Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Tomographic optical emission spectroscopy of an atmospheric pressure plasma jet and surface ionization waves on planar and structured surfaces

Here in this paper, an approach for 3D plasma structure diagnostics using tomographic optical emission spectroscopy (Tomo-OES) of a nanosecond pulsed atmospheric pressure plasma jet (APPJ) is presented. In contrast to the well-known Abel inversion, Tomo-OES does not require cylindrical symmetry to recover 3D distributions of plasma light emission. Instead, many 2D angular projections are measured with intensified cameras and the multiplicative algebraic reconstruction technique is used to recover the 3D distribution of light emission. This approach solves the line-of-sight integration problem inherent to optical diagnostics, allowing recovery of localized OES information within the plasma that can be used to better infer plasma parameters within complex plasma structures. Here, Tomo-OES was applied to investigate an APPJ operated with helium in ambient air and impinging on planar and structured dielectric surfaces. Surface charging caused the guided streamer from the APPJ to transition to a surface ionization wave (SIW) that propagated along the surface. The SIW experienced variable geometrical and electrical material properties as it propagated, leading to 3D configurations that were non-symmetric and spatially complex. Light emission from He, N$_2^+$, and N2 were imaged at ten angular projections and the respective time-resolved 3D emission distributions in the plasma were then reconstructed. The spatial resolution of each tomographic reconstruction was 7.4 µm and the temporal resolution was 5 ns, sufficient to observe the guided streamer and the effects of the structured surface on the SIW. Emission from He showed the core of the jet and emission from N$_2^+$ and N2 indicated effects of entrainment of ambient air. Penning ionization of N2 created a ring or outer layer of N$_2^+$ that spatially converged to form the 'plasma bullet' or spatially diverged across a surface as part of a SIW. The SIW entered trenches of size 150 µm, leading to decreases in plasma light emission in regions above the trenches. The plasma light emission was higher in some regions with trenches, possibly due to effects of field enhancement.

plasma interactions with complex surfaces↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted]↗

Longitudinal Phase Space Tomography for the Booster Synchrotron (Abstract Only)

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted, US]↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography had been employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor signal, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted; Fermilab]↗

Exploring the Great Pyramid

For centuries, the pyramids at Giza have been the object of frequent speculation and study. L. Alvarez et al. in 1970 and the ScanPyramids collaboration in 2017 have very successfully implemented HEP detector technology to image the pyramid of Khafre and the Great Pyramid of Khufu, respectively. Numerous questions about Khufu’s structure remain, however. The EGP project aims to undertake a new study of this enigmatic monument’s interior by applying high-resolution tomographic imaging and reconstruction, which will permit a detailed understanding of internal variations in density and may offer insight regarding exactly how Egypt’s largest pyramid was built.

43 PARTICLE ACCELERATORS↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Automatic 3D image registration for nano-resolution chemical mapping using synchrotron spectro-tomography

Nano-resolution synchrotron X-ray spectro-tomography has been demonstrated as a powerful tool for probing the three-dimensional (3D) structural and chemical heterogeneity of a sample. By reconstructing a number of tomographic data sets recorded at different X-ray energy levels, the energy-dependent intensity variation in every given voxel fingerprints the corresponding local chemistry. The resolution and accuracy of this method, however, could be jeopardized by non-ideal experimental conditions, e.g. instability in the hardware system and/or in the sample itself. Herein is presented one such case, in which unanticipated sample deformation severely degrades the data quality. Here, to address this issue, an automatic 3D image registration method is implemented to evaluate and correct this effect. The method allows the redox heterogeneity in partially delithiated Li x Ta 0.3 Mn 0.4 O 2 battery cathode particles to be revealed with significantly improved fidelity.

3D image registration↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗

A novel cosmic filament catalogue from SDSS data

Here, in this work, we present a new catalogue of cosmic filaments obtained from the latest Sloan Digital Sky Survey (SDSS) public data. In order to detect filaments, we implement a version of the Subspace-Constrained Mean-Shift algorithm that is boosted by machine learning techniques. This allows us to detect cosmic filaments as one-dimensional maxima in the galaxy density distribution. Our filament catalogue uses the cosmological sample of SDSS, including Data Release 16, and therefore inherits its sky footprint (aside from small border effects) and redshift coverage. In particular, this means that, taking advantage of the quasar sample, our filament reconstruction covers redshifts up to z = 2.2, making it one of the deepest filament reconstructions to our knowledge. We follow a tomographic approach and slice the galaxy data in 269 shells at different redshift. The reconstruction algorithm is applied to 2D spherical maps. The catalogue provides the position and uncertainty of each detection for each redshift slice. The quality of our detections, which we assess with several metrics, show improvement with respect to previous public catalogues obtained with similar methods. We also detect a highly significant correlation between our filament catalogue and galaxy cluster catalogues built from microwave observations of the Planck Satellite and the Atacama Cosmology Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed Optimization for Nonrigid Nano-Tomography

Resolution level and reconstruction quality in nano-computed tomography (nano-CT) are in part limited by the stability of microscopes, because the magnitude of mechanical vibrations during scanning becomes comparable to the imaging resolution, and the ability of the samples to resist radiation induced deformations during data acquisition. In such cases, there is no incentive in recovering the sample state at different time steps like in time-resolved reconstruction methods, but instead the goal is to retrieve a single reconstruction at the highest possible spatial resolution and without any imaging artifacts. Here we propose a distributed optimization solver for tomographic imaging of samples at the nanoscale. Our approach solves the tomography problem jointly with projection data alignment, nonrigid sample deformation correction, and regularization. Projection data consistency is regulated by dense optical flow estimated by Farneback's algorithm, leading to sharp sample reconstructions with less artifacts. Synthetic data tests show robustness of the method to Poisson and low-frequency background noise. We accelerated the solver on multi-GPU systems and validated the method on three nano-imaging experimental data sets.

97 MATHEMATICS AND COMPUTING↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

Two datasets are better than one: method of double moments for 3D reconstruction in cryo-EM

Cryo-electron microscopy is a powerful imaging technique for reconstructing three-dimensional molecular structures from noisy tomographic projection images of randomly oriented particles. We introduce a new data fusion framework, termed the method of double moments, which reconstructs molecular structures from two instances of the second-order moment of projection images obtained under distinct orientation distributions: one uniform, the other non-uniform and unknown. We prove that these moments generically uniquely determine the underlying structure, up to a global rotation and reflection, and we develop a convex-relaxation-based algorithm that achieves accurate recovery using only second-order statistics. Our results demonstrate the advantage of collecting and modeling multiple datasets under different experimental conditions, illustrating that leveraging dataset diversity can substantially enhance reconstruction quality in computational imaging tasks.

Kam’s method↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