Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Magnitude error bounds for sampled-data frequency response obtained from the truncation of an infinite series, and compensator improvement program

The frequency response method of analyzing control system performance is discussed, and the difficulty of obtaining the sampled frequency response of the continuous system is considered. An upper bound magnitude error equation is obtained which yields reasonable estimates of the actual error. Finalization of the compensator improvement program is also reported, and the program was used to design compensators for Saturn 5/S1-C dry workshop and Saturn 5/S1-C Skylab.

Mitchell, J. R.↗

Aircraft System Identification from Multisine Inputs and Frequency Responses

A frequency-domain approach is described for estimating parameters, such as stability and control derivatives, in aircraft flight dynamic models from measured input and output data. The approach uses orthogonal phase-optimized multisines for moving the aircraft control effectors, Fourier analysis for computing multiple-input multiple-output frequency responses, and a maximum likelihood estimator called frequency response error (FRE) for determining values and uncertainties for the model parameters. The approach is demonstrated using flight test data for two subscale airplanes: the T-2 generic transport model and the X-56A aeroelastic demonstrator. Results and comparisons with the output-error method indicated that the approach produced accurate estimates of stability and control derivatives and their uncertainties from flight test data.

Grauer, Jared A.↗

Linear Array Photodiode and Data Acquisition System Development for Multi-Point Line FLDI Measurements

The continuous development and advancement of multi-point line focused laser differential interferometry (FLDI) instruments requires larger numbers of acquisition channels to make more finely spatially resolved measurements of high-frequency flow fluctuations. No current off-the-shelf system exists for these line FLDI measurements, and so a single unified system consisting of a linear array photodiode, required electronics, and a data acquisition system has been developed to enhance the measurement resolution, both spatially and temporally. A printed circuit board was developed on which the linear array photodiode is mounted for inclusion into an existing FLDI system, and amplifier breakout boards incorporate electronics to condition the signal for the data acquisition system while retaining the necessary high frequency response. The data acquisition system uses a National Instruments chassis and multiple oscilloscope modules, with a specially-designed LabVIEW user interface for laboratory and wind tunnel setup, calibration, and testing. Details regarding the development of the linear array photodiode system and the data acquisition system are provided, and systematic testing of all components is presented, culminating in a test of the system integrated into an existing line FLDI system for measurements of a turbulent jet.

Joshua M Weisberger↗

Operability of a Power System with Synchronous Condensers and Grid-Following Inverters

Growing shares of inverter-based resources gener-ally correlate with a reduction in inertia as synchronous genera-tors are displaced. Along the path to high shares of inverter-based resources, in particular with only conventional grid-following inverter controls, a proffered solution is the use of synchronous condensers as a source of inertia to maintain the frequency-power balance relationship. An outstanding question is whether only grid-following inverters and synchronous condensers yield a viable power system; i.e., all frequency response is derived from inverters. A validated electromagnetic transient model of the Maui system, with many nonlinear elements such as load-shedding, line tripping, and inverter ride through criteria disabled, is used to investigate the stability of such a system. Two types of perturbations were applied, a 15% generation loss and a fault event, and it was found that the system remains stable.

grid-following inverters↗

Quantification and prediction of error in MIMO tests

Dynamic testing of systems is most realistic of real-world conditions when multiple input and multiple output (MIMO) techniques are used. To replicate measured environmental conditions, a series of desired outputs (responses) on the system must be realized by inverting the frequency response functions (FRF) matrix for input estimation. System identification is dependent on the number of inputs and outputs, which affect the type of solutions. In input estimation, the auto spectra of the determined inputs are affected by both the auto spectra and cross spectra of the desired outputs. This research evaluates errors and investigates two sources in an experimental setting. The first significant error source is test-to-test variability in FRFs from system identification tests, quantified by magnitude variability from long-duration tests. The second significant error source is the realization of time histories from frequency domain inputs. The spectral content of the realized random process deviates from the desired content and is also quantified. The structure is a linear three-story frame fixed at the base; two inputs are provided uniaxially with the use of suspended electrodynamic shakers. The proposed model for error sources was found to be effective in predicting errors in a SISO (single-input single-output) and a square (2-input 2-output) MIMO test.

Yousef, Odey↗

Aeroelastic Analysis of the NASA/ARMY/MIT Active Twist Rotor

Aeroelastic modeling procedures used in the design of a piezoelectric controllable twist helicopter rotor wind tunnel model are described. Two aeroelastic analysis methods developed for active twist rotor studies, and used in the design of the model blade, are described in this paper. The first procedure uses a simple flap-torsion dynamic representation of the active twist blade, and is intended for rapid and efficient control law and design optimization studies. The second technique employs a commercially available comprehensive rotor analysis package, and is used for more detailed analytical studies. Analytical predictions of hovering flight twist actuation frequency responses are presented for both techniques. Forward flight fixed system nP vibration suppression capabilities of the model active twist rotor system are also presented. Frequency responses predicted using both analytical procedures agree qualitatively for all design cases considered, with best correlation for cases where uniform blade properties are assumed.

Wilkie, W. Keats↗

Frequency Control and Disturbance Containment Using Grid-Forming Embedded Storage Networks

The paper presents a distributed approach for operating a network of inverter-based energy storage resources embedded in a bulk power system. Departing from their traditional role of steady-state reserves, the storage assets in the network are utilized as frequency-responsive resources shaping system dynamics. The power electronics converter systems interfacing the storage resources are equipped with local controllers designed to respond under transient disturbances. To this end, a safety-constrained distributed control strategy is explored. The paper compares the performance of converter-interfaced grid-forming and grid-following storage networks for fast frequency control and disturbance containment/localization. Sensitivity studies are performed to study the impact of storage size, steady-state dispatch, and controller design on dynamic performance. The findings are presented through case studies with results from the IEEE test systems.

