Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transducer error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Structural Health Monitoring and Impact Detection Using Neural Networks for Damage Characterization

Detection of damage due to foreign object impact is an important factor in the development of new aerospace vehicles. Acoustic waves generated on impact can be detected using a set of piezoelectric transducers, and the location of impact can be determined by triangulation based on the differences in the arrival time of the waves at each of the sensors. These sensors generate electrical signals in response to mechanical motion resulting from the impact as well as from natural vibrations. Due to electrical noise and mechanical vibration, accurately determining these time differentials can be challenging, and even small measurement inaccuracies can lead to significant errors in the computed damage location. Wavelet transforms are used to analyze the signals at multiple levels of detail, allowing the signals resulting from the impact to be isolated from ambient electromechanical noise. Data extracted from these transformed signals are input to an artificial neural network to aid in identifying the moment of impact from the transformed signals. By distinguishing which of the signal components are resultant from the impact and which are characteristic of noise and normal aerodynamic loads, the time differentials as well as the location of damage can be accurately assessed. The combination of wavelet transformations and neural network processing results in an efficient and accurate approach for passive in-flight detection of foreign object damage.

Ross, Richard W.↗

Advanced Systems for Monitoring Underwater Sounds

The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity data acquired by instrumentation systems other than PAMS. A PAMS is packaged as a battery-powered unit, mated with external sensors, that can operate in the ocean at any depth from 2 m to 1 km. A PAMS includes a pressure housing, a deep-sea battery, a hydrophone (which is one of the mating external sensors), and an external monitor and keyboard box. In addition to acoustic transducers, external sensors can include temperature probes and, potentially, underwater cameras. The pressure housing contains a computer that includes a hard drive, DC-to- DC power converters, a post-amplifier board, a sound card, and a universal serial bus (USB) 4-port hub.

Lane, Michael↗

Application of the Pseudo Wigner-Ville Distribution to the Measurement of the Dispersion of Lamb Modes in Graphite/Epoxy Plates

Acoustic waves propagate in thin plates as guided or Lamb modes. The velocities of these modes are dispersive in that they depend not only on the material elastic properties and density, but also on the frequency. Accurate characterization of Lamb wave dispersion is important in many acoustic based nondestructive evaluation techniques. It is necessary for ultrasonic measurements in thin plates to determine elastic properties and for flaw detection and localization. In acoustic emission (AE) testing, if not taken into account, highly dispersive Lamb mode propagation can lead to large errors in source location. In this study, the pseudo Wigner-Ville distribution (PWVD) was used for measurement of group velocity dispersion of Lamb waves in a unidirectional graphite/epoxy (AS4/3502) laminate. The PWVD is one of a number of transforms which provide a time-frequency representation of a digitized time series. Broad band acoustic waves were generated by a pencil lead fracture (Hsu-Neilsen source) and were detected with broad band ultrasonic transducers. The arrival times for the lowest order symmetric (S(sub 0)) and antisymmetric (A(sub 0)) Lamb modes were determined from measurements of the time at which the respective peak amplitudes occurred in the PWVD. Measurements were made at several source-to-detector distances and a least squares fit used to calculate the velocity. Results are presented for propagation along, and perpendicular to, the fiber direction. Theoretical dispersion curves were also calculated and a comparison between theory and experiment demonstrates good agreement.

Prosser, W. H.↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ~12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Tail Buffet Loads on the F/A-18

The unsteady pressures acting on the vertical tails of a full-scale F/A-18 fighter aircraft were studied to gain a better understanding of tail-buffet loads that frequently occur on fighter aircraft operating at high angles-of-attack. Data for the study were acquired during two test entries in the 80- by 120-Foot Wind Tunnel wherein the aircraft was tested at wind speeds up to 100 knots and at angles-of-attack from 20deg to 40deg. For the purposes of this paper, the primary difference between the two tests is that, during the first wind-tunnel entry, the pressure transducers were more sparsely spaced and covered less of the fin than during the second entry. In addition to a brief description of the spectral analysis methods used for the unsteady aerodynamic pressures and loads, an analysis of the effects of sensor density on estimating integrated loads is presented. It was found that the integrated loads determined from sparse sensor arrays are significantly higher than actual loads. However, a modest increase in the number of sensors can greatly reduce the error and a method for correcting load estimates from sparse sensor arrays is also suggested. The results for the time-averaged, power-spectral analysis are then presented for the tail-fin bending moments. Power spectra are presented for the aircraft at zero sideslip over an angle-of-attack range from 20deg to 40deg and for the aircraft at an angle-of-attack of 30deg over a sideslip range from -16deg to 16deg. Since the aircraft was equipped with a removable leading-edge extension (LEX) fence to reduce tail-buffet loads, the tail-fin bending moment loads are also presented for that configuration. The LEX fence is shown to significantly reduce bending moment loads over a broad range frequencies, for all the aircraft attitudes presented.

