Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Static and Fatigue Characterization of Large Composite T-Bolt Connections in Marine Hygrothermal Environments

Fiber-reinforced polymer composites have been highlighted as ideal candidates for structural applications in marine renewable energy devices, such as tidal turbines and wave energy converters. It is well understood that harsh marine environments can cause strength degradation of composite laminates, which has been extensively researched at the coupon scale; however, no research has investigated how this translates into larger-scale composite structures. This paper presents a subcomponent-scale study which investigates the effects of hygrothermal aging and subsequent static and fatigue characterization of thick composite T-bolt connections as part of a large, multilaboratory materials research effort. Of the glass-reinforced epoxy and vinylester-epoxy matrix composites tested, both showed measurable static strength degradation (4–36%) after being hygrothermally aged, even though the composite specimens were only partially saturated with water. Under tension–tension fatigue loading, the epoxy specimens performed very well in their dry states but exhibited significant degradation after hygrothermal aging. In comparison, the vinylester-epoxy specimens had much shorter fatigue lives in their dry states but exhibited no degradation after hygrothermal aging. Overall, this research demonstrates that hygrothermal aging can have significant effects on the ultimate strengths and fatigue lives of even partially saturated thick composite T-bolt connections, indicating that degradation of the outer plies on thick composite laminates can have pronounced effects on the whole structure. It discusses the challenges of building an understanding of the effects of harsh marine environments in large-scale composite structures.

16 TIDAL AND WAVE POWER↗

Fast GPU-Based Generation of Large Graph Networks From Degree Distributions

Synthetically generated, large graph networks serve as useful proxies to real-world networks for many graph-based applications. The ability to generate such networks helps overcome several limitations of real-world networks regarding their number, availability, and access. Here, we present the design, implementation, and performance study of a novel network generator that can produce very large graph networks conforming to any desired degree distribution. The generator is designed and implemented for efficient execution on modern graphics processing units (GPUs). Given an array of desired vertex degrees and number of vertices for each desired degree, our algorithm generates the edges of a random graph that satisfies the input degree distribution. Multiple runtime variants are implemented and tested: 1) a uniform static work assignment using a fixed thread launch scheme, 2) a load-balanced static work assignment also with fixed thread launch but with cost-aware task-to-thread mapping, and 3) a dynamic scheme with multiple GPU kernels asynchronously launched from the CPU. The generation is tested on a range of popular networks such as Twitter and Facebook, representing different scales and skews in degree distributions. Results show that, using our algorithm on a single modern GPU (NVIDIA Volta V100), it is possible to generate large-scale graph networks at rates exceeding 50 billion edges per second for a 69 billion-edge network. GPU profiling confirms high utilization and low branching divergence of our implementation from small to large network sizes. For networks with scattered distributions, we provide a coarsening method that further increases the GPU-based generation speed by up to a factor of 4 on tested input networks with over 45 billion edges.

97 MATHEMATICS AND COMPUTING↗

Overview of 2017 Through 2018 Testing of Powered Air-Purifying Respirator (PAPR) Cartridge Performance on Multiple Hanford Tank Headspaces and Exhausters

Between 2017 and 2018, 10 powered air-purifying respirator (PAPR) cartridge tests were performed on headspace vapors from three Hanford tanks (BY-108, SX-101, and SX-104) and two Hanford Tank Farm exhausters (AP in 2018 and AX in 2017). All tests were conducted under static conditions absent waste-disturbing activities in the subject tanks or tank farms. Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota), were tested on each of the five tanks or exhausters. Out of 61 1 Chemicals of Potential Concern (COPCs), only ammonia and 2,5-dimethylfuran exhibited breakthroughs with outlet concentrations that were greater than 10% of their Occupational Exposure Limits (OEL). For 2,5-dimethylfuran, elevated concentrations found in blank tube samples made the elevated outlet measurements for this COPC questionable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of static heat loads of the PIP-II cryomodules based on prototype HB650 cryomodule test results

During the first cool down of the prototype HB650 cryomodule (pHB650 CM), high static heat loads have been measured compared to the estimation. Several analysis and calculations have been performed to explain this difference which led to cool down this cryomodule two additional times. Before each cool down, repairs and upgrades have been done, and instrumentations were added to identify the issues and quantify their impact on the heat loads. Based on these findings, the production cryomodule design and assembly process have been updated to align the future heat loads measurements with the estimations.

