Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synthetic diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Synthetic aromatic kerosene property prediction improvements with isomer specific characterization via GCxGC and vacuum ultraviolet spectroscopy

This research explores an advanced method of fuel composition determination and builds upon typical hydrocarbon group type analyses performed with two-dimensional gas chromatography (GCxGC). In this study, structural information of individual species within Virent’s Synthetic Aromatic Kerosene (SAK) is identified by vacuum ultraviolet (VUV) spectroscopy. By mass, 71.3% of the components elute within six peaks of the chromatogram, from which 12 unique species are identified through a novel deconvolution method. Overall, the identification of 93.6%m across 26 structural isomers is made by the methods described in this work. With 93.6%m ascribed to specific isomers, the precision of fuel property predictions improves dramatically. For example, the absolute error of the viscosity prediction is reduced by 90% because of this advancement in diagnostic capability, and its 95-percentile confidence interval (precision only) is reduced by 93%. Additionally, the properties of SAK, blended with hydro processed esters fatty acids (HEFA), are demonstrated to have blended properties consistent with conventional jet fuel.

10 SYNTHETIC FUELS↗

Design of a multi-detector, single line-of-sight, time-of-flight system to measure time-resolved neutron energy spectra

In the dynamic environment of burning, thermonuclear deuterium–tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ~10 12 longer than inertial confinement fusion (ICF) plasmas. In this work, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV n DT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UrbanPop: A spatial microsimulation framework for exploring demographic influences on human dynamics

Ensuring the social equity of planning measures in social systems requires an understanding of human dynamics, particularly how individual relationships, activities, and interactions intersect with individual needs. Spatial microsimulation models (SMSMs) support planning for human security goals by representing human dynamics through realistic, georeferenced synthetic populations, that a) provide a complete representation of social systems while b) also protecting individual privacy. In this paper, we present UrbanPop, an open and reproducible SMSM framework for analysis of human dynamics with high spatial, temporal, and demographic resolution. UrbanPop creates synthetic populations of demographically detailed worker and student agents, positioning them first at probable nighttime locations (home), then moving them to probable daytime locations (work/school). Summary aggregations of these populations match the granular detail available at the census block group level in the American Community Survey Summary File (SF), providing realistic approximations of the actual population. UrbanPop users can select particular demographic traits important in their application, resulting in a highly tailored agent population. We first lay out UrbanPop's baseline methodology, including population synthesis, activity modeling, and diagnostics, then demonstrate these capabilities by developing case studies of shifting population distributions and high-risk populations in Knox County, TN during the global COVID-19 pandemic.

60 APPLIED LIFE SCIENCES↗

Distortions in charged-particle images of laser direct-drive inertial confinement fusion implosions

Energetic charged particles generated by inertial confinement fusion (ICF) implosions encode information about the spatial morphology of the hotspot and dense fuel during the time of peak fusion reactions. The knock-on deuteron imager (KoDI) was developed at the Omega Laser Facility to image these particles in order to diagnose low-mode asymmetries in the hotspot and dense fuel layer of cryogenic deuterium–tritium ICF implosions. However, the images collected are distorted in several ways that prevent reconstruction of the deuteron source. In this paper, we describe these distortions and a series of attempts to mitigate or compensate for them. We present several potential mechanisms for the distortions, including a new model for scattering of charged particles in filamentary electric or magnetic fields surrounding the implosion. Particle-tracing is used to create synthetic KoDI data based on the filamentary field model that reproduces the main experimentally observed image distortions. We conclude that the filamentary scattering model best matches the observed image distortions. Finally, we discuss potential impacts of filamentary fields on other charged-particle diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical inference of anomalous thermal transport with uncertainty quantification for interpretive 2D SOL models

The critical task of inferring anomalous cross-field transport coefficients is addressed in simulations of boundary plasmas with fluid models. A workflow for parameter inference in the UEDGE fluid code is developed using Bayesian optimization with parallelized sampling and integrated uncertainty quantification. In this workflow, transport coefficients are inferred by maximizing their posterior probability distribution, which is generally multidimensional and non-Gaussian. Uncertainty quantification is integrated throughout the optimization within the Bayesian framework that combines diagnostic uncertainties and model limitations. As a concrete example, we infer the anomalous electron thermal diffusivity $\chi_\perp$ from an interpretive 2D model describing electron heat transport in the conduction-limited region with radiative power loss. The workflow is first benchmarked against synthetic data and then tested on H-, L-, and I-mode discharges to match their midplane temperature and divertor heat flux profiles. We demonstrate that the workflow efficiently infers diffusivity and its associated uncertainty, generating 2D profiles that match 1D measurements. Future efforts will focus on incorporating more complicated fluid models and analyzing transport coefficients inferred from a large database of experimental results.

