Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tablet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Microtron MT 25 as a source of neutrons

The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a {sup 10}B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space.

43 PARTICLE ACCELERATORS↗

Frequency-dependent ferroelectric behavior of BaMn3Ti4O14.25 at room temperature

We report the activation field and selective frequency-dependent ferroelectric behavior of BaMn3Ti4O14.25 (BMT-134) at room temperature. BMT-134, a recently discovered multiferroic complex oxide, exhibits antiferromagnetic and ferroelectric behavior and belongs to the hollandite crystal class. The microstructure can be manipulated through processing conditions to prepare a nanocrystalline textured tablet. We measured polarization-electric field (P-E) hysteresis loops and strain-electric field butterfly loops as a function of frequency in order to investigate the AC dynamics of domain switching and strain behavior. Under an electric field loading condition, a clear hysteresis loop of the electric field-displacement curve is obtained at 50 Hz, indicating that room temperature ferroelectricity is attainable under the right processing conditions. When the frequency is increased to 500 Hz, the coercive field also increases, until the frequency reaches 5 kHz, at which point the electric field versus electric displacement becomes linear indicating the limit of domain switching at high frequency.

Hossain, Muhammad E.↗

The optical properties and photocatalytic activity of CdS-ZnS-TiO{sub 2}/Graphite for isopropanol degradation under visible light irradiation

This research prepared a photocatalyst tablet of CdS-ZnS-TiO{sub 2} on a graphite substrate. The synthesis was conducted through chemical bath deposition method. The graphite substrate used was a waste graphite rod from primary batteries. The aims of this research are studying the crystal structure, the optical properties and the photocatalytic activity of the prepared material. The photocatalytic activity was determined through isopropanol degradation. The result shows that the TiO{sub 2}/Graphite provide direct transition gap energy at 2.91 eV and an indirect transition gap energy at 3.21 eV. Deposition of CdS-ZnS changed the direct transition gap energy to 3.01 eV and the indirect transition gap energy to 3.22 eV. Isopropanol degradation with the prepared catalyst produced new peaks at 223-224 nm and 265-266 nm confirming the production of acetone. The degradation follows first order with rate constant of 2.4 × 10{sup −2} min{sup −1}.

36 MATERIALS SCIENCE↗

Structural and optical properties of Ta{sub 2}O{sub 5}:Eu{sup 3+}: Mg{sup 2+} or Ca{sup 2+} phosphor prepared by molten salt method

Ta{sub 2}O{sub 5}:Eu{sup 3+}: Mg{sup 2+} or Ca{sup 2+} phosphor materials were prepared by molten salt method using KCl as flux. The X-ray diffraction (XRD) patterns illustrated that the well crystallized Ta{sub 2}O{sub 5}:Eu{sup 3+}: Mg{sup 2+} or Ca{sup 2+} were formed in the presence of flux under reduced temperature (800 °C) in contrast to conventional solid state method (1200-1500 °C). Scanning electron microscope (SEM) images indicate the achievement of well dispersed particles (hexagonal tablet and rod-like structures). Meanwhile, the photo-luminescent studies demonstrated that Ta{sub 2}O{sub 5} is an efficient host to sensitize europium red emissions. The addition of Mg{sup 2+} or Ca{sup 2+} as co-dopant enhanced the luminescent intensity of Ta{sub 2}O{sub 5}: Eu{sup 3+} compound.

36 MATERIALS SCIENCE↗

The agile alert system for gamma-ray transients

In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping the three-dimensional “x-shaped structure” in models of the Galactic bulge

Numerical simulations have shown that the X-shaped structure in the Milky Way bulge can naturally arise from bar instability and buckling instability. To understand the influence of buckling amplitude on the morphology of the X-shape, we analyze three self-consistent numerical simulations of barred galaxies with different buckling amplitudes (strong, intermediate, and weak). We derive the three-dimensional density using an adaptive kernel smoothing technique. The face-on isodensity surfaces are all elliptical, while in the edge-on view, the morphology of buckled bars transitions with increasing radius from a central boxy core to a peanut bulge and then to an extended, thin bar. Based on these isodensity surfaces at different density levels, we find no clear evidence for a well-defined structure shaped like the letter X. The X-shaped structure is more peanut-like, the visual perception of which is probably enhanced by the pinched inner concave isodensity contours. The peanut bulge can reproduce qualitatively the observed bimodal distributions that were used as evidence for the discovery of the X-shape. The central boxy core is shaped like an oblong tablet, extending ∼500 pc above and below the Galactic plane (|b|∼4{sup ∘}). From the solar perspective, lines of sight passing through the central boxy core do not show bimodal distributions. This generally agrees with the observations that double peaks merge at |b| ∼ 4°–5° from the Galactic plane, indicating the presence of a possibly similar structure in the Galactic bulge.