43 PARTICLE ACCELERATORS↗

Agile Acceleration of LLVM Flang Support for Fortran 2018 Parallel Programming

The LLVM Flang compiler ("Flang") is currently Fortran 95 compliant, and the frontend can parse Fortran 2018. However, Flang does not have a comprehensive 2018 test suite and does not fully implement the static semantics of the 2018 standard. We are investigating whether agile software development techniques, such as pair programming and test-driven development (TDD), can help Flang to rapidly progress to Fortran 2018 compliance. Because of the paramount importance of parallelism in high-performance computing, we are focusing on Fortran’s parallel features, commonly denoted “Coarray Fortran.” We are developing what we believe are the first exhaustive, open-source tests for the static semantics of Fortran 2018 parallel features, and contributing them to the LLVM project. A related effort involves writing runtime tests for parallel 2018 features and supporting those tests by developing a new parallel runtime library: the CoArray Fortran Framework of Efficient Interfaces to Network Environments (Caffeine).

Rasmussen, Katherine↗

Multi‐fidelity digital twin structural model for a sub‐scale downwind wind turbine rotor blade

Abstract This paper presents the development of a multi‐fidelity digital twin structural model (virtual model) of an as‐built wind turbine blade. The goal is to develop and demonstrate an approach to produce an accurate and detailed model of the as‐built blade for use in verifying the performance of the operating two‐bladed, downwind rotor. The digital twin model development methodology, presented herein, involves a novel calibration process to integrate a wide range of information including design specifications, manufacturing information, and structural testing data (modal and static) to produce a multi‐fidelity digital twin structural model: a detailed high‐fidelity model (i.e., 3D finite element analysis [FEA]) and consistent beam‐type models for aeroelastic simulation. A key element is that the multi‐fidelity structural digital twin method follows the rotor from the stages of design, to manufacturing, then to the ground testing and field operation. The result of this comprehensive approach is an accurate multi‐fidelity digital twin structural model for the geometric, structural, and structural dynamic properties of the as‐built blade within a 1% match in mass properties, 3.2% in blade frequencies, and 6% in deflection. The different stages of processing this information within the methodology are discussed. The rotor examined is the SUMR‐Demonstrator (SUMR‐D), which was installed on the Controls Advanced Research Testbed (CART‐2) wind turbine at the National Wind Technology Center. The digital twin model developed here was utilized to design controllers to safely operate SUMR‐D in field tests, which are providing additional data for further evaluation and development of the multi‐fidelity digital twin structural model.

Chetan, Mayank↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Niobium addition improves the corrosion resistance of TiHfZrNb x high-entropy alloys in Hanks’ solution

High-strength TiHfZrNb x high-entropy alloys could become the ideal materials for small-diameter endovascular stents once their corrosion resistance in the physiological milieu is confirmed. Here, this work aims at evaluating the corrosion resistance of a TiHfZrNb x high-entropy-alloys family in Hanks’ solution at 37 °C and revealing the influence of niobium on the mechanisms of dissolution and passivation. The alloys were subjected to a series of static and dynamic electrochemical tests and surface characterization, employing the static/dynamic/cyclic polarizations, impedance spectroscopy, XPS, AFM, and SEM. Results confirm a higher corrosion resistance of the alloys compared to that of CP-Ti and Ti6Al4V. The addition of niobium considerably improves the microstructural homogeneity that ensures a low dissolution rate and a greater resistance of the film due to the lower concentration of point defects. The passive film behaves as an n-type semiconductor and is composed of a mixture of TiO 2 , Nb 2 O 5 , ZrO 2 , and HfO 2 oxides, with the presence of metallic hydroxides on the outermost layer. A detailed description of the niobium influence on the mechanisms of the dissolution and passivation is presented in this work.

36 MATERIALS SCIENCE↗

Design of separate-effects In-Pile transient boiling experiments at the $\mathrm{TREAT}$ Facility

The cladding-to-coolant heat transfer during rapid power excursions, such as reactivity-initiated accidents, remains a crucial area of uncertainty in nuclear reactor safety. This uncertainty impacts the ability to accurately predict fuel performance behavior for these conditions. Improving our understanding of transient cladding-to-coolant heat transfer will enhance our ability to model design basis accidents and could increase design and improve safety margins for the current commercial fleet and advanced reactors. To address these issues, the Critical Heat Flux Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA) experiment uses a novel approach with a borated stainless-steel heater rodlet that can replicate cladding temperatures experienced during a design-basis reactivity-initiated accident. The rodlet and experiment is instrumented to provide temperature and thermal-hydraulic conditions throughout the transient. The design of the rodlet allows for separate effect testing that eliminates complexities with a fuel and cladding specimen. We report the experiments have provided data that will be used to improve our understanding of boiling behavior, specifically critical heat flux, under transient conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Green mechanochemical synthesis of imine-linked covalent organic frameworks for high iodine capture

