, the paper identifies what additional data or analyses are needed to demonstrate that there is sufficient margin for successful IVR in high power thermal reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dll4-Notch1 signaling but not VEGF-A is essential for hyperoxia induced vessel regression in retina

Highlights: • Our study find that VEGF-A is not an indispensable factor in hyperoxia induced vessel regression. • Hyperoxia exposure inactivated Dll4-Notch1 signaling in vessel regression region. • Inhibition of Dll4-Notch1 signaling by short-time administration of Dll4 neutralizing antibodies or DAPT exaggerates hyperoxia induced vascular regression. It is well recognized that decreased vascular endothelial growth factor A (VEGF-A) mRNA plays an important role in retinal vessel regression induced by hyperoxia. However, this concept has been challenged by increasing new evidence. Furthermore, VEGF-A strongly enhances Dll4 expression and inhibition of Dll4-Notch signaling leads to excessive sprouting angiogenesis. Recently, it is shown that inactivation of Dll4-Notch1 signaling reduce hyperoxia induced vessel regression. It is unknown whether sprouting angiogenesis contributes to the protective effect or not and further investigations are needed. Moreover, the expression of Dll4 or Notch1 activation in the regressing plexus remains elucidated. To determine the role of VEGF-A and Dll4-Notch1 signaling in hyperoxia induced vascular regression in the retina, we used mice at postnatal day 5 (P5) - P7. Hyperoxia induced massive vascular regression in the central plexus but not in the angiogenic plexus and had no effect on sprouting angiogenesis. Immunostaining showed that VEGF-A was significantly repressed in the angiogenic front region after hyperoxia exposure but not detectable in the central area of both normoxia and hyperoxia treated retinas. In contrast, Notch ligand Delta-like 4 (Dll4) and Notch1 intracellular domain (N1-ICD) expression were inhibited in the regressing capillaries of central retina but comparable in the angiogenic plexus after high oxygen treatment. Moreover, administration of Dll4 neutralizing antibody or γ-Secretase inhibitor DAPT significantly aggravated vessel regression induced by short-time hyperoxia administration. Our data show that repressed Dll4-Notch1 signaling pathway but not downregulation of VEGF-A expression are responsible for hyperoxia induced pervasive vessel regression.

60 APPLIED LIFE SCIENCES↗

Liquid hydrogen pump performance and durability testing through repeated cryogenic vessel filling to 700 bar

Here, this paper reports the results of a comprehensive test of liquid hydrogen (LH 2 ) pump performance and durability conducted while cycle testing a prototype thin-lined cryogenic pressure vessel 456 times to 700 bar. This extensive LH2 pump experimental data set provides a wealth of information vital for a complete evaluation of the future potential of this promising technology for ambient temperature and cryo-compressed vessel refueling. The experiment was conducted at Lawrence Livermore National Laboratory (Livermore, CA)'s hydrogen test facility, specifically built for this experiment and including a containment vessel for safe testing of the prototype vessel and a control room for efficient monitoring. Original pump and storage instrumentation was complemented with an electric power analyzer and a boil-off mass flow meter for more complete pump characterization. The results of the experiment confirm most of the expected virtues of the LH 2 pump: rapid (3 min) refueling of the 65-liter prototype vessel at high flow rate (1.55 kgH 2 per minute on average), unlimited back to back refueling, low electricity consumption (1.1 kWh/kg H 2 ), no measurable degradation, and low maintenance. High cryogenic vessel fill density is another key performance metric that was demonstrated in an earlier publication. These virtues derive from the high density of LH 2 enabling pressurization to high density with relatively little energy consumption and high throughput from a small displacement pump. Boil-off losses as high as 27.7% of dispensed hydrogen were measured, at experimental conditions not representative of operation at a hydrogen refueling station. These losses drop to 15.4% for operation that may be representative of a small station (332 kg/day), while we anticipate less than 6% boil-off with the existing pump and Dewar with improved LH 2 delivery truck operations and a more favorable arrangement of the LH 2 pump relative to the Dewar.

