A lumped parameter mathematical model for simulation of subsonic wind tunnels

Equations for a lumped parameter mathematical model of a subsonic wind tunnel circuit are presented. The equation state variables are internal energy, density, and mass flow rate. The circuit model is structured to allow for integration and analysis of tunnel subsystem models which provide functions such as control of altitude pressure and temperature. Thus the model provides a useful tool for investigating the transient behavior of the tunnel and control requirements. The model was applied to the proposed NASA Lewis Altitude Wind Tunnel (AWT) circuit and included transfer function representations of the tunnel supply/exhaust air and refrigeration subsystems. Both steady state and frequency response data are presented for the circuit model indicating the type of results and accuracy that can be expected from the model. Transient data for closed loop control of the tunnel and its subsystems are also presented, demonstrating the model's use as a control analysis tool.

Krosel, S. M.↗

Numerical and Experimental Investigations on the Ignition Behavior of OME

On the path towards climate-neutral future mobility, the usage of synthetic fuels derived from renewable power sources, so-called e-fuels, will be necessary. Oxygenated e-fuels, which contain oxygen in their chemical structure, not only have the potential to realize a climate-neutral powertrain, but also to burn more cleanly in terms of soot formation. Polyoxymethylene dimethyl ethers (PODE or OMEs) are a frequently discussed representative of such combustibles. However, to operate compression ignition engines with these fuels achieving maximum efficiency and minimum emissions, the physical-chemical behavior of OMEs needs to be understood and quantified. Especially the detailed characterization of physical and chemical properties of the spray is of utmost importance for the optimization of the injection and the mixture formation process. The presented work aimed to develop a comprehensive CFD model to specify the differences between OMEs and dodecane, which served as a reference diesel-like fuel, with regards to spray atomization, mixing and auto-ignition for single- and multi-injection patterns. The simulation results were validated against experimental data from a high-temperature and high-pressure combustion vessel. The sprays’ liquid and vapor phase penetration were measured with Mie-scattering and schlieren-imaging as well as diffuse back illumination and Rayleigh-scattering for both fuels. To characterize the ignition process and the flame propagation, measurements of the OH* chemiluminescence of the flame were carried out. Significant differences in the ignition behavior between OMEs and dodecane could be identified in both experiments and CFD simulations. Liquid penetration as well as flame lift-off length are shown to be consistently longer for OMEs. Zones of high reaction activity differ substantially for the two fuels: Along the spray center axis for OMEs and at the shear boundary layers of fuel and ambient air for dodecane. Additionally, the transient behavior of high temperature reactions for OME is predicted to be much faster.

33 ADVANCED PROPULSION SYSTEMS↗

Multi-Agent Control Approach to the Stability of Linear Deployable Systems

Collisions and undesired dynamic responses may occur during the expansion phase of deployable elements on a spacecraft. This problem is more pronounced in large and complex deployable elements where characterization of transient dynamics using testing and simulation can be challenging. This paper introduces a multi-agent control theory approach to address the problem of collisions and transient behavior in deployable lattice systems. We introduce the graph theoretic and relative error vector-based state-space structures to represent the geometry of a lattice-based deploy system. We show that under the assumption of almost-strict dissipativity, the closed-loop feedback gains of the relative error dynamics are the spring and damper constants in the structure. Moreover, we introduce the control perspective of shaping transient dynamics using eigenstructure assignment and balanced coordinate transformation.

