Polarimetric Hyperspectral Imaging
JPL developed a prototype system for evaluating potential applications of a polarimetric hyperspectral imaging (PHI) technology using the noncollinear acousto-optic tunable filter (AOTF).
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
JPL developed a prototype system for evaluating potential applications of a polarimetric hyperspectral imaging (PHI) technology using the noncollinear acousto-optic tunable filter (AOTF).
Recent development of a polarimetric hyperspectral imaging (PHSI) prototype sensor system that uses an acousto-optic tunable filter (AOTF) as a wavelength sorter and a polarizing beam splitter.
This paper reports results of a recent field experiment using a prototype system to evaluate the acousto-optic tunable filter polarimetric hyperspectral imaging technology for target detection applications.
This paper reports results from an analysis of polarimetric hyperspectral imagery collected using a prototype acousto-optic tunable filter (AOTF) instrument in an outdoor environment. Spectra, derivative spectra, and polarization spectra in the image cube form were studied. The issue concerns spectral and polarization signatures of vegetation, contributions due to aerosol, and man-made object detection. The result illustrates potentials of the technology for a variety of remote sensing applications.
The acousto-optic tunable filter (AOTF) devices are used in a variety of applications including hyperspectral and spectrapolarimetric based imaging. The AOTF devices provide several advantages including speed and random access to desired spectral bands and enable all-solid-state operation that are attractive for space applications. In this paper, the performance of Tellurium Dioxide (TeO 2 ) and Mercurous Bromide (Hg 2 Br 2 ) AOTF devices in space environment carried out under the NASA’s Materials International Space Station Experiments 11 (MISSE-11) mission is discussed. The purpose of the MISSE-11 mission was to study materials and devices subjected to space conditions for long term while attached to the International Space station (ISS). The TeO 2 AOTF was developed for short wavelength IR (SWIR) operation while the Hg 2 Br 2 AOTF device was developed for long wavelength IR (LWIR) operation. These devices were attached to the ISS platform for more than a year. Pre-flight and post-flight performance characterization were performed on these devices. In the case of TeO 2 AOTF, the preflight efficiency was around 87% with a center frequency at 68MHz while the post-flight efficiency was around 83%. However, the optical transmission of Hg 2 Br 2 AOTF had deteriorated considerably. The details of performance testing and analysis of both AOTF devices are discussed.
Incorporation of acousto-optical tunable filter (AOTF) in cavity of solid-state laser, provides means of adjusting wavelength of laser output electronically, according to recent proposal. Output wavelength randomly selected in microseconds. Technique useful in remote-sensing applications, such as in differential-absorption lidar (DIAL) and in communications for wavelength-division multiplexing.
The mid-wave infrared (MWIR) spectrum contains a wealth of invaluable information including the spectral ‘fingerprint’ of many chemical species and has applications in remote sensing and astronomical imaging. Traditionally, filtering for the MWIR is achieved by means of passive multilayer interference (dichroic) filters, Fabry-Perot-based micro-electro-mechanical system (MEMS) filters, liquid crystal tunable filters, and focal plane array (FPA) filters. For accurate multispectral imaging applications, these approaches suffer from various limitations such as: having moving parts; exhibiting slow response times, and; having limited spectral bandwidth / resolution. Recently, there has been significant interest toward ‘active’ spectral imaging technologies, whereby the ability to provide electrically tunable narrowband filtering—spanning the entire MWIR—is highly desirable. In this work we introduce a new spectral imaging technology, namely actively tunable optical transmission filters using the phase-change material (PCM) GexSbyTez (GST). The GST exhibits a large, reversible change in its refractive index across the MWIR upon a phase transition (from amorphous to crystalline). This refractive index modulation governs the filter’s optical characteristics. Through an optical stimulus or applied voltage—which changes the GST state from amorphous to crystalline—one can actively tune the filter with MHz speed. We incorporate GST into optimized guided mode resonance (GMR) and plasmonic nanohole array (PNA) device architectures, enabling <10nm spectral resolution and tunable operation across 3~5µm. Our proposed PCM-MWIR filter will be able to extract the maximum amount of ‘useful’ information within the atmosphere for remote Earth sensing measurements at operational speeds orders of magnitude faster than current airborne-based sensors. Moreover, it may enable affordable SmallSat-based MWIR instrumentation which is complimentary to other observation systems. The MISSE (Materials International Space Station Experiment-Flight Facility) experiment has been proposed as a testbed for a PCM-based tunable MWIR filter module to allow exposure of the module to the low Earth orbit space environment. This will provide valuable data regarding the robustness of the filter to withstand the radiation and atomic oxygen environment and allow assessment of the technology for use in space applications.
