Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ductility of a continuous fiber reinforced aluminum matrix composite

The transverse properties of an aluminum alloy metal matrix composite reinforced by continuous alumina fibers have been investigated. The composite is subjected to both mechanical and cyclic thermal loading. The ductility can vary by an order of magnitude according to the operating conditions. For high mechanical and low thermal loading the ductility is small, for low mechanical and high thermal loading the ductility is an order of magnitude higher. Experiments on a beam in bending confirm that the ductility is strongly dependent on the loading conditions. The observations suggest a means of utilizing the inherent ductility of the matrix.

Jansson, S.↗

Electromagnetic turbulence simulation of tokamak edge plasma dynamics and divertor heat load during thermal quench

Abstract The edge plasma turbulence and transport dynamics, as well as the divertor power loads during the thermal-quench phase of tokamak disruptions, are numerically investigated with BOUT++’s flux-driven six-field electromagnetic turbulence model. Here, transient yet intense particle and energy sources are applied at the pedestal top to mimic the plasma power drive at the edge induced by a core thermal collapse, which flattens the core temperature profile. Interesting features, such as surging of divertor heat load (up to 50 times) and broadening of heat-flux width (up to four times) on the outer-divertor target plate, are observed in the simulation, in qualitative agreement with experimental observations. The dramatic changes in divertor heat load and width are due to the enhanced plasma turbulence activities inside the separatrix. Two cross-field transport mechanisms, namely, the E × B turbulent convection and the stochastic parallel advection/conduction, are identified to play important roles in this process. First, an elevated edge pressure gradient drives instabilities and subsequent turbulence in the entire pedestal region. The enhanced turbulence not only transports particles and energy radially across the separatrix via the E × B convection, which causes the initial divertor heat-load burst, but it also induces amplified magnetic fluctuation B ˜ . Once themagnetic fluctuation is large enough to break the magnetic flux surface, magnetic flutter effect provides an additional radial transport channel. In the late stage of our simulation, | B ˜ r / B 0 | reaches to 10 −4 level that completely breaks magnetic flux surfaces such that stochastic field lines are directly connecting pedestal top plasma to the divertor target plates or first wall, further contributing to the divertor heat-flux width broadening.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single Crystal Rhombohedral Epitaxy of Sige on Sapphire at 450.Degree. C.-500.Degree. C. Substrate Temperatures

Various embodiments may provide a low temperature (i.e., less than 850° C.) method of Silicon-Germanium (SiGe) on sapphire (Al2O3) (SiGe/sapphire) growth that may produce a single crystal film with less thermal loading effort to the substrate than conventional high temperature (i.e., temperatures above 850° C.) methods. The various embodiments may alleviate the thermal loading requirement of the substrate, which in conventional high temperature (i.e., temperatures above 850° C.) methods had surface temperatures within the range of 850° C.-900° C. The various embodiments may provide a new thermal loading requirement of the sapphire substrate for growing single crystal SiGe on the sapphire substrate in the range of about 450° C. to about 500° C.

Choi, Sang Hyouk↗

The Combinations of Thermal and Load Stresses for the Onset of Permanent Buckling in Plates

A simple and practical method for evaluating the onset of permanent buckling in plates in the presence of combined thermal and compressive load stresses is outlined. A particular application of the method shows reasonable agreement with tests of 17-7 PH stainless-steel square tubes. The results indicate that the compressive load stress which the plate can support at the onset of permanent buckling is substantially reduced as the temperature difference of the plate and adjoining members increases.

LOADS AND STRESSES, STRUCTURAL - COMPRESSION↗

Continued Development of a Precision Cryogenic Dilatometer for the James Webb Space Telescope

As part of the James Webb Space Telescope (JWST) materials working group, a novel cryogenic dilatometer was designed and built at NASA Jet Propulsion Laboratory to help address stringent coefficient of thermal expansion (CTE) knowledge requirements. Previously reported results and error analysis have estimated a CTE measurement accuracy for ULE of 1.7 ppb/K with a 20K thermal load and 0.1 ppb/K with a 280K thermal load. Presented here is a further discussion of the cryogenic dilatometer system and a description of recent work including system modifications and investigations.

thermal strain↗

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon-Carbon Recuperators in Closed-Brayton-Cycle Space Power Systems

The use of carbon-carbon (C-C) recuperators in closed-Brayton-cycle space power conversion systems was assessed. Recuperator performance was forecast based on notional thermodynamic cycle state values for planetary missions. Resulting thermal performance, mass and volume for plate-fin C-C recuperators were estimated and quantitatively compared with values for conventional offset-strip-fin metallic designs. Mass savings of 40-55% were projected for C-C recuperators with effectiveness greater than 0.9 and thermal loads from 25-1400 kWt. The smaller thermal loads corresponded with lower mass savings; however, at least 50% savings were forecast for all loads above 300 kWt. System-related material challenges and compatibility issues were also discussed.