Meyn, Larry A.↗

Verification of a three-dimensional resin transfer molding process simulation model

Experimental evidence was obtained to complete the verification of the parameters needed for input to a three-dimensional finite element model simulating the resin flow and cure through an orthotropic fabric preform. The material characterizations completed include resin kinetics and viscosity models, as well as preform permeability and compaction models. The steady-state and advancing front permeability measurement methods are compared. The results indicate that both methods yield similar permeabilities for a plain weave, bi-axial fiberglass fabric. Also, a method to determine principal directions and permeabilities is discussed and results are shown for a multi-axial warp knit preform. The flow of resin through a blade-stiffened preform was modeled and experiments were completed to verify the results. The predicted inlet pressure was approximately 65% of the measured value. A parametric study was performed to explain differences in measured and predicted flow front advancement and inlet pressures. Furthermore, PR-500 epoxy resin/IM7 8HS carbon fabric flat panels were fabricated by the Resin Transfer Molding process. Tests were completed utilizing both perimeter injection and center-port injection as resin inlet boundary conditions. The mold was instrumented with FDEMS sensors, pressure transducers, and thermocouples to monitor the process conditions. Results include a comparison of predicted and measured inlet pressures and flow front position. For the perimeter injection case, the measured inlet pressure and flow front results compared well to the predicted results. The results of the center-port injection case showed that the predicted inlet pressure was approximately 50% of the measured inlet pressure. Also, measured flow front position data did not agree well with the predicted results. Possible reasons for error include fiber deformation at the resin inlet and a lag in FDEMS sensor wet-out due to low mold pressures.

Fingerson, John C.↗

Cryogenic Scan Mechanism for Fourier Transform Spectrometer

A compact and lightweight mechanism has been developed to accurately move a Fourier transform spectrometer (FTS) scan mirror (a cube corner) in a near-linear fashion with near constant speed at cryogenic temperatures. This innovation includes a slide mechanism to restrict motion to one dimension, an actuator to drive the motion, and a linear velocity transducer (LVT) to measure the speed. The cube corner mirror is double-passed in one arm of the FTS; double-passing is required to compensate for optical beam shear resulting from tilting of the moving cube corner. The slide, actuator, and LVT are off-the-shelf components that are capable of cryogenic vacuum operation. The actuator drives the slide for the required travel of 2.5 cm. The LVT measures translation speed. A proportional feedback loop compares the LVT voltage with the set voltage (speed) to derive an error signal to drive the actuator and achieve near constant speed. When the end of the scan is reached, a personal computer reverses the set voltage. The actuator and LVT have no moving parts in contact, and have magnetic properties consistent with cryogenic operation. The unlubricated slide restricts motion to linear travel, using crossed roller bearings consistent with 100-million- stroke operation. The mechanism tilts several arc seconds during transport of the FTS mirror, which would compromise optical fringe efficiency when using a flat mirror. Consequently, a cube corner mirror is used, which converts a tilt into a shear. The sheared beam strikes (at normal incidence) a flat mirror at the end of the FTS arm with the moving mechanism, thereby returning upon itself and compensating for the shear

Brasunas, John C.↗

Real-Time and Online Monitoring of Glucose Contents by Using Molecular Imprinted Polymer-Based IDEs Sensor

A highly sensitive, selective, reversible, and reusable glucose sensor is developed by using molecularly imprinted polymer-based artificial receptors onto interdigital transducer. Sensor receptors were synthesized through bulk imprinting technology by using styrene as monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker, and AIBN as free radical initiator. Topography of the synthesized receptors was investigated by scanning electron microscopy (SEM). Fabricated sensor showed concentration-dependent linear and reversible response with lower limit of detection of 30 ppb and upper limit of detection ~ 500 ppm. Furthermore, newly fabricated sensor is highly selective towards its analyte of interest in the presence of other competing agents, and the regeneration of sensor response has been assessed with the percentage error of less than 2% under the period of 1 year at room temperature and pressure conditions. The reported sensor may have potential technological applications in the field of medical diagnostics, food, and pharmaceutical industry.

