Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Nonparametric test of consistency between cosmological models and multiband CMB measurements

We present a novel approach to test the consistency of the cosmological models with multiband CMB data using a nonparametric approach. In our analysis we calibrate the REACT (Risk Estimation and Adaptation after Coordinate Transformation) confidence levels associated with distances in function space (confidence distances) based on the Monte Carlo simulations in order to test the consistency of an assumed cosmological model with observation. To show the applicability of our algorithm, we confront Planck 2013 temperature data with concordance model of cosmology considering two different Planck spectra combination. In order to have an accurate quantitative statistical measure to compare between the data and the theoretical expectations, we calibrate REACT confidence distances and perform a bias control using many realizations of the data. Our results in this work using Planck 2013 temperature data put the best fit ΛCDM model at 95% (∼ 2σ) confidence distance from the center of the nonparametric confidence set while repeating the analysis excluding the Planck 217 × 217 GHz spectrum data, the best fit ΛCDM model shifts to 70% (∼ 1σ) confidence distance. The most prominent features in the data deviating from the best fit ΛCDM model seems to be at low multipoles 18 < ℓ < 26 at greater than 2σ, ℓ ∼ 750 at ∼1 to 2σ and ℓ ∼ 1800 at greater than 2σ level. Excluding the 217×217 GHz spectrum the feature at ℓ ∼ 1800 becomes substantially less significance at ∼1 to 2σ confidence level. Results of our analysis based on the new approach we propose in this work are in agreement with other analysis done using alternative methods.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of Cosmological Parameters Determined from CMB Temperature Power Spectra from the South Pole Telescope and the Planck Satellite

The Planck cosmic microwave background temperature data are best fit with a Lambda CDM model that mildly contradicts constraints from other cosmological probes. The South Pole Telescope (SPT) 2540 deg(2) SPT-SZ survey offers measurements on sub-degree angular scales (multipoles 650 <= l <= 2500) with sufficient precision to use as an independent check of the Planck data. Here we build on the recent joint analysis of the SPT-SZ and Planck data in Hou et al. by comparing Lambda CDM parameter estimates using the temperature power spectrum from both data sets in the SPT-SZ survey region. We also restrict the multipole range used in parameter fitting to focus on modes measured well by both SPT and Planck, thereby greatly reducing sample variance as a driver of parameter differences and creating a stringent test for systematic errors. We find no evidence of systematic errors from these tests. When we expand the maximum multipole of SPT data used, we see low-significance shifts in the angular scale of the sound horizon and the physical baryon and cold dark matter densities, with a resulting trend to higher Hubble constant. When we compare SPT and Planck data on the SPT-SZ sky patch to Planck full-sky data but keep the multipole range restricted, we find differences in the parameters n(s) and A(s)e(-2 tau). We perform further checks, investigating instrumental effects and modeling assumptions, and we find no evidence that the effects investigated are responsible for any of the parameter shifts. Taken together, these tests reveal no evidence for systematic errors in SPT or Planck data in the overlapping sky coverage and multipole range and at most weak evidence for a breakdown of Lambda CDM or systematic errors influencing either the Planck data outside the SPT-SZ survey area or the SPT data at l > 2000.

Aylor, K.↗

Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code

The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previous VTR calculation reports, the undocumented limitation in SAS v5.4 does not allow the user to activate the CFD coupling option during restart calculations. Since the analysts were unaware of this limitation, prior SAS-CFD simulation results for the protected station blackout (PSBO) transient were erroneous. Root-cause analysis was performed to determine the cause of this undocumented limitation in SAS v5.4, the SAS software was updated in a new patch, and the SAS-CFD simulations were repeated with this patched software. The results of the SAS-CFD simulations documented in this report show that the software patch does address the cited issue, and that the patched software indeed supports the activation of the CFD coupling model in restart calculations. The SAS development team will determine the schedule for implementing the patch in an official software release. This report documents updated SAS-CFD simulations of the PSBO transient response in the VTR. The hot pool is modeled with the CFD code STAR-CCM+, which is coupled at the flow boundaries to the SAS model of the primary heat transport system. SAS computes the mass flow rate and temperature at each core subassembly outlet, the thermal insulation cavity bypass, and the IHX inlet windows. CFD in turn computes the absolute pressure and temperature at each of these boundaries. The SAS code will ignore the temperature data at flow boundaries where flow is directed into the hot pool, i.e., at the core subassembly outlets unless flow reversal occurs. Similarly, CFD will ignore temperature data at boundaries where the flow is directed out of the hot pool, i.e., at the IHX inlets except under flow reversal. The focus of this work is to ensure that the SAS software patch addresses the undocumented limitation described in prior VTR calculation reports, rather than the accurate assessment of thermal stratification in the VTR during protected transients. This motivates the development of a new, simplified CFD model with a coarser mesh to accelerate the testing process. The updated model, and simplifying assumptions, are documented in this report. In future work, the thermal stratification assessment should be performed in more detail. The simplified CFD model can be improved by performing grid convergence studies sensitivity studies of turbulence parameters (e.g., Prandtl number, turbulence production and dissipation parameters) on temperature distributions and thermal stratification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fourier analysis of conductive heat transfer for glazed roofing materials

