Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “static”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The kinetics of static recovery by dislocation climb

Abstract The initial microstructure of a wide range of structural materials is conditioned by thermo-mechanical treatments such as hot-working, tempering, or solution annealing. At the elevated temperatures associated with these treatments the dislocation microstructure evolves, usually decreasing in density through a process known as static recovery. Despite its technological relevance, static recovery is not fully characterized from a theoretical standpoint, with even the controlling mechanisms subject to debate. In this study, a climb-enabled discrete dislocation dynamics (DDD) capability is leveraged to explore the kinetics of static recovery in pure Fe when controlled by dislocation climb. Quantitative data from these simulations is used to develop a revised static recovery law, and provides the parameters appropriate for predictive microstructure models in Fe. This law differs from previous analytical derivations invoking climb of dislocations, following the logarithmic trends typical of experimental observations where prior work did not. Direct comparison between the recovery law derived from DDD to experimental recovery data in alpha Fe shows strong agreement across a range of temperatures, and suggests that climb is the controlling mechanism for static recovery in pure metals.

36 MATERIALS SCIENCE↗

Surface Analytics in Support of the Development of Static AutoClean - an In-Situ Cleaning Process for Ion Implanters

Static AutoClean is a new in-situ cleaning strategy in development at ATMI registered that enables increased process efficiency and safety in the ion implantation process. Like the Dynamic in-situ AutoClean technology previously introduced and released by ATMI, Static AutoClean utilizes XeF{sub 2} chemistry for in-situ cleaning of hazardous contaminants and deposits. Static AutoClean, however, is targeted towards cleaning areas of the beam-line (like electrode insulators or source bushings) where cleaning efforts using Dynamic AutoClean may not be sufficient. An explanation of this cleaning strategy and results showing its effectiveness will be presented in a separate paper at this conference (S. Yedave et al.). This paper presents the surface analytical data and methods used to understand and evaluate the effectiveness of Static AutoClean in removing contaminants from surfaces within the source vacuum chamber. Energy Dispersive Spectroscopy (EDS) was used to track the magnitude and spatial distribution of contaminants present on the surfaces within various regions in the source chamber space of an implanter following ion source operation with a commonly used dopant gas. After in-situ cleaning, these same components and surfaces were re-evaluated by EDS to quantitatively determine the reduction in surface contaminants present within the chamber. Learnings regarding the distribution of implant process contamination within the source chamber as well as Static AutoClean's effectiveness in removing it will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One- and two-photon phase-sensitive coherent control of total ionization yields in the presence of static electric fields

We experimentally demonstrate one- and two-photon phase sensitive coherent control over the excitation and ionization of Rydberg states of Sr atom in the presence of a static homogeneous electric field. Without the field this excitation scheme can only be employed for the manipulation of angular distributions of photoelectrons and molecular photofragmentation products. Total atomic excitation-ionization yields cannot be modulated because the final states excited by each pathway are orthogonal to each other. When, however, a static electric field is applied, s, p and d character is admixed into the final Rydberg state, which has no definite parity anymore. Hence, the excitation of the target Stark state from the ground state is possible with either two (fundamental laser frequency) photons or one (second harmonic frequency) photon and its population and further ionization can be controlled by varying the relative phase between the two radiation fields. The concept is successfully tested below as well as above the classical saddle point and with either mutually crossed or parallel linear laser beam polarizations (while the second harmonic beam polarization vector is always parallel to the static field direction). We examine the behavior of the obtained photoionization signal modulation depth V as a function of the static field strength F for otherwise identical experimental conditions. The V(F) curve exhibits a maximum (typically {approx}65%-85%) at a field strength value that is dictated by the interplay between the employed laser power densities, one- and two-photon transition dipole moments, and relative amounts of field-dependent s, p and d character. It is therefore shown that the static field strength may serve as an additional, experimentally adjustable, control parameter in a fashion complementary to both the intensities and relative phase of the two light beams.