Surface plasmon tunable filter is a new technology under development at the Jet Propulsion Laboratory. This technology can be used to build a tunable mirror.
Ground-based, narrow-band, high throughput optical filters are required for optical links from deep space. We report on the development of a tunable filter assembly that operates at telecommunication window of 1550 nanometers. Low insertion loss of 0.5 decibels and bandwidth of 90 picometers over a 2000 nanometers operational range of detectors has been achieved.
Omnidirectional photonic band gaps (PBGs) are found in one-dimensional ternary plasma photonic crystals (PPC) composed of single negative metamaterials. The band characteristics and transmission properties are investigated through the transfer matrix method. We show that the proposed structure can trap light in three-dimensional space due to the elimination of Brewster's angle transmission resonance allowing the existence of complete PBG. The results are discussed in terms of incident angle, layer thickness, dielectric constant of the dielectric material, and number of unit cells (N) for TE and TM polarizations. It is seen that PBG characteristics is apparent even in an N ≥ 2 system, which is weakly sensitive to the incident angle and completely insensitive to the polarization. Finite PPC could be used for multichannel transmission filter without introducing any defect in the geometry. We show that the locations of the multichannel transmission peaks are in the allowed band of the infinite structure. The structure can work as a single or multichannel filter by varying the number of unit cells. Binary PPC can also work as a polarization sensitive tunable filter.
It is argued that the next generation of imaging spectrometers will need greater capabilities and more flexibility than the High Resolution Imaging Spectrometer (HIRIS) and the Moderate Resolution Imaging Spectrometer (MODIS), which were designed for the first Earth Observation System platform. The emerging technology that represents a major advance in the scientific utility of imaging spectrometry is the acoustooptic tunable filters, (AOTFs). AOTFs are compact robust solid-state crystals which provide rapid (millisecond) electronically-controlled spectral tunability. This paper discusses the evolving requirements of imaging spectrometers and examines the basic system parameters of the HIRIS and the MODIS concepts involving the use of AOTFs, which will satisfy these requirements.
We report on YBCO/strontium titanate (STO) thin film K-band tunable bandpass filters on lanthanum aluminate substrates. The 2 pole filters were designed for a center frequency of 19 GHz and 4% bandwidth. Tunability is achieved through the non-linear dc electric field dependence of the relative dielectric constant of STO (epsilon-rSTO). Center frequency shifts greater than 2 GHz were obtained at a 400V bipolar dc bias at temperatures below 77K, with minimum degradation in the insertion loss of the filters.
Micromachined Fabry-Perot tunable filters with a large clear aperture (12.5 to 40 mm) are being developed as an optical component for wide-field imaging 1:1 spectroscopy. This program applies silicon micromachining fabrication techniques to miniaturize Fabry-Perot filters for astronomical science instruments. The filter assembly consists of a stationary etalon plate mated to a plate in which the etalon is free to move along the optical axis on silicon springs attached to a stiff silicon support ring. The moving etalon is actuated electrostatically by electrode pairs on the fixed and moving etalons. To reduce mass, both etalons are fabricated by applying optical coatings to a thin freestanding silicon nitride film held flat in drumhead tension rather than to a thick optical substrate. The design, electro-mechanical modeling, fabrication, and initial results will be discussed. The potential application of the miniature Fabry-Perot filters will be briefly discussed with emphasis on the detection of extra-solar planets.
Electron cyclotron emission (ECE) diagnostics that use variable location channels based on yttrium iron garnet (YIG) bandpass filters improve the precision and the efficiency of measurements of electron temperature (T e ) profiles and fluctuations (δT e ). These variable frequency filters were substituted for fixed frequency filters in the intermediate frequency section to achieve the required higher resolution over a target radial range, just before the experiment. In this paper, we present the proof-of-principle for high temporal resolution measurement of the electron temperature gradient, via real-time slewing of a YIG filter for relocation of an ECE channel during a long pulse. The key component is the application of YIG tunable filters with their narrow bandwidth and capability for a high slew rate of their center frequency. This application permits fast relocation of the ECE channels for direct measurement of the gradient and close spacing of channels to investigate the magnetic island’s dynamic behavior.