Covalent organic frameworks (COFs) have emerged as promising adsorbents for radioiodine capture. However, the conventional solvothermal synthesis contradicts the principles of green chemistry due to the use of hazardous solvents, long reaction times (typically 3 days), and high reaction temperatures. Here, to address these issues, we demonstrate for the first time the green, efficient, liquid-assisted mechanochemical synthesis of COF adsorbents for high iodine capture. The ball milling synthesis was performed with various liquid additives at ambient temperature, yielding six imine-linked COFs of diverse pore sizes and functionalities in merely 1 hour. Notably, one representative COF exhibited high crystallinity and a remarkable surface area of 1387 m 2 g –1 in just 1 minute of ball milling. When tested as adsorbents for static iodine vapor capture at 75 °C, four mechanochemically synthesized COFs exhibited outstanding iodine adsorption capacities of 6.4–7.1 g g –1 , comparable to or exceeding those of solvothermally synthesized COF and most reported COF adsorbents. Furthermore, Fourier transform infrared and X-ray photoelectron spectroscopy corroborated the charge transfer between iodine and COF adsorbents. This mechanochemical methodology will pave the path for green, rapid, facile, and scalable synthesis of COFs, revealing great prospects for applications in environmental remediation and beyond.

36 MATERIALS SCIENCE↗

Feasibility of carbon foam-based sorbents for the abatement of gaseous mercury and iodine

The U.S. Department of Energy Hanford Site in Washington State is in the process of commissioning the Waste Treatment and Immobilization Plant to process a portion of the 54 million gallons of radioactive and chemical waste from cold war weapon production. Technologies for the capture of volatile species of concern are still being assessed, and new methods and materials are developed as operational and flowsheet mission risks are identified. One such area still being assessed is the abatement efficacy of the Carbon Adsorber units to retain gaseous mercury and 129 I released during processing. It is challenging to predict the mercury chemistry due to the variability of the feed, and different methods/materials are required for the capture of gaseous Hg 0 and Hg II compounds. In this study, the feasibility of using developmental carbon foam (CF) sorbents for the capture of iodine and mercury was assessed using static and dynamic flow testing and compared against a commercially available sorbent, BATII-37. Both CF and CF functionalized with bismuth particles (CF-Bi) chemisorbed iodine, and CF-Bi had similar mercury capture performance to BATII-37 in dynamic flow tests. While species loading concentrations were measurable, limitations in achieving a mass balance prevented a full evaluation of capture efficacy. Nonetheless, the results serve as an important first step in demonstrating the potential for simultaneous iodine and mercury capture.

Hanford site↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence N - Raw Data

Sequence N: Sin AOA, Rotating (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the presence of rotational influences by varying blade pitch angle. Test sequence N used an upwind, rigid turbine with a 0° cone angle. The wind speed was 15 m/s, and the yaw angle was 0° throughout the sequence. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the Ohio State University (OSU) wind tunnel (Reuss Ramsey et al. 1995) and the 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation N, followed by two digits for the span location (30, 47, 63, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, most of the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence O - Raw Data

Sequence O: Sin AOA, Parked (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the absence of rotational influences by varying blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 18.9 m/s to 39.3 m/s, and the yaw angle was 0° throughout the sequence. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the OSU wind tunnel (Reuss Ramsey et al. 1995) as well as 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation O, followed by two digits for the span location (30, 47, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

17 WIND ENERGY↗

Laser Welded Edge Seals for Glass/Glass Modules

Polymers used in module construction are often involved in degradation mechanisms and hamper recycling. This project explores femtosecond (fs) laser welding of glass/glass modules to enable polymer-free modules. We are utilizing the knowledge base of the industrial laser community to apply glass/glass fs laser welding technology to solar modules. Experimentally measured stress intensity factors for glass welds are input into a COMSOL model of a full-size module to test weld failure under static loading. If successful, fs laser welding could enable modules that are polymer-free that will extend module warrantees, allow hermetically sealed glass/glass modules for moisture-sensitive semiconductors, and improve module recyclability.

COMSOL finite element model↗

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