Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “space needle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A new, simple electrostatic-acoustic hybrid levitator

Battelle has developed a hybrid levitator by combining the known single-axis acoustic standing wave levitator with a coaxial DC electric field. The resulting Coulomb forces on the charged liquid or solid sample support its weight and, together with the acoustic force, center the sample. Liquid samples with volumes approximately less than 100 micro-liters are deployed from a syringe reservoir into the acoustic pressure node. The sample is charged using a miniature high voltage power supply (approximately less than 20 kV) connected to the syringe needle. As the electric field, generated by a second miniature power supply, is increased, the acoustic intensity is reduced. The combination of both fields allows stable levitation of samples larger than either single technique could position on the ground. Decreasing the acoustic intensity reduces acoustic convection and sample deformation. Neither the electrostatic nor the acoustic field requires sample position sensing or active control. The levitator, now used for static and dynamic fluid physics investigations on the ground, can be easily modified for space operations.

Lierke, E. G.↗

Percutaneous aspiration of fluid for management of peritonitis in space

BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. Hypothesis: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.

Non-NASA Center↗

Observations of Non-Spherical, Graphite-Epoxy Projectiles Impacting a Thermally-Insulated, Double-Wall Shield

The DebriSat hypervelocity impact experiment, performed at the Arnold Engineering Development Center (U.S.A.F. Arnold Air Force Base), is intended to update the catastrophic break-up models for modern satellites. To this end, the DebrisSat was built with many modern materials including structural panels of carbon-fiber, reinforced polymer (CFRP). Subsequent to the experiment, fragments of the DebrisSat have been extracted from porous, catcher panels used to gather the debris from the impact event. Thus far, one of the key observations from the collected fragments is that CFRP represents a large fraction of the fragments and that these fragments tend to be thin, flake-like structures or long, needle-like structures; whereas, debris with nearly equal dimensions is less prevalent. As current ballistic-limit models are all developed based upon spherical impacting particles, the experiment has pointed to a missing component in the current approach that must be considered. To begin to understand the implications of this observation, simulations like those shown in Fig. 1 have been performed using cylindrical structures at a representative orbital speed into an externally-insulated, double-wall shield that is representative of shielding of International-Space-Station-visiting vehicles. These simulations have been performed for normal impacts to the surface with three different angles-of-attack (AOA) to capture the effect on the shield performance. This paper documents the simulated shield and the models developed to study the effect of non-spherical fragments, as well as, derives the critical characteristics of CFRP impacting particles for the selected shield as shown in Fig. 2. To assist with the design of the updated debris models, this work summarizes the simulated results into a deployable form for evaluating the relative importance of fragment structures.

Miller, Joshua E.↗

Isothermal deformation and spheroidization mechanism of (TiB + La2O3)/Ti composites with different initial structures

Highlights: • Different initial microstructures were obtained through designed heat treatment. • Refined lamellar microstructures promoted dynamic recrystallization. • The spheroidization mechanism was attributed to dynamic recrystallization. • The micron TiB and submicron La{sub 2}O{sub 3} impeded dislocation movement. (TiB + La{sub 2}O{sub 3})/Ti composites with different initial structures were obtained through designed heat treatment. The isothermal deformation and spheroidization mechanisms of (TiB + La{sub 2}O{sub 3})/Ti composites with different initial structures were investigated. Initial structures were refined as the heat treatment temperature decreased. Simultaneously, the quenching and reheating resulted in finer α lamella colonies and α interlamellar spacing compared to the furnace cooling. The flow resistance of furnace cooled samples was lower than the quenched and reheated samples in terms of flow stress data. Following the deformation at 920 °C, the furnace cooled samples demonstrated lamellar α phase and partial spheroidized structure. Moreover, the spheroidization mechanism was similar to the boundary splitting model. Recrystallized grains of approximately 1 μm in diameter were obtained in the quenched and reheated sample following deformation at 920 °C. The spheroidization mechanism was attributed to the development of finer needles through quenching and reheating, as well as to subsequent dynamic recrystallization during the hot deformation. Additionally, the dislocation movement was blocked by the reinforcements on account of the composites with micron TiB and submicron La{sub 2}O{sub 3} during the hot deformation. Furthermore, the reinforcements could facilitate the dynamic recrystallization (DRX) of the α phase.

