Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Photogrammetrically Measured Distortions of Composite Structure Microwave Reflectors at Approximately 90 K

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a fall 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (better than 0.3 deg.) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back composite Gregorian telescopes supported on a composite truss structure to focus the microwave signals into 10 differential microwave receivers. Proper position and shape of the telescope reflectors at the operating temperature of approximately 90 K is a critical element to ensuring mission success. We describe the methods and analysis used to validate the in-flight position and shape predictions for the reflectors based on photogrammetric (PG) metrology data taken under vacuum with the reflectors at approximately 90 K. Contour maps showing reflector distortion analytical extrapolations were generated. The resulting reflector distortion data are shown to be crucial to the analytical assessment of the MAP instrument's microwave system in-flight performance.

Mule, Peter↗

Cryogenic Thermal Distortion Performance Characterization for the JWST ISIM Structure

The James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Structure is a precision optical metering structure for the JWST science instruments. Optomechanical performance requirements place stringent limits on the allowable thermal distortion of the metering structure between ambient and cryogenic operating temperature (~35 K). This paper focuses on thermal distortion testing and successful verification of performance requirements for the flight ISIM Structure. The ISIM Structure Cryoset Test was completed in Spring 2010 at NASA Goddard Space Flight Center in the Space Environment Simulator Chamber. During the test, the ISIM Structure was thermal cycled twice between ambient and cryogenic (~35 K) temperatures. Photogrammetry was used to measure the Structure in the ambient and cryogenic states for each cycle to assess both cooldown thermal distortion and repeatability. This paper will provide details on the post-processing of the metrology datasets completed to compare measurements with performance requirements.

Johnston, John D.↗

In-plane thermal conductivity and the applicability of the Wiedemann–Franz law in dilute AlCu thin films

The Wiedemann–Franz (WF) law correlates heat and charge transport in metals. However, the validity of this correlation remains an open-ended question, especially in the context of inelastic scattering at room temperature. To address this gap in knowledge, we perform independent measurements of the in-plane thermal and electrical conductivities across four AlCu (0.5% Cu) films [thickness (⁠h⁠) ≈ 174, 98, 53, and 24 nm] using optical pump–probe metrologies and four-point probe techniques, respectively. For in-plane thermal conductivity measurements, we utilize time-domain thermoreflectance, in both concentric and beam-offset configurations, and the time-resolved magneto-optic Kerr effect. Our results show that the WF law overpredicts the thermal conductivity by at least ∼10% in all films, thus demonstrating modest deviations in predicted thermal conductivity when applying the WF law to dilute AlCu films. Using infrared variable angle spectroscopic ellipsometry, we demonstrate increased electron scattering rates in the thinnest film (⁠⁠h⁠ ≈ 24 nm), indicating electron-boundary scattering drives the reduction in in-plane thermal conductivity. Furthermore, this is generally an elastic scattering process, which is supported by our thermal conductivity measurements and analysis.

Electrical conductivity↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications

The design and initial demonstration of a laser pump module (LPM) incorporating single-mode, grating-stabilized 808-nm diode lasers and a low-loss, high-port-count optical combiner are completed. The purpose of the developed LPM is to reliably pump an Nd:YAG crystal in the laser head (LH), which serves as the optical metrology source for SIMLite mission. Using the narrow-linewidth, single-mode laser diodes enables placement of the pump power near Nd adsorption peak, which enhances pumping efficiency. Grating stabilization allows for stable pump spectra as diode operating temperature and bias current change. The low-loss, high-port-count optical combiner enables efficient combining of tens of pumps. Overall, the module supports 5+ years of continuous operation at 2 W of pump power with reliability approaching 100 percent. The LPM consists of a laser diode farm (LDF) and a pump beam combiner (PBC). An array of 807- to 808-nm fiber-pigtailed laser diodes makes up the LDF. A Bragg grating in each 5- m core single-mode (SM) fiber pigtail acts to stabilize the lasing spectra over a range of diode operating conditions. These commercially available single-mode laser diodes can deliver up to 150 mW of optical power. The outputs from the multiple pumps in the LDF are routed to the PBC, which is a 37-input by 1-output all-fiber device. The input ports consist of 5- m core SM fiber, while the output port consists of 105- m core, 0.15 NA (numerical aperture) multi-mode (MM) fiber. The combiner is fabricated by fusing the 37 input fibers while simultaneously tapering the fused region. At the completion of this process, the MM fiber is spliced to the end of the adiabatic taper, and, for protection, the combiner is sheathed by a capillary tube. A compact and robust metal housing was designed and fabricated to protect the PBC during space deployment.