For low-rise buildings, roof is the most exposed surface to solar radiation. The main mode of heat transfer from outdoor via the roof is conduction. The rate of heat transfer and the thermal impact is dependent on the thermophysical properties of roofing materials. Thus, it is important to analyze the heat distribution for the various types of roofing materials. The objectives of this paper are to obtain the Fourier series for the conductive heat transfer for two types of glazed roofing materials, namely polycarbonate and polyfilled, and also to determine the relationship between the ambient temperature and the conductive heat transfer for these materials. Ambient and surface temperature data were collected from an empirical field investigation in the campus of Universiti Teknologi MARA Shah Alam. The roofing materials were installed on free-standing structures in natural ventilation. Since the temperature data are generally periodic, Fourier series and numerical harmonic analysis are applied. Based on the 24-point harmonic analysis, the eleventh order harmonics is found to generate an adequate Fourier series expansion for both glazed roofing materials. In addition, there exists a linear relationship between the ambient temperature and the conductive heat transfer for both glazed roofing materials. Based on the gradient of the graphs, lower heat transfer is indicated through polyfilled. Thus polyfilled would have a lower thermal impact compared to polycarbonate.

42 ENGINEERING↗

Estimating soil thermal inertia profiles from the passive equilibration of a temperature probe: Supporting data and code

This dataset contains measurements of soil thermal properties and organic layer thickness at three field sites on the Seward Peninsula near Nome, Alaska, USA. Code is also provided for estimation of soil thermal properties from temperature data, including a forward heat transfer mode, a library of simulated temperature data, and an inversion scheme to retrieve thermal properties from temperature measurements (Lamb et al., 2025). This dataset and code is published in support of the manuscript “Estimating Soil Thermal Inertia Profiles from the Passive Equilibration of a Temperature Probe” by Lamb et al., 2025, in which an experimental thermal measurements technique is developed. The dataset contains measurements of soil thermal properties and organic layer thickness obtained with an industry standard thermal properties analyzer and direct observations, as well as data generated using the experimental technique to estimate thermal properties and soil structure from temperature observations. All data is reported in .csv format, and all code is written in Python 3.7 using standard packages. This research was performed as a part of the NGEE Arctic project, which aims to advance model predictions of arctic carbon cycle responses to a changing climate over the 21st Century.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Data Driven Temperature Control of Heat Exchangers

