Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stacked operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a 5kW Solid Oxide Electrolysis Cell Stack

Solid oxide electrolysis cells (SOECs) are a developing technology for hydrogen production. They are promising due to their utilization of thermal energy to reduce their electricity consumption. The Department of Energy (DOE) has set goals to reduce the price per kilogram of hydrogen, and Idaho National Laboratory (INL) is conducting research to develop and demonstrate advanced methods and technologies to achieve making hydrogen a more affordable, efficient, and sustainable energy source. In this project, INL is collaborating with a vendor to evaluate and validate the design of a 5kW SOEC stack. The test aims to demonstrate a safe startup, operation, and shutdown on INL’s 5kW test stand, providing third-party validation in a different environment. A successful 50-hour test with stable hydrogen production will pave the way for a subsequent 1000-hour test. This project emphasized learning about electrolysis and the various support systems, referred to as balance of plant (BOP) equipment. These systems required modification while swapping to the vendor 5kW SOEC stack, most prominently the furnace door design and the controls system. It also included gaining skills in creating computer-aided design (CAD) drawings for the new door while using available materials and ensuring it met high-temperature requirements. Upon completion of modifications to the test stand, the SOEC will be test-fitted with respective wiring and piping. Instrumentation and piping will be checked for leaks and quality. This must be completed before the vendor’s engineers arrive to observe the test plan, startup, and a collection of 50 hours of data. The vendor’s engineers will ensure their stack performed sufficiently in the 50-hour test to enable the progression to a 1000-hour test.

08 - HYDROGEN↗

Supply Chain Binary Program Assessment Annual Report

Secure environments face a steadily increasing threat from the introduction of scientific equipment that includes extensive software components. Devices such as powerful microscopes, 3d printers, programmable logic controllers, and many others, increase our capability and scientific output. Unfortunately, they now frequently include an entire computing stack with custom software bundled along with entire operating systems. Our ability to introspect and understand binary software is extremely limited, opening up the possibility of malicious third-parties including software that compromises our critical missions.

42 ENGINEERING↗

Bringing OpenCL to Commodity RISC-V CPUs

The importance of open-source hardware has been increasing in recent years with the introduction of the RISC-V Open ISA. This has also accelerated the push for support of the open-source software stack from compiler tools to full-blown operating systems. Parallel computing with today’s Application Programming Interfaces such as OpenCL has proven to be effective at leveraging the parallelism in commodity multi-core processors and programmable parallel accelerators. However, to the best of our knowledge, there is currently no publicly available implementation of OpenCL targeting commodity RISC-V processors that is accessible to the open-source community. Besides opening RISC-V to the existing rich variety of scientific parallel applications, OpenCL also provides access to a unique genre of benchmarks useful in computer architecture research. In this work, we extended an Open-source implementation of OpenCL to target RISC-V CPUs. Our work not only cover commodity multi-core RISC-V processors, but also plethora of low- profile embedded RISC-V CPUs that often do not support atomic instructions or multi-threading.

Tine, Blaise↗

Operations and Recent Upgrades to a Tritium Recycling Facility - 20375

Nuclear Sources and Services Inc. (NSSI) is a waste handling treatment company that has been operating since 1971. In 2000, NSSI began building a 1,000 m{sup 2} (∼10,000 sqft) tritium recycling facility on the Houston, Texas premises to address a growing need in the waste disposal market. Over the years, the capability of the facility grew to address many different waste streams with the goal of recycling > 99.9% of all tritium activity back into the fusion community. This is achieved by maintaining an effluent stack release well below the 150 GBq/year (C Ci/year) operating limit and maintaining all liquid and solid waste disposal below the low-level radioactive release limit of 0.C MBq/kg (10 μCi/kg). The unique processing systems in the facility attracts many challenging contracts. Within the past two years, NSSI has engaged with customers to treat; organic mixed wastes that simultaneously contain tritium and carbon-14, safely extract tritium from large quantities of exit sign lights, and remove tritium from uncharacterised legacy depleted uranium beds from a superfund site. This paper will outline the initial testing, the system upgrades to treat these varied streams, and the progress in processing the feedstocks provided by these projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched AC-DC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

High temperature steam electrolysis↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.

25 ENERGY STORAGE↗

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN↗

NREL's 1MW Water Electrolysis Stack Performance Validation to Pilot-Scale Renewable Natural Gas Production [Slides]

NREL has designed, built, and operates a 1MW water electrolyzer balance-of-plant to support industrial partners and the U.S. Department of Energy in developing next-generation PEM stacks to reduce the cost of hydrogen production. With that hydrogen, we are developing, innovating and de-risking a biomethanation process capable of megawatt-scale deployment that upgrades biogas waste streams to produce pipeline quality renewable natural gas (RNG). Biomethanation is a two-step process using a methanogenic microorganism to convert renewable hydrogen (H 2 ) and waste carbon dioxide (CO 2 ) to renewable methane (CH 4 ) - the primary component in natural gas. Using biogenic CO 2 from biogas sources like dairies, wastewater treatment plants, and landfills allows production of this drop-in direct replacement fuel. Research projects and future R&D topics are also discussed during the presentation.