08 HYDROGEN↗

The storage performance of automotive cryo-compressed hydrogen vessels

Cryo-compressed hydrogen storage promises to deliver the highest system storage density leading to practical vehicles with range comparable to today's gasoline vehicles and fundamental cost and safety advantages. Yet, cryogenic vessels are complex systems, continuously drifting in thermodynamic space depending on use patterns, insulation performance, vessel characteristics, liquid hydrogen pump performance, and para-H 2 to ortho-H 2 conversion. In this paper, cryogenic vessel fill density results from a previous publication are extended to calculate system storage performance, including volumetric (gH 2 /L), gravimetric (H 2 weight fraction), and vent losses over a broad range of conditions. The results validate previous experiments and models indicating that cryogenic pressure vessels have maximum system density of all available storage technologies while avoiding vent losses in all but the most extreme situations. Design pressures in the range 250–350 bar seem most advantageous due to high system density and low weight and cost, although determining an optimum pressure demands a complete economic and functional analysis. Future insulation, vessel, and liquid hydrogen pump improvements are finally analyzed that, while not experimentally exhibited to date, show promise of being feasible in the future as their level of technical maturity increases, leading to maximum H 2 storage performance for cryo-compressed storage. If proven feasible and incorporated into future cryogenic vessels, these improvements will enable 50 + gH 2 /L system density at 10+% H 2 weight fraction.

08 HYDROGEN↗

Xylem-dwelling pathogen unaffected by local xylem vessel network properties in grapevines ( Vitis spp.)

Abstract Background and aims Xylella fastidiosa (Xf) is the xylem-dwelling bacterium associated with Pierce’s disease (PD), which causes mortality in agriculturally important species, such as grapevine (Vitis vinifera). The development of PD symptoms in grapevines depends on the ability of Xf to produce cell-wall-degrading enzymes to break up intervessel pit membranes and systematically spread through the xylem vessel network. Our objective here was to investigate whether PD resistance could be mechanistically linked to xylem vessel network local connectivity. Methods We used high-resolution X-ray micro-computed tomography (microCT) imaging to identify and describe the type, area and spatial distribution of intervessel connections for six different grapevine genotypes from three genetic backgrounds, with varying resistance to PD (four PD resistant and two PD susceptible). Key results Our results suggest that PD resistance is unlikely to derive from local xylem network connectivity. The intervessel pit area (Ai) varied from 0.07 ± 0.01 mm2 mm−3 in Lenoir to 0.17 ± 0.03 mm2 mm−3 in Blanc do Bois, both PD resistant. Intervessel contact fraction (Cp) was not statically significant, but the two PD-susceptible genotypes, Syrah (0.056 ± 0.015) and Chardonnay (0.041 ± 0.013), were among the most highly connected vessel networks. Neither Ai nor Cp explained differences in PD resistance among the six genotypes. Bayesian re-analysis of our data shows moderate evidence against the effects of the traits analysed: Ai (BF01 = 4.88), mean vessel density (4.86), relay diameter (4.30), relay density (3.31) and solitary vessel proportion (3.19). Conclusions Our results show that radial and tangential xylem network connectivity is highly conserved within the six different Vitis genotypes we sampled. The way that Xf traverses the vessel network may limit the importance of local network properties to its spread and may confer greater importance on host biochemical responses.