36 MATERIALS SCIENCE↗

HTO and OBT concentrations in a wetland ecosystem

Tritiated water (HTO) and organically bound tritium (OBT) concentrations in the non-human biota inhabiting Duke Swamp were measured during the 2005 growing season. Samples of surface water, soil, plants, precipitation, wild animals and air moisture were collected from 2005 May to October at five locations in the swamp and analyzed for their tritium content. HTO concentrations in air moisture decreased with height since the tritium source is in the ground. Soil HTO concentrations were not closely related to the concentrations in nearby surface water and the HTO concentration in balsam fir needles showed no clear pattern with height. HTO concentrations in moss, grass and alder leaves decreased in September, which is the time when metabolic activity is reduced. OBT concentrations in a given compartment showed less variation than the HTO concentrations in that compartment. The OBT/HTO ratio was approximately one for soil and less than one for plants, with the exception of lichen. The OBT/HTO ratio in most wild animals was also less than one, but increased to more than 2.0 for mice. Although the tritium concentrations varied substantially in space and time in Duke Swamp, the fact that OBT/HTO <1 for most compartments suggests that equilibrium conditions hold locally. (authors)

54 ENVIRONMENTAL SCIENCES↗

Moving the needle: Employing deep reinforcement learning to push the boundaries of coarse-grained vaccine models

Highly mutable infectious disease pathogens (hm-IDPs) such as HIV and influenza evolve faster than the human immune system can contain them, allowing them to circumvent traditional vaccination approaches and causing over one million deaths annually. Agent-based models can be used to simulate the complex interactions that occur between immune cells and hm-IDP-like proteins (antigens) during affinity maturation—the process by which antibodies evolve. Compared to existing experimental approaches, agent-based models offer a safe, low-cost, and rapid route to study the immune response to vaccines spanning a wide range of design variables. However, the highly stochastic nature of affinity maturation and vast sequence space of hm-IDPs render brute force searches intractable for exploring all pertinent vaccine design variables and the subset of immunization protocols encompassed therein. To address this challenge, we employed deep reinforcement learning to drive a recently developed agent-based model of affinity maturation to focus sampling on immunization protocols with greater potential to improve the chosen metrics of protection, namely the broadly neutralizing antibody (bnAb) titers or fraction of bnAbs produced. Using this approach, we were able to coarse-grain a wide range of vaccine design variables and explore the relevant design space. Our work offers new testable insights into how vaccines should be formulated to maximize protective immune responses to hm-IDPs and how they can be minimally tailored to account for major sources of heterogeneity in human immune responses and various socioeconomic factors. Our results indicate that the first 3 to 5 immunizations, depending on the metric of protection, should be specially tailored to achieve a robust protective immune response, but that beyond this point further immunizations require only subtle changes in formulation to sustain a durable bnAb response.

60 APPLIED LIFE SCIENCES↗

Crystal growth and fluid mechanics problems in directional solidification

Broadly speaking, our efforts have been concentrated in two aspects of directional solidification: (A) a more complete theoretical understanding of convection effects in a Bridgman apparatus; and (B) a clear understanding of scalings of various features of dendritic crystal growth in the sensitive limit of small capillary effects. For studies that fall within class A, the principal objectives are as follows: (A1) Derive analytical formulas for segregation, interfacial shape and fluid velocities in mathematically amenable asymptotic limits. (A2) Numerically verify and extend asymptotic results to other ranges of parameter space with a view to a broader physical understanding of the general trends. With respect to studies that fall within class B, the principal objectives include answering the following questions about dendritic crystal growth: (B1) Are there unsteady dendrite solutions in 2-D to the completely nonlinear time evolving equations in the small surface tension limit with only a locally steady tip region with well defined tip radius and velocity? Is anisotropy in surface tension necessary for the existence of such solutions as it is for a true steady state needle crystal? How does the size of such a local region depend on capillary effects, anisotropy and undercooling? (B2) How do the different control parameters affect the nonlinear amplification of tip noise and dendritic side branch coarsening?

