Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transit bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a DC Distribution Testbed for High-Power EV Charging

This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-modal Energy-optimal Trip Scheduling in Real-time (METS-R) for Transportation Hubs (Final Report)

This report summarizes the work performed under the award number EE0008524. The project develops the Multi-modal Energy-optimal Trip Scheduling in Real-time (METS-R) platform as the next-generation transportation solution based on autonomous electric vehicles (AEV) serving passenger trips from and to urban transportation hubs, to substantially reduce transportation energy consumption. Extensive data collection and analyses were first conducted to understand the demand patterns and energy consumption of hub-based on-road trips. Then, a data-driven framework that consists of an analytical module and a simulation module was proposed. For the analytical module, five planning + operation tools were developed to support the planning and energy-efficient operations of urban AEV services: the charging station planning that robotically allocates charging supplies based on the stationary charging demand distribution; the transit planning and demand adaptive scheduling model that efficiently generates\ candidate transit routes from hubs to other places and dynamically adjusts the transit time table to fit the current demand; the online energy-efficient routing that learns the energy-optimal paths from observations of link-level energy consumption in real-time; the hub-based ridesharing that matches trip requests together with account for the uncertainty of future trip demand and vehicle supply; and finally, the integrated demand prediction and anomaly detection pipeline that leverages the flight/train time table and support other planning/operation tools. To demonstrate the performance of these tools, a scalable high-performance agent-based simulator was built. We divided the urban space into multiple service zones where each zone was considered as an agent for passenger generation and vehicle charging. Two types of AEV agents were coded to model two types of mobility services: AEV taxi and AEV transit. For the AEV taxi, the team implemented the functions of pickup/drop-off passengers, energy-efficient routing, ridesharing, fleet rebalancing, and recharging. For the AEV bus, the team implemented the functions of demand-adaptive route scheduling, passenger boarding, and recharging. A high-performance computing framework was introduced to receive various profiling information (such as link energy updates, vehicle speed) from the simulator instances and communicate the operational commands back to the instances. The numerical experiments show that each of the proposed operational algorithms can reduce energy consumption and improve system efficiency. Furthermore, there exists the need to collectively consider multiple planning + operational strategies as multiple strategies can influence each other in terms of performance impacts. Recommendations for future work related to AEV planning and simulation are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Systems engingeering for the Kepler Mission : a search for terrestrial planets

The Kepler mission will launch in 2007 and determine the distribution of earth-size planets (0.5 to 10 earth masses) in the habitable zones (HZs) of solar-like stars. The mission will monitor > 100,000 dwarf stars simultaneously for at least 4 years. Precision differential photometry will be used to detect the periodic signals of transiting planets. Kepler will also support asteroseismology by measuring the pressure-mode (p-mode) oscillations of selected stars. Key mission elements include a spacecraft bus and 0.95 meter, wide-field, CCD-based photometer injected into an earth-trailing heliocentric orbit by a 3-stage Delta II launch vehicle as well as a distributed Ground Segment and Follow-up Observing Program. The project is currently preparing for Preliminary Design Review (October 2004) and is proceeding with detailed design and procurement of long-lead components. In order to meet the unprecedented photometric precision requirement and to ensure a statistically significant result, the Kepler mission involves technical challenges in the areas of photometric noise and systematic error reduction, stability, and false-positive rejection. Programmatic and logistical challenges include the collaborative design, modeling, integration, test, and operation of a geographically and functionally distributed project. A very rigorous systems engineering program has evolved to address these challenges. This paper provides an overview of the Kepler systems engineering program, including some examples of our processes and techniques in areas such as requirements synthesis, validation & verification, system robustness design, and end-to-end performance modeling.

systems engineering↗

Innovative Thermal Management & Control to Surmount Challenges of Exploring Ocean Worlds on Europa and Enceladus