74 ATOMIC AND MOLECULAR PHYSICS↗

Imaginary part of the next-to-leading-order static gluon self-energy in an anisotropic plasma

Using hard-loop (HL) effective theory for an anisotropic non-Abelian plasma, which even in the static limit involves nonvanishing HL vertices, we calculate the imaginary part of the static next-to-leading-order gluon self-energy in the limit of a small anisotropy and with external momentum parallel to the anisotropy direction. At leading order, the static propagator has spacelike poles corresponding to plasma instabilities. On the basis of a calculation using bare vertices, it has been conjectured that, at next-to-leading order, the static gluon self-energy acquires an imaginary part which regulates these spacelike poles. We find that the one-loop resummed expression taken over naively from the imaginary-time formalism does yield a nonvanishing imaginary part even after including all HL vertices. However, this result is not correct. Starting from the real-time formalism, which is required in a nonequilibrium situation, we construct a resummed retarded HL propagator with correct causality properties and show that the static limit of the retarded one-loop-resummed gluon self-energy is real. This result is also required for the time-ordered propagator to exist at next-to-leading order.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

All-Regions Tunable High Harmonic Enhancement by a Periodic Static Electric Field

Simulations show that a static electric field periodically distributed in space can be used to control the production of coherent light by high-order harmonic generation in a wide spectral range covering extreme-ultraviolet and soft x-ray radiation. The radiation yield is selectively enhanced due to symmetry breaking induced by a static electric field on the interaction between the driving laser and the medium. The spectral position of the enhancement is tuned by varying the periodicity of the static electric field which matches twice the coherence length of the harmonics in the desired region. We find that the static electric field strength inducing enhancement decreases for shorter wavelengths and predict an increase of more than two orders of magnitude for harmonics in the water window spectral range with a static electric field as weak as 1.12 MV/cm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and evaluation of aperture-based complexity metrics using film and EPID measurements of static MLC openings

Purpose: Complexity metrics have been suggested as a complement to measurement-based quality assurance for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). However, these metrics have not yet been sufficiently validated. This study develops and evaluates new aperture-based complexity metrics in the context of static multileaf collimator (MLC) openings and compares them to previously published metrics. Methods: This study develops the converted aperture metric and the edge area metric. The converted aperture metric is based on small and irregular parts within the MLC opening that are quantified as measured distances between MLC leaves. The edge area metric is based on the relative size of the region around the edges defined by the MLC. Another metric suggested in this study is the circumference/area ratio. Earlier defined aperture-based complexity metrics—the modulation complexity score, the edge metric, the ratio monitor units (MU)/Gy, the aperture area, and the aperture irregularity—are compared to the newly proposed metrics. A set of small and irregular static MLC openings are created which simulate individual IMRT/VMAT control points of various complexities. These are measured with both an amorphous silicon electronic portal imaging device and EBT3 film. The differences between calculated and measured dose distributions are evaluated using a pixel-by-pixel comparison with two global dose difference criteria of 3% and 5%. The extent of the dose differences, expressed in terms of pass rate, is used as a measure of the complexity of the MLC openings and used for the evaluation of the metrics compared in this study. The different complexity scores are calculated for each created static MLC opening. The correlation between the calculated complexity scores and the extent of the dose differences (pass rate) are analyzed in scatter plots and using Pearson’s r-values. Results: The complexity scores calculated by the edge area metric, converted aperture metric, circumference/area ratio, edge metric, and MU/Gy ratio show good linear correlation to the complexity of the MLC openings, expressed as the 5% dose difference pass rate, with Pearson’s r-values of −0.94, −0.88, −0.84, −0.89, and −0.82, respectively. The overall trends for the 3% and 5% dose difference evaluations are similar. Conclusions: New complexity metrics are developed. The calculated scores correlate to the complexity of the created static MLC openings. The complexity of the MLC opening is dependent on the penumbra region relative to the area of the opening. The aperture-based complexity metrics that combined either the distances between the MLC leaves or the MLC opening circumference with the aperture area show the best correlation with the complexity of the static MLC openings.

