Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Vertical Profiles of Mars 1.27 Micrometer O2 Dayglow from MRO CRISM Limb Spectra: Seasonal/global Behaviors, Comparisons to LMDGCM Simulations, and a Global Definition for Mars Water Vapor Profiles

Since July of 2009, The Compact Reconnaissance Imaging Spectral Mapper (CRISM) onboard the Mars Re- connaissance Orbiter (MRO) has periodically obtained pole-to-pole observations (i.e., full MRO orbits) of limb scanned visible/near IR spectra (lambda= 0.4 - 4.0 micrometers, delta lambda approx. 10 nm- Murchie et al., 2007). These CRISM limb observations support the first seasonally and spatially extensive set of Mars 1.27 micometers O2 (1 delta(sub g)) day-glow profile retrievals (approx. 1100) over greater than or equal to 8-80 km altitudes. Their comparison to Laboratoire de Meteorologie Dynamique (LMD) global climate model (GCM) simulated O2 (1 delta(sub g)) volume emission rate (VER) profiles, as a function of altitude, latitude, and season (solar longitude, L(sub s), supports several key conclusions regarding Mars atmospheric water vapor (which is derived from O2 (1 delta(sub g)) emission rates), Mars O3, and the collisional de-excitation of O2 (1 delta(sub g)) in the Mars CO2 atmosphere. Current (Navarro et al., 2014) LMDGCM simulations of Mars atmospheric water vapor fall 2-3 times below CRISM derived water vapor abundances at 20-40 km altitudes over low-to-mid latitudes in northern spring (L(sub s) = 30-60 deg), and northern mid-to-high latitudes over northern summer (L(sub s) = 60-140 deg). In contrast, LMDGCM simulated water vapor is 2-5 times greater than CRISM derived values at all latitudes and seasons above 40 km, within the aphelion cloud belt (ACB), and over high-southern to mid-southern latitudes in southern summer (L(sub s) = 190-340 deg) at 15-35 km altitudes. Overall, the solstitial summer-to-winter hemisphere gradients in water vapor are reversed between the LMDGCM modeled versus the CRISM derived water vapor abundances above 10-30 km altitudes. LMDGCM-CRISM differences in water vapor profiles correlate with LMDGCM-CRISM differences in cloud mixing profiles; and likely reflect limitations in simulating cloud microphysics and radiative forcing, both of which restrict meridional transport of water from summer- to-winter hemispheres on Mars (Clancy et al., 1996; Montmessin et al., 2004; Steele et al., 2014; Navarro et al., 2014) and depend on uncertain cloud microphysical properties (Navarro et al., 2014). The derived low-to-mid latitude changes in Mars water vapor vertical distributions should reduce current model- data disagreements in column O3 and H2O2 abundances over low-to-mid latitudes (e.g., within the ACB; Lefevre et al., 2008; Encrenaz et al., 2015; Clancy et al., 2016). Lastly, the global/seasonal average com- parison of CRISM and LMDGCM O2 (1 delta(sub g)) VER below 20 km altitudes indicates a factor of approx. 3 times lower value (0.25 x 10(exp -20) cu cm sec(exp -1)) for the CO2 collisional de-excitation rate coefficient of O2 (1 delta(sub g)) than derived recently by Guslyakova et al. (2016).

Clancy, R. Todd↗

GEOS Constituent Data Assimilation Beyond Aura MLS: Assimilating NASA SAGE III/ISS Profiles of Stratospheric Water Vapor and Ozone

Ozone and water vapor in the lower stratosphere are important trace gases for atmospheric chemistry and radiative budget. The Stratospheric Aerosol and Gas Experiment (SAGE) missions have been crucial in monitoring the stratospheric ozone loss and the subsequent recovery as well as the trends in water vapor linked to surface temperature trends. The SAGE III instrument aboard the International Space Station (ISS) continues the SAGE mission record, with high vertical resolution profiles of ozone and water vapor available since mid 2017. The NASA GEOS Earth system model has the new capability to assimilate multi-constituents from ground and space-based instruments using the GEOS Constituent Data Assimilation System (CoDAS). The recently released MERRA-2 Stratospheric Composition Reanalysis with Aura MLS (M2-SCREAM) assimilates version 4.2 MLS ozone, water vapor and other chemically-reactive species with the NASA GEOS model coupled to a stratospheric-only chemistry mechanism and transport constrained to the MERRA-2 reanalysis. While the number of solar occultation observations a day from SAGE III/ISS is about 1% of the total number of profiles observed globally by MLS, the chemical timescales of ozone and water vapor in the lower stratosphere are long enough that the SAGE III/ISS data may provide a useful constraint on the assimilated product. Using the same GEOS CoDAS configuration as M2-SCREAM, we will present a series of experiments to investigate if ozone and water vapor trends are consistent with the assimilation of SAGE observations with and without Aura retrievals, and to determine if the assimilation of SAGE observations produces a steady product for trend analysis, especially as the end of the Aura mission nears. In our experiments, assimilating only SAGE III/ISS water vapor profiles results in water vapor fields more consistent with experiments that assimilate MLS v5; however, in the polar regions SAGE III/ISS observations are not available and the values are unconstrained. We are encouraged by the positive benefit assimilating the less frequent SAGE III/ISS observations has on stratospheric composition. Sensitivity experiments such as these will allow us to assess the added value of SAGE data for continued monitoring of the stratospheric composition for climate and ozone recovery assessments.