Bayesian optimization↗

Revisiting the Kinematics of the Cylinder Test

The cylinder expansion experiment is a well-established performance test for condensed explosives that is utilized routinely to determine pressure-energy-volume relationships for detonation products. The modern cylinder test employs optical interferometric techniques to measure velocity, as opposed to older realizations where streak cameras were commonplace. Despite their widespread use, questions sometimes remain as to what kind of data the velocity diagnostics in a cylinder test provide along with how to interpret such measurements and relate them to physical quantities of interest. Here in this study, equations are derived that fully describe the kinematics of the cylinder wall during expansion. These equations are then applied to experimental as well as synthetic data generated via a hydrodynamic simulation in order to verify the mathematical framework developed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validating the simulation of beam-ion charge exchange in MAST Upgrade

Abstract Simulation of the impact of charge-exchange (CX) reactions on beam ions in the Mega Amp Spherical Tokamak (MAST) Upgrade was compared to measurements carried out with a fission chamber (neutron fluxes) and a fast ion deuterium-alpha (FIDA) diagnostic. A simple model was developed to reconstruct the outer-midplane neutral density based on measurements of deuterium-alpha emission from edge neutrals, and on Thomson scattering measurements of electron density and temperature. The main computational tools used were the ASCOT orbit-following code and the FIDASIM code for producing synthetic FIDA signals. The neutral density reconstruction agrees qualitatively with SOLPS-ITER modelling and yields a synthetic passive FIDA signal that is consistent with measurement. When CX losses of beam ions are accounted for, predicted neutron emission rates are quantitatively more consistent with measurement. It was necessary to account for CX losses of beam ions in simulations to reproduce the measured passive FIDA signal quantitatively and qualitatively. The results suggest that the neutral density reconstruction is a good approximation, that CX with edge neutrals causes significant beam-ion losses in MAST Upgrade, typically 20% of beam power, and that the ASCOT fast-ion CX model can be used to accurately predict the redistribution and loss of beam ions due to CX.

Physics↗

An extended focused assessment with sonography in trauma ultrasound tissue-mimicking phantom for developing automated diagnostic technologies

Medical imaging-based triage is critical for ensuring medical treatment is timely and prioritized. However, without proper image collection and interpretation, triage decisions can be hard to make. While automation approaches can enhance these triage applications, tissue phantoms must be developed to train and mature these novel technologies. Here, we have developed a tissue phantom modeling the ultrasound views imaged during the enhanced focused assessment with sonography in trauma exam (eFAST). The tissue phantom utilized synthetic clear ballistic gel with carveouts in the abdomen and rib cage corresponding to the various eFAST scan points. Various approaches were taken to simulate proper physiology without injuries present or to mimic pneumothorax, hemothorax, or abdominal hemorrhage at multiple locations in the torso. Multiple ultrasound imaging systems were used to acquire ultrasound scans with or without injury present and were used to train deep learning image classification predictive models. Performance of the artificial intelligent (AI) models trained in this study achieved over 97% accuracy for each eFAST scan site. We used a previously trained AI model for pneumothorax which achieved 74% accuracy in blind predictions for images collected with the novel eFAST tissue phantom. Grad-CAM heat map overlays for the predictions identified that the AI models were tracking the area of interest for each scan point in the tissue phantom. Overall, the eFAST tissue phantom ultrasound scans resembled human images and were successful in training AI models. Tissue phantoms are critical first steps in troubleshooting and developing medical imaging automation technologies for this application that can accelerate the widespread use of ultrasound imaging for emergency triage.