Fabry-Perot interferometer are simple elegant, tunable filters that can be used to make compact hyperspectral thermal imaging system. To foster the development of these sensors, software tools for the design and simulation of tunable Fabry-Perot infrared imagers have been developed. The tools are provided at three levels: basic, design, and system. Basic tools describe a nearly ideal Fabry-Perot filter with perfectly flat and parallel mirrors in collimated space. Design tools that take into account non-ideal behavior such as mirror and collimation defects calculate free spectral range, finesse, and spectral width of the interferometer. System tools help analyze an integration of the Fabry-Perot filter into a camera system. They include spectral convolution, first-order optical layout, and an estimation of signal-to-noise ratio. The complete set of tools allows for simulations of system operation and performance with various illumination sources. Spectral images generated in such simulations were used to examine applicability of Fabry-Perot system in remote sensing of atmospheric gases including detection of environmental pollutants and hazardous gases. Different operating conditions and system configurations are presented.
SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.
In an effort to develop a mechanically robust, high throughput and solid state spectrometer several liquid crystal Fabry-Perot etalons were constructed. The etalons were tested for spectral response, radiation resistance and optical transmission. The first year of this project was spent developing and understanding the properties of the liquid crystal etalons; in the second year an intensified all-sky imaging system was developed around a pair of LC etalons. The imaging system, developed jointly with SRI International represents a unique brassboard to demonstrate the use of LC etalons as tunable filters. The first set of etalons constructed in year one of this project were tested for spectral response and throughput while etalon surrogates were exposed to proton radiation simulating the exposure of an object in Low Earth Orbit (LEO). The 2" diameter etalons had a measure finesse of approximately 10 and were tunable over five orders. Liquid crystals exposed to proton irradiation showed no signs of damage. In year two two larger diameter (3") etalons were constructed with gaps of 3 and 5 microns. This pair of etalons is for use in a high resolution, all-sky spectral imager. The WATUMI imager system follows the heritage of all sky, narrow band, intensified imagers however it includes two LC Fabry-Perot etalons to provide tunability and the ability to switch wavelengths rapidly, an import consideration in auroral airglow imaging. This work also resulted in two publications and one poster presentation. The instrument will be uniquely capable, with superior throughput and speed, to measure optical airglow of multiple emission lines in harsh conditions.
Recent advances in liquid crystal technology have enabled us to construct tunable birefringent filters with bandwidths between approximately 0.1 nm and 50 nm. The center wavelength of these filters can be selected electronically, in a few tens of milliseconds, with no moving parts. These liquid crystal tunable filters (LCTF's), together with existing CCD detectors, make possible a new generation of lightweight, rugged, high-resolution imaging spectrophotometers. Such instruments would be particularly interesting for remote sensing applications from geosynchronous platforms. Important advantages exist in the aperture, absence of image shift, power consumption, size, weight, and absence of high drive frequencies, compared to current instruments used or considered for multispectral scene analysis. In the present work, we have reviewed spectral requirements of planned NASA geosynchronous remote sensing missions and identified several applications of the liquid crystal tunable filter technology. We have modeled the LCTF performance in the visible and near-infrared, and carried out a literature study on space-hardening of the filter components, to evaluate the suitability of LCTF's for geosynchronous missions. We have also compared the power consumption, weight, size, reliability, and optical performance of an imaging spectrophotometer using a LCTF monochromator, to other instruments that have been put forward for remote sensing from geosynchronous platforms. We put forward some conceptual designs for LCTF's that seem to offer important reliability, over the mechanical filter wheels presently baselined for the HEPI and ALM experiments. The extremely wide acceptance angle achievable with LCTF's could also avoid the present need for large-aperture interference filters in the ALM (and LIS) experiments. Thermal vacuum testing and radiation damage analysis is required to investigate the space hardening of these new filters for geosynchronous flight.