Tanveer, Saleh↗

Device for Locking a Control Knob

A simple, effective, easy-to-use device locks a control knob in a set position. In the initial application for which this device was conceived, the control knob to be locked is that of a needle valve. Previously, in that application, it was necessary for one technician to hold the knob to keep the valve at the desired flow setting while another technician secured the valve with safety wire -- a time-consuming procedure. After attachment of the wire, it was still possible to turn the knob somewhat. In contrast, a single technician using the present device can secure the knob in the desired position. in about 30 seconds, and the knob cannot thereafter be turned, even in the presence of harsh vibrations, which occur during space shuttle launch. The device includes a special-purpose clamp that fits around the control knob and its shaft and that can be tightened onto the knob, without turning the knob, by means of two thumbscrews. The end of the device opposite the clamp is a tang that contains a slot that, in turn, engages a bolt that protrudes from the panel on which the control knob and its shaft are mounted.

Grom, Dave↗

Filtering log data: finding the needles in the haystack

Log data is an incredible asset for troubleshooting in large-scale systems. Nevertheless, due to the ever-growing system scale, the volume of such data becomes overwhelming, bringing enormous burdens on both data storage and data analysis. To address this problem, we present a 2-dimensional online filtering mechanism to remove redundant and noisy data via feature selection and instance selection. The objective of this work is two-fold: (i) to significantly reduce data volume without losing important information, and (ii) to effectively promote data analysis. We evaluate this new filtering mechanism by means of real environmental data from the production supercomputers at Oak Ridge National Laboratory and Sandia National Laboratory. Our preliminary results demonstrate that our method can reduce more than 85% disk space, thereby significantly reducing analysis time. Moreover, it also facilitates better failure prediction and diagnosis by more than 20%, as compared to the conventional predictive approach relying on RAS (Reliability, Availability, and Serviceability) events alone.

failure prediction↗

Remote sensing of changes in morphology and physiology of trees under stress

Results of continuing studies of forest trees subjected to varying types of stress are reported. Both greenhouse and field studies are included. Greenhouse work with tree seedlings exposed to varying levels of NaCl and CaCl2 in the soil indicated that, in the initial stages, palisade cells shrink and the amount of air space in the leaf increases. As the severity of damage increases, the cells of the spongy mesophyll shrink and flatten, and the amount of air space in the leaf decreases. Statistical analysis of foliar reflectance and associated moisture content data led to a series of regression equations for predicting foliar moisture content from reflectance data. Equations were calculated for three species, yellow birch (Betula alleghaniensis Britton), sugar maple (Acer saccharum Marsh.) and white ash (Fraxinus americana L.) having multiple correlation coefficients of 0.98, 0.94 and 0.93 respectively. Interpretation of multispectral imagery of the Ann Arbor Forestry Test Site (NASA Site 190) provided evidence that infections of Fomes annosus can be detected in the early stages. Infections of two needle cast diseases were also detected in conifer plantations in the test site. A study of automatic interpretation of multispectral scanner imagery for tree species recognition provided encouraging results.

Olson, C. E., Jr.↗

C-band microwave scattering from small balsam fir

An experiment to examine the C-band backscattering characteristics of conifer trees was conducted using a truck-mounted scatterometer. Small (1 m tall) balsam fir (Abies balsamea) were arranged at various equidistant spacings on a platform to present canopies of varying density to the radar. C-band backscattering measurements of a range of canopy densities were acquired under different polarizations and incidence angles. The measured backscattering coefficient from the tree canopies increased with increasing biomass, but approached a maximum at a LAI of 2.5 and fresh biomass of 3.3 kg/sq m. A backscatter model was implemented using measured canopy attributes and showed close agreement with scatterometer measurements over the range of canopy densities. Model results indicated that branches were the prime scatterers of the radar while needles were found to only slightly attenuate the radar signal.

Ranson, K. J.↗

Microarthroscopy System With Image Processing Technology Developed for Minimally Invasive Surgery

In a joint effort, NASA, Micro Medical Devices, and the Cleveland Clinic have developed a microarthroscopy system with digital image processing. This system consists of a disposable endoscope the size of a needle that is aimed at expanding the use of minimally invasive surgery on the knee, ankle, and other small joints. This device not only allows surgeons to make smaller incisions (by improving the clarity and brightness of images), but it gives them a better view of the injured area to make more accurate diagnoses. Because of its small size, the endoscope helps reduce physical trauma and speeds patient recovery. The faster recovery rate also makes the system cost effective for patients. The digital image processing software used with the device was originally developed by the NASA Glenn Research Center to conduct computer simulations of satellite positioning in space. It was later modified to reflect lessons learned in enhancing photographic images in support of the Center's microgravity program. Glenn's Photovoltaic Branch and Graphics and Visualization Lab (G-VIS) computer programmers and software developers enhanced and speed up graphic imaging for this application. Mary Vickerman at Glenn developed algorithms that enabled Micro Medical Devices to eliminate interference and improve the images.

