Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Diffusion‐Based Uncertainty Quantification Method to Advance E3SM Land Model Calibration

Abstract Calibrating land surface models and accurately quantifying their uncertainty are crucial for improving the reliability of simulations of complex environmental processes. This, in turn, advances our predictive understanding of ecosystems and supports climate‐resilient decision‐making. Traditional calibration methods, however, face challenges of high computational costs and difficulties in accurately quantifying parameter uncertainties. To address these issues, we develop a diffusion‐based uncertainty quantification (DBUQ) method. Unlike conventional generative diffusion methods, which are computationally expensive and memory‐intensive, DBUQ innovates by formulating a parameterized generative model and approximates this model through supervised learning, which enables quick generation of parameter posterior samples to quantify its uncertainty. DBUQ is effective, efficient, and general‐purpose, making it suitable for site‐specific ecosystem model calibration and broadly applicable for parameter uncertainty quantification across various earth system models. In this study, we applied DBUQ to calibrate the Energy Exascale Earth System Model land model at the Missouri Ozark AmeriFlux forest site. Results indicated that DBUQ produced accurate parameter posterior distributions similar to those from Markov Chain Monte Carlo sampling but with 30 times less computing time. This significant improvement in efficiency suggests that DBUQ can enable rapid, site‐level model calibration at a global scale, enhancing our predictive understanding of climate impacts on terrestrial ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Precision calibration of calorimeter signals in the ATLAS experiment using an uncertainty-aware neural network

The ATLAS experiment at the Large Hadron Collider explores the use of modern neural networks for a multi-dimensional calibration of its calorimeter signal defined by clusters of topologically connected cells (topo-clusters). The Bayesian neural network (BNN) approach not only yields a continuous and smooth calibration function that improves performance relative to the standard calibration but also provides uncertainties on the calibrated energies for each topo-cluster. The results obtained by using a trained BNN are compared to the standard local hadronic calibration and to a calibration provided by training a deep neural network. The uncertainties predicted by the BNN are interpreted in the context of a fractional contribution to the systematic uncertainties of the trained calibration. They are also compared to uncertainty predictions obtained from an alternative estimator employing repulsive ensembles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below ∼3 keV nr where signals from dark matter particles of <10 GeV/c 2 masses are expected. The coherent elastic neutrino-nucleus scattering (CE ν NS) by solar 8 B neutrinos also results in a continuum of nuclear recoil events below 3.0 keV nr (99% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on 8 B searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor ∼2 for a 6 GeV WIMP mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar 8 B flux measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental methods for laboratory measurements of helium spectral line broadening in white dwarf photospheres

White Dwarf (WD) stars are the most common stellar remnant in the universe. WDs usually have a hydrogen or helium atmosphere, and helium WD (called DB) spectra can be used to solve outstanding problems in stellar and galactic evolution. DB origins, which are still a mystery, must be known to solve these problems. DB masses are crucial for discriminating between different proposed DB evolutionary hypotheses. Current DB mass determination methods deliver conflicting results. The spectroscopic mass determination method relies on line broadening models that have not been validated at DB atmosphere conditions. We performed helium benchmark experiments using the White Dwarf Photosphere Experiment (WDPE) platform at Sandia National Laboratories' Z-machine that aims to study He line broadening at DB conditions. Using hydrogen/helium mixture plasmas allows investigating the importance of He Stark and van der Waals broadening simultaneously. Accurate experimental data reduction methods are essential to test these line-broadening theories. In this paper, we present data calibration methods for these benchmark He line shape experiments. We give a detailed account of data processing, spectral power calibrations, and instrument broadening measurements. Uncertainties for each data calibration step are also derived. We demonstrate that our experiments meet all benchmark experiment accuracy requirements: WDPE wavelength uncertainties are <1 Å, spectral powers can be determined to within 15%, densities are accurate at the 20% level, and instrumental broadening can be measured with 20% accuracy. Fulfilling these stringent requirements enables WDPE experimental data to provide physically meaningful conclusions about line broadening at DB conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Quantification for a Multi-phase Carbon Equation of State Model

Many physics models have tunable parameters that are calibrated by matching the model output to experimental or calculated data. However, given that calibration data often contain uncertainty and that different model parameter sets might result in a very similar simulated output for a finite calibration data set, it is advantageous to provide an ensemble of parameter sets that are consistent with the calibration data. Uncertainty quantification (UQ) provides a means to generate such an ensemble in a statistically rigorous fashion. In this work, we perform UQ for a multi-phase equation of state (EOS) model for carbon containing the diamond, graphite, and liquid phases. We use a Bayesian framework for the UQ and introduce a novel strategy for including phase diagram information in the calibration. The method is highly general and accurately reproduces the calibration data without any material-specific prior knowledge of the EOS model parameters.