Probes to penetrate the thick ice shells of our solar system’s Ocean Worlds have been studied for nearly 20 years, since scientific evidence strongly suggested a subsurface ocean on the Jupiter moon called Europa. There is keen scientific interest in exploring four significant themes on such proposed missions: 1) Geodynamics, 2) Geochemistry, 3) Habitability, and 4) Life Detection. The ice shells of Ocean Worlds are predicted to be up to 40 km thick; they exhibit extreme thermal environments, with ice temperatures from 100 K to 270 K, and extreme pressure environments from vacuum to 53 MPa. Jet Propulsion Laboratory has conducted a broad-look investigation of proposed mission concepts to Europa to identify the significant technology and operational challenges of Europa ice-penetration. The thermal-mechanical system (TMS) of an ice penetration probe (IPP) designed to access the ocean of an icy moon using radioisotope thermoelectric generators for heat and power faces technological hurdles exacerbated by severe thermal and volume constraints. This study identified thermal management and control (TMC) challenges that are strongly linked to: ice penetration start-up, mobility and navigation in the ice, communications while in the ice sheet, and detecting and avoiding in-ice hazards. The major objectives of the TMC system are: 1) Absorb internal thermal energy from the IPP radioisotope power source, 2) Maintain liquid water conditions around the IPP at all times, 3) Manage and control thermal flows from probe nose to tail, and 4) Provide pressure containment for all internal probe components. This work discusses the baseline TMC system architecture and design developed to accomplish these objectives, and survive and transit the extreme ice thicknesses in pursuit of Icy/Ocean Worlds science goals. The proposed TMC system consisting of an internal pumped two-phase fluid loop “thermal bus” for thermal energy capture, variable conductance heat pipe system for passively adaptive thermal energy transport around the probe, and water jetting system for ice cutting is described and discussed. Critical testing performed to date is described.

Lee, Kuan-Lin↗

Identification of Intraday False Data Injection Attack on DER Dispatch Signals

The urgent need for the decarbonization of power grids has accelerated the integration of renewable energy. Concurrently, increasing distributed energy resources (DER) and advanced metering infrastructure (AMI) have transformed the power grids into a more sophisticated cyber-physical system with numerous communication devices. While these transitions provide economic and environmental value, they also impose increased risk of cyber attacks and operation al challenges. This paper investigates the vulnerabilit y of the power grids with high renewable penetration against an intraday false data injection (FDI) attack on DER dispatch signals and proposes a kernel support vector regression (SVR) based detection model as a countermeasure. The intraday FDI attack scenario and the detection model are demonstrated in a numerical experiment using the HCE 187-bus test system.

Kim, Jip↗

Vehicle-Cycle Inventory for Type C School Buses & Intra-City Transit Buses

This report documents the new inventory incorporated into the Research and Development version of Greenhouse gases, Regulated Emissions, and Energy use in Technologies (R&D GREET) 2025 model for the vehicle cycle of Type C school buses and intracity transit buses. The transportation sector contributes significantly to the United States’ energy consumption and resultant emissions (EPA, 2025a). However, public transit plays an important role in mitigating these impacts because it consumes a relatively low amount of energy per passenger (Congressional Budget Office, 2022). Public transit is widely used in the United States; more than 500,000 school buses (EPA, 2025b) and ~75,000 service buses (American Public Transportation Association, 2025) operate in the nation. These are primarily internal combustion engine vehicles (ICEVs) powered by diesel. Original equipment manufacturers (OEMs) are making efforts to electrify U.S. bus fleets by using batteries as a propulsion system to replace internal combustion engines. Electrification can reduce tailpipe emissions, such as particulate matter (with a diameter ≤10 µm [PM 10 ] and with a diameter ≤2.5 µm [PM 2.5 ]) and nitrogen oxides (Jonas et al., 2025; Martinez and Samaras, 2024; EPA, 2025b; Wayne et al., 2009). Hence, any energy and emission impact analysis of public transit must consider both conventional ICEVs and upcoming electric vehicle (EV) options for the school and transit buses that dominate this landscape. To understand the detailed environmental impact profiles of ICEV and EV school and transit buses, it is necessary to conduct a thorough analysis covering both vehicle manufacturing and vehicle use stages. The current literature lacks a detailed vehicle-cycle inventory for school and transit buses, which makes this kind of comparison difficult. To overcome this gap, we developed a comprehensive vehicle-cycle model for school and transit buses in Argonne’s R&D GREET 2025 model. The model is flexible in handling user inputs for key assumptions, such as component weights and material compositions, upstream energy sources for material processing, and vehicle operating parameters, to understand their impacts on energy use and emissions for both school and transit buses. This report is organized as follows: Section 2 provides details on the modeling approach and vehicle specifications (weights and composition of different vehicle components, and vehicle operating parameters) for both school and transit buses. Section 3 provides details on vehicle assembly, disposal, and recycling (ADR) approaches for the two buses. Section 4 includes details about their incorporation into the R&D GREET model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transit Habitat Concept and Mars Analog in Cislunar Orbit