Steele, Gynelle C.↗

Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) in Support of Plant-Growth Systems

As the National Aeronautics and Space Association (NASA) begins to pursue long-duration space flights, they will need to be able to provide astronauts with a nutritious and reliable food source. To meet the administration’s goal of traveling to the Moon and Mars, astronauts will need to begin to grow their own food in space. To protect their food source, extensive monitoring will occur to test for the effects of a space flight environment (e.g., radiation) as well as for early pathogen and disease detection. Genomic sequencing allows for both concerns to be tested on a regular basis. However, NASA’s current sequencer is unable to process plant tissues. Therefore, a novel method for plant DNA extraction using microneedle (MN) patches that will be able to feed into NASA’s existing system, but also require minimal human input is proposed. To support this, the design was broken down into four components (1) MN patch fabrication (2) MN patch extraction, (3) automated sampling motion control, and (4) a processing module. The MN patch is fabricated using a custom mold with conically shaped needles. The mold is filled with Polyvinyl alcohol (PVA) solution and placed in a vacuum desiccator. The mold is left in the vacuum overnight until the patch is dry and ready for use. The protocol was tested with varying pressures, drying times, volume amounts, and preparation methods to determine if highquality needles can be produced. A MN is a method of DNA extraction where the patch is applied to a leaf, the needles penetrate the leaf, breaking the rigid plant cell wall to isolate the DNA. A protocol for this method of extraction was tested to ensure the patch could produce the needed yield and purity. The tests varied by the number of patches, number of applications, and plant type. To automate the MN extraction method, motion control will utilize two separate axis tables which move in the x and y directions. The y-axis table will have an end effector that fits a MN patch and will have the ability to apply the patch to the leaf sample. This end effector will also act as a lid for a downstream processing module. The other axis will position the leaf sample and processing container so that the patch can be applied accurately. The Joint Comprehensive Sequencing System (JCSS) module integrates all the components together. The output of this module feeds into the NASA Charged Information-Storage Polymer Preparation System (CHIPPS) for genomic sequencing. The extraction module operates using a series of syringes and tubing to pump the varying reagents needed for the extraction protocol. The results of the study proved that MN patches are a viable method of DNA extraction. While fabrication of high-quality needles was unsuccessful, the protocol was able to be further developed using centrifugation. The integrated design between the motion control and the JCSS enabled the potential for automation with a complete conceptual design and prototype. Future research and development for this study would include (1) further testing for fabrication (2) expanding the range of plant species compatible with the MN patch, and (3) building a working prototype for the integrated system.

Peter Ling↗

Coarsening Dynamics and Marangoni Effects in Thin Liquid Crystal Bubbles in Microgravity

The Observation and Analysis of Smectic Islands in Space (OASIS) flight hardware was successfully launched on SpaceX-6 on April 15, 2015 and was operated in the Microgravity Science Glovebox (MSG) on board the International Space Station (ISS). The OASIS project comprises a series of experiments that probe the interfacial and hydrodynamic behavior of spherical-bubble freely suspended liquid crystal (FSLC) membranes in space. These are the thinnest known stable condensed phase structures, making them ideal for studies of two-dimensional (2D) coarsening dynamics and thermocapillary phenomena in microgravity. The OASIS experimental investigation was carried out using four different smectic A and C liquid crystal materials in four separate sample chambers housed inside the MSG. In this report, we present the behavior of collective dynamics on 2D bubble surface, including the equilibrium spatial organization and interaction of islands in electric fields and temperature gradients, and the diffusion and coalescence-driven coarsening dynamics of island emulsions in microgravity. We have observed spontaneous bubble thickening behavior caused by gradients between the bubble-blowing needle and ambient air temperatures. A uniform, thicker band forms during coarsening as a result of non-uniform heating by the LED illumination panels. These are proposed to be a result of Marangoni convection on the bubble surface.

microgravity↗

TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be a useful tool in image-guided interventions for prostate-cancer diagnosis and treatment.

60 APPLIED LIFE SCIENCES↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