36 MATERIALS SCIENCE↗

Training calibration-based counterfactual explainers for deep learning models in medical image analysis

The rapid adoption of artificial intelligence methods in healthcare is coupled with the critical need for techniques to rigorously introspect models and thereby ensure that they behave reliably. This has led to the design of explainable AI techniques that uncover the relationships between discernible data signatures and model predictions. In this context, counterfactual explanations that synthesize small, interpretable changes to a given query while producing desired changes in model predictions have become popular. This under-constrained, inverse problem is vulnerable to introducing irrelevant feature manipulations, particularly when the model’s predictions are not well-calibrated. Hence, in this paper, we propose the TraCE (training calibration-based explainers) technique, which utilizes a novel uncertainty-based interval calibration strategy for reliably synthesizing counterfactuals. Given the wide-spread adoption of machine-learned solutions in radiology, our study focuses on deep models used for identifying anomalies in chest X-ray images. Using rigorous empirical studies, we demonstrate the superiority of TraCE explanations over several state-of-the-art baseline approaches, in terms of several widely adopted evaluation metrics. Our findings show that TraCE can be used to obtain a holistic understanding of deep models by enabling progressive exploration of decision boundaries, to detect shortcuts, and to infer relationships between patient attributes and disease severity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity of an integrated experiment to uncertainty in the high explosive equations of state

Traditionally, hydrodynamics simulations are performed with a single equation-of-state (EOS) to describe each material. These EOSs typically have a physics-informed functional form with adjustable parameters that are calibrated in order to replicate small-scale data. However, because the calibration data have uncertainty and there are typically inherent degeneracies in fitting the EOS, there are actually multiple EOSs that might be consistent with calibration data. In this work, we perform uncertainty quantification (UQ) for the reactant and product equations of state for the high explosive PBX 9501 to yield an ensemble of EOSs that match the uncertain small-scale calibration data. We then simulate an experiment of an explosively formed penetrator repeatedly with different EOSs to both validate the UQ analysis and determine the effects of EOS uncertainty on the prediction of quantities of interest in the experiment. In general, we find good agreement between the simulation predictions and the experimental measurements, and we identify an EOS variable that contributes most directly to the spread in the predictions as the EOSs are varied.

36 MATERIALS SCIENCE↗

2D Simulations of Diamagnetic Loop Calibrations

Diamagnetic loops can be used as a non-invasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. A comprehensive theory for interpreting data from a diamagnetic loop relates the rms beam radius to the excluded flux measured by the loop and the beam current. Thus, primary calibration of the loop must relate the loop signal directly to the exclude d flux. We have simulated these calibrations with a 2D field solver in order to identify possible sources of uncertainty in our calibration technique.

43 PARTICLE ACCELERATORS↗

Evaluating the Effects of Detector Modeling Uncertainties on Sterile Neutrino Oscillation Analysis with the ICARUS Detector

he ICARUS T600 LArTPC detector was refurbished after an initial run at the underground LNGS labs and is currently taking data within its experimental hall at Fermilab after full commissioning. Regular data taking began in May 2021 with neutrinos from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) off-axis beam. As the far detector of the Short-Baseline Neutrino (SBN) Program, the ICARUS detector's capability in searching for both muon neutrino disappearance and electron neutrino appearance will allow for unprecedented sensitivity to light sterile neutrinos with eV-scale mass. The ultimate sensitivity of the detector to sterile neutrino oscillations depends on the understanding of the detector response and the uncertainties remaining after calibrating the detector model. This poster will review how detector-model-related uncertainties are quantified, evaluated and their impact on expected sterile neutrino oscillation sensitivities using the existing ICARUS data. The work pursued here is broadly applicable to other ICARUS analysis pathways such as neutrino-argon cross-sections and Beyond the Standard Model physics searches. It will finally discuss improvement pathways to reduce the systematic uncertainties to the level needed for the joint sterile neutrino oscillation analysis with the Short Baseline Near Detector (SBND) within the SBN Program.

43 PARTICLE ACCELERATORS↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Computer Model Calibration with Time Series Data Using Deep Learning and Quantile Regression

Computer models play a key role in many scientific and engineering problems. One major source of uncertainty in computer model experiments is input parameter uncertainty. Computer model calibration is a formal statistical procedure to infer input parameters by combining information from model runs and observational data. The existing standard calibration framework suffers from inferential issues when the model output and observational data are high-dimensional dependent data, such as large time series, due to the difficulty in building an emulator and the nonidentifiability between effects from input parameters and data-model discrepancy. To overcome these challenges, we, in this work, propose a new calibration framework based on a deep neural network (DNN) with long short-term memory layers that directly emulates the inverse relationship between the model output and input parameters. Adopting the “learning with noise” idea, we train our DNN model to filter out the effects from data-model discrepancy on input parameter inference. We also formulate a new way to construct interval predictions for DNN using quantile regression to quantify the uncertainty in input parameter estimates. Through a simulation study and real data application with the Weather Research and Forecasting Model Hydrological modeling system (WRF-Hydro), we show our approach can yield accurate point estimates and well-calibrated interval estimates for input parameters.