Plant Sciences↗

Comparison of Alternatives to the 2004 Vacuum Vessel Heat Transfer System

A study comparing different alternatives for the Vacuum Vessel Primary Heat Transfer System has been completed. Three alternatives were proposed in a Project Change Request (PCR-190) by relocating the heat exchangers (HXs) from the roof of the Tokamak building to inside the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The study evaluated the three alternatives and recommended modifications to one of them to arrive at a preferred configuration that included relocating the HXs inside the Tokamak building but outside the VVPSS tank as well as including a small safety-rated pump and HX in parallel to the main circulation pump and HX. The Vacuum Vessel (VV) Primary Heat Transfer System (PHTS) removes heat generated in the VV during normal operation (10 MW, pulsed power) as well as the decay heat from the VV itself and from the structures/components attached to the VV (first wall, blanket, and divertor {approx}0.48 MW peak). Therefore, the VV PHTS has two safety functions: (1) contain contaminated cooling water (similar to the other PHTSs) and (2) provide passive cooling during an accident event. The 2004 design of the VV PHTS consists of two independent loops, each loop cooling half of the 18 VV segments with a nominal flow of 475 kg/s of water at about 1.1 MPa and 100 C. The total flow for both loops is 950 kg/s. Both loops are required to remove the heat load during normal plasma operation. During accident conditions, only one loop is needed to remove by natural convection (no pump needed) the decay heat of the complete VV and attached components. The heat is transferred to heat exchanger (HXs) located on top of the roof, outside the Tokamak building. These HXs are air-to-water (A/W) HXs. Three alternatives have been proposed for this cooling system. For a detailed discussion of these alternatives, please refer to Project Change Request, PCR-190 (Ref. 1). A brief introduction is given here. Alternative 1 includes only one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump. In addition, this alternative has two natural circulation safety loops. Both the safety and main loops supply water to the bottom of the VV with six branch lines and collect the heated water at the top of the vessel through six branches. The distribution headers are located in the lower pipe chase and the collection headers in the upper pipe chase. Each of these loops (one main and two emergency) has a HX mounted in the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The main HX is cooled using either Component Cooling Water System (CCWS) or Chilled Water System (CHWS) water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 1 taken from PCR-190. Alternative 2 is exactly the same as Alternative 1 except that there is only one emergency loop and one emergency HX. See Fig. 2 taken from PCR-190. Alternative 3 also has one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump and one natural circulation safety loop. In this case, both the safety and main loops supply water to the top of the VV with three branch lines and collect the heated water at the top of the vessel through three branches. Here, the distribution header is located in the upper pipe chase as is the collection header. As before, each of these loops has a HX mounted in the VVPSS tank. The main HX is cooled using either CCWS or CHWS water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 3 taken from PCR-190. The preferred configuration is developed by selecting specific attributes of the other configurations analyzed and the logic for selecting this configuration is discussed at the end of the document. It is a modification of Alternative 2 that eliminates the separate safety loop, but incorporates a small safety rated HX and pump in parallel with the main HX and pump. It uses 18 inlet and 18 outlet branches (as did the 2004 design) and locates the HXs outside of the VVPSS tank. Tables 1 and 2 examine alternatives to the 2004 VV heat transfer system design that were proposed in PCR-190, as well as the preferred option.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LANL Robotic Vessel Scanning

Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

Computer Hardware↗

Iodine Adsorption by Ag-Aerogel under Prototypical Vessel Off-Gas Conditions

U.S. regulations will require the removal of 129 I from the off-gas streams of any used nuclear fuel (UNF) reprocessing plant prior to discharge of the off-gas to the environment. The required plant decontamination factor for iodine will vary based on fuel burnup, cooling time, and other factors but is very likely to be >1000 and could be as high as 8000. Multiple off-gas streams within a UNF reprocessing plant combine prior to environmental release, and each of these streams contains some amount of iodine. To achieve the decontamination factors (DFs) that are likely to be required by regulations, iodine removal from the vessel off-gas will be necessary. The vessel off-gas contains iodine at very dilute concentrations (ppb levels), and will also contain water vapor. Iodine species present are likely to include both elemental and organic iodides. There will also be solvent vapors and volatile radiolysis products. The United States has considered the use of silver-based sorbents for removal of iodine from UNF off-gas streams, but little is known about the behavior of those sorbents at very dilute iodine concentrations. The purpose of this study was to expose silver-functionalized silica aerogel (AgAerogel) to a prototypical vessel off-gas stream containing 40 ppb methyl iodide to obtain information about organic iodine capture by silver-sorbents at very low iodine concentrations. The design of this extended duration testing was such that information about the rate of adsorption, the penetration of the iodine species, and the overall system DF could be obtained. Results show that CH 3 I penetrates into a AgAerogel sorbent bed to a depth of 3.9 cm under prototypical vessel off-gas conditions. An iodine loading of 22 mg I/g AgAerogel was observed in the first 0.3 cm of the bed. Of the iodine delivered to the system, 48% could not be accounted for, and future efforts will investigate this concern. Direct calculation of the decontamination factor is not possible, as no iodine was observed to break through the sorbent beds. Continued studies on the adsorption of iodine from prototypical vessel off-gas streams by silver-based sorbents will attempt to resolve some of the questions raised here, both regarding mass balance and the effect of aging on iodine adsorption by AgAerogel from a dilute gas stream. Additionally, the adsorption of different iodine species, such as I 2 and C 12 H 25 I will be studied. Other variables that merit examination are the gas velocity of the test and the dependence of the observed results on the inlet iodine concentration. Finally, longer duration testing should be considered in an effort to determine the mass transfer zone associated with iodine adsorption by AgAerogel under prototypical vessel off-gas conditions. The estimation of mass transfer zone is required for any future industrial implementation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Multi-physics (Multiphase CFD + MCNP) simulation for generic solution vessel power calculation