Erlig, Herman↗

Structural Benchmark Creep Testing for Microcast MarM-247 Advanced Stirling Convertor E2 Heater Head Test Article SN18

This report provides test methodology details and qualitative results for the first structural benchmark creep test of an Advanced Stirling Convertor (ASC) heater head of ASC-E2 design heritage. The test article was recovered from a flight-like Microcast MarM-247 heater head specimen previously used in helium permeability testing. The test article was utilized for benchmark creep test rig preparation, wall thickness and diametral laser scan hardware metrological developments, and induction heater custom coil experiments. In addition, a benchmark creep test was performed, terminated after one week when through-thickness cracks propagated at thermocouple weld locations. Following this, it was used to develop a unique temperature measurement methodology using contact thermocouples, thereby enabling future benchmark testing to be performed without the use of conventional welded thermocouples, proven problematic for the alloy. This report includes an overview of heater head structural benchmark creep testing, the origin of this particular test article, test configuration developments accomplished using the test article, creep predictions for its benchmark creep test, qualitative structural benchmark creep test results, and a short summary.

life (durability)↗

Design of a Thermal Testbed for Metrology of Active Antennas

NASA mission requirements have driven an increased interest in active phased array antennas (APAA) for space-based user communication terminals. Recent advancements in 5G technology have driven down the cost of APAA development and manufacturing all while providing a technology solution that covers many existing Ka-Band satellite communication spectrum bands. While these developments have provided ample opportunities to leverage new chips and arrays for use in space, there is also a need to evaluate these antennas in a relevant environment. Active arrays, as designed for use in 5G, require thermal management to avoid damage to the device as well as to maintain performance. Measured performance under various thermal conditions is essential both for understanding overall APAA performance and ensuring operation is within required tolerances. To address these measurement needs, the SmallSat Ka-band Operations User Terminal (SKOUT) project at the NASA Glenn Research Center (GRC) developed a test environment that combines traditional antenna and communication system metrology with a conduction cooling/heating thermal control system to simulate the space thermal environment. This paper will address the metrologysystem design and performance specifications as well as test article setup and operation. Tests that are typically performed at ambient temperature can now be performed over the typical temperature range of a Low Earth Orbit (LEO) mission. These tests include error vector magnitude (EVM), gain to noise temperature (G/T), antenna patterns, and non-linear characterization. The paper will cover the configuration for each test and provide results from a recent test campaign. Results illustrate the importance of higher fidelity environmental testing when evaluating the performance of an APAA.

active phased array↗

Qualification and Selection of Flight Diode Lasers for Space Applications

The reliability and lifetime of laser diodes is critical to space missions. The Nuclear Spectroscopic Telescope Array (NuSTAR) mission includes a metrology system that is based upon laser diodes. An operational test facility has been developed to qualify and select, by mission standards, laser diodes that will survive the intended space environment and mission lifetime. The facility is situated in an electrostatic discharge (ESD) certified clean-room and consist of an enclosed temperature-controlled stage that can accommodate up to 20 laser diodes. The facility is designed to characterize a single laser diode, in addition to conducting laser lifetime testing on up to 20 laser diodes simultaneously. A standard laser current driver is used to drive a single laser diode. Laser diode current, voltage, power, and wavelength are measured for each laser diode, and a method of selecting the most adequate laser diodes for space deployment is implemented. The method consists of creating histograms of laser threshold currents, powers at a designated current, and wavelengths at designated power. From these histograms, the laser diodes that illustrate a performance that is outside the normal are rejected and the remaining lasers are considered spaceborne candidates. To perform laser lifetime testing, the facility is equipped with 20 custom laser drivers that were designed and built by California Institute of Technology specifically to drive NuSTAR metrology lasers. The laser drivers can be operated in constant-current mode or alternating-current mode. Situated inside the enclosure, in front of the laser diodes, are 20 power-meter heads to record laser power throughout the duration of lifetime testing. Prior to connecting a laser diode to the current source for characterization and lifetime testing, a background program is initiated to collect current, voltage, and resistance. This backstage data collection enables the operational test facility to have full laser diode traceablity.