The following poster presents a couple of approaches for temperature control at heat exchanger’s exit. One of the approaches is based on using n-step ahead neural network while the other approach utilizes a combination of control + learning module for temperature control. Designing robust controllers for typical heat exchangers is very challenging primarily because of complexities associated with the synthesis of dynamics of industrial heat exchangers. Even if a dynamics model is synthesized, the accuracy of it would be called into question as there can be lot of unmodeled system dynamics and random noise in input parameters. In many situations, the degree of uncertainty in the model of system being controlled limits the utility of optimal control design. Controller can be manually tuned on the field but it is very difficult to determine manual adjustments that result in overall improvement. These practical challenges call for learning based approaches for temperature control that would result in optimal heat exchanger performance. We utilize the existing mathematical model for air-water system synthesized by Underwood and Crawford for testing our algorithms. Underwood and Crawford developed a model of heating coil by fitting a second-order non-linear equations to measurements of air and water temperature and flow rates obtained from the actual coil. The uncertainties in the model include air and water inlet temperatures and air-flow rate. These uncertainties are modeled as random variables that are sampled from a uniform distribution. The control variable is the water flow rate which is controlled for regulating the air-outlet temperature. Neural networks are frequently used in various literatures for learning time-series. We propose a modified version of neural networks known as n-step ahead neural network that take the state variables and output at time t as input to successfully predict output at time t+n. The variable n is a hyper-parameter which can be optimized based on performance constraints. The n-step ahead neural network was then trained on training data generated from experimental model to high training accuracies. This trained model performed appreciably in its objective to regulate outlet temperature of a heat exchanger. The second approach uses a combination of control and learning module for temperature regulation. The control module used is a proportional controller while the learning module used is steady state neural network. The steady state neural network is used to learn the controller output as a function of random variables and temperature set-point. The proportional controller is then used to compensate for transient behavior of linearized system around various operating points. The algorithm works effectively for temperature regulation as neural network captures the non-linear input-output behavior of closed loop system leaving proportional controller to compensate for steady state errors of a linearized plant. The proposed algorithm’s performances were evaluated against the performance of a PI controller. Further, the robustness of the algorithms were also studied in great detail under small perturbations around tuned parameters of the proposed algorithms.

Sundar, Sreenath↗

Prospects and Limitations of Predicting Fuel Ignition Properties from Low-Temperature Speciation Data

Using chemical kinetic modeling and statistical analysis, we investigate the possibility of correlating key chemical “markers”–typically small molecules–formed during very lean (φ ~ 0.001) oxidation experiments with near-stoichiometric (φ ~ 1) fuel ignition properties. One goal of this work is to evaluate the feasibility of designing a fuel-screening platform, based on small laboratory reactors that operate at low temperatures and use minimal fuel volume. Buras et al. [Combust. Flame2020,216, 472–484] have shown that convolutional neural net (CNN) fitting can be used to correlate first-stage ignition delay times (IDTs) with OH/HO2 measurements during very lean oxidation in low-T flow reactors with better than factor-of-2 accuracy. In this work, we test the limits of applying this correlation-based approach to predict the low-temperature heat release (LTHR) and total IDT, including the sensitivity of total IDT to the equivalence ratio, φ. We demonstrate that first-stage IDT can be reliably correlated with very lean oxidation measurements using compressed sensing (CS), which is simpler to implement than CNN fitting. LTHR can also be predicted via CS analysis, although the correlation quality is somewhat lower than for first-stage IDT. In contrast, the accuracy of total IDT prediction at φ = 1 is significantly lower (within a factor of 4 or worse). Furthermore, these results can be rationalized by the fact that the first-stage IDT and LTHR are primarily determined by low-temperature chemistry, whereas total IDT depends on low-, intermediate-, and high-temperature chemistry. Oxidation reactions are most important at low temperatures, and therefore, measurements of universal molecular markers of oxidation do not capture the full chemical complexity required to accurately predict the total IDT even at a single equivalence ratio. As a result, we find that φ-sensitivity of ignition delay cannot be predicted at all using solely correlation with lean low-T chemical speciation measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overheating in Hot Water- and Steam-Heated Multifamily Buildings

Apartment temperature data have been collected from the archives of companies that provide energy management systems (EMS) to multifamily buildings in the Northeast U.S. The data have been analyzed from more than 100 apartments in eighteen buildings where EMS systems were already installed to quantify the degree of overheating. This research attempts to answer the question, 'What is the magnitude of apartment overheating in multifamily buildings with central hot water or steam heat?' This report provides valuable information to researchers, utility program managers and building owners interested in controlling heating energy waste and improving resident comfort. Apartment temperature data were analyzed for deviation from a 70 degrees F desired setpoint and for variation by heating system type, apartment floor level and ambient conditions. The data shows that overheating is significant in these multifamily buildings with both hot water and steam heating systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proline: Mother Nature;s cryoprotectant applied to protein crystallography