The current study aims to predict the steady state power of a generic solution vessel and to develop a corresponding heat transfer coefficient correlation for a Moly99 production facility by conducting a fully coupled multi-physics simulation. A prediction of steady state power for the current application is inherently interconnected between thermal hydraulic characteristics (i.e. Multiphase computational fluid dynamics solved by ANSYS-Fluent 17.2) and the corresponding neutronic behavior (i.e. particle transport solved by MCNP6.2) in the solution vessel. Thus, the development of a coupling methodology is vital to understand the system behavior at a variety of system design and postulated operating scenarios. In this study, we report on the k-effective (keff) calculation for the baseline solution vessel configuration with a selected solution concentration using MCNP K-code modeling. The associated correlation of thermal properties (e.g. density, viscosity, thermal conductivity, specific heat) at the selected solution concentration are developed based on existing experimental measurements in the open literature. The numerical coupling methodology between multiphase CFD and MCNP is successfully demonstrated, and the detailed coupling procedure is documented. In addition, improved coupling methods capturing realistic physics in the solution vessel thermal-neutronic dynamics are proposed and tested further (i.e. dynamic height adjustment, mull-cell approach). As a key outcome of the current study, a multi-physics coupling methodology between MCFD and MCNP is demonstrated and tested for four different operating conditions. Those different operating conditions are determined based on the neutron source strength at a fixed geometry condition. The steady state powers for the generic solution vessel at various operating conditions are reported, and a generalized correlation of the heat transfer coefficient for the current application is discussed. The assessment of multi-physics methodology and preliminary results from various coupled calculations (power prediction and heat transfer coefficient) can be further utilized for the system code validation and generic solution vessel design improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Filament-wound composite vessels material technology

Programs are reviewed that were conducted to establish a technology base for applying advanced fibers or resins to high performance filament-wound pressure vessels for containment of cryogens and high pressure gases. Materials evaluated included boron, graphite, PRD 49-1 and 3/epoxy and S-glass/polyimide composites. Closed-end cylindrical, and oblate spheroid-shaped vessels were fabricated in 4- and 8-inch diameter sizes. Vessels were subjected to single-cycle burst, low-cycle fatigue, and sustained loading tests over a -423 F to room temperature range for epoxy composites and a -423 to 500 F temperature range for the polyimide composites. Vessels tested at cryogenic and/or 500 F had thin (3 to 20 mils) metallic liners whereas vessels tested at room temperature had elastomeric liners. Correlations between acoustic emissions and burst and cyclic properties of PRD 49-1 filament-wound vessels are discussed.

Lark, R. F.↗

Acoustic emission testing of 12-nickel maraging steel pressure vessels

Acoustic emission data were obtained from three point bend fracture toughness specimens of 12-nickel maraging steel, and two pressure vessels of the same material. One of the pressure vessels contained a prefabricated flaw which was extended and sharpened by fatigue cycling. It is shown that the flawed vessel had similar characteristics to the fracture specimens, thereby allowing estimates to be made of its nearness to failure during a proof test. Both the flawed and unflawed pressure vessel survived the proof pressure and 5 cycles to the working pressure, but it was apparent from the acoustic emission response during the proof cycle and the 5 cycles to the working pressure that the flawed vessel was very near failure. The flawed vessel did not survive a second cycle to the proof pressure before failure due to flaw extension through the wall (causing a leak).

Dunegan, H. L.↗

Polymer-lined filament-wound pressure vessels for nitrogen containment

A program has been started to develop fatigue-resistant polymeric liners for a filament-wound pressure vessel to contain nitrogen gas at room temperature. First, nitrogen permeation of butyl rubber sheet coated with Saran and Parylene C was studied in flat specimens. Then four 10-cm-diam cylindrical pressure vessels were prepared with chlorobutyl rubber liners coated with the same materials. These vessels were valved off after nitrogen gas pressurization to approximately 65% (approximately 11.7 MPa or 1700 psig) of their expected failure pressure. One vessel leaked. The other three vessels showed an average pressure loss of less than 1% per month. These pressure vessels have an average performance factor of approximately 370 kPa-cu m/kg (1,500,000 in.) based on composite mass.

