Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface acoustic waves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Homoepitaxial ZnO Film Growth

ZnO films have high potential for many applications, such as surface acoustic wave filters, UV detectors, and light emitting devices due to its structural, electrical, and optical properties. High quality epitaxial films are required for these applications. The Al2O3 substrate is commonly used for ZnO heteroepitaxial growth. Recently, high quality ZnO single crystals are available for grow homoepitaxial films. Epitaxial ZnO films were grown on the two polar surfaces (O-face and Zn-face) of (0001) ZnO single crystal substrates using off-axis magnetron sputtering deposition. As a comparison, films were also deposited on (0001) Al2O3 substrates. It was found that the two polar ZnO surfaces have different photoluminescence (PL) spectrum, surface structure and morphology, which strongly influence the epitaxial film growth. The morphology and structure of homoepitaxial films grown on the ZnO substrates were different from heteroepitaxial films grown on the Al2O3. An interesting result shows that high temperature annealing of ZnO single crystals will improve the surface structure on the O-face surface rather than the opposite surface. The measurements of PL, low-angle incident x-ray diffraction, and atomic force microscopy of ZnO films indicate that the O-terminated surface is better for ZnO epitaxial film growth.

Zhu, Shen↗

Extended Range Passive Wireless Tag System and Method

A passive wireless tag assembly comprises a plurality of antennas and transmission lines interconnected with circuitry and constructed and arranged in a Van Atta array or configuration to reflect an interrogator signal in the direction from where it came. The circuitry may comprise at least one surface acoustic wave (SAW)-based circuit that functions as a signal reflector and is operatively connected with an information circuit. In another embodiment, at least one delay circuit and/or at least one passive modulation circuit(s) are utilized. In yet another embodiment, antennas connected to SAW-based devices are mounted to at least one of the orthogonal surfaces of a corner reflector.

Fink, Patrick W.↗

Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

White, Richard M.↗

Cleanroom Contaminant Monitor

Under a Small Business Innovation Research (SBIR) contract from Kennedy Space Center (KSC), Femtometrics, Inc. developed the Real-Time Non-Volatile Residue (NVR) monitor. Criteria established by KSC called for a technology that could regulate the accumulation of nonvolatile residues in cleanroom environments. The company accommodated the Center's need with an advanced, highly sensitive surface acoustic wave (SAW) microsensor capable of detecting sub-monolayer deposition in cleanrooms where aerospace systems are assembled. Years earlier, Femtometrics responded to and received SBIR contracts from Langley Research Center for highly sensitive aerosol detectors for environmental researchers. Stimulated by the SBIR wins, the company set about to develop the SAW resonator technology. A new type of sensor has evolved from the research, one that has the ability to measure a range of chemical vapors by applying chemical-specific coating on the sensing surface. Commercial applications of the Real-Time NVR include Class 1 cleanrooms at semiconductor and hard-disk manufacturing plants.

Source record↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Real-Time Deposition Monitor for Ultrathin Conductive Films

A device has been developed that can be used for the real-time monitoring of ultrathin (2 or more) conductive films. The device responds in less than two microseconds, and can be used to monitor film depositions up to about 60 thick. Actual thickness monitoring capability will vary based on properties of the film being deposited. This is a single-use device, which, due to the very low device cost, can be disposable. Conventional quartz/crystal microbalance devices have proven inadequate to monitor the thickness of Pd films during deposition of ultrathin films for hydrogen sensor devices. When the deposited film is less than 100 , the QCM measurements are inadequate to allow monitoring of the ultrathin films being developed. Thus, an improved, high-sensitivity, real-time deposition monitor was needed to continue Pd film deposition development. The new deposition monitor utilizes a surface acoustic wave (SAW) device in a differential delay-line configuration to produce both a reference response and a response for the portion of the device on which the film is being deposited. Both responses are monitored simultaneously during deposition. The reference response remains unchanged, while the attenuation of the sensing path (where the film is being deposited) varies as the film thickness increases. This device utilizes the fact that on high-coupling piezoelectric substrates, the attenuation of an SAW undergoes a transition from low to very high, and back to low as the conductivity of a film on the device surface goes from nonconductive to highly conductive. Thus, the sensing path response starts with a low insertion loss, and as a conductive film is deposited, the film conductivity increases, causing the device insertion loss to increase dramatically (by up to 80 dB or more), and then with continued film thickness increases (and the corresponding conductivity increases), the device insertion loss goes back down to the low level at which it started. This provides a continuous, real-time monitoring of film deposition. For use with different films, the device would need to be calibrated to provide an understanding of how film thickness is related to film conductivity, as the device is responding primarily to conductivity effects (and not to mass loading effects) in this ultrathin film regime.