SAGE↗

GEOS Constituent Data Assimilation Beyond Aura MLS: Assimilating NASA SAGE III/ISS Profiles of Stratospheric Water Vapor

Ozone and water vapor in the lower stratosphere are important trace gases for atmospheric chemistry and radiative budget. The Stratospheric Aerosol and Gas Experiment (SAGE) missions have been crucial in monitoring the stratospheric ozone loss and the subsequent recovery as well as the trends in water vapor linked to surface temperature trends. The SAGE III instrument aboard the International Space Station (ISS) continues the SAGE mission record, with high vertical resolution profiles of ozone and water vapor available since mid 2017. The NASA GEOS Earth system model has the new capability to assimilate multi-constituents from ground and space-based instruments using the GEOS Constituent Data Assimilation System (CoDAS). The recently released MERRA-2 Stratospheric Composition Reanalysis with Aura MLS (M2-SCREAM) assimilates version 4.2 MLS ozone, water vapor and other chemically-reactive species with the NASA GEOS model coupled to a stratospheric-only chemistry mechanism and transport constrained to the MERRA-2 reanalysis. While the number of solar occultation observations a day from SAGE III/ISS is about 1% of the total number of profiles observed globally by MLS, the chemical timescales of ozone and water vapor in the lower stratosphere are long enough that the SAGE III/ISS data may provide a useful constraint on the assimilated product. Using the same GEOS CoDAS configuration as M2-SCREAM, we will present a series of experiments to investigate if water vapor trends are consistent with the assimilation of SAGE observations with and without Aura retrievals, and to determine if the assimilation of SAGE observations produces a steady product for trend analysis, especially as the end of the Aura mission nears. In our experiments, assimilating only SAGE III/ISS water vapor profiles results in water vapor fields more consistent with experiments that assimilate MLS v5; however, in the polar regions SAGE III/ISS observations are not available and the modelled values are unconstrained. We are encouraged by the positive benefit assimilating the less frequent SAGE III/ISS observations has on stratospheric composition. Sensitivity experiments such as these will allow us to assess the added value of SAGE data for continued monitoring of the stratospheric composition for climate and ozone recovery assessments.

K Emma Knowland↗

Correction Technique for Raman Water Vapor Lidar Signal-Dependent Bias and Suitability for Water Wapor Trend Monitoring in the Upper Troposphere

The MOHAVE-2009 campaign brought together diverse instrumentation for measuring atmospheric water vapor. We report on the participation of the ALVICE (Atmospheric Laboratory for Validation, Interagency Collaboration and Education) mobile laboratory in the MOHAVE-2009 campaign. In appendices we also report on the performance of the corrected Vaisala RS92 radiosonde measurements during the campaign, on a new radiosonde based calibration algorithm that reduces the influence of atmospheric variability on the derived calibration constant, and on other results of the ALVICE deployment. The MOHAVE-2009 campaign permitted the Raman lidar systems participating to discover and address measurement biases in the upper troposphere and lower stratosphere. The ALVICE lidar system was found to possess a wet bias which was attributed to fluorescence of insect material that was deposited on the telescope early in the mission. Other sources of wet biases are discussed and data from other Raman lidar systems are investigated, revealing that wet biases in upper tropospheric (UT) and lower stratospheric (LS) water vapor measurements appear to be quite common in Raman lidar systems. Lower stratospheric climatology of water vapor is investigated both as a means to check for the existence of these wet biases in Raman lidar data and as a source of correction for the bias. A correction technique is derived and applied to the ALVICE lidar water vapor profiles. Good agreement is found between corrected ALVICE lidar measurments and those of RS92, frost point hygrometer and total column water. The correction is offered as a general method to both quality control Raman water vapor lidar data and to correct those data that have signal-dependent bias. The influence of the correction is shown to be small at regions in the upper troposphere where recent work indicates detection of trends in atmospheric water vapor may be most robust. The correction shown here holds promise for permitting useful upper tropospheric water vapor profiles to be consistently measured by Raman lidar within NDACC (Network for the Detection of Atmospheric Composition Change) and elsewhere, despite the prevalence of instrumental and atmospheric effects that can contaminate the very low signal to noise measurements in the UT.