Liebe, Carl C.↗

Development and Testing of a High-Precision Position and Attitude Measuring System for a Space Mechanism

This paper describes a high-precision optical metrology system - a unique ground test equipment which was designed and implemented for simultaneous precise contactless measurements of 6 degrees-of-freedom (3 translational + 3 rotational) of a space mechanism end-effector [1] in a thermally controlled ISO 5 clean environment. The developed contactless method reconstructs both position and attitude of the specimen from three cross-sections measured by 2D distance sensors [2]. The cleanliness is preserved by the hermetic test chamber filled with high purity nitrogen. The specimen's temperature is controlled by the thermostat [7]. The developed method excludes errors caused by the thermal deformations and manufacturing inaccuracies of the test jig. Tests and simulations show that the measurement accuracy of an object absolute position is of 20 micron in in-plane measurement (XY) and about 50 micron out of plane (Z). The typical absolute attitude is determined with an accuracy better than 3 arcmin in rotation around X and Y and better than 10 arcmin in Z. The metrology system is able to determine relative position and movement with an accuracy one order of magnitude lower than the absolute accuracy. Typical relative displacement measurement accuracies are better than 1 micron in X and Y and about 2 micron in Z. Finally, the relative rotation can be measured with accuracy better than 20 arcsec in any direction.

Khanenya, Nikolay↗

NASA Tech Briefs, September 2011

Topics covered include: Fused Reality for Enhanced Flight Test Capabilities; Thermography to Inspect Insulation of Large Cryogenic Tanks; Crush Test Abuse Stand; Test Generator for MATLAB Simulations; Dynamic Monitoring of Cleanroom Fallout Using an Air Particle Counter; Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency; Positively Verifying Mating of Previously Unverifiable Flight Connectors; Radiation-Tolerant Intelligent Memory Stack - RTIMS; Ultra-Low-Dropout Linear Regulator; Excitation of a Parallel Plate Waveguide by an Array of Rectangular Waveguides; FPGA for Power Control of MSL Avionics; UAVSAR Active Electronically Scanned Array; Lockout/Tagout (LOTO) Simulator; Silicon Carbide Mounts for Fabry-Perot Interferometers; Measuring the In-Process Figure, Final Prescription, and System Alignment of Large; Optics and Segmented Mirrors Using Lidar Metrology; Fiber-Reinforced Reactive Nano-Epoxy Composites; Polymerization Initiated at the Sidewalls of Carbon Nanotubes; Metal-Matrix/Hollow-Ceramic-Sphere Composites; Piezoelectrically Enhanced Photocathodes; Iridium-Doped Ruthenium Oxide Catalyst for Oxygen Evolution; Improved Mo-Re VPS Alloys for High-Temperature Uses; Data Service Provider Cost Estimation Tool; Hybrid Power Management-Based Vehicle Architecture; Force Limit System; Levitated Duct Fan (LDF) Aircraft Auxiliary Generator; Compact, Two-Sided Structural Cold Plate Configuration; AN Fitting Reconditioning Tool; Active Response Gravity Offload System; Method and Apparatus for Forming Nanodroplets; Rapid Detection of the Varicella Zoster Virus in Saliva; Improved Devices for Collecting Sweat for Chemical Analysis; Phase-Controlled Magnetic Mirror for Wavefront Correction; and Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics.

Source record↗

Two-frequency sub-Doppler spectroscopy of the caesium D{sub 1} line in various configurations of counterpropagating laser beams

Sub-Doppler resonances in caesium vapours are studied in a laser field produced by counterpropagating two-frequency light beams with mutually orthogonal linear polarisations. The beams are in resonance with optical transitions in the D{sub 1} line, the frequency difference of the field spectral components being equal to the hyperfine ground-state splitting in the Cs atom (∼9.2 GHz). It has already been shown that in this configuration, the hypercontrast effect can be observed for sub-Doppler resonances, which makes this configuration promising for the employment in new-generation miniature optical frequency standards. In the present work, two different two-frequency configurations are compared with each other and with the single-frequency configuration widely used in practice for observing saturated absorption resonances. The parameters of nonlinear resonances are measured at various temperatures of caesium vapours and at different optical field intensities. The results of the investigations performed make it possible to find an optimal two-frequency scheme for exciting nonlinear resonances and to estimate a potential of the scheme for its applications in quantum metrology. (laser spectroscopy of atoms)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hybrid coupler for directing quantum light emission with high radiative Purcell enhancement to a dielectric metasurface lens