L-Proline is one of Mother Nature's cryoprotectants. Plants and yeast accumulate proline under freeze-induced stress and the use of proline in the cryopreservation of biological samples is well established. Here, it is shown that L-proline is also a useful cryoprotectant for protein crystallography. Proline was used to prepare crystals of lysozyme, xylose isomerase, histidine acid phosphatase and 1-pyrroline-5-carboxylate dehydrogenase for low-temperature data collection. The crystallization solutions in these test cases included the commonly used precipitants ammonium sulfate, sodium chloride and polyethylene glycol and spanned the pH range 4.6-8.5. Thus, proline is compatible with typical protein-crystallization formulations. The proline concentration needed for cryoprotection of these crystals is in the range 2.0-3.0 M. Complete data sets were collected from the proline-protected crystals. Proline performed as well as traditional cryoprotectants based on the diffraction resolution and data-quality statistics. The structures were refined to assess the binding of proline to these proteins. As observed with traditional cryoprotectants such as glycerol and ethylene glycol, the electron-density maps clearly showed the presence of proline molecules bound to the protein. In two cases, histidine acid phosphatase and 1-pyrroline-5-carboxylate dehydrogenase, proline binds in the active site. It is concluded that L-proline is an effective cryoprotectant for protein crystallography.

59 BASIC BIOLOGICAL SCIENCES↗

Constraints on Cosmological Parameters from the Angular Power Spectrum of a Combined 2500 deg 2 SPT-SZ and Planck Gravitational Lensing Map

Here, we report constraints on cosmological parameters from the angular power spectrum of a cosmic microwave background (CMB) gravitational lensing potential map created using temperature data from 2500 deg$^2$ of South Pole Telescope (SPT) data supplemented with data from Planck in the same sky region, with the statistical power in the combined map primarily from the SPT data. We fit the corresponding lensing angular power spectrum to a model including cold dark matter and a cosmological constant ($\Lambda$CDM), and to models with single-parameter extensions to $\Lambda$CDM. We find constraints that are comparable to and consistent with constraints found using the full-sky Planck CMB lensing data. Specifically, we find $\sigma_8 \Omega_{\rm m}^{0.25}=0.598 \pm 0.024$ from the lensing data alone with relatively weak priors placed on the other $\Lambda$CDM parameters. In combination with primary CMB data from Planck, we explore single-parameter extensions to the $\Lambda$CDM model. We find $\Omega_k = -0.012^{+0.021}_{-0.023}$ or $M_{\nu}< 0.70$eV both at 95% confidence, all in good agreement with results that include the lensing potential as measured by Planck over the full sky. We include two independent free parameters that scale the effect of lensing on the CMB: $A_{L}$, which scales the lensing power spectrum in both the lens reconstruction power and in the smearing of the acoustic peaks, and $A^{\phi \phi}$, which scales only the amplitude of the CMB lensing reconstruction power spectrum. We find $A^{\phi \phi} \times A_{L} =1.01 \pm 0.08$ for the lensing map made from combined SPT and Planck temperature data, indicating that the amount of lensing is in excellent agreement with what is expected from the observed CMB angular power spectrum when not including the information from smearing of the acoustic peaks.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Thermal Assessment and In-Situ Monitoring of Insulated Gate Bipolar Transistors in Power Electronic Modules: Preprint

Insulated gate bipolar transistor (IGBT) power modules are devices commonly used for switching of high voltages and currents. Usage and environmental conditions can cause these power modules to degrade over time, and this gradual process may eventually lead to catastrophic failure of the device. This degradation process may cause some early performance symptoms related to the state of health of the power module, making it possible to detect reliability degradation of the IGBT module. Testing can be used to accelerate this process, permitting a rapid determination of whether specific declines in device reliability can be characterized. In this study, thermal cycling was conducted on multiple power modules simultaneously in order to assess the effect of thermal cycling on the degradation of the power module. In-situ monitoring of temperature was performed from inside each power module using high temperature thermocouples. Device imaging and characterization was performed along with temperature data analysis, to assess failure modes and mechanisms within the power modules. While the experiment was aimed to assess the potential damage effects of thermal cycling on die attach, results indicated that wirebond degradation was the life limiting failure mechanism.