Pablos, Juan L. de↗

NUMERICAL MODELING OF A SOLID OXIDE FUEL CELL FOR USE IN REAL-TIME SIMULATION AND CYBER-PHYSICAL SYSTEMS

Cyber-physical systems provide a mechanism with which to investigate the physical phenomena and behavior of traditionally cost-prohibitive or otherwise fragile equipment. For the National Energy Technology Laboratory (NETL), this approach resulted in the Hybrid Performance (Hyper) facility which features a gas turbine-SOFC hybrid cycle utilizing real turbomachinery and a simulated SOFC stack. This allows for the investigation of combined cycle performance and control strategies, in an exhaustive manner, both without fear of destroying delicate state-of-the-art fuel cells, and with the full accuracy of real-world turbomachinery. Issues arose between the transient response of the SOFC model being limited to a sample time of 80 milliseconds, due to the calculation time of the SOFC model taking on average 40 milliseconds to calculate for a given timestep with spikes in calculation time reaching the 80 millisecond threshold. In order to be able to match the speed of transients from the turbomachinery and likewise better discern transient behavior, it was determined that the SOFC model must be optimized to operate at a sample time of 5 milliseconds. Therefore, it is necessary to optimize the SOFC model in order to decrease the calculation time from around 40 milliseconds, down to at the most 5 milliseconds. To do this, both the electrochemical algorithm and the thermal algorithm used to simulate the physical behavior of the SOFC are investigated to determine where improvements can be made. To this end the rootfinding numerical recipes of the electrochemical algorithm are investigated as the complex electrochemistry requires a highly iterative nested dual convergence loop to resolve the voltage-current relationship, and likewise the temporal discretization of the thermal algorithm is modified for the sake of higher accuracy and stability. Ultimately the new electrochemical algorithm featuring higher order rootfinding schemes proves to be efficient enough to reach the sub 5 millisecond target, signifying an order of magnitude reduction in calculation time, and when coupled with the new temporal discretization similar calculation time characteristics show that a fully implicit, higher order temporal discretization can also successfully be used if desired. Ultimately this result means that the cyber-physical simulation system can operate at higher sample rates, and resolve transient events at significantly higher resolution and fidelity.

Arias, Jesus↗

Design and Testing of a Water-Cooled Rotating Detonation Combustor at Elevated Operating Pressures - Abstract

This is an extended abstract being submitted for consideration that briefly describes the material that will be included in the final paper. This study will detail the design and testing of a water-cooled Rotating Detonation Combustor (RDC) that permits operation for extended periods of time ensuring that the device has reach a stable operating temperature. Extended run times also provides an opportunity to consider transient behaviors that occur as a result of altering the operating conditions such as equivalence ratio. The experimental setup is also unique in that it consists of a ducted exhaust with a downstream high-temperature valve that can control the pre-combustion pressure in the RDC independent of the combustor annulus and exit geometry. This paper will examine the results from the extended operation of the water-cooled RDC over a range of both transient and steady state equivalence ratios (0.5 - 1.0), pre-combustion operating pressures (0 - 207 kPa), mass flow rates (0.42 – 0.5 kg/sec) and air inlet throat area to combustor channel area ratios (0.09 – 0.32). All tests were performed while operating on hydrogen in air at a nominal air inlet temperature of 340 – 350 K. Limited data obtained at an elevated inlet air temperature of 480 K will also be discussed. Results suggest that under certain conditions the operating mode of the detonation wave can vary as it approaches a stable operating temperature. For the RDC tested, a stable operating temperature is not achieved until approximately 8-10 seconds of run time.

Ferguson, Donald↗

Investigation of Critical Heat Flux in Reduced Gravity Using Photomicrographic Techniques

Experiments were performed to examine the effects of body force on flow boiling critical heat flux (CHF). FC-72 was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface just prior to CHF. High-speed video imaging techniques were used to identify dominant CHF mechanisms corresponding to different flow orientations and liquid velocities. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed significant sensitivity to orientation for flow velocities below 0.2 m/s, where extremely low CHF values where measured, especially with downward-facing heated wall and downflow orientations. High flow velocities dampened the effects of orientation considerably. The CHF data were used to assess the suitability of previous CHF models and correlations. It is shown the Interfacial Lift-off Model is very effective at predicting CHF for high velocities at all orientations. The flooding limit, on the other hand, is useful at estimating CHF at low velocities and for downflow orientations. A new method consisting of three dimensionless criteria is developed for determining the minimum flow velocity required to overcome body force effects on near-saturated flow boiling CHF. Vertical upflow boiling experiments were performed in pursuit of identifying the trigger mechanism for subcooled flow boiling CHF. While virtually all prior studies on flow boiling CHF concern the prediction or measurement of conditions that lead to CHF, this study was focused on events that take place during the CHF transient. High-speed video imaging and photomicrographic techniques were used to record the transient behavior of interfacial features from the last steady-state power level before CHF until the moment of power cut-off following CHF. The video records show the development of a wavy vapor layer which propagates along the heated wall, permitting cooling prior to CHF only in wetting fronts corresponding to the wave troughs. Image analysis software was developed to estimate void fraction from the individual video images. The void fraction records for subcooled flow boiling show the CHF transient is accompanied by gradual lift-off of wetting fronts culminating in some maximum vapor layer mean thickness, following which the vapor layer begins to thin down as the transition to film boiling ensues. This study proves the Interfacial Lift-off Model, which has been validated for near-saturated flow boiling CHF, is equally valid for subcooled conditions.