MOHAVE-2009↗

Redefining fuel heating value for engines: Accounting for heat of vaporization

Defining a fuel's heating value (i.e., energy content) is fundamental for calculating engine efficiency and for life cycle analysis comparisons between different fuels. Traditional definitions of lower heating value and higher heating value account for the effect of water vapor versus liquid water in the exhaust, which is important when the fuel is used in a furnace or boiler. In an engine, it is equally important to properly account for the energy required to vaporize liquid fuel. Heat of vaporization has a small effect for common hydrocarbon fuels, typically less than 1% of lower heating value, but the effect is much larger for other important fuels such as ethanol (3.4% of lower heating value) and methanol (5.9% of lower heating value). This paper defines a new type of fuel heating value that more accurately reflects the useful fuel energy content for engines. Vaporized heating value is defined as the heating value when starting with a vaporized fuel instead of a liquid fuel. It can be calculated by adding the fuel's heat of vaporization to the traditional lower heating value. This paper illustrates the rationale and benefits of using vaporized heating value using data from the literature.

09 BIOMASS FUELS↗

Variability of Water Vapor in the Tropical Middle Atmosphere Observed From Satellites and Interpreted Using SD-WACCM Simulations

Water vapor in the middle atmosphere plays an essential role in global warming, ozone depletion, and the formation of polar stratospheric and mesospheric clouds. We show that tropical middle atmospheric water vapor simulated with the specified-dynamics version of the Whole Atmosphere Community Climate Model (SD-WACCM) is consistent with changes observed in a merged satellite data set, which encompasses the period 1993–2020. Consistent with previous work, we find no significant trend in the stratosphere in either the observations or the simulation; in the mesosphere, we find a long-term trend of 0.1 ppmv per decade, but only in the observations. We also analyze an SD-WACCM simulation for the longer period 1980–2019 to quantify the contribution of various factors to the decadal variation of middle atmospheric water vapor. Over 1980–1995, the simulated water vapor in the upper stratosphere and mesosphere, averaged zonally and over ±30° latitude, increases by 0.30 ppmv per decade due to increasing methane emissions. After 1995, a significant abrupt decrease of water vapor of 0.37 ppmv per decade and then a gradual increase of 0.33 ppmv per decade result from changes in stratospheric cold point temperature. The cold-point temperature is strongly influenced by the strength of the Brewer-Dobson circulation. The acceleration of the Brewer-Dobson circulation before about 2003 leads to a cooler tropical tropopause and a decrease of water vapor, and the deceleration thereafter leads to corresponding warming of the tropopause and an increase in water vapor.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Marine Boundary Layer Decoupling and the Stable Isotopic Composition of Water Vapor

Decoupling of the subcloud layer in stratocumulus-topped marine boundary layers (STMBL) influences low-cloud cover by limiting the supply of water vapor from the surface. However, the relative importance of mixing between surface fluxes and other reservoirs of water vapor as a function of the degree of decoupling is poorly understood. Water vapor transport within the STMBL and its response to decoupling is explored using surface measurements of water vapor isotopic composition that were obtained from Graciosa Island, Azores, during the summer and fall of 2018. The data show an inverse relationship between the decoupling metric, Δq, and the degree of drying from an isotopically depleted water vapor source. The isotopic data require some degree of drying with an isotopically depleted source for coupled conditions, and likely require a small amount of mixing even for strongly decoupled conditions. The data are consistent with mixing between purely local reservoirs of water vapor, subjected to a small amount of condensation and fractionation, and do not require the invocation of large-scale transport of water vapor aloft or additional cloud-formation effects aloft.