33 ADVANCED PROPULSION SYSTEMS↗

Non-perturbative measurement of cross-field thermal diffusivity reduction at the O-point of 2/1 neoclassical tearing mode islands in the DIII-D tokamak

Neoclassical tearing modes (NTMs) often lead to the decrease of plasma performance and can lead to disruptions, which makes them a major impediment in the development of operating scenarios in present toroidal fusion devices. Recent gyrokinetic simulations predict a decrease of plasma turbulence and cross-field transport at the O-point of the islands, which in turn affects the NTM dynamics. In this paper, a heat transport model of magnetic islands employing spatially non-uniform cross-field thermal diffusivity (χ{sub ⊥}) is presented. This model is used to derive χ{sub ⊥} at the O-point from electron temperature data measured across 2/1 NTM islands in DIII-D. It was found that χ{sub ⊥} at the O-point is 1 to 2 orders of magnitude smaller than the background plasma transport, in qualitative agreement with gyrokinetic predictions. As the anomalously large values of χ{sub ⊥} are often attributed to turbulence driven transport, the reduction of the O-point χ{sub ⊥} is consistent with turbulence reduction found in recent experiments. Finally, the implication of reduced χ{sub ⊥} at the O-point on NTM dynamics was investigated using the modified Rutherford equation that predicts a significant effect of reduced χ{sub ⊥} at the O-point on NTM saturation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Projecting spatiotemporally explicit effects of climate change on stream temperature: A model comparison and implications for coldwater fishes

Conservation planners and resource managers seek information about how the availability and locations of cold-water habitats will change in the future and how these predictions vary among models. In this work, we used a physical process-based model to demonstrate the implications of climate change for streamflow and water temperature in two watersheds with distinctive flow regimes: the Snoqualmie watershed (WA) and Siletz watershed (OR), USA. Our model incorporated a downscaled ensemble of global climate model outputs and was calibrated with in situ and remotely sensed water temperatures. Furthermore, we compared predictions from our processed-based model to those from a publicly available and widely used statistical model. The process-based model projected greater changes in summer maximum water temperatures for the mixed-rain-snow Snoqualmie watershed than for the rain-dominated Siletz watershed as a result of the near-complete loss of winter snowpack and significant reduction in summer flow in the Snoqualmie watershed expected by the 2080s. Both models projected generally similar future spatial patterns of maximum water temperature in the two rivers, with cool reaches distributed farther upstream and fewer in number. However, the process-based model projected higher spatial heterogeneity in water temperature due to our spatially explicit simulation of streamflow and because we calibrated the model with spatially continuous remotely sensed water temperature data. We used stream temperature projections to assess the vulnerability of Pacific salmon and trout to changes in the spatial distribution of cold-water habitats during August by the 2080s. Results suggest that salmonids may have fewer summertime cold-water habitats in both watersheds. Projected stream warming may further limit particular species and life stages, especially in the Snoqualmie watershed. Our comparison of models highlights the importance of considering what might be gained by using a process-based model for evaluating and prioritizing management actions that mitigate climate impacts on cold-water habitats for stream fishes.

54 ENVIRONMENTAL SCIENCES↗

Results from sudden loss of vacuum on scaled superconducting radio frequency cryomodule experiment

Superconducting radio frequency (SRF) cavities for particle accelerators are at risk of failure due to sudden loss of vacuum (SLV) adjacent to liquid helium (LHe) spaces. To better understand this failure mode and its associated risks an experiment is designed to test the longitudinal effects of SLV within the beam tube of a scaled SRF cryomodule that has considerable length relative to beam tube cross section. The scaled cryomodule consists of six individual SRF cavities each roughly 350 mm long, initially cooled to 2 K by a superfluid helium bath and a beam tube pumped to vacuum. A fast-acting solenoid valve is used to simulate SLV on the beam tube, from which point it takes over 3 s for the beam tube pressure to equalize with atmosphere, and 30 s for the helium space to reach the relief pressure of 4 bara. A SLV longitudinal effect in the beam tube is evident in both pressure and temperature data, but interestingly the temperatures responds more quickly to SLV than do the pressures. It takes 500 ms (roughly 100 ms per cavity) for the far end of the 2 m long beam tube to respond to a pressure increase compared to 300 ms for temperature (approximately 50 ms per cavity). The paper expands upon these and other results to better understand the longitudinal effect for SRF cryomodules due to SLV.

43 PARTICLE ACCELERATORS↗

Review of Prior Commercial Building Energy Efficiency Retrofit Evaluation: A Report to Snohomish Public Utilities District

Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced by real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