Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “turbine testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of cooling-hole geometry on aerodynamic performance of a film-cooled turbine vane tested with cold air in a two-dimensional cascade

The effect of the orientation and cooling-hole size on turbine-vane aerodynamic losses was evaluated. The contribution of individual vane regions to the overall effect was also investigated. Test configurations were based upon a representative configuration having 45 spanwise rows of holes spaced about the entire vane profile. Nominal hole diameters of 0.0254 and 0.0356 cm and nominal hole orientations of 35 deg, 45 deg, and 55 deg from the local vane surface and 0 deg, 45 deg, and 90 deg from the main-stream flow direction were investigated. Flow conditions and aerodynamic losses were determined by vane-exit surveys of total pressure, static pressure, and flow angle.

Kline, J. F.↗

Carbon Fiber Reinforced/Silicon Carbide Turbine Blisk Testing in the SIMPLEX Turbopump

A program designed to implement a ceramic matrix composite integrally bladed disk (blisk) into rocket engine style turbomachinery has successfully completed testing. The Marshall Space Flight Center (MSFC) program, utilizing the MSFC turbomachinery design, analysis, and testing capabilities along with materials development capabilities from both Glenn Research Center (GRC) and MSFC, has tested two carbon fiber reinforced silicon carbide blisks in the Simplex Turbopump at MSFC's Test Stand 500. One blisk contained a polar woven fiber preform, while the second blisk tested utilized a quasi-isotropic preform. Vhile earlier papers have chronicled the program's design, material testing, and torque testing efforts, this paper focuses on the testing of the blisks in the Simplex turbopump. Emphasis will be placed on the actual condition of the blisks before and after the testing test program design methodology, and conclusions that can be drawn from the test data and blisk final conditions. The program performed three separate test series. The first series was needed to validate that the Simplex turbopump was correctly re-built following a major incident to the turbopump. The turbopump had two major differences from the original design. The most obvious difference was the sleeve required throughout the bore of the main housing. The second major difference was modifications to the pump diffuser to improve performance. Several areas were burnt during the incident and were either repaired by weld repair (pump inlet housing) or simply smoothed out (turbine nozzle discharge). The test series was designed to weed out any turbopump design and manufacturing flaws or fatigue issues prior to putting the C/SiC blisks into it. The second and third series were the C/SiC blisk test series. The primary goal of these series was to expose the blisks to as much fatigue causing dynamic stress as possible to examine the material's capability. Initially, the test plan was to put equal time on the two blisks, however, as the test series progressed, the funding allowed additional testing to occur. The additional test time was placed on the polar weave blisk. The total test time accrued on the polar blisk was 2550 seconds with 860 seconds near the turbopump design speed of 25,000 rpm. This testing included 6 tests / 775 seconds pumping liquid nitrogen and 7 tests / 1775 seconds pumping liquid oxygen. The drive gas for all of the tests was gaseous nitrogen due to the lack of hot gas source for the Simplex turbopump. The quasi-isotropic blisk was tested for XX total tests and XXXX seconds with X tests/XXXX seconds pumping liquid nitrogen and X tests/XXXX seconds pumping liquid \oxygen.During the test series, the blisks were inspected following each test. Inspections initially were viewed from the downstream side of the blisks only. Midway through the testing, a method of borescoping the leading edges of the blades was devised, and subsequently, both sides of the blades were inspected following each test. The leading and trailing edges of the polar blisk held up better than the quasi-isotropic blisk. This was a known possibility due to the varying fiber direction in the blades as the rectangular preform weave is cut in a circular pattern. The surprising fact about the testing was that there was no measurable performance loss due to the inaccuracies in the blade manufacturing in the C/SiC blisks, the surface roughness C/SiC of the blades, or the loss of the material in the polar blisk. A performance shift was seen in the quasi-isotropic blisk as portions of the leading and trailing edges were lost. After the testing was completed, detailed inspections of the blisks were performed. The largest surprise was the polar blisk had a obvious crack in a single blade that was located nearly midspan which was not detected in test. The crack ran completely through the blade circumferenciary and through the radial length of the blade. However, the crack does not appear to extend into the blisk hub. Although the cause of the crack is still under investigation, the material appears to be tolerant of this crack, and other hairline cracks discovered under higher magnification. This bodies well for eventual use of this material in actual flight turbopumps where monolithic fracture toughness issues limit its use.

Genge, Gary G.↗

Wind Turbine Generator System Duration Test Report for the ARE 442 Wind Turbine

This test is being conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, four turbines are being tested at the NWTC as a part of this project. Duration testing is one of up to 5 tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality tests. The results of the testing provide manufacturers with reports that may be used for small wind turbine certification. The test equipment includes a grid connected ARE 442 wind turbine mounted on a 30.5 meter (100 ft) lattice tower manufactured by Abundant Renewable Energy. The system was installed by the NWTC Site Operations group with guidance and assistance from Abundant Renewable Energy.

