Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral responsivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗

Characteristics of infrared photodetectors produced by radiation doping.

High-energy electrons (approximately 7 MeV) were used to radiation-dope extrinsic silicon. Both n- and p-type silicon photodetectors were fabricated using this doping technique. The 500 K blackbody responsivity, spectral response, and peak detectivity were determined for these devices. The peak detectivity values measured were 4.8 Gm Hz to the 1/2 power per W at 2.15 microns for 0.1-ohm-cm n-type devices and 3.7 Gm Hz to the 1/2 power per W at 40 microns for 10-ohm-cm p-type detectors. A comparison of the thermally generated background majority carrier concentration for radiation-doped and conventional impurity-doped detectors is made.

Gross, C.↗

Development of CCD imaging sensors for space applications, phase 1

The results of an experimental investigation to develop a large area charge coupled device (CCD) imager for space photography applications are described. Details of the design and processing required to achieve 400 X 400 imagers are presented together with a discussion of the optical characterization techniques developed for this program. A discussion of several aspects of large CCD performance is given with detailed test reports. The areas covered include dark current, uniformity of optical response, square wave amplitude response, spectral responsivity and dynamic range.

Antcliffe, G. A.↗

Reference Cell Performance and Modeling on a One-Axis Tracking Surface: Preprint

Performance of five silicon-based reference cells is examined on a single-axis tracking surface. The reference cells' output are modeled using one-minute sampled spectral irradiance and reference cell temperature measurements. The model also incorporates spectral responsivity data for the reference cell. The transmission of light through the glazing multiplies the sum over all appropriate wavelengths of temperature adjusted reference cell responsivity times the measured spectral irradiance. Modeled reference cell output is compared with measured reference cell output under clear sky and totally cloudy sky conditions. For each reference cell the ratio of modeled to measured output varies by less than 2% over the year.

modeling↗

A strained silicon cold electron bolometer using Schottky contacts

We describe optical characterisation of a strained silicon cold electron bolometer (CEB), operating on a 350 mK stage, designed for absorption of millimetre-wave radiation. The silicon cold electron bolometer utilises Schottky contacts between a superconductor and an n{sup ++} doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to 160 GHz and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of 50% for radiation coupled into the device by the planar antenna and an overall noise equivalent power, referred to absorbed optical power, of 1.1×10{sup −16} W Hz{sup −1/2} when the detector is observing a 300 K source through a 4 K throughput limiting aperture. Even though this optical system is not optimized, we measure a system noise equivalent temperature difference of 6 mK Hz{sup −1/2}. We measure the noise of the device using a cross-correlation of time stream data, measured simultaneously with two junction field-effect transistor amplifiers, with a base correlated noise level of 300 pV Hz{sup −1/2} and find that the total noise is consistent with a combination of photon noise, current shot noise, and electron-phonon thermal noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular dynamics study of two-dimensional sum frequency generation spectra at vapor/water interface

Two-dimensional heterodyne-detected vibrational sum frequency generation (2D HD-VSFG) spectra at vapor/water interface were studied by molecular dynamics (MD) simulation with a classical flexible and nonpolarizable model. The present model well describes the spectral diffusion of 2D infrared spectrum of bulk water as well as 2D HD-VSFG at the interface. The effect of isotopic dilution on the 2D HD-VSFG was elucidated by comparing the normal (H{sub 2}O) water and HOD water. We further performed decomposition analysis of 2D HD-VSFG into the hydrogen-bonding and the dangling (or free) OH vibrations, and thereby disentangled the different spectral responses and spectral diffusion in the 2D HD-VSFG. The present MD simulation demonstrated the role of anharmonic coupling between these modes on the cross peak in the 2D HD-VSFG spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Developments in Tolerancing Methods for Imaging Spectrometers

We discuss detailed tolerancing methods developed for imaging spectrometers at NASA Jet Propulsion Laboratory, California Institute of Technology using the Earth Surface Mineral Dust Source Investigation (EMIT) imaging spectrometer as an illustrative example. We tolerance five metrics simultaneously: along-track response function, cross-track response function, spectral response function, spectral centroid uniformity, and spatial centroid uniformity. A method to calculate tolerancing sensitivities for each metric directly, a method to statistically combine Monte Carlo files from multiple tolerancing runs, and an example summary error budgets that communicate the key and driving tolerances for each metric are discussed. These methods facilitate rapid and semi-automated assessment of the predicted performance of imaging spectrometer systems from design through to assembly and launch life cycle, using metrics that are directly relevant to the extraction of accurate spectroscopic data from these instruments.