- Transit Habitat Overview - Supports 4-crew during Lunar-Mars Analog missions leading up to a 700-1110-day Mars mission - Hybrid inflatable-metallic habitat structure - Launched commercially and outfitted with logistics in cis-lunar orbit (NRHO) - Docks w/ an interim propulsion bus or Gateway for first ~5 years until Mars Propulsion System (MPS) elements available - Extends Gateway operations beyond 60 days - Contingency Airlock and EVA capability - Planned reuse for multiple missions over 15-year lifetime - Builds on ISS and commercial investment in deep space habitation - Mid-2030s launch with late 2030s Mars Departure

Mars↗

Grid-Aware Charging and Operational Optimization for Mixed-Fleet Public Transit

The rapid growth of urban populations and the increasing need for sustainable transportation solutions have prompted a shift towards electric buses in public transit systems. However, the effective management of mixed fleets consisting of both electric and diesel buses poses significant operational challenges. One major challenge is coping with dynamic electricity pricing, where charging costs vary throughout the day. Transit agencies must optimize charging assignments in response to such dynamism while accounting for secondary considerations such as seating constraints. This paper presents a comprehensive mixed-integer linear programming (MILP) model to address these challenges by jointly optimizing charging schedules and trip assignments for mixed (electric and diesel bus) fleets while considering factors such as dynamic electricity pricing, vehicle capacity, and route constraints. We address the potential computational intractability of the MILP formulation, which can arise even with relatively small fleets, by employing a hierarchical approach tailored to the fleet composition. By using real-world data from the city of Chattanooga, Tennessee, USA, we show that our approach can result in significant savings in the operating costs of the mixed transit fleets.

Sen, Rishav↗

FleetREDI Insight: Intrastate Coach Bus Dataset

Capturing real-world data is critical to improving efficiency and supporting technology advancements in commercial vehicles. FleetREDI’s insights provide detailed duty cycle information and highlight unique aspects of the given dataset. Each insight delivers a quick look at the collected data by summarizing the operation and identifying key findings of the initial analysis. This FleetREDI insight explores coach buses operating in Colorado. Coach buses are a primary mover for intrastate transit and are primarily used for longer trips with more comfortable seats and a restroom. All Aboard America! Holdings Inc. offers various fixed-service and charter routes across Colorado on its Bustang fleet out of its depot in Golden, Colorado. NLR installed logging devices and collected operational data on nine 40-foot Bustang motorcoaches operating on fixed routes from May through August 2022. Using NLR’s FleetREDI data platform, this dataset provides a summary of daily operation to help understand duty cycle characteristics. This includes daily distance, fuel use, and estimated engine-produced energy consumption for nine motorcoaches that operated more than 33,000 miles. These vehicles primarily operated on Interstate 25 and Interstate 70. ![FleetREDI interstate bus](FleetREDI-interstate-bus.jpg)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

Approximation of the Frequency-Amplitude Curve Using the Homotopy Analysis Method

The Frequency-Amplitude (F-A) curve on power system oscillation under a large disturbance characterizes how a natural oscillation mode transitions to nonlinear oscillations with growing amplitudes and decaying frequencies. The existing formulation of the F-A curve is derived by solving elliptical integrals on oscillation of a single-machine-infinite-bus equivalent about the targeted oscillation mode. The formula is in a form of infinite series and needs to sum a large number of terms for satisfactory accuracy. This paper introduces an explicit, approximate expression obtained from the Homotopy Analysis Method on the F-A curve. The proposed F-A curve expression is derived from an SMIB system and verified on the IEEE 3-machine 9-bus system to show how the oscillation frequency of a dominant mode varies with oscillation amplitude under large disturbances.

frequency-amplitude (F-A) curve↗

Impact of Detailed Parameter Modeling of Open-Cycle Gas Turbines on Production Cost Simulation: Preprint

Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.