Hines, Jacqueline↗

A digital signal processing system for coherent laser radar

A data processing system for use with continuous-wave lidar is described in terms of its configuration and performance during the second survey mission of NASA'a Global Backscatter Experiment. The system is designed to estimate a complete lidar spectrum in real time, record the data from two lidars, and monitor variables related to the lidar operating environment. The PC-based system includes a transient capture board, a digital-signal processing (DSP) board, and a low-speed data-acquisition board. Both unprocessed and processed lidar spectrum data are monitored in real time, and the results are compared to those of a previous non-DSP-based system. Because the DSP-based system is digital it is slower than the surface-acoustic-wave signal processor and collects 2500 spectra/s. However, the DSP-based system provides complete data sets at two wavelengths from the continuous-wave lidars.

Hampton, Diana M.↗

Micro Weather Station

Improved in situ meteorological measurements in the troposphere and stratosphere are needed for studies of weather and climate, both as a primary data source and as validation for remote sensing instruments. Following the initial development and successful flight validation of the surface acoustic wave (SAW) hygrometer, the micro weather station program was directed toward the development of an integrated instrument, capable of accurate, in situ profiling of the troposphere, and small enough to fly on a radiosonde balloon for direct comparison with standard radiosondes. On April 23, 1998, working with Frank Schmidlin and Bob Olson of Wallops Island Flight Facility, we flew our instrument in a dual payload experiment, for validation and direct comparison with a Vaisala radiosonde. During that flight, the SAW dewpoint hygrometer measured frostpoint down to -76T at 44,000 feet. Using a laptop computer in radio contact with the balloon, we monitored data in real time, issued the cutdown command, and recovered the payload less than an hour after landing in White Sands Missile Range, 50 miles from the launch site in Hatch, New Mexico. Future flights will extend the intercomparison, and attempt to obtain in situ meteorological profiles from the surface through the tropopause. The SAW hygrometer was successfully deployed on the NASA DC8 as part of NASA's Third Convection and Moisture Experiment (CAMEX-3) during August and September, 1998. This field campaign was devoted to the study of hurricane tracking and intensification using NASA-funded aircraft. In situ humidity data from the SAW hygrometer are currently being analyzed and compared with data from other instruments on the DC8 and ER2 aircraft. Additional information is contained in the original.

Hoenk, Michael E.↗

NASA Tech Briefs, October 2010

Topics covered include: Hybrid Architecture Active Wavefront Sensing and Control; Carbon-Nanotube-Based Chemical Gas Sensor; Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials; Graphene-Based Reversible Nano-Switch/Sensor Schottky Diode; Inductive Non-Contact Position Sensor; High-Temperature Surface-Acoustic-Wave Transducer; Grid-Sphere Electrodes for Contact with Ionospheric Plasma; Enabling IP Header Compression in COTS Routers via Frame Relay on a Simplex Link; Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications; Robust Optimization Design Algorithm for High-Frequency TWTs; Optimal and Local Connectivity Between Neuron and Synapse Array in the Quantum Dot/Silicon Brain; Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space; BGen: A UML Behavior Network Generator Tool; Platform for Post-Processing Waveform-Based NDE; Electrochemical Hydrogen Peroxide Generator; Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures; Process to Create High-Fidelity Lunar Dust Simulants; Lithium-Ion Electrolytes Containing Phosphorous-Based, Flame-Retardant Additives; InGaP Heterojunction Barrier Solar Cells; Straight-Pore Microfilter with Efficient Regeneration; Determining Shear Stress Distribution in a Laminate; Self-Adjusting Liquid Injectors for Combustors; Handling Qualities Prediction of an F-16XL-Based Reduced Sonic Boom Aircraft; Tele-Robotic ATHLETE Controller for Kinematics - TRACK; Three-Wheel Brush-Wheel Sampler; Heterodyne Interferometer Angle Metrology; Aligning Astronomical Telescopes via Identification of Stars; Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump; Large-Format AlGaN PIN Photodiode Arrays for UV Images; Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems; On Calculating the Zero-Gravity Surface Figure of a Mirror; Optical Modification of Casimir Forces for Improved Function of Micro- and Nano-Scale Devices; Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems; Core and Off-Core Processes in Systems Engineering; Digital Reconstruction Supporting Investigation of Mishaps; and Template Matching Approach to Signal Prediction.

Source record↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Microstructural and material property changes in severely deformed Eurofer-97

Severe plastic deformation changes the microstructure and properties of steels, which may be favourable for their use in structural components of nuclear reactors. In this study, high-pressure torsion (HPT) was used to refine the grain structure of Eurofer-97, a ferritic/martensitic steel. Electron microscopy and X-ray diffraction were used to characterise the microstructural changes. Following HPT at room temperature to a maximum shear strain of 230, the average grain size reduced by a factor of ~30, with a marked increase in high-angle grain boundaries. Dislocation density also increased by more than one order of magnitude. The thermal stability of the deformed material was investigated via in-situ annealing during synchrotron X-ray diffraction. This revealed substantial recovery between 450 K – 800 K. Irradiation with 20 MeV Fe-ions to ~0.1 dpa caused a 20% reduction in dislocation density compared to the as-deformed material. However, HPT deformation prior to irradiation only had a minor effect in mitigating the irradiation-induced reductions in thermal diffusivity and surface acoustic wave velocity of the material. Microstructural and material property changes are dominated by deformation compared to irradiation. In light of this, the benefits of using HPT to improve the irradiation resistance of Eurofer-97 are limited. These results provide a multi-faceted view of the changes in ferritic/martensitic steels due to severe plastic deformation, and how these changes can be used to alter material properties.