97 MATHEMATICS AND COMPUTING↗

Parameter Calibration for Johnson Cook and Preston-Tonks-Wallace Material Strength Models with Uncertainty Quantification

In this study we perform a Bayesian calibration of the parameters in the Johnson Cook (JC) material strength model, with uncertainty, using experiments with for a range of low and medium strain rates. For the parameter calibration, we used a variational Bayesian approach with experimental data from Hopkinson bar and quasi-static tests done on Oxygen Free High Conductivity (OFHC) copper. The estimated parameter values matched well with experimental data for a modest range of strain rates and temperatures. Through this method, we also recovered uncertainty and correlation information for the estimated parameter values. We also compared our results to a calibration of parameters in the Preston-Tonks-Wallace (PTW) material strength model, using the same variational Bayesian method. The parameters estimated for both models provided good agreement with the experimental data.

36 MATERIALS SCIENCE↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

Source Characterization at Low Yields from Physics Experiment One A

The detonation of a well-recorded coupled explosion at the well-characterized Nevada National Security Site, as part of Physics Experiment One, has provided us with an opportunity to compare and contrast methods and results of yield estimation and other event characterization methods. Yield estimates are made using several methods, including local/regional magnitudes, waveform envelopes, acoustic amplitudes, joint seismoacoustic yield, and moment tensors. We include in our analysis a discussion and comparison of applicability, calibrations, assumptions, and uncertainties involved in each. With the exception of magnitude-based methods, all the techniques were more or less successful in recovering the known yield. It is, however, useful to be cognizant of requirements and calibrations, such as station coverage, emplacement conditions, propagation characterization, and uncertainties, to apply the methods to other areas with less complete information. We demonstrate that we can be successful at monitoring low-yield explosions using a variety of methods assuming that the signal-to-noise ratio is adequate at recording stations, and that the material properties are taken into account. Depth estimates are also important, particularly if one allows the possibility of a surface explosion.

Pasyanos, Michael E. [Lawrence Livermore National ↗

Measurement of Telescope Transmission Using a Collimated Beam Projector

With the increasingly large number of Type Ia supernova being detected by current-generation survey telescopes, and even more expected with the upcoming Rubin Observatory Legacy Survey of Space and Time, the precision of cosmological measurements will become limited by systematic uncertainties in flux calibration rather than statistical noise. One major source of systematic error in determining SNe Ia color evolution (needed for distance estimation) is uncertainty in telescope transmission, both within and between surveys. We introduce here the Collimated Beam Projector (CBP), which is meant to measure a telescope transmission with collimated light. The collimated beam more closely mimics a stellar wave front as compared to flat-field-based instruments, allowing for more precise handling of systematic errors such as those from ghosting and filter angle-of-incidence dependence. As a proof of concept, we present CBP measurements of the StarDICE prototype telescope, achieving a standard (1σ) uncertainty of 3% on average over the full wavelength range measured with a single beam illumination.

79 ASTRONOMY AND ASTROPHYSICS↗

The DESI DR1 Peculiar Velocity Survey: Global Zero-point and H 0 Constraints

The Dark Energy Spectroscopic Instrument (DESI) in its first Data Release (DR1) already provides more than 100,000 galaxies with relative distance measurements. The primary purpose of this paper is to perform the calibration of the zero-point for the DESI Fundamental Plane and Tully–Fisher relations, which allows us to measure the Hubble constant, H 0 . This sample has a lower statistical uncertainty than any previously used to measure H 0 , and we investigate the systematic uncertainties in absolute calibration that could limit the accuracy of that measurement. We improve upon the DESI Early Data Release Fundamental Plane H 0 measurement by (a) using a group catalog to increase the number of calibrator galaxies and (b) investigating alternative calibrators in the nearby Universe. Our baseline measurement calibrates to the SH0ES/Pantheon+ type Ia supernovae, and finds H 0 = 73.7 ± 0.06 (stat.) ± 1.1 (syst.) km s −1 Mpc −1 . Calibrating to surface brightness fluctuation distances yields a similar H 0 . We explore measurements using other calibrators, but these are currently less precise since the overlap with DESI peculiar velocity tracers is much smaller. In future data releases with an even larger peculiar velocity sample, we plan to calibrate directly to Cepheids and the tip of the red giant branch, which will enable the uncertainty to decrease towards a percent-level measurement of H 0 . This will provide an alternative to supernovae as the Hubble flow sample for H 0 measurements.

Carr, Anthony [Korea Astronomy and Space Science I↗