economic dispatch↗

MicroPPT-Based Secondary/Backup ACS for a 160-m, 450-kg Solar Sail Spacecraft

Solar sail tip-mounted, lightweight pulsed plasma thrusters (PPTs) are proposed for a secondary (or backup) attitude control system (ACS) of a 160-m, 450-kg solar sail spacecraft of the Solar Polar Imager (SPI) mission. A propellantless primary ACS of the SPI sailcraft employs trim control masses running along mast lanyards for pitch/yaw control together with roll stabilizer bars at the mast tips for quadrant tilt (roll) control. The robustness of such a propellantless primary ACS would be further enhanced by a secondary ACS utilizing tip-mounted, lightweight PPTs. The microPPT-based ACS is intended mainly for attitude recovery maneuvers from various off-nominal conditions that cannot be reliably handled by the propellantless primary ACS. However, it can also be employed for: i) the checkout or standby mode prior to and during sail deployment, ii) the post-deployment transition mode (prior to the propellantless primary ACS mode operation), iii) the solar sailing cruise mode of a trimmed sailcraft, and iv) the spin-stabilized, sun-pointing, safe mode. Although a conventional bus ACS is required for the SPI mission as the sail is jettisoned at the start of its science mission phase, the microPPT-based ACS option promises greater redundancy and robustness for the SPI mission. For other sailing missions, where the sail is never jettisoned, this secondary ACS provides a lower-cost, lower-mass propulsion for deployment control and greater redundancy than any traditional reaction-jet control system. This paper presents an overview nf the state--of-the--art microPPT technology, the design requirements of microPPTs for solar sail attitude control, and the preliminary ACS design and simulation results.

Wie, Bong↗

Support and power plant documentation for the gas turbine powered bus demonstration program

The operational experience obtained for the GT404-4 gas turbine engines in the intercity and intracity Bus Demonstration Programs is described for the period January 1980 through September 1981. Support for the engines and automatic transmissions involved in this program provided engineering and field service, spare parts and tools, training, and factory overhauls. the Greyhound (intercity) coaches accumulated 183,054 mi (294,595 km) and 5154 hr of total operation. The Baltimore Transit (intracity) coaches accumulated 40,567 mi (65,285 km) and 1840 hr of total operation. In service, the turbine powered Greyhound and Transit coaches achieved approximately 25% and 40% lower fuel mileage, respectively, than did the production diesel powered coaches. The gas turbine engine will require the advanced ceramic development currently being sponsored by the DOE and NASA to achieve fuel economy equivalent not only to that of today's diesel engines but also to the projected fuel economy of the advanced diesel engines of the 1990s. Sufficient experience was not achieved with the coaches prior to the start of service to identify and eliminate many of the problems associated with the startup of new equipment. Because of these problems, the mean miles between incident were unacceptably low. The future gas turbine system should be developed sufficiently to establish satisfactory durability prior to evaluation in revenue service. Commercialization of the gas turbine bus engine remains a viable goal for the future.

Nigro, D. N.↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10× reduction in the current ripple compared to normal operation.

cascaded converter↗

Electrifying Transit: A Guidebook for Implementing Battery Electric Buses

This guidebook is organized to give transit decision-makers and relevant stakeholders an overview of BEB facts, data, and considerations important for planning their implementation in a variety of jurisdictions. First, the benefits and barriers for BEB are identified. Second, BEB basics in terms of the major components, including a) the bus, b) the battery, and c) the numerous charging options. BEB introduces new, high demand loads as the buses are charging and thus have a number of interactions with the electricity grid and the utility, which are explored third. Operation and maintenance of BEBs are considered fourth as BEBs should not be operated and maintained in the same approach as diesel buses. Fifth, the costs of BEB prices are summarized – and the choices of bus and battery are explored in how they impact BEB prices. Funding and financing options that support BEBs and their charging stations are also explored. Safety is a key consideration for BEBs and the guidebook touches upon codes and standards, hazards, and emergencies. The final section examines project execution, bringing together information from all the other sections so that long-term planning, route analysis, and fleet and infrastructure planning can be considered in the preparation of BEB deployment, and then deployment can be evaluated on a regular basis. A final conclusion revisits the information covered in the guidebook.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters: Preprint

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10 times reduction in the current ripple compared to normal operation.

41 EE - Solar Energy Technologies Office (EE-4S)↗