Barrett, Michael J.↗

Characterization of Ternary NiTiPd High-Temperature Shape-Memory Alloys under Load-Biased Thermal Cycling

While NiTiPd alloys have been extensively studied for proposed use in high-temperature shape-memory applications, little is known about the shape-memory response of these materials under stress. Consequently, the isobaric thermal cyclic responses of five (Ni,Pd)49.5Ti50.5 alloys with constant stoichiometry and Pd contents ranging from 15 to 46 at. pct were investigated. From these tests, transformation temperatures, transformation strain (which is proportional to work output), and unrecovered strain per cycle (a measure of dimensional instability) were determined as a function of stress for each alloy. It was found that increasing the Pd content over this range resulted in a linear increase in transformation temperature, as expected. At a given stress level, work output decreased while the amount of unrecovered strain produced during each load-biased thermal cycle increased with increasing Pd content, during the initial thermal cycles. However, continued thermal cycling at constant stress resulted in a saturation of the work output and nearly eliminated further unrecovered strain under certain conditions, resulting in stable behavior amenable to many actuator applications.

Bigelow, Glen S.↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fracture mechanics analysis for various fiber/matrix interface loadings

Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, thereby avoiding frictional effects. A F/M interface toughness test based on this configuration would provide data for K(sub I)/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.

Naik, R. A.↗

Fracture mechanics analysis for various fiber/matrix interface loadings

Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, thereby avoiding frictional effects. An F/M interface toughness test based on this configuration would provide data for K(sub I)/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.

Naik, R. A.↗

Fracture mechanics analysis for various fiber/matrix interface loadings

Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, theory avoiding fractional effects. A F/M interface toughness test based on this configuration would provide data for K(sub I/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.

Naik, Rajiv A.↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Experimental Study of the Influence of Speed and Load on Thermal Behavior of High-Speed Helical Gear Trains

An experimental effort has been conducted on an aerospace-quality helical gear train to investigate the thermal behavior of the gear system as speed, load, and lubricant flow rate were varied. Temperature test data from a helical gear train at varying speeds and loads (to 5000 hp and 15000 rpm) was collected using thermocouple rakes and axial arrays. The instrumentation was able to capture the radial and axial expelled lubricant-air environment (fling-off lubricant) that is expelled during the gear meshing process. Effects of operational characteristics are presented.

Handschuh, R.↗

Carbon-Carbon Recuperators in Closed-Brayton-Cycle Space Power Systems

The feasibility of using carbon-carbon (C-C) recuperators in conceptual closed-Brayton-cycle space power conversion systems was assessed. Recuperator performance expectations were forecast based on notional thermodynamic cycle state values for potential planetary missions. Resulting thermal performance, mass and volume for plate-fin C-C recuperators were estimated and quantitatively compared with values for conventional offset-strip-fin metallic designs. Mass savings of 30 to 60 percent were projected for C-C recuperators with effectiveness greater than 0.9 and thermal loads from 25 to 1400 kWt. The smaller thermal loads corresponded with lower mass savings; however, 60 percent savings were forecast for all loads above 300 kWt. System-related material challenges and compatibility issues were also discussed.

Barrett, Michael J.↗

Average power effects in parametric oscillators and amplifiers

Average power effects relative to the operation of parametric oscillators and amplifiers have been calculated. Temperature gradients have been calculated for both radial and longitudinal heat extraction. In many instances, the thermal load on a parametric oscillator is higher than the thermal load on a parametric amplifier with the same pump power. Having one or both these wavelengths resonant increases the chances that a generated photon will be absorbed by the nonlinear crystal. Temperature profiles and thermal diffusion time constants have been calculated for Gaussian beams, given the heat-deposition rate. With radical heat extraction the temperature profile can be expressed in a power series or approximated by a Gaussian distribution function.

Barnes, Norman P.↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.

Allgood, Daniel C.↗