54 ENVIRONMENTAL SCIENCES↗

Cloud response to co-condensation of water and organic vapors over the boreal forest

Abstract. Accounting for the condensation of organic vapors along with water vapor (co-condensation) has been shown in adiabatic cloud parcel model (CPM) simulations to enhance the number of aerosol particles that activate to form cloud droplets. The boreal forest is an important source of biogenic organic vapors, but the role of these vapors in co-condensation has not been systematically investigated. In this work, the environmental conditions under which strong co-condensation-driven cloud droplet number enhancements would be expected over the boreal biome are identified. Recent measurement technology, specifically the Filter Inlet for Gases and AEROsols (FIGAERO) coupled to an iodide-adduct chemical ionization mass spectrometer (I-CIMS), is utilized to construct volatility distributions of the boreal atmospheric organics. Then, a suite of CPM simulations initialized with a comprehensive set of concurrent aerosol observations collected in the boreal forest of Finland during spring 2014 is performed. The degree to which co-condensation impacts droplet formation in the model is shown to be dependent on the initialization of temperature, relative humidity, updraft velocity, aerosol size distribution, organic vapor concentration, and the volatility distribution. The predicted median enhancements in cloud droplet number concentration (CDNC) due to accounting for the co-condensation of water and organics fall on average between 16 % and 22 %. This corresponds to activating particles 10–16 nm smaller in dry diameter that would otherwise remain as interstitial aerosol. The highest CDNC enhancements (ΔCDNC) are predicted in the presence of a nascent ultrafine aerosol mode with a geometric mean diameter of ∼ 40 nm and no clear Hoppel minimum, indicative of pristine environments with a source of ultrafine particles (e.g., via new particle formation processes). Such aerosol size distributions are observed 30 %–40 % of the time in the studied boreal forest environment in spring and fall when new particle formation frequency is the highest. To evaluate the frequencies with which such distributions are experienced by an Earth system model over the whole boreal biome, 5 years of UK Earth System Model (UKESM1) simulations are further used. The frequencies are substantially lower than those observed at the boreal forest measurement site (< 6 % of the time), and the positive values, peaking in spring, are modeled only over Fennoscandia and the western parts of Siberia. Overall, the similarities in the size distributions between observed and modeled (UKESM1) are limited, which would limit the ability of this model, or any model with a similar aerosol representation, to project the climate relevance of co-condensation over the boreal forest. For the critical aerosol size distribution regime, ΔCDNC is shown to be sensitive to the concentrations of semi-volatile and some intermediate-volatility organic compounds (SVOCs and IVOCs), especially when the overall particle surface area is low. The magnitudes of ΔCDNC remain less affected by the more volatile vapors such as formic acid and extremely low- and low-volatility organic compounds (ELVOCs and LVOCs). The reasons for this are that most volatile organic vapors condense inefficiently due to their high volatility below the cloud base, and the concentrations of LVOCs and ELVOCs are too low to gain significant concentrations of soluble mass to reduce the critical supersaturations enough for droplet activation to occur. A reduction in the critical supersaturation caused by organic condensation emerges as the main driver of the modeled ΔCDNC. The results highlight the potential significance of co-condensation in pristine boreal environments close to sources of fresh ultrafine particles. For accurate predictions of co-condensation effects on CDNC, also in larger-scale models, an accurate representation of the aerosol size distribution is critical. Further studies targeted at finding observational evidence and constraints for co-condensation in the field are encouraged.

54 ENVIRONMENTAL SCIENCES↗

Heat transfer by condensation of low pressure metal vapors.

The film condensation of low pressure metal vapors on isothermal vertical flat plates or tubes is considered. The liquid film is treated as a thin layer in which the acceleration and pressure forces are negligible and across which the temperature distribution is linear. The average behavior of the vapor is found from the linearized one-dimensional vapor flow equations. In order to calculate the rate of condensation, a consistent distribution function for the vapor particles at the liquid-vapor interface is necessary and is determined. The result of the analysis is a set of algebraic equations from which one can predict the condensation rate of low pressure metal vapors. A large but continuous temperature decrease in the vapor is predicted and calculated.

Huang, Y. S.↗

A method for estimation of atmospheric water vapor profiles by microwave radiometry

Simultaneous measurements of microwave emission from the earth, in the oxygen band near 60 GHz, and the water vapor line near 183 GHz are conducted to determine the atmospheric temperature as a function of the pressure and the water vapor burden, and a combination of these two profiles yields a profile of water vapor burden versus pressure. Numerical simulations are developed by using temperature and water vapor profiles from subtropical and midlatitude radiosonde stations, and by assuming surface reflectivities typical of either land or ocean. Over a land surface, the residual rms errors in the estimated water vapor burden profile between 300 and 1000 mb are determined to range from 23 to 43% of the a priori standard deviation of water vapor burden for the corresponding climate. The relative humidity profile is also estimated and found to contain rms errors ranging from 4 to 17% of saturation. Over a seawater surface, using three additional channels of 18.5, 22.2, and 31.7 GHz, the corresponding results are found to be 3-46% of the a priori standard deviation for water vapor burden and 4-15% rms error for relative humidity.