60 APPLIED LIFE SCIENCES↗

Development of limited-view tomography for measurement of Spray G plume direction and liquid volume fraction

Abstract The method for direct injection of fuel in the cylinder of an IC engines is important to high-efficiency and low-emission performance. Optical spray diagnostics plays an important role in understanding plume movement and interaction for multi-hole injectors, and providing baseline understanding used for computational optimization of fuel delivery. Traditional planar or line-of-sight diagnostics fail to capture the liquid distribution because of optical thickness concerns. This work proposes a high-speed (67 kHz) extinction imaging technique at various injector rotations coupled to computed tomography (CT) for time-resolved reconstruction of liquid volume fraction in three dimensions. The number of views selected and processing were based on synthetic (modeled) liquid volume fraction data where extinction and CT adequately reconstructed each plume. The exercise showed that for an 8-hole, symmetric-design injector (ECN Spray G), only three different views are enough to reproduce the direction of each plume, and particularly the mean plume direction. Therefore, the number of views was minimized for experiments to save expense. Measurements applying this limited-view technique confirm plume–plume variations also detected with mechanical patternation, while providing better spatial and temporal resolution than achieved previously. Uncertainties due to the limited view within pressurized spray chambers, the droplet size, and optically thick regions are discussed. Graphic abstract

42 ENGINEERING↗

Toward electron temperature profiles in hot-dense plasmas from x-ray spectral ensembles

High repetition rate laser systems enable new strategies for diagnosing plasma behavior with large datasets. Here, we define an ensemble technique that relies on randomized targeting of x-ray tracer micro-stripes. On each shot, a high-intensity laser pulse is focused on a solid target with Ti tracer stripes embedded in an Al foil, randomly targeting a micro-stripe, a portion of a stripe, or a gap between stripes. High-resolution, time-integrated x-ray spectrometers capture line emission from the portion of the micro-stripe that is heated to sufficiently high electron temperatures. Accumulation of many such cases is used to construct ensemble distributions of x-ray line intensities that encompass all relative offsets of the laser focus to the micro-stripe centers. Synthetic intensity distributions are likewise generated using collisional-radiative modeling. Bayesian fitting of modeled to measured intensity distributions establishes the most likely radial temperature profiles, enabling comparison to hydrodynamic models and calling into question the cylindrical symmetry of these micro-stripe-embedded systems. Ensemble techniques have significant potential for high-energy-density plasma diagnostics, especially with the advent of high repetition rate experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CeMbio - The Caenorhabditis elegans Microbiome Resource

The study of microbiomes by sequencing has revealed a plethora of correlations between microbial community composition and various life-history characteristics of the corresponding host species. However, inferring causation from correlation is often hampered by the sheer compositional complexity of microbiomes, even in simple organisms. Synthetic communities offer an effective approach to infer cause-effect relationships in host-microbiome systems. Yet the available communities suffer from several drawbacks, such as artificial (thus non-natural) choice of microbes, microbe-host mismatch (e.g., human microbes in gnotobiotic mice), or hosts lacking genetic tractability. Here we introduce CeMbio, a simplified natural Caenorhabditis elegans microbiota derived from our previous meta-analysis of the natural microbiome of this nematode. The CeMbio resource is amenable to all strengths of the C. elegans model system, strains included are readily culturable, they all colonize the worm gut individually, and comprise a robust community that distinctly affects nematode life-history. Several tools have additionally been developed for the CeMbio strains, including diagnostic PCR primers, completely sequenced genomes, and metabolic network models. With CeMbio, we provide a versatile resource and toolbox for the in-depth dissection of naturally relevant host-microbiome interactions in C. elegans.