Mudawar, Issam↗

Transient and Steady-state Tests of the Space Power Research Engine with Resistive and Motor Loads

The NASA Lewis Research Center (LeRC) has been testing free-piston Stirling engine/linear alternators (FPSE/LA) to develop advanced power convertors for space-based electrical power generation. Tests reported herein were performed to evaluate the interaction and transient behavior of FPSE/LA-based power systems with typical user loads. Both resistive and small induction motor loads were tested with the space power research engine (SPRE) power system. Tests showed that the control system could maintain constant long term voltage and stable periodic operation over a large range of engine operating parameters and loads. Modest resistive load changes were shown to cause relatively large voltage and, therefore, piston and displacer amplitude excursions. Starting a typical small induction motor was shown to cause large and, in some cases, deleterious voltage transients. The tests identified the need for more effective controls, if FPSE/LAs are to be used for stand-alone power systems. The tests also generated a large body of transient dynamic data useful for analysis code validation.

Rauch, Jeffrey S.↗

Influence of Transient Atmospheric Circulation on the Surface Heating of the Pacific Warm Pool

Analyses of data on clouds, winds, and surface heat fluxes show that the transient behavior of basin-wide large-scale circulation has a significant influence on the warm pool sea surface temperature (SST). Trade winds converge to regions of the highest SST in the equatorial western Pacific. These regions have the largest cloud cover and smallest wind speed. Both surface solar heating and evaporative cooling are weak. The reduced evaporative cooling due to weakened winds exceeds the reduced solar heating due to enhanced cloudiness. The result is a maximum surface heating in the strong convective and high SST regions. Data also show that the maximum surface heating in strong convective regions is interrupted by transient atmospheric and oceanic circulation. Due to the seasonal variation of the insolation at the top of the atmosphere, trade winds and clouds also experience seasonal variations. Regions of high SST and low-level convergence follow the Sun, where the surface heating is a maximum. As the Sun moves away from a convective region, the strong trade winds set in, and the evaporative cooling enhances, resulting in a net cooling of the surface. During an El Nino, the maximum SST and convective region shifts eastward from the maritime continent to the equatorial central Pacific. Following the eastward shift of the maximum SST, the region of maximum cloudiness and surface heating also shift eastward. As the atmospheric and oceanic circulation returns to normal situations, the trade winds increase and the surface heating decreases. We conclude that the evaporative cooling associated with the seasonal and interannual variations of trade winds is one of the major factors that modulate the SST distribution of the Pacific warm pool.

Chou, Ming-Dah↗

Numerical analysis of dynamic load following response in a natural circulation molten salt power reactor system

The Molten Salt Reactor (MSR) concept is a rapidly evolving Generation IV design that has recently attracted favorable attention due to the potential for reducing waste generation, realizing passive safety features, and seizing on the opportunity for cost effective economics. An investigation into the power transient behavior of an autonomous load-following, closed-loop, natural circulation MSR system is important to quantifying operational and safety performance under dynamic conditions. This paper presents the results of a STAR-CCM+ and a comparatively simple asymmetric, one-dimensional, numerical model to solve the compound dynamic MSR power behavior subject to flow and temperature reactivity feedback only. Results show that reactor power is affected by fuel salt flow velocity (global) and temperatures (local bulk volume averages) in a coupled, time-delayed manner that results in a unique compound dynamic, closed-loop power feedback mechanism. The 1-D simulation approach opens the possibility of performing inexpensive computations to evaluate time-dependent reactor performance relative to thermo-physical fuel salt limitations. Results also potentially motivate a convincing conclusion that natural circulation MSRs provide a leap in safety and reliability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Real-time evolution of texture and temperature during friction stir processing of a magnesium alloy: An operando neutron diffraction study