Rosenkranz, P. W.↗

Criteria for significance of simultaneous presence of both condensible vapors and aerosol particles on mass transfer (deposition) rates

The simultaneous presence of aerosol particles and condensible vapors in a saturated boundary layer which may affect deposition rates to subcooled surfaces because of vapor-particle interactions is discussed. Scavenging of condensible vapors by aerosol particles may lead to increased particle size and decreased vapor mass fraction, which alters both vapor and particle deposition rates. Particles, if sufficiently concentrated, may also coagulate. Criteria are provided to assess the significance of such phenomena when particles are already present in the mainstream and are not created inside the boundary layer via homogeneous nucleation. It is determined that there is direct proportionality with: (1) the mass concentration of both condensible vapors and aerosol particles; and (2) the square of the boundary layer thickness to particle diameter ratio (delta d sub p) square. Inverse proportionality was found for mainstream to surface temperature difference if thermophoresis dominates particle transport. It is concluded that the square of the boundary layer thickness to particle diameter ratio is the most critical factor to consider in deciding when to neglect vapor-particle interactions.

Gokoglu, S. A.↗

CO2 DIAL measurements of water vapor

CO2 lidars have heretofore been used to measure water vapor concentrations primarily using the 10R(20) line at 10.247 microns, which has a strong overlap with a water vapor absorption line. This paper discusses the use of that line as well as other CO2 laser lines for which the absorption coefficients are weaker. The literature on measurement of water vapor absorption coefficients using CO2 lasers is reviewed, and the results from four laboratories are shown to be generally consistent with each other after they are normalized to the same partial pressure, temperature, and ethylene absorption coefficent for the 10P(14) CO2 laser line; however, the agreement with the Air Force Geophysics Laboratory's HITRAN and FASCOD 2 spectral data tapes is not good either for the water vapor absorption lines or for the water vapor continuum. Demonstration measurements of atmospheric water vapor have been conducted using the Mobile Atmospheric Pollutant Mapping System, a dual CO2 lidar system using heterodyne detection. Results are discussed for measurements using three sets of laser line pairs covering a wide range of water vapor partial pressures.

Grant, William B.↗

Criteria for significance of simultaneous presence of both condensible vapors and aerosol particles on mass transfer (deposition) rates

The simultaneous presence of aerosol particles and condensible vapors in a saturated boundary layer which may affect deposition rates to subcooled surfaces because of vapor-particle interactions is discussed. Scavenging of condensible vapors by aerosol particles may lead to increased particle size and decreased vapor mass fraction, which alters both vapor and particle deposition rates. Particles, if sufficiently concentrated, may also coagulate. Criteria are provided to assess the significance of such phenomena when particles are already present in the mainstream and are not created inside the boundary layer via homogeneous nucleation. It is determined that there is direct proportionality with: (1) the mass concentration of both condensible vapors and aerosol particles; and (2) the square of the boundary layer thickness to particle diameter ratio (delta d sub p) square. Inverse proportionality was found for mainstream to surface temperature difference if thermophoresis dominates particle transport. It is concluded that the square of the boundary layer thickness to particle diameter ratio is the most critical factor to consider in deciding when to neglect vapor-particle interactions.

Gokoglu, S. A.↗

Vapor crystal growth technology development: Application to cadmium telluride

Growth of bulk crystals by physical vapor transport was developed and applied to cadmium telluride. The technology makes use of effusive ampoules, in which part of the vapor contents escapes to a vacuum shroud through defined leaks during the growth process. This approach has the advantage over traditional sealed ampoule techniques that impurity vapors and excess vapor constituents are continuously removed from the vicinity of the growing crystal. Thus, growth rates are obtained routinely at magnitudes that are rather difficult to achieve in closed ampoules. Other advantages of this effusive ampoule physical vapor transport (EAPVT) technique include the predetermination of transport rates based on simple fluid dynamics and engineering considerations, and the growth of the crystal from close to congruent vapors, which largely alleviates the compositional nonuniformities resulting from buoyancy driven convective transport. After concisely reviewing earlier work on improving transport rates, nucleation control, and minimization of crystal wall interactions in vapor crystal growth, a detail account is given of the largely computer controlled EAPVT experimentation.