60 APPLIED LIFE SCIENCES↗

Integrating Experiments and Well Logs to Predict Caney Shale Static Mechanical Properties During Production with Supervised Machine Learning

Caney shale is one of the emerging oil reservoirs in Oklahoma. Understanding the impact of effective stress on its mechanical properties is critical for predicting hydraulic fracture geometry and overall hydrocarbon production. The objective of our study is to evaluate the impact of effective stress on the dynamic Young’s modulus using ultrasonic velocity measurements for Caney shale samples. A triaxial cell was utilized to measure ultrasonic (P-wave and S-wave) velocities for ten downhole Caney shale samples under various effective stresses to indirectly assess the impact of pore pressure change. The dynamic Young’s moduli estimated from these measurements were integrated with available conventional well logs (excluding sonic logs) and triaxial test results from Benge et al. (2021) to predict the static Young’s modulus using Random Forest (RF) and Extreme Gradient Boosting (XGBoost) models. The results showed that the estimated dynamic Young’s moduli from ultrasonic measurements were higher than the corresponding static Young’s modulus of cores from the same vertical well at similar depths. With increasing effective stress, the dynamic Young’s modulus increased for all samples. The estimated dynamic-to-static correction factor tended to be higher in zones of high neutron porosity (PHIN) and low density compared to other zones. Finally, SHapley Additive exPlanations (SHAP) for RF and XGBoost models identified depth, gamma ray (GR), and PHIN as key features for predicting the static Young’s modulus. This study enhances our understanding of the dynamic and static Young’s moduli for the Caney shale interval, as a function of effective stress and conventional well logs. The findings from this study can improve predictions of production throughout the well's lifespan by offering insights into the mechanical property degradation resulting from pore pressure depletion.

Kholy, Sherif M.↗

A short static-pressure probe design for supersonic flow

A static-pressure probe design concept was developed which has the static holes located close to the probe tip and is relatively insensitive to probe angle of attack and circumferential static hole location. Probes were constructed with 10 and 20 deg half-angle cone tips followed by a tangent conic curve section and a tangent cone section of 2, 3, or 3.5 deg, and were tested at Mach numbers of 2.5 and 4.0 and angles of attack up to 12 deg. Experimental results indicate that for stream Mach numbers of 2.5 and 4.0 and probe angle of attack within + or - 10 deg, values of stream static pressure can be determined from probe calibration to within about + or - 4 percent. If the probe is aligned within about 7 deg of the flow experimental results indicated, the stream static pressures can be determined to within 2 percent from probe calibration.

Pinckney, S. Z.↗

Integration time required to extract accurate static and dynamic data from transonic wind-tunnel tests

Because the forces and pressures on wind-tunnel models tested at transonic speeds are not steady, even for 'static' aerodynamic tests, integration time is required to obtain data of acceptable accuracy. The integration time required for both static and dynamic tests is evaluated analytically and confirmed by experimental measurements. It is shown that, for static and dynamic tests, the accuracy obtained is a function of integration time, frequency content of the signal, and the ratio of the dynamic amplitude to the full signal of interest. In addition, for the dynamic case, the frequency band width used in analysis is important. Results of this study indicate that, for typical data accuracy desired from models in a large transonic wind tunnel (11- by 11-ft), up to the following integration times are required: static force and moment tests, 0.5 sec; static pressure tests, 0.1 sec; flutter tests, 30 to 60 sec; and random-dynamic tests, 10 sec.

Muhlstein, L., Jr.↗

Effect of inlet disturbances on fan inlet noise during a static test

Measurements of fan rotor inlet noise taken during static test situations are at variance with aircraft engine flight data. In particular, static tests generally yield a significantly higher tone at blade passage frequency than that measured during flight. To explain this discrepancy, the extent of the influence of inlet ground vortices and large-scale inlet turbulence on the forward-radiated fan noise measured at a static test facility was investigated. While such inlet disturbances were generated intentionally in an anechoic test chamber, far-field acoustic measurements and inlet flow-field hot-film mappings of a fan rotor were obtained. Experimental results indicate that the acoustic effect of such disturbances appears to be less severe for supersonic than for subsonic tip speeds. Further, a reverse flow that occurs on the exterior cowl in static test facilities appears to be an additional prime candidate for creating inlet disturbances and causing variance between flight and static acoustic data.