Quantum photonic technologies such as quantum sensing, metrology, and simulation could be transformatively enabled by the availability of integrated single photon sources with high radiative rates and photon collection efficiencies. We address these challenges for quantum emitters formed from color center defect sites such as those in hexagonal boron nitride, which are promising candidates as single photon sources due to their bright, stable, polarized, and room temperature emission. We report design of a nanophotonic coupler from color center quantum emitters to a dielectric metasurface lens. The coupler is comprised of a hybrid plasmonic–dielectric resonator that achieves a large radiative Purcell enhancement and partial control of far-field radiation. We report radiative Purcell factors up to 285 and photon collection efficiencies up to 89% for a lossless metasurface, applying a continuous hyperboloidal phase-front. Our hybrid plasmonic–dielectric coupler interfacing two nanophotonic elements is a compound optical element, analogous to those found in microscope objective lenses, which combine multiple optical functions into a single component for improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gimbal bearing design considerations and friction control

The design considerations of bearing selection, bearing fits, bearing installation, and thermal control are discussed for a gimbal with a high stiffness, low friction torque requirement. Tradeoffs between a quad set of small diameter spread apart or a large diameter bearing pair resulted in a cleaner, lighter, stiffer unit with the latter selection. Bearing fits were designed to eliminate clearances with tolerances of .00127 mm 00005 in) on the bearing shafts and housings. The problems in metrology are discussed and a perferred technique for measurement of small cross-section bearings described. A technique for installation to assure proper seating of the bearing is offered. Where transient thermal conditions are involved, a method of controlling bearing friction by active control of bearing temperature gradients including the use of bearing unload test curves is described.

Kramer, N. R.↗

Metrological and Spectral Characterization of the Aspera Flight Optics

Aspera is a NASA's Astrophysics Pioneers mission, led by the University of Arizona. The aim of this mission is to study the presence of hot gasses (T=10^5-10^6 K) in the circumgalactic medium (CGM) and how the flow of these gasses affects galactic formation. One key enabling technology in the Aspera optical system is the use of more efficient UV-reflective optical coatings particularly at around 103.2 nm where the O VI emission line is located . In order to meet radiometric effective area requirements, the Goddard Space Flight Center (GSFC) code 551 Optics Branch applied Al (aluminum) + eLiF (enhanced lithium fluoride) on these optics, where the Al+LiF is annealed at elevated temperature (~250˚C) after the deposition and thus providing an improved version of the Al+LiF used in FUSE . Furthermore, these optics are encapsulated with a thin film of atomic layer deposited MgF2 at the Jet Propulsion Laboratory for enhanced durability . The efficiency and durability of these coatings depends on the quality of the optical surface in terms of cleanliness and roughness. Roughness increases the scatter off the coating and reduces the specular reflectance, and surface contaminants can accommodate moisture and other contaminants, increase scattering, and are weak points in the coating that may affect adhesion and subsequently the longevity of these coatings. Extensive optical metrology is necessary to minimize and quantify the impact of surface roughness and contaminants on optical surfaces. In this proceeding we report the inspection procedure implemented for Aspera optics at GSFC, from initial receiving of the optics to post-coating. Inspection includes Atomic Force Microscopy (AFM), Scanning White Light Interferometry (SWILI), Dark Field Microscopy (DFM), Phase Shifting Interferometry (PSI), and Vacuum ultraviolet (VUV) spectroscopy. Combinations of these techniques are used to inspect flight optics at each of the following steps: i) as-received, pre-cleaning inspection, ii) pre-coating, post-cleaning inspection, and iii) post-coating inspection. The evolution of roughness and other surface inspections such as contaminants are compared between each step to quantify the effect each step has on the flight optics. The final far ultraviolet (FUV) spectral performance of witness samples coated with the flight optics are presented.

Far Ultraviolet (FUV)↗

Capability Improvements at Marshall Space Flight Center's X-Ray and Cryogenic Facility

The X-Ray & Cryogenic Facility (XRCF) at Marshall Space Flight Center is the world’s largest x-ray optic calibration facility and NASA’s premier cryogenic optical test facility. Built specifically to calibrate the Chandra telescope, the facility contributed to several other x-ray missions until 2005 when it became dedicated to normal incidence optical testing at cryogenic temperatures. Recently the facility’s x-ray test capability has been returned to service and updated. New beam monitors, focal plane detectors, and test article and instrument positioning systems have been added. The x-ray data acquisition system has been updated. A real-time position monitoring metrology system is being developed that will enable calibration of large diameter optics via partial illumination in a diverging beam. The newly expanded x-ray test capabilities of the facility will be discussed.

XRCF↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