Mouroulis, Pantazis↗

HALOE Science Investigation

This cooperative agreement has investigated a number of spectroscopic problems of interest to the Halogen Occultation Experiment (HALOE). The types of studies performed are in two parts, namely, those that involve the testing and characterization of correlation spectrometers and those that provide basic molecular spectroscopic information. In addition, some solar studies were performed with the calibration data returned by HALOE from orbit. In order to accomplish this a software package was written as part of this cooperative agreement. The HALOE spectroscopic instrument package was used in various tests of the HALOE flight instrument. These included the spectral response test, the early stages of the gas response test and various spectral response tests of the detectors and optical elements of the instruments. Considerable effort was also expended upon the proper laboratory setup for many of the prelaunch tests of the HALOE flight instrument, including the spectral response test and the gas response test. These tests provided the calibration and the assurance that the calibration was performed correctly.

Benner, D. Chris↗

A robust pseudo-inverse spectral filter applied to the Earth Radiation Budget Experiment (ERBE) scanning channels

Computer simulations of a least squares estimator operating on the ERBE scanning channels are discussed. The estimator is designed to minimize the errors produced by nonideal spectral response to spectrally varying and uncertain radiant input. The three ERBE scanning channels cover a shortwave band a longwave band and a ""total'' band from which the pseudo inverse spectral filter estimates the radiance components in the shortwave band and a longwave band. The radiance estimator draws on instantaneous field of view (IFOV) scene type information supplied by another algorithm of the ERBE software, and on a priori probabilistic models of the responses of the scanning channels to the IFOV scene types for given Sun scene spacecraft geometry. It is found that the pseudoinverse spectral filter is stable, tolerant of errors in scene identification and in channel response modeling, and, in the absence of such errors, yields minimum variance and essentially unbiased radiance estimates.

Avis, L. M.↗

Utility of BRDF Models for Estimating Optimal View Angles in Classification of Remotely Sensed Images

Statistical classification of remotely sensed images attempts to discriminate between surface cover types on the basis of the spectral response recorded by a sensor. It is well known that surfaces reflect incident radiation as a function of wavelength producing a spectral signature specific to the material under investigation. Multispectral and hyperspectral sensors sample the spectral response over tens and even hundreds of wavelength bands to capture the variation of spectral response with wavelength. Classification algorithms then exploit these differences in spectral response to distinguish between materials of interest. Sensors of this type, however, collect detailed spectral information from one direction (usually nadir); consequently, do not consider the directional nature of reflectance potentially detectable at different sensor view angles. Improvements in sensor technology have resulted in remote sensing platforms capable of detecting reflected energy across wavelengths (spectral signatures) and from multiple view angles (angular signatures) in the fore and aft directions. Sensors of this type include: the moderate resolution imaging spectroradiometer (MODIS), the multiangle imaging spectroradiometer (MISR), and the airborne solid-state array spectroradiometer (ASAS). A goal of this paper, then, is to explore the utility of Bidirectional Reflectance Distribution Function (BRDF) models in the selection of optimal view angles for the classification of remotely sensed images by employing a strategy of searching for the maximum difference between surface BRDFs. After a brief discussion of directional reflect ante in Section 2, attention is directed to the Beard-Maxwell BRDF model and its use in predicting the bidirectional reflectance of a surface. The selection of optimal viewing angles is addressed in Section 3, followed by conclusions and future work in Section 4.