Bekofske, K. L.↗

Fan inlet disturbances and their effect on static acoustic data

There is evidence that measurements of fan-rotor inlet noise taken during static test situations are at variance with aircraft engine flight data. In particular, static tests generally yield a significantly higher tone at blade passing frequency than that measured during flight. An experimental program was carried out to investigate this discrepancy. Inlet ground vortices and large-scale inlet turbulence were generated intentionally in an anechoic test chamber. Far-field acoustic measurements and inlet flow field hot film mappings of a fan rotor were then carried out to study the influence of such inlet disturbances at a static test facility. Experimental results indicate that the acoustic effect of such disturbances appears to be less severe for supersonic than for subsonic tip speeds. Further, a reverse flow that occurs on the exterior cowl in static test facilities appears to be an additional prime candidate for creating inlet disturbances and causing variance between flight and static acoustic data.

Bekofske, K. L.↗

Studies on proper simulation during static testing of forward speed effects on fan noise

Significant differences exist in the noise generated by engines in flight and engines operating on the test stand. It was observed that these differences can be reduced by the use of an inflow control structure (ICS) in the static test configuration. The results of the third phase of a three phase program are described. The work performed in the first two phases which dealt with the development of a model for atmospheric turbulence, studies of fan noise generated by rotor turbulence interaction, and the development of an inflow control structure design system are summarized. The final phase of the program covers procedures for performing static testing with an ICS projecting the resulting static test data to actual flight test data. Included is a procedures report which covers the design system and techniques for static testing and projecting the static data to flight.

Peracchio, A. A.↗

Cardiovascular responses to static exercise in distance runners and weight lifters

Three groups of athletes including long-distance runners, competitive and amateur weight lifters, and age- and sex-matched control subjects have been studied by hemodynamic and echocardiographic methods in order to determine the effect of the training programs on the cardiovascular response to static exercise. Blood pressure, heart rate, and double product data at rest and at fatigue suggest that competitive endurance (dynamic exercise) training alters the cardiovascular response to static exercise. In contrast to endurance exercise, weight lifting (static exercise) training does not alter the cardiovascular response to static exercise: weight lifters responded to static exercise in a manner very similar to that of the control subjects.

Longhurst, J. C.↗

Hot-film static-pressure probe for surveying flow fields

A static pressure probe employing hot-film sensors has been developed for the rapid measurement of the static pressure fields surrounding analytic shapes in hypersonic flows. The hot-film probe is a modification of the standard static pressure probe, consisting of a front hot-film sensor operated as a resistance thermometer, a rear sensor operated at an overheat ratio of 1.5 to 1.8 and a small sonic orifice installed inside the tubing of a conventional device. The probe has been calibrated in helium and air over a range of temperatures and pressures in a bell jar apparatus, with a repeatability of the data to within + or - 0.015 mm Hg. Comparative tests of the hot-film and conventional static pressure probes in a hypersonic helium wind tunnel at Mach 20 and various Reynolds numbers have indicated the settling time of the hot-film probe to be on the order of milliseconds, as compared with 30 sec for the conventional probe. The pressures measured by the two probes were found to be within 10% of each other. Although the hot-film probe makes flow-field static pressure surveys more practical in blowdown hypersonic wind tunnels, viscous and flow angle effects still must be assessed under the conditions of use.

Ashby, G. C., Jr.↗

A piloted simulator investigation of static stability and stability/control augmentation effects on helicopter handling qualities for instrument approach

A ground simulator experiment was conducted on the Flight Simulator for Advanced Aircraft at Ames Research Center to investigate the influence of several static stability and stability/control augmentation design parameters on helicopter flying qualities during terminal area operations in instrument conditions. Effects of light turbulence were included. Two levels of static stability in each rotational axis (pitch, roll, yaw) were examined for a hingeless rotor configuration. The variations in pitch and roll were: (1) stable and (2) neutral static stability; in yaw there were two stable levels. Four types of stability/control augmentation were also examined for the lower level of static stability in each axis. This latter investigation covered three helicopter rotor types: hingeless, articulated, and teetering. Four pilots performed a total of 105 evaluations of these parameters for a representative VOR instrument approach task. Pilot rating results indicate the acceptability of neutral static stability longitudinally and laterally and the need for pitch-roll attitude augmentation to achieve a satisfactory system.