Rosenberger, Franz↗

Preliminary characterizations of a water vaporizer for resistojet applications

A series of tests were conducted to explore the characteristics of a water vaporizer intended for application to resistojet propulsion systems. A laboratory model of a forced-flow, once-through water vaporizer employing a porous heat exchange medium was built and characterized over a range of flow rates and power levels of interest for application to water resistojets. In a test during which the vaporizer was rotated about a horizontal axis normal to its own axis, the outlet temperature and mass flow rate through the vaporizer remained steady. Throttlability to 30 percent of the maximum flow rate tested was demonstrated. The measured thermal efficiency of the vaporizer was near 0.9 for all tests. The water vaporizer was integrated with an engineering model multipropellant resistojet. Performance of the vaporizer/thruster assembly was measured over a narrow range of operating conditions. The maximum specific impulse measured was 234 s at a mass flow rate and specific power level (vaporizer and thruster combined) of 154 x 10 exp -6 kg/s and 6.8 MJ/kg, respectively.

Morren, W. E.↗

Numerical modeling of physical vapor transport under microgravity conditions: Effect of thermal creep and stress

One of the most promising applications of microgravity (micro-g) environments is the manufacture of exotic and high-quality crystals in closed cylindrical ampoules using physical vapor transport (PVT) processes. The quality enhancements are believed to be due to the absence of buoyant convection in the weightless environment - resulting in diffusion-limited transport of the vapor. In a typical experiment, solid-phase sample material is initially contained at one end of the ampoule. The sample is made to sublime into the vapor phase and deposit onto the opposite end by maintaining the source at an elevated temperature with respect to the deposit. Identification of the physical factors governing both the rates and uniformity of crystal growth, and the optimization of the micro-g technology, will require an accurate modeling of the vapor transport within the ampoule. Previous micro-g modeling efforts have approached the problem from a 'classical' convective/diffusion formulation, in which convection is driven by the action of buoyancy on thermal and solutal density differences. The general conclusion of these works have been that in low gravity environments the effect of buoyancy on vapor transport is negligible, and vapor transport occurs in a diffusion-limited mode. However, it has been recently recognized than in the non-isothermal (and often low total pressure) conditions encountered in ampoules, the commonly-assumed no-slip boundary condition to the differential equations governing fluid motion can be grossly unrepresentative of the actual situation. Specifically, the temperature gradients can give rise to thermal creep flows at the ampoule side walls. In addition, temperature gradients in the vapor itself can, through the action of thermal stress, lead to bulk fluid convection.

Mackowski, Daniel W.↗

Production of long-term global water vapor and liquid water data set using ultra-fast methods to assimilate multi-satellite and radiosonde observations

During the next decade, many programs and experiments under the Global Energy and Water Cycle Experiment (GEWEX) will utilize present day and future data sets to improve our understanding of the role of moisture in climate, and its interaction with other variables such as clouds and radiation. An important element of GEWEX will be the GEWEX Water Vapor Project (GVaP), which will eventually initiate a routine, real-time assimilation of the highest quality, global water vapor data sets including information gained from future data collection systems, both ground and space based. The comprehensive global water vapor data set being produced by METSAT Inc. uses a combination of ground-based radiosonde data, and infrared and microwave satellite retrievals. This data is needed to provide the desired foundation from which future GEWEX-related research, such as GVaP, can build. The first year of this project was designed to use a combination of the best available atmospheric moisture data including: radiosonde (balloon/acft/rocket), HIRS/MSU (TOVS) retrievals, and SSM/I retrievals, to produce a one-year, global, high resolution data set of integrated column water vapor (precipitable water) with a horizontal resolution of 1 degree, and a temporal resolution of one day. The time period of this pilot product was to be det3ermined by the availability of all the input data sets. January 1988 through December 1988 were selected. In addition, a sample of vertically integrated liquid water content (LWC) was to be produced with the same temporal and spatial parameters. This sample was to be produced over ocean areas only. Three main steps are followed to produce a merged water vapor and liquid water product. Input data from Radiosondes, TOVS, and SSMI/I is quality checked in steps one and two. Processing is done in step two to generate individual total column water vapor and liquid water data sets. The third step, and final processing task, involves merging the individual output products to produce the integrated water vapor product. A final quality control is applied to the merged data sets.

Vonderhaar, T. H.↗