Chatterjee, Kaustav (ORCID:0000000153273860)↗

Stability conditions derived from spectral theory - Discrete systems with periodic feedback.

By use of the spectral theory of linear operators, necessary and sufficient conditions are derived for the stability of a class of discrete time feedback systems with a periodically time-varying feedback gain. These conditions involve a Nyquist plot for an equivalent time-invariant system which may be determined from the frequency response function of the system under consideration. In the special case of a scalar-input scalar-output system, these conditions may be given in a particularly simple form.

Davis, J. H.↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

A high-performance constant-temperature hot-wire anemometer

A high-performance constant-temperature hot-wire anemometer has been designed based on a system theory analysis that can be extended to arbitrary order. A motivating factor behind the design was to achieve the highest possible frequency response while ensuring overall system stability. Based on these considerations, the design of the circuit and the selection of components is discussed in depth. Basic operating instructions are included in an operator's guide. The analysis is used to identify operating modes, observed in all anemometers, that are misleading in the sense that the operator can be deceived by interpreting an erroneous frequency response. Unlike other anemometers, this instrument provides front panel access to all the circuit parameters which affect system stability and frequency response. Instructions are given on how to identify and avoid these rather subtle and undesirable operating modes by appropriate adjustment of the controls. Details, such as fabrication drawings and a parts list, are provided to enable others to construct the instrument.

Watmuff, Jonathan H.↗

Effects of nonlinear damping in flexible space structures

The classical Krylov-Bogoliubov "averaging" technique is used to study a class of nonlinear damping models, for which the damping force is proportional to the product of positive integer or fractional power of absolute values of displacement and that of velocity. The results are compared with linear viscous damping models. The amplitude decrement of free vibration for a single mode system with nonlinear models depends not only on damping ratio, but also on the initial amplitude, the time to measure the response, frequency of the system, and the powers of displacement and velocity. For the distributed system, the action of nonlinear damping is found to reduce energy of the system as well as to pass energy to higher modes. Experimental evidence such as in Spacecraft Control Laboratory Experiment seems to support the need for nonlinear models.

Hu, Anren↗

Preliminary results from a subsonic high angle-of-attack flush airdata sensing (HI-FADS) system: Design, calibration, and flight test evaluation

A nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was installed and flight-tested on the F-18 high alpha research flight vehicle. The system is a matrix of 25 pressure orifices in concentric circles on the nose of the vehicle. The orifices determine angles of attack and sideslip, Mach number, and pressure altitude. Pressure was transmitted from the orifices to an electronically scanned pressure module by lines of pneumatic tubing. The HI-FADS system was calibrated and demonstrated using dutch roll flight maneuvers covering large Mach, angle-of-attack, and sideslip ranges. Reference airdata for system calibration were generated by a minimum variance estimation technique blending measurements from two wingtip airdata booms with inertial velocities, aircraft angular rates and attitudes, precision radar tracking, and meteorological analyses. The pressure orifice calibration was based on identifying empirical adjustments to modified Newtonian flow on a hemisphere. Calibration results are presented. Flight test results used all 25 orifices or used a subset of 9 orifices. Under moderate maneuvering conditions, the HI-FADS system gave excellent results over the entire subsonic Mach number range up to 55 deg angle of attack. The internal pneumatic frequency response of the system is accurate to beyond 10 Hz. Aerodynamic lags in the aircraft flow field caused some performance degradation during heavy maneuvering.

Whitmore, Stephen A.↗

Preliminary results from a subsonic high-angle-of-attack flush airdata sensing (HI-FADS) system - Design, calibration, algorithm development, and flight test evaluation

A nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was installed and flight-tested on the F-18 high alpha research vehicle. This paper discusses the airdata algorithm development and composite results expressed as airdata parameter estimates and describes the HI-FADS system hardware, calibration techniques, and algorithm development. An independent empirical verification was performed over a large portion of the subsonic flight envelope. Test points were obtained for Mach numbers from 0.15 to 0.94 and angles of attack from -8.0 to 55.0 deg. Angles of sideslip ranged from -15.0 to 15.0 deg, and test altitudes ranged from 18,000 to 40,000 ft. The HI-FADS system gave excellent results over the entire subsonic Mach number range up to 55 deg angle of attack. The internal pneumatic frequency response of the system is accurate to beyond 10 Hz.

Whitmore, Stephen A.↗

On-orbit Modulation Transfer Function (MTF) Measurements for IKONOS and QuickBird

Point Spread Function is a method of evaluation the spatial resolution of an imaging system. It is also a measure of the spread of a single point of light. Modulation Transfer Function (MTF) is a measure of the spatial frequency response. It is often calculated from th point spread function (PSF). System response at the Nyquist frequency (or 0.5 cycle/pixel) is often used as a figure of merit

Helde, Dennis↗

Ride quality flight testing

The ride quality experienced by passengers is a function of airframe rigid-body, elastic dynamic responses, autopilot, and stability augmentation system control inputs. A frequency response method has been developed to select sinusoidal elevator input time histories yielding vertical load factor distributions, within a given limit, as a function of fuselage station. The numerical technique is illustrated by applying two-degree-of-freedom short-period and first symmetric mode equations of motion to a B-1 aircraft at Mach 0.85 during sea level flight conditions.

Swaim, R. L.↗