17 WIND ENERGY↗

Safety and Function Test Report for the Viryd CS8 Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. Several turbines were selected for testing at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) as a part of the Small Wind Turbine Independent Testing project. Safety and function testing is one of up to five tests that may be performed on the turbines. Other tests include duration, power performance, acoustic noise, and power quality. Viryd Technologies, Inc. of Austin, Texas, was the recipient of the DOE grant and provided the turbine for testing.

17 WIND ENERGY↗

Cold flow testing of the Space Shuttle Main Engine high pressure fuel turbine model

In order to experimentally determine the performance of the Space Shuttle Main Engine (SSME) High Pressure Fuel Turbopump (HPFTP) turbine, a 'cold' air flow turbine test program was established at NASA's Marshall Space Flight Center. As part of this test program, a baseline test of Rocketdyne's HPFTP turbine has been completed. The turbine performance and turbine diagnostics such as airfoil surface static pressure distributions, static pressure drops through the turbine, and exit swirl angles were investigated at the turbine design point, over its operating range, and at extreme off-design points. The data was compared to pretest predictions with good results. The test data has been used to improve meanline prediction codes and is now being used to validate various three-dimensional codes. The data will also be scaled to engine conditions and used to improve the SSME steady-state performance model.

Hudson, Susan T.↗

Wind Turbine Generator System Duration Test Report for the Mariah Power Windspire Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, five turbines are being tested at the National Wind Technology Center (NWTC) as a part of the first round of this project. Duration testing is one of up to five tests that may be performed on the turbines. Other tests include power performance, safety and function, noise, and power quality tests. NWTC testing results provide manufacturers with reports that may be used to meet part of small wind turbine certification requirements. This duration test report focuses on the Mariah Power Windspire wind turbine.

17 WIND ENERGY↗

Spin test of turbine rotor

Experimental data are presented for the tangential and radial stresses in the disks of the 36,000 horsepower, 4000 rpm turbine for the M-1 engine oxidizer turbopump. The two-stage Curtis turbine is a special light-weight design utilizing thin conical disks with hollow sheet metal blades attached by electron-beam welding techniques. The turbine was fabricated from Inconel 718, a nickel-chromium alloy. The stresses were obtained by strain-gage measurements using a slip-ring assembly to transmit the electrical signals. Measurements were made at different rotative speeds and different thermal loads. In addition to presenting test data, the report describes test equipment, design of associated hardware, test procedures, instrumentation, and tests for the selection and calibration of strain gages.

Vavra, M. H.↗

Assessing and Testing Hydrokinetic Turbine Performance and Effects on Open Channel Hydrodynamics: An Irrigation Canal Case Study.

Hydrokinetic energy from flowing water in open channels has the potential to support local electricity needs with lower regulatory or capital investment than impounding water with more conventional means. MOU agencies involved in federal hydropower development have identified the need to better understand the opportunities for hydrokinetic (HK) energy development within existing canal systems that may already have integrated hydropower plants. This document provides an overview of the main considerations, tools, and assessment methods, for implementing field tests in an open-channel water system to characterize current energy converter (CEC) device performance and hydrodynamic effects. It describes open channel processes relevant to their HK site and perform pertinent analyses to guide siting and CEC layout design, with the goal of streamlining the evaluation process and reducing the risk of interfering with existing uses of the site. This document outlines key site parameters of interest and effective tools and methods for measurement and analysis with examples drawn from the Roza Main Canal, in Yakima, WA to illustrate a site application.

13 HYDRO ENERGY↗

Current turbines mobile test vessel (final technical report)

This report summarizes the final design of a Mobile Test Vessel (MTV) submitted to the Department of Energy (DOE) under the award DE-EE0009452 as part of the Funding Opportunity Announcement (FOA) DE-FOA-0002234: Water Power Technologies Office 2020 Research Funding Opportunity, Topic Area 4: Current Energy Technology Testing Infrastructure. This project was performed by IDOM in partnership with Florida Atlantic University’s (FAU) Southeast National Marine Renewable Energy Center (SNMREC).

16 TIDAL AND WAVE POWER↗

Comparison of heat transfer characteristics of three cooling configurations for air-cooled turbine vanes tested in a turbojet engine

A comparison was made of the heat transfer characteristics of three air cooled vanes. The vanes incorporated cooling schemes such as impingement cooling, film cooling, and convection cooling with and without extended surfaces. A redesign study was made for two vanes to improve the cooling effectiveness. An average impingement heat transfer coefficient was calculated on the bases of experimentally determined temperatures at the leading edge and a one dimensional heat transfer calculation. This heat transfer coefficient was compared with existing impingement heat transfer correlations.

Yeh, F. C.↗

Highly loaded multi-stage fan drive turbine-cascade test program

Test results are presented for 19 cascades involving five plain and two tandem blade sections. High camber and/or negative reaction is associated with six of the sections. Exit Mach numbers range up to slightly above sonic. Cascade efficiency, exit flow angle and static pressure, and blade surface pressure data are reported with incidence angle, Mach number, solidity, and relative position of the tandem blades as independent variables.

Cherry, D. G.↗