08 HYDROGEN↗

Spontaneous Polarization Suppression of Exciton–Exciton Annihilation in Rhombohedral-Stacked Bilayer Molybdenum Disulfide

Rapid exciton–exciton annihilation (EEA) in two-dimensional semiconductors limits access to high-density excitonic regimes essential for efficient optoelectronic operation under strong excitation. Here, we show that EEA is strongly suppressed in rhombohedral (3R)-stacked MoS 2 bilayers relative to nonpolar 2H bilayers, and that this suppression is quantitatively consistent with repulsive dipole–dipole interactions between layer-polarized excitons induced by spontaneous polarization. Using ultrafast pump–probe spectroscopy, we measure an EEA rate of γ EEA = (5.03 ± 0.99) × 10 –3 cm 2 s –1 in 3R bilayers, which is approximately 18.2-fold smaller than that in monolayers and 2.9-fold smaller than that in nonpolar 2H bilayers. Despite the higher exciton diffusivity recently reported for 3R relative to 2H bilayers, the reduced EEA rate in 3R indicates a rate-limited regime governed by the close-encounter annihilation probability rather than diffusion. A rate-limited annihilation model incorporating a dipole–dipole repulsive potential captures the observed ratio γ EEA,3R /γ EEA,2H ≈ 0.35 for an exciton–exciton encounter distance of ∼1.3 nm, consistent with the bilayer exciton Bohr radius. These results indicate that spontaneous polarization in 3R-stacked bilayers can suppress nonlinear excitonic losses and provide a route toward high-density excitonics.

dipolar excitons↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

An Acid-Free, Temperature-Based Cation Contamination Removal Strategy for PEM Water Electrolysis

It is widely understood that the durability and reliability of polymer electrolyte membrane (PEM) water electrolyzers are heavily dependent on feedwater purity, with cation contaminants that originate from incomplete water purification and balance of plant materials significantly harming electrolyzer performance. However, contamination remains a challenge and a common cause of failure at the stack level, indicating the need for strategies to recover the performance of contaminated cells. In this study, we investigate the effects of temperature on the uptake, electrochemical impacts, and removal of contaminant calcium and iron cations. Lower operating temperatures increase the sensitivity of the cell performance to contaminant cations, while also decreasing cation uptake and promoting contaminant removal. Computational charge transfer modelling shows that lower temperature increases the concentration of contaminant at the cathode and facilitates their removal from the cell. By testing single cells under scenarios designed to mimic stack temperature dynamics, we investigate low-temperature operation as an approach to stack-relevant contaminant recovery. Together, these results demonstrate that the low-temperature recovery approach is a promising approach for acid-free contamination recovery for PEM water electrolysis to promote stack reliability and durability.

08 HYDROGEN↗

2021 Site Environmental Report

The cover for this year’s 2021 Site Environmental Report recounts the removal of the High Flux Beam Reactor (HFBR) Stack. The Stack served as an exhaust for the Brookhaven Research Reactor (BGRR), from 1950 to 1968 and for the HFBR from 1965 to 1999. Historical operations from both facilities resulted in radiological contamination of the interior of the Stack. Under the direction of the Department of Energy (DOE), the U.S. Army Corps of Engineers oversaw the demolition and decommissioning of the HFBR Stack at BNL. Olgoonik-FPM Joint Venture was contracted to plan the work, safely dismantle the HFBR Stack, and properly dispose of all waste.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of Current-Sharing Within a REBCO Tape-Stack Cable

Current redistribution in a non-insulating REBCO tape-stack cable may enable the use of such a cable in a high field dipole without provision for transposition of the constituent tapes. As current is increased in the REBCO cable a dynamic resistance arises in the superconducting layer near operation at critical current. The critical current of each tape in the stack is determined by the local magnetic field variation within the cable. The superconducting-normal transition in REBCO occurs over a working range of current and, within that range, the longitudinal Ohmic electric field produces a transverse electric field between adjacent tapes with different critical currents. Circuit models indicate that, as a given tape approaches critical operation, current will naturally redistribute to neighboring tapes with higher current carrying capacity due to the dynamic rise in resistivity thus preventing premature quench. Here, a multi-scale model is being developed to study the dynamics of current-sharing, the limits of stability, and the impact of fluctuations in critical-current density along each tape.

43 PARTICLE ACCELERATORS↗

Advanced Computing is at the Forefront of a New “Moonshot” Revolutionizing the North American Power Grid

In the 50+ years since the first humans landed on the moon, computing has grown at breakneck speed. We are faced with another challenge that is just as daunting, and just as important to overcome-modernizing the North American electric power grid-and high-performance computing (HPC) systems with specialized software will be an important element in rising to this challenge. We describe at a high level how software developed in the ExaSGD project addresses this "moonshot" goal by utilizing exascale computing and a novel high performance solver software stack to support the mission of decarbonizing power grid operations in an environment of uncertain weather and climate. To reach the exascale benchmark the team has made a number of first-of-their-kind innovations, including novel method for stochastic optimization, fine grained parallel methods for modeling power systems, and GPU resident sparse numerical linear solvers.

17 WIND ENERGY↗