ion-irradiation↗

Dynamic Carrier Modulation via Nonlinear Acoustoelectric Transport in van der Waals Heterostructures

Dynamically manipulating carriers in van der Waals heterostructures could enable solid-state quantum simulators with tunable lattice parameters. A key requirement is the formation of deep potential wells to reliably trap excitations. Here, we report the observation of nonlinear acoustoelectric transport and dynamic carrier modulation in boron nitride-encapsulated graphene devices coupled to intense surface acoustic waves (SAWs) on LiNbO 3 substrates. SAWs generate strong acoustoelectric current densities ( J AE ), transitioning from linear to nonlinear regimes with increasing SAW intensity. In the nonlinear regime, periodic carrier (electrons, holes, or their mixtures) stripes emerge. Using counter-propagating SAWs, we create standing SAWs (SSAWs) to dynamically manipulate charge distributions without static gates. The saturation of J AE , attenuation transitions, and tunable resistance peaks confirms strong carrier localization. Finally, these results establish SAWs as a powerful tool for controlling carrier dynamics in two-dimensional (2D) materials, paving the way for the development of time-dependent quantum systems and acoustic lattices for quantum simulation.

2D materials↗

Deterministic multi-phonon entanglement between two mechanical resonators on separate substrates

Mechanical systems have emerged as a compelling platform for applications in quantum information, leveraging advances in the control of phonons, the quanta of mechanical vibrations. Experiments have demonstrated the control and measurement of phonon states in mechanical resonators, and while dual-resonator entanglement has been demonstrated, more complex entangled states remain a challenge. Here, we demonstrate rapid multi-phonon entanglement generation and subsequent tomographic analysis, using a scalable platform comprising two surface acoustic wave resonators on separate substrates, each connected to a superconducting qubit. We synthesize a mechanical Bell state with a fidelity of $\mathcal{F}$ = 0.872 ± 0.002, and a multi-phonon entangled N = 2 N00N state with a fidelity of $\mathcal{F}$ = 0.748 ± 0.008. The compact, modular, and scalable platform we demonstrate will enable further advances in the quantum control of complex mechanical systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Engineering long-lived entanglement through dissipation in quantum hybrid solid-state platforms

Spin squeezing, a form of many-body entanglement, is a crucial resource in quantum metrology and information processing. While experimentally viable protocols for generating stable spin squeezing have been proposed in quantum optics setups, there is growing interest in quantum hybrid solid-state systems as alternative platforms for both engineering and exploring many-body quantum phenomena. In this work, we propose a scheme to generate long-lived spin squeezing in an ensemble of solid-state qubits interacting with electromagnetic noise emitted by a squeezed solid-state bath. We identify the conditions under which quantum correlations within the bath can be transferred to the qubit array, driving it into an entangled state independently of its initial configuration. To assess the experimental feasibility of our approach, we analyze the dynamics of an array of solid-state spin defects coupled to a common ferromagnetic bath, which is driven into a non-equilibrium squeezed state through its interaction with a surface acoustic wave mode. Our results demonstrate that the ensemble can exhibit steady-state spin squeezing under suitable conditions, opening new pathways for the generation of robust many-body entanglement in solid-state spin ensembles.

NV centers↗

Study for identification of Beneficial Uses of Space (BUS). Volume 2: Technical report. Book 1: Sections 1 through 4

Consolidated information is presented for the study whose purpose was to identify products, processes, and services to be produced in future spacecraft environments for direct utilization on earth. Discussion of methodology for selecting from among potential space processing approaches, definition of requirements for experiments and tests needed to acquire sufficient knowledge for proof testing of selected processes, formulation of research and development schedules to achieve proof testing, and documentation of the decision processes involved in the programs are presented. Technology and programmatics are reported for the following select studies: (1) surface acoustic wave components; (2) transparent oxides; (3) high purity tungsten X-ray targets; and (4) high specificity isoenzymes.

Source record↗

The 1975 NASA/ASEE summer faculty fellowship research program

A research program was conducted to further the professional knowledge of qualified engineering and science faculty members, to stimulate an exchange of ideas between participants and NASA engineers and scientists, and to enrich the research activities of the participants' institutions. Abstracts of reports submitted at the end of the program are presented. Topics investigated include multispectral photography, logic circuits, gravitation theories, information systems, fracture mechanics, holographic interferometry, surface acoustic wave technology, ion beams in the upper atmosphere, and hybrid microcircuits.

Source record↗

Methods utilized in evaluating the profitability of commercial space processing

Profitability analysis is applied to commercial space processing on the basis of business concept definition and assessment and the relationship between ground and space functions. Throughput analysis is demonstrated by analysis of the space manufacturing of surface acoustic wave devices. The paper describes a financial analysis model for space processing and provides key profitability measures for space processed isoenzymes.

Bloom, H. L.↗