Hamstad, M. A.↗

Polymer-lined filament-wound pressure vessels for nitrogen containment

A program has been started to develop fatigue-resistant polymeric liners for a filament-wound pressure vessel to contain nitrogen gas at room temperature. First, nitrogen permeation of butyl rubber sheet coated with Saran and Parylene C was studied in flat specimens. Then four 10-cm-diam cylindrical pressure vessels were prepared with chlorobutyl rubber liners coated with the same materials. These vessels were valved off after nitrogen gas pressurization to approximately 65% of their expected failure pressure. One vessel leaked. The other three vessels showed an average pressure loss of less than 1% per month. These pressure vessels have an average performance factor of about 370 kPa x cu m/kg based on composite mass.

Hamstad, M. A.↗

Filament-reinforced metal composite pressure vessel evaluation and performance demonstration

Two different Kevlar-49 filament-reinforced metal sphere designs were developed, and six vessels of each type were fabricated and subjected to fatigue cycling, sustained loading, and hydrostatic burst. The 61 cm (24 inch) diameter Kevlar-49/cryoformed 301 stainless steel pressure vessels demonstrated the required pressure cycle capability, burst factor of safety, and a maximum pressure times volume divided by weight (pV/W) performance of 210 J/g (834 000 in-lb/lbm) at burst; this represented a 25 to 30% weight saving over the lightest weight comparable, 6A1-4V Ti, homogeneous pressure vessel. Both the Kevlar/stainless steel design and the 97 cm (38 inch) diameter Kevlar-49/2219-T62 aluminum sphere design demonstrated nonfragmentation and controlled failure mode features when pressure cycled to failure at operating pressure. When failure occurred during pressure cycling, the mode was localized leakage and not catastrophic. Kevlar/stainless steel vessels utilized a unique conical boss design, and Kevlar/aluminum vessels incorporated a tie-rod to carry port loads; both styles of polar fittings performed as designed during operational testing of the vessels.

Landes, R. E.↗

Fatigue performance of metal-lined graphite/epoxy pressure vessels

Using an ultrahigh-strength graphite fiber, a program was started to develop a thin metal-lined fiber/epoxy pressure vessel that would have a fatigue life of over 1000 cycles. First, the performance factor of the fiber/epoxy composite was found to be 351 kN m/kg from the average of 18 rubber-lined pressure vessels. Then, both aluminum- and titanium-lined vessels were filament wound with the graphite fiber in an epoxy matrix. Several of these metal-lined vessels were subjected to hydraulic fatigue testing to about 50% of their expected burst pressures. The average fatigue life of the aluminum-lined vessels was 462 cycles; the average for the titanium-lined vessels was 2190 cycles.

Hamstad, M. A.↗

Fatigue life of organic fiber/epoxy pressure vessels

The cyclic fatigue life of 10.2-cm-diam cylindrical pressure vessels has been studied. The vessels were made of an organic fiber/epoxy composite. To determine the typical strength distribution of the vessels, 25 of them were internally pressurized until they burst. Twenty-five vessels were then tested under sinusoidal cycling at 1 Hz between 4% and 91% of the mean burst strength. An additional twenty-five vessels were tested between 4% and 91% with a rectangular pressure pulse at 1/3 Hz. A limited number of vessels were tested for stress rupture at the 91% level. Cyclic life was found to depend on time at peak load as well as the number of stress cycles.

Hamstad, M. A.↗

Simply actuated closure for a pressure vessel - Design for use to trap deep-sea animals

A pressure vessel is described that can be closed by a single translational motion within 1 sec. The vessel is a key component of a trap for small marine animals and operates automatically on the sea floor. As the vessel descends to the sea floor, it is subjected both internally and externally to the high pressures of the deep sea. The mechanism for closing the pressure vessel on the sea floor is activated by the timed release of the ballast which was used to sink the trap. As it rises to the sea surface, the internal pressure of the vessel remains near the value present on the sea floor. The pressure vessel has been used in simulated ocean deployments and in the deep ocean (9500 m) with a 75%-85% retention of the deep-sea pressure. Nearly 100% retention of pressure can be achieved by using an accumulator filled with a gas.

Yayanos, A. A.↗