60 APPLIED LIFE SCIENCES↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

Simulated measurement of power flow in structures near to simple sources and simple boundaries

Advances in electronics technology along with the advent of low cost multichannel Fast Fourier analyzers have made it practical to use higher order central difference formulas to measure power flow in 1- and 2-D structures. The method discussed uses five point differencing for the spatial derivatives in 1-D and a thirteen point difference pattern for the spatial derivatives in 2-D plates and shells. It is assumed that the measuring transducers are accelerometers. An analytical study of the higher order differencing method and the conventional two accelerometer method was performed as a preliminary to the application of these methods to actual aircraft structures. Some classical problems were analyzed in order to simulate and compare the performance of the two methods under near field measurement conditions. These near field conditions include examples of power flows near simple sources and simple boundaries. The estimates produced by the two methods were compared to the exact solution in each example. Presented are the theory and selected results of the study, which indicate that the bias errors of the two accelerometer method under near field measurement conditions may be much larger than previous studies have suggested.

Mcgary, Michael C.↗

Hopkinson Bar Impact Force Measurement for Application to Development of an Artificial Bird

A test method has been published for measuring forces from bird cadavers and artificial birds to demonstrate equivalency to support the use of artificial birds in aircraft certification testing. The test method involves a large diameter Hopkinson bar as the technique for measuring and comparing forces. The method involves the assumption that a force on one end of the bar results in a one-dimensional plane wave that travels down the bar. To avoid reflected waves from the end of the bar overlapping the input pulse, and due to practical limitations on the length of the bar, strain transducers are located relatively close to the impacted face of the bar, raising questions about the validity of the assumption of one-dimensional wave propagation. In addition, the large diameter of the bar can introduce dispersion effects in the propagated pulse. These must be assessed to determine the impact on the accuracy of impact force measurements and, if significant, dispersion correction techniques must be used. In this study analytical, experimental, and computational methods are used to analyze the wave propagation characteristics for impact forces expected from realistic bird impacts. While wave dispersion and effects of non-concentric impacts are present, the resulting errors are relatively small. For the response we expect to see in bird impacts up to velocities of approximately 300 m/sec the large diameter Hopkinson bar test appears to be an acceptable method for measuring the impact forces and comparing the response of real and proposed artificial birds.

Birdstrike↗

SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-03: Construction of An Ultrasound Guidance Platform for Image-Guided Radiotherapy with the Intent to Treat Transitional Cell Carcinoma

Purpose: Ultrasound (US) is a noninvasive, nonradiographic imaging technique with high spatial and temporal resolution that can be used for localizing soft-tissue structures and tumors in real-time during radiotherapy (inter- and intra-fraction). A detailed methodology integrating 3D-US within RT is presented. This method is easier to adopt into current treatment protocol than current US based systems and reduces user variability for image acquisition, thus eliminating transducer induced changes that limit CT planning system. Methods: We designed an in-house integrated US manipulator and platform to relate CT, 3D-US and linear accelerator coordinate systems. To validate the platform, an agar-based phantom with measured densities and speed-of-sound consistent with tissues surrounding the bladder, was rotated (0–45°) resulting in translations (up to 55mm) relative to the CT and US coordinate systems. After acquiring and integrating CT and US images into the treatment planning system, US-to-US and US-to-CT images were co-registered to re-align the phantom relative to the linear accelerator. Errors in the transformation matrix components were calculate to determine precision of this method under different patient positions. Results: Statistical errors from US-US registrations for different patient orientations ranged from 0.06–1.66mm for x, y, and z translational components, and 0.00–1.05° for rotational components. Statistical errors from US-CT registrations were 0.23–1.18mm for the x, y and z translational components, and 0.08–2.52° for the rotational components. Conclusion: Based on our result, this is consistent with currently used techniques for positioning prostate patients if couch re-positioning is less than a 5 degree rotation. We are now testing this on a dog patient to obtain both inter and intra-fractional positional errors. Additional design considerations include the future use of ultrasound-based functionality (photoacoustics, radioacoustics, Doppler) to monitor blood flow and hypoxia and/or in-vivo dosimetry for applications in other therapeutic techniques, such as hyperthermia, anti-angiogenesis, and particle therapy.

