Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Anelastic response of the earth to a dip slip earthquake

The deformation induced by a vertical dip slip earthquake is examined using a variety of rheologic models. In this way the complications of dipping faults are avoided, and the phenomenon of transient peripheral warping is clearly revealed. A thrust fault dipping at 30 deg is investigated, and the important effects of dip and the existence of a slab on the asymmetry of strain pulses propagated into the overthrust and subducted lithosphere are demonstrated. One of the signal results of the study is the essential similarity of the strain patterns for Newtonian and non-Newtonian flow laws: the two rheologies give nearly identical strain field geometries. The principal difference between the two, which is readily observable, is in their time evolution. Relaxation in non-Newtonian rheologies tends to be initially fast, then slow at times that are late in comparison with relaxation in a Newtonian rheology. The possibility of simply recalling the time dependence of a Newtonian solution to obtain an approximate solution to a non-Newtonian problem is demonstrated.

Melosh, H. J.↗

An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

propulsion system performance↗

An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

propulsion system performance↗

An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

systems health monitoring↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Study the Protection Improvements for a Weak Grid Area With High IBRs

NLR is collaborating with Florida Power & Light (FPL) and GE to investigate power system stability and protection reliability challenges in a weak-grid region with high penetration of inverter-based resources (IBRs). This presentation will primarily focus on the protection aspects of the study. We will share key insights from this real-world project, including best practices for developing high-fidelity fault study models, establishing a controller-hardware-in-the-loop (CHIL) platform for testing physical relays, identifying system-level protection challenges, and designing enhanced protection schemes to address those issues. Through this discussion, the audience will gain practical understanding of protection studies in IBR-dominated systems, the emerging challenges associated with reduced fault current and altered transient behavior, and effective mitigation strategies. In particular, we will highlight the critical importance of IBR compliance with IEEE 2800-2022 to ensure dependable and secure protection relay operation in modern transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Nonlinear time-series-based adaptive control applications

A control design methodology based on a nonlinear time-series reference model is presented. It is indicated by highly nonlinear simulations that such designs successfully stabilize troublesome aircraft maneuvers undergoing large changes in angle of attack as well as large electric power transients due to line faults. In both applications, the nonlinear controller was significantly better than the corresponding linear adaptive controller. For the electric power network, a flexible AC transmission system with series capacitor power feedback control is studied. A bilinear autoregressive moving average reference model is identified from system data, and the feedback control is manipulated according to a desired reference state. The control is optimized according to a predictive one-step quadratic performance index. A similar algorithm is derived for control of rapid changes in aircraft angle of attack over a normally unstable flight regime. In the latter case, however, a generalization of a bilinear time-series model reference includes quadratic and cubic terms in angle of attack.

Mohler, R. R.↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data and results of a laboratory investigation of microprocessor upset caused by simulated lightning-induced analog transients

Advanced composite aircraft designs include fault-tolerant computer-based digital control systems with thigh reliability requirements for adverse as well as optimum operating environments. Since aircraft penetrate intense electromagnetic fields during thunderstorms, onboard computer systems maya be subjected to field-induced transient voltages and currents resulting in functional error modes which are collectively referred to as digital system upset. A methodology was developed for assessing the upset susceptibility of a computer system onboard an aircraft flying through a lightning environment. Upset error modes in a general-purpose microprocessor were studied via tests which involved the random input of analog transients which model lightning-induced signals onto interface lines of an 8080-based microcomputer from which upset error data were recorded. The application of Markov modeling to upset susceptibility estimation is discussed and a stochastic model development.

Belcastro, C. M.↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Reliability calculation using randomization for Markovian fault-tolerant computing systems

The randomization technique for computing transient probabilities of Markov processes is presented. The technique is applied to a Markov process model of a simplified fault tolerant computer system for illustrative purposes. It is applicable to much larger and more complex models. Transient state probabilities are computed, from which reliabilities are derived. An accelerated version of the randomization algorithm is developed which exploits ''stiffness' of the models to gain increased efficiency. A great advantage of the randomization approach is that it easily allows probabilities and reliabilities to be computed to any predetermined accuracy.

Miller, D. R.↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects

Researchers at New Mexico Tech, Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), and other collaborators are developing a methodology to improve characterization of stress in the subsurface by means of a model-based inversion of reservoir engineering data, time lapse seismic measurements, and microseismicity. Historically, various geophysical techniques have been used in efforts to understand the state of stress in the subsurface through direct and indirect imaging of stress sensitive features (faults and fractures) and observations of transient stress related observations (time variant elastic moduli and microseismicity). Standard direct and indirect techniques for seismic fault and fracture imaging suffer from detectability limits due to reliance on high data quality and multiplicity. Variations in effective elastic properties from inversion of high quality seismic (Vertical Seismic Profile (VSP)) data may be used to infer stress near the wellbore through integration with independent experimental characterization of the stress-velocity relationship. Given a sufficiently robust observation network, microseismic emissions may be inverted to characterize focal mechanisms which, together with supporting assumptions and constraints, inform estimates of in-situ stress. While each of these techniques contributes in part to the characterization of stress within limited spatial and temporal domains, no one method provides an unambiguous stress measurement or a predictive capability over a site scale spatial extent. Challenges associated with solution non-uniqueness, measurement ambiguity, and irregular sampling may be greatly minimized through combination of one or more of independent measurements within a common framework in which realistic geological, hydrodynamic, geomechanical, and seismological constituent process models may act as constraints.

02 PETROLEUM↗

Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme

A method detects and isolates in-flight sensor, actuator, and component faults for advanced propulsion systems. In sharp contrast to many conventional methods, which deal with either sensor fault or component fault, but not both, this method considers sensor fault, actuator fault, and component fault under one systemic and unified framework. The proposed solution consists of two main components: a bank of real-time, nonlinear adaptive fault diagnostic estimators for residual generation, and a residual evaluation module that includes adaptive thresholds and a Transferable Belief Model (TBM)-based residual evaluation scheme. By employing a nonlinear adaptive learning architecture, the developed approach is capable of directly dealing with nonlinear engine models and nonlinear faults without the need of linearization. Software modules have been developed and evaluated with the NASA C-MAPSS engine model. Several typical engine-fault modes, including a subset of sensor/actuator/components faults, were tested with a mild transient operation scenario. The simulation results demonstrated that the algorithm was able to successfully detect and isolate all simulated faults as long as the fault magnitudes were larger than the minimum detectable/isolable sizes, and no misdiagnosis occurred

Tang, Liang↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