79 ASTRONOMY AND ASTROPHYSICS↗

Extra-light gamma-ray imager for safeguards and homeland security

Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)

42 ENGINEERING↗

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

Evaluation of a lithium formate EPR dosimetry system for dose measurements around {sup 192}Ir brachytherapy sources

A dosimetry system using lithium formate monohydrate (HCO{sub 2}Li{center_dot}H{sub 2}O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical {sup 192}Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm{sup 3} were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. {sup 192}Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within {+-}2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR {sup 192}Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-213-04: Application of Depth Sensing and 3D-Printing Technique for Total Body Irradiation (TBI) Patient Measurement and Treatment Planning

Purpose: To develop and validate an innovative method of using depth sensing cameras and 3D printing techniques for Total Body Irradiation (TBI) treatment planning and compensator fabrication. Methods: A tablet with motion tracking cameras and integrated depth sensing was used to scan a RANDOTM phantom arranged in a TBI treatment booth to detect and store the 3D surface in a point cloud (PC) format. The accuracy of the detected surface was evaluated by comparison to extracted measurements from CT scan images. The thickness, source to surface distance and off-axis distance of the phantom at different body section was measured for TBI treatment planning. A 2D map containing a detailed compensator design was calculated to achieve uniform dose distribution throughout the phantom. The compensator was fabricated using a 3D printer, silicone molding and tungsten powder. In vivo dosimetry measurements were performed using optically stimulated luminescent detectors (OSLDs). Results: The whole scan of the anthropomorphic phantom took approximately 30 seconds. The mean error for thickness measurements at each section of phantom compare to CT was 0.44 ± 0.268 cm. These errors resulted in approximately 2% dose error calculation and 0.4 mm tungsten thickness deviation for the compensator design. The accuracy of 3D compensator printing was within 0.2 mm. In vivo measurements for an end-to-end test showed the overall dose difference was within 3%. Conclusion: Motion cameras and depth sensing techniques proved to be an accurate and efficient tool for TBI patient measurement and treatment planning. 3D printing technique improved the efficiency and accuracy of the compensator production and ensured a more accurate treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-11: A Cloud Based CT and LINAC QA Data Management System

Purpose: The current status quo of QA data management consists of a mixture of paper-based forms and spreadsheets for recording the results of daily, monthly, and yearly QA tests for both CT scanners and LINACs. Unfortunately, such systems suffer from a host of problems as, (1) records can be easily lost or destroyed, (2) data is difficult to access — one must physically hunt down records, (3) poor or no means of historical data analysis, and (4) no remote monitoring of machine performance off-site. To address these issues, a cloud based QA data management system was developed and implemented. Methods: A responsive tablet interface that optimizes clinic workflow with an easy-to-navigate interface accessible from any web browser was implemented in HTML/javascript/CSS to allow user mobility when entering QA data. Automated image QA was performed using a phantom QA kit developed in Python that is applicable to any phantom and is currently being used with the Gammex ACR, Las Vegas, Leeds, and Catphan phantoms for performing automated CT, MV, kV, and CBCT QAs, respectively. A Python based resource management system was used to distribute and manage intensive CPU tasks such as QA phantom image analysis or LaTeX-to-PDF QA report generation to independent process threads or different servers such that website performance is not affected. Results: To date the cloud QA system has performed approximately 185 QA procedures. Approximately 200 QA parameters are being actively tracked by the system on a monthly basis. Electronic access to historical QA parameter information was successful in proactively identifying a Linac CBCT scanner’s performance degradation. Conclusion: A fully comprehensive cloud based QA data management system was successfully implemented for the first time. Potential machine performance issues were proactively identified that would have been otherwise missed by a paper or spreadsheet based QA system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-80: A Mobile Application for Intra-Operative Electron Radiotherapy Treatment Planning