60 APPLIED LIFE SCIENCES↗

Tradeoffs in Prameter Values for Optional Performance

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively, In general, continuous operation of most commercial ultrasonic transducers above 50°C is challenging because of transducer material incompatibility with high temperature. High-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150⁰C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predictions of macro-scale fracture geometries from acoustic emission point cloud data in a hydraulic fracturing experiment

Observations of laboratory fracture testing by means of acoustic emission (AE) can provide a wealth of information regarding the fracturing process and the subsequent damage of the material or structure under load. A method for determining the structure of macro-scale fractures from a point cloud of AE events was developed and tested at the laboratory scale. An unconfined hydraulic fracturing experiment was performed on granite while monitoring acoustic emissions from six piezoelectric transducers on the surfaces of the specimen. The granite specimen dimensions were 30 × 30 × 25 cm 3 . The motivation of the AE analysis was to provide location information for a secondary wellbore placement which intersects the hydraulic fracture to complete a hydraulically connected binary well-hydraulic fracture system. Information gained from the 3D event source locations was used to optimize the location and orientation of secondary production well placement to intersect the induced hydraulic fracture. A direct method was developed to predict the location, orientation and shape of the hydraulic fracture from a dense cloud of AE events. The predicted fracture plane, which was assumed to be planar, was rotated in both the pitch and roll directions, while an average error of AE event distance between the assumed plane and the individual event locations was determined for each rotation iteration, resulting with a predicted fracture plane in the minimum error orientation. Post-test fracture observations were made and digitized in 3D space from coring and slabbing the granite specimen. The actual fracture observations were compared with the predicted fracture structure from AE and showed marked correlation. In conclusion, the simple method of determining macro-scale fracture location, orientation, and extents provided a useful tool for materials that exhibit large and disperse clouds of AE activity where coalesced fracture structure is not apparent.

42 ENGINEERING↗

Acoustic Tomography of the Atmosphere: A Large-Eddy Simulation Sensitivity Study

Accurate measurement of atmospheric turbulent fluctuations is critical for understanding environmental dynamics and improving models in applications such as wind energy. Advanced remote sensing technologies are essential for capturing instantaneous velocity and temperature fluctuations. Acoustic tomography (AT) offers a promising approach that utilizes sound travel times between an array of transducers to reconstruct turbulence fields. This study presents a systematic evaluation of the time-dependent stochastic inversion (TDSI) algorithm for AT using synthetic travel-time measurements derived from large-eddy simulation (LES) fields under both neutral and convective atmospheric boundary-layer conditions. Unlike prior work that relied on field observations or idealized fields, the LES framework provides a ground-truth atmospheric state, enabling quantitative assessment of TDSI retrieval reliability, sensitivity to travel-time measurement noise, and dependence on covariance model parameters and temporal data integration. A detailed sensitivity analysis was conducted to determine the best-fit model parameters, identify the tolerance thresholds for parameter mismatch, and establish a maximum spatial resolution. The TDSI algorithm successfully reconstructed large-scale velocity and temperature fluctuations with root mean square errors ( RMSE s) below 0.35 m/s and 0.12 K, respectively. Spectral analysis established a maximum spatial resolution of approximately 1.4 m, and reconstructions remained robust for travel-time measurement uncertainties up to 0.002 s. These findings provide critical insights into the operational limits of TDSI and inform future applications of AT for atmospheric turbulence characterization and system design.

17 WIND ENERGY↗

Active control of aircraft engine inlet noise using compact sound sources and distributed error sensors

An active noise control system using a compact sound source is effective to reduce aircraft engine duct noise. The fan noise from a turbofan engine is controlled using an adaptive filtered-x LMS algorithm. Single multi channel control systems are used to control the fan blade passage frequency (BPF) tone and the BPF tone and the first harmonic of the BPF tone for a plane wave excitation. A multi channel control system is used to control any spinning mode. The multi channel control system to control both fan tones and a high pressure compressor BPF tone simultaneously. In order to make active control of turbofan inlet noise a viable technology, a compact sound source is employed to generate the control field. This control field sound source consists of an array of identical thin, cylindrically curved panels with an inner radius of curvature corresponding to that of the engine inlet. These panels are flush mounted inside the inlet duct and sealed on all edges to prevent leakage around the panel and to minimize the aerodynamic losses created by the addition of the panels. Each panel is driven by one or more piezoelectric force transducers mounted on the surface of the panel. The response of the panel to excitation is maximized when it is driven at its resonance; therefore, the panel is designed such that its fundamental frequency is near the tone to be canceled, typically 2000-4000 Hz.

Burdisso, Ricardo↗