The real-time development of texture and the evolution of temperature during friction stir processing (FSP) of a Mg alloy were investigated using an operando neutron diffraction measurement. A novel approach was applied in this study where the real-time, quasi-steady state measurements performed as a function of position during FSP are converted to a Lagrangian dataset that reveals the transient behavior as a function of time. The in-situ FSP was carried out under two different thermo-mechanical processing conditions represented by the Zener-Hollomon parameter, Z. Further, the results show that: (i) a shear texture develops from the initial strong basal texture with the peak temperature reaching about 774 K during a low-Z processing and (ii) a strong off-normal texture develops with a peak temperature of 616 K during a high-Z processing. Moreover, time-temperature-texture diagrams were established to reveal the real-time development of the texture during the processing for both the low Z and high Z processing conditions. The changes in texture will be discussed in terms of plastic deformation mechanisms active during various stages of the FSP under the two different processing conditions.

36 MATERIALS SCIENCE↗

Improved multiphysics model of the High Temperature Engineering Test Reactor for the simulation of loss-of-forced-cooling experiments

We present a multiphysics model of the High Temperature Engineering Test Reactor for comparison with past and predict future loss-of-forced-cooling (LOFC) experiments. The approach selected combines (1) 3-D full-core superhomogenization-corrected neutronics, (2) 3-D full-core homogenized or semi-heterogeneous heat transfer (macroscale), (3) 2-D axisymmetric fuel rod heat transfer (mesoscale), and (4) 1-D thermal-hydraulics channels. Although large sensitivities remain and the available experimental data are insufficient for use in a rigorous validation exercise, the overall transient behavior is successfully reproduced. The novelty of our work includes (1) a new macroscale-mesoscale heat transfer coupling approach relying on gap conductance to drastically speed up numerical convergence by two orders of magnitude, (2) determination of a radial effective thermal conductivity that yields reasonably close results between the homogenized and semi-heterogeneous macroscale thermal models, and (3) a preliminary study of the reactor's early behavior following a LOFC event, thus enabling further assessment of numerical models against fission power measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Studies of the influence of heat pipe model and coupling strategy in heat pipe microreactor simulations using Sockeye

This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.

Direwolf↗

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

Physics-aware adaptive checkpointing with shadow systems for nonlinear PDE simulations

Large-scale simulations of nonlinear partial differential equations (PDEs) that exhibit strongly transient behavior and pattern-forming dynamics produce enormous amounts of data, which, even with modern storage systems, cannot be stored for later curation. Current I/O strategies either write dense time series of snapshots, which is often prohibitive in I/O and storage, or store a few checkpoints that enable restart but incur expensive recomputation cost and provide no control over post-restart error growth, especially when lossy compression is used. Moreover, most, if not all, existing strategies take no account of the actual physical state of the system. Here, we present a simple physics-aware I/O framework in which a low-cost shadow system adaptively triggers lossy checkpoints when the shadow system deviates from the fine-scale simulation. The shadow system can be a coarsened replica of the fine-scale simulation that evolves concurrently. This means that checkpoints are taken based on the physical state of the system: fewer checkpoints are triggered when the system is quiescent while more are taken when the system undergoes a rapid change. This type of behavior is observed in many systems such as Brusselator and FitzHugh–Nagumo. We illustrate that our framework maintains stable restarts, keeps fine-scale restart errors bounded by shadow errors, and reconstructs the time history with significantly lower error and storage than interpolating fixed-interval snapshots, with low-cost shadow replay and modest online synchronization overhead.

Gong, Qian [ORNL] (ORCID:0000000235704142)↗