Purpose: Intraoperative electron radiotherapy (IORT) poses a unique set of challenges for treatment planning. Planning must be performed in a busy operating room environment over a short timeframe often with little advance knowledge of the treatment depth or applicator size. Furthermore, IORT accelerators can have a large number of possible applicators, requiring extensive databooks that must be searched for the appropriate dosimetric parameters. The goal of this work is to develop a software tool to assist in the planning process that is suited to the challenges faced in the IORT environment. Methods: We developed a mobile application using HTML5 and Javascript that can be deployed to tablet devices suitable for use in the operating room. The user selects the desired treatment parameters cone diameter, bevel angle, and energy (a total of 141 datasets) and desired bolus. The application generates an interactive display that allows the user to dynamically select points on the depth-dose curve and to visualize the shape of the corresponding isodose contours. The user can indicate a prescription isodose line or depth. The software performs a monitor unit calculation and generates a PDF report. Results: We present our application, which is now used routinely in our IORT practice. It has been employed successfully in over 23 cases. The interactivity of the isodose distributions was found to be of particular use to physicians who are less-frequent IORT users, as well as for the education of residents and trainees. Conclusion: This software has served as a useful tool in IORT planning, and demonstrates the need for treatment planning tools that are designed for the specialized challenges encountered in IORT. This software is the subject of a license agreement with the IntraOp Medical Corporation. This software is the subject of a license agreement between Massachusetts General Hospital / Partners Healthcare and the IntraOp Medical Corporation. CLW is consulting on software development with the IntraOp Medical Corporation.

60 APPLIED LIFE SCIENCES↗

Sirepo for Synchrotron Radiation Workshop

Sirepo is an open source framework for cloud computing. The graphical user interface (GUI) for Sirepo, also known as the client, executes in any HTML5 compliant web browser on any computing platform, including tablets. The client is built in JavaScript, making use of the following open source libraries: Bootstrap, which is fundamental for cross-platform web applications; AngularJS, which provides a model–view–controller (MVC) architecture and GUI components; and D3.js, which provides interactive plots and data-driven transformations. The Sirepo server is built on the following Python technologies: Flask, which is a lightweight framework for web development; Jinja, which is a secure and widely used templating language; and Werkzeug, a utility library that is compliant with the WSGI standard. We use Nginx as the HTTP server and proxy, which provides a scalable event-driven architecture. The physics codes supported by Sirepo execute inside a Docker container. One of the codes supported by Sirepo is the Synchrotron Radiation Workshop (SRW). SRW computes synchrotron radiation from relativistic electrons in arbitrary magnetic fields and propagates the radiation wavefronts through optical beamlines. SRW is open source and is primarily supported by Dr. Oleg Chubar of NSLS-II at Brookhaven National Laboratory.

Nagler, Robert↗

Sirepo - Warp

Sirepo is an open source framework for cloud computing. The graphical user interface (GUI) for Sirepo, also known as the client, executes in any HTML5 compliant web browser on any computing platform, including tablets. The client is built in JavaScript, making use of the following open source libraries: Bootstrap, which is fundamental for cross-platform web applications; AngularJS, which provides a model–view–controller (MVC) architecture and GUI components; and D3.js, which provides interactive plots and data-driven transformations. The Sirepo server is built on the following Python technologies: Flask, which is a lightweight framework for web development; Jin-ja, which is a secure and widely used templating language; and Werkzeug, a utility library that is compliant with the WSGI standard. We use Nginx as the HTTP server and proxy, which provides a scalable event-driven architecture. The physics codes supported by Sirepo execute inside a Docker container. One of the codes supported by Sirepo is Warp. Warp is a particle-in-cell (PIC) code de-signed to simulate high-intensity charged particle beams and plasmas in both the electrostatic and electromagnetic regimes, with a wide variety of integrated physics models and diagnostics. At pre-sent, Sirepo supports a small subset of Warp’s capabilities. Warp is open source and is part of the Berkeley Lab Accelerator Simulation Toolkit.

Nagler, Robert↗

Automated Auditing Tool for Retrofit Building Projects [SWR-11-07]

Building energy auditors regularly use notepads, physical forms, or simple spreadsheets to inventory energy consuming devices in buildings and audit overall performance. Mobile computing devices such as smart phones or tablet computers with camera inputs may be used to automatically capture relevant information and format audit input in a way that streamlines work flows and reduces the likelihood of error. As an example. an auditor could walk through a space holding a mobile device, which automatically identifies and appliances, windows, etc. This information would automatically be added to a mobile database associated with the building for later integration with a larger building audit database. The user experience would require little or no manual input, and could integrate with tools to automate used to automate data collection for building energy modeling.

Parker, Andrew↗

NMDC Field Notes Phone Application (NMDC Field Notes) v1.0

This software is for an application, designed for phones and/or tablets, to assist microbiome researchers collecting samples in the field to also collect metadata in a standardized and systematic way. The type of samples covered would be e.g. soil sample from a forest, sediment sample from a lake, or water sample in the ocean. The app allows users to collect sample information and metadata in an easy and intuitive way, and connects to the NMDC submission portal (https://data.microbiomedata.org/submission/home) a website from where users can review the samples they collected and add more information if necessary.

Kalita, Patrick↗