59 BASIC BIOLOGICAL SCIENCES↗

A Benchmark to Test Generalization Capabilities of Deep Learning Methods to Classify Severe Convective Storms in a Changing Climate

Abstract This is a test case study assessing the ability of deep learning methods to generalize to a future climate (end of 21st century) when trained to classify thunderstorms in model output representative of the present‐day climate. A convolutional neural network (CNN) was trained to classify strongly rotating thunderstorms from a current climate created using the Weather Research and Forecasting model at high‐resolution, then evaluated against thunderstorms from a future climate and found to perform with skill and comparatively in both climates. Despite training with labels derived from a threshold value of a severe thunderstorm diagnostic (updraft helicity), which was not used as an input attribute, the CNN learned physical characteristics of organized convection and environments that are not captured by the diagnostic heuristic. Physical features were not prescribed but rather learned from the data, such as the importance of dry air at mid‐levels for intense thunderstorm development when low‐level moisture is present (i.e., convective available potential energy). Explanation techniques also revealed that thunderstorms classified as strongly rotating are associated with learned rotation signatures. Results show that the creation of synthetic data with ground truth is a viable alternative to human‐labeled data and that a CNN is able to generalize a target using learned features that would be difficult to encode due to spatial complexity. Most importantly, results from this study show that deep learning is capable of generalizing to future climate extremes and can exhibit out‐of‐sample robustness with hyperparameter tuning in certain applications.

54 ENVIRONMENTAL SCIENCES↗

Applications of machine learning to a compact magnetic spectrometer for high repetition rate, laser-driven particle acceleration

Accurately and rapidly diagnosing laser–plasma interactions is often difficult due to the time-intensive nature of the analysis and will only become more so with the rise of high repetition rate lasers and the desire to implement feedback on a commensurate timescale. Diagnostic analysis employing machine learning techniques can help address this problem while maintaining a high degree of accuracy. We report on the application of machine learning to the analysis of a scintillator-based electron spectrometer for experiments on high intensity, laser–plasma interactions at the Colorado State University Advanced Lasers and Extreme Photonics facility. Our approach utilizes a neural network trained on synthetic data and tested on experiments to extract the accelerated electron temperature. By leveraging transfer learning, we demonstrate an improvement in the neural network accuracy, decreasing the network error by 50%.

Swanson, K. K. (ORCID:0000000286880568)↗

Deep learning based x-ray spectrometer for high repetition rate characterization of betatron radiation

Betatron radiation produced from a laser-wakefield accelerator is a broadband, hard x-ray (>1 keV) source that has been used in a variety of applications in medicine, engineering, and fundamental science. Further development and optimization of stable, high repetition rate (HRR) (>1 Hz) betatron sources will provide a means to extend their application base to include single-shot dynamical measurements of ultrafast processes or dense materials. Recent advances in laser technology used in such experiments have enabled increases in shot-rate and system stability, providing improved statistical analysis and detailed parameter scans. However, unique challenges exist at high repetition rate, where data throughput and source optimization are now limited by diagnostic acquisition rates and analysis. Here, we present the development of a machine-learning algorithm for the real-time analysis of betatron radiation. We report on the fielding of this deep learning algorithm for online source characterization at the Institut National de la Recherche Scientifique's Advanced Laser Light Source. By fine-tuning an algorithm originally trained on a fully synthetic dataset using a subset of experimental data, the algorithm can predict the betatron critical energy with a percent error of 7.2 % with a reconstruction time of 1.5 ms, providing a valuable tool for real-time, multi-objective optimization at HRR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D

A recent upgrade to the Imaging Neutral Particle Analyzer (INPA) on DIII-D has allowed for the first fluctuation measurements using an INPA to be taken during a neoclassical tearing mode (NTM). The INPA signal tracked the mode over 150 ms as the mode frequency dropped to zero, capturing both the NTM with poloidal and toroidal mode numbers $m/n=2/1$ and a $3/2$ mode at double the frequency. Analysis shows that the signals originate from charge exchange events near the edge of the plasma, and relative fluctuation amplitudes are greater than 25% for the duration of the NTM. Filtered signals show frequency beating patterns that are phase-space dependent. Simulated signal is dominated by prompt transport from the neutral beams to the INPA sightline, while the contribution from the slowing down distribution is significantly lower. Simulated measurements in the range of pitches that the diagnostic is sensitive to (0.5≤|v∥/v|≤ 0.75) show the signal is dominated by trapped orbits that pass through magnetic islands near the edge of the plasma. Calculations of expected fluctuation levels show that only direct interaction with the NTM can provide the strong relative fluctuation levels seen experimentally. The prompt nature of the orbits and thin radial layer found to contribute to synthetic signals suggest INPA passive data may be used to measure the perturbations of confined orbits on a single pass through a plasma instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