Lebacqz, J. V.↗

Handling qualities of a wide-body transport airplane utilizing Pitch Active Control Systems (PACS) for relaxed static stability application

Piloted simulation studies have been conducted to evaluate the effectiveness of two pitch active control systems (PACS) on the flying qualities of a wide-body transport airplane when operating at negative static margins. These two pitch active control systems consisted of a simple 'near-term' PACS and a more complex 'advanced' PACS. Eight different flight conditions, representing the entire flight envelope, were evaluated with emphasis on the cruise flight conditions. These studies were made utilizing the Langley Visual/Motion Simulator (VMS) which has six degrees of freedom. The simulation tests indicated that (1) the flying qualities of the baseline aircraft (PACS off) for the cruise and other high-speed flight conditions were unacceptable at center-of-gravity positions aft of the neutral static stability point; (2) within the linear static stability flight envelope, the near-term PACS provided acceptable flying qualities for static stabilty margins to -3 percent; and (3) with the advanced PACS operative, the flying qualities were demonstrated to be good (satisfactory to very acceptable) for static stabilty margins to -20 percent.

Grantham, William D.↗

Scaling effects in the static and dynamic response of graphite-epoxy beam-columns

Scale model technology represents one method of investigating the behavior of advanced, weight-efficient composite structures under a variety of loading conditions. It is necessary, however, to understand the limitations involved in testing scale model structures before the technique can be fully utilized. These limitations, or scaling effects, are characterized. in the large deflection response and failure of composite beams. Scale model beams were loaded with an eccentric axial compressive load designed to produce large bending deflections and global failure. A dimensional analysis was performed on the composite beam-column loading configuration to determine a model law governing the system response. An experimental program was developed to validate the model law under both static and dynamic loading conditions. Laminate stacking sequences including unidirectional, angle ply, cross ply, and quasi-isotropic were tested to examine a diversity of composite response and failure modes. The model beams were loaded under scaled test conditions until catastrophic failure. A large deflection beam solution was developed to compare with the static experimental results and to analyze beam failure. Also, the finite element code DYCAST (DYnamic Crash Analysis of STructure) was used to model both the static and impulsive beam response. Static test results indicate that the unidirectional and cross ply beam responses scale as predicted by the model law, even under severe deformations. In general, failure modes were consistent between scale models within a laminate family; however, a significant scale effect was observed in strength. The scale effect in strength which was evident in the static tests was also observed in the dynamic tests. Scaling of load and strain time histories between the scale model beams and the prototypes was excellent for the unidirectional beams, but inconsistent results were obtained for the angle ply, cross ply, and quasi-isotropic beams. Results show that valuable information can be obtained from testing on scale model composite structures, especially in the linear elastic response region. However, due to scaling effects in the strength behavior of composite laminates, caution must be used in extrapolating data taken from a scale model test when that test involves failure of the structure.

Jackson, Karen E.↗

An easily implemented static condensation method for structural sensitivity analysis

A black-box approach to static condensation for sensitivity analysis is presented with illustrative examples of a cube and a car structure. The sensitivity of the structural response with respect to joint stiffness parameter is calculated using the direct method, forward-difference, and central-difference schemes. The efficiency of the various methods for identifying joint stiffness parameters from measured static deflections of these structures is compared. The results indicate that the use of static condensation can reduce computation times significantly and the black-box approach is only slightly less efficient than the standard implementation of static condensation. The ease of implementation of the black-box approach recommends it for use with general-purpose finite element codes that do not have a built-in facility for static condensation.

Gangadharan, S. N.↗