Valdez, P. F.↗

Topological signatures in nodal semimetals through neutron scattering

Abstract Topological nodal semimetals are known to host a variety of fascinating electronic properties due to the topological protection of the band-touching nodes. Neutron scattering, despite its power in probing elementary excitations, has not been routinely applied to topological semimetals, mainly due to the lack of an explicit connection between the neutron response and the signature of topology. In this work, we theoretically investigate the role that neutron scattering can play to unveil the topological nodal features: a large magnetic neutron response with spectral non-analyticity can be generated solely from the nodal bands. A new formula for the dynamical structure factor for generic topological nodal metals is derived. For Weyl semimetals, we show that the locations of Weyl nodes, the Fermi velocities and the signature of chiral anomaly can all leave hallmark neutron spectral responses. Our work offers a neutron-based avenue toward probing bulk topological materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Overall Assessment of JPSS-3 VIIRS Radiometric Performance Based on Pre-Launch Testing

Satellite imagery and data are playing an increasingly important role in scientific studies of the Earth and its climate. The scientific community has been demanding ever-increasing capabilities and accuracy from the data provided by these satellites. One key instrument on board a series of satellite platforms is the Visible Infrared Imaging Radiometer Suite (VIIRS), which provides high-quality data of the Earth from low Earth orbit covering the visible to long-wave infrared parts of the spectrum. The fourth build in the series, set to be launched on the Joint Polar-orbiting Satellite System 3 (JPSS-3) platform, has recently completed its main ground calibration program and is set to be integrated into the satellite bus in the near future. This calibration program covered a comprehensive series of performance metrics designed to demonstrate the quality of the science data and ensure the instrument can maintain its calibration successfully once on-orbit. The subject of this work covers the radiometric calibration metrics including dynamic range, signal-to-noise ratio/noise equivalent differential temperature (SNR/NEdT), polarization sensitivity, scattered light response, relative spectral response, response versus scan angle, and uniformity, as well as uncertainties; all key metrics met or exceeded their design requirements with some minor exceptions. Comparisons to previous builds will also be provided.

JPSS-3↗

Development and Operation of a Material Identification and Discrimination Imaging Spectroradiometer

Many imaging applications require quantitative determination of a scene's spectral radiance. This paper describes a new system capable of real-time spectroradiometric imagery. Operating at a full-spectrum update rate of 30Hz, this imager is capable of collecting a 30 point spectrum from each of three imaging heads: the first operates from 400 nm to 950 nm, with a 2% bandwidth; the second operates from 1.5 micro-m to 5.5 micro-m with a 1.5% bandwidth; the third operates from 5 micro-m to 12 micro-m, also at a 1.5% bandwidth. Standard image format is 256 x 256, with 512 x 512 possible in the VIS/NIR head. Spectra of up to 256 points are available at proportionately lower frame rates. In order to make such a tremendous amount of data more manageable, internal processing electronics perform four important operations on the spectral imagery data in real-time. First, all data in the spatial/spectral cube of data is spectro-radiometrically calibrated as it is collected. Second, to allow the imager to simulate sensors with arbitrary spectral response, any set of three spectral response functions may be loaded into the imager including delta functions to allow single wavelength viewing; the instrument then evaluates the integral of the product of the scene spectral radiances and the response function. Third, more powerful exploitation of the gathered spectral radiances can be effected by application of various spectral-matched filtering algorithms to identify pixels whose relative spectral radiance distribution matches a sought-after spectral radiance distribution, allowing materials-based identification and discrimination. Fourth, the instrument allows determination of spectral reflectance, surface temperature, and spectral emissivity, also in real-time. The spectral imaging technique used in the instrument allows tailoring of the frame rate and/or the spectral bandwidth to suit the scene radiance levels, i.e., frame rate can be reduced, or bandwidth increased to improve SNR when viewing low radiance scenes. The unique challenges of design and calibration are described. Pixel readout rates of 160 MHz, for full frame readout rates of 1000 Hz (512 x 512 image) present the first challenge; processing rates of nearly 600 million integer operations per second for sensor emulation, or over 2 billion per second for matched filtering, present the second. Spatial and spectral calibration of 66,536 pixels (262,144 for the 512 x 512 version) and up to 1,000 spectral positions mandate novel decoupling methods to keep the required calibration memory to a reasonable size. Large radiometric dynamic range also requires care to maintain precision operation with minimum memory size.

Dombrowski, Mark↗