Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solid scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Visible emission spectra of thermographic phosphors under x-ray excitation

Thermographic phosphors have been employed for temperature sensing in challenging environments, such as on surfaces or within solid samples exposed to dynamic heating, because of the high temporal and spatial resolution that can be achieved using this approach. Typically, UV light sources are employed to induce temperature-sensitive spectral responses from the phosphors. However, it would be beneficial to explore x-rays as an alternate excitation source to facilitate simultaneous x-ray imaging of material deformation and temperature of heated samples and to reduce UV absorption within solid samples being investigated. Here, the phosphors BaMgAl 10 O 17 :Eu (BAM), Y 2 SiO 5 :Ce, YAG:Dy, La 2 O 2 S:Eu, ZnGa 2 O 4 :Mn, Mg 3 F 2 GeO 4 :Mn, Gd 2 O 2 S:Tb, and ZnO were excited using incident synchrotron x-ray radiation. These materials were chosen to include conventional thermographic phosphors as well as x-ray scintillators (with crossover between these two categories). X-ray-induced thermographic behavior was explored through the measurement of visible spectral response with varying temperature. The incident x-rays were observed to excite the same electronic energy level transitions in these phosphors as UV excitation. Similar shifts in the spectral response of BAM, Y 2 SiO 5 :Ce, YAG:Dy, La 2 O 2 S:Eu, ZnGa 2 O 4 :Mn, Mg 3 F 2 GeO 4 :Mn, and Gd 2 O 2 S:Tb were observed when compared to their response to UV excitation found in literature. Some phosphors were observed to thermally quench in the temperature ranges tested here, while the response from others did not rise above background noise levels. This may be attributed to the increased probability of non-radiative energy release from these phosphors due to the high energy of the incident x-rays. These results indicate that x-rays can serve as a viable excitation source for phosphor thermometry.

42 ENGINEERING↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Colloidal Quantum Shells: An Emerging 2D Semiconductor for Energy Applications

Low-dimensional semiconductors hold strong promise for future energy applications. These nanomaterials are inexpensive to process and offer a broad spectrum of attractive quantum-mechanical properties. The notorious problem of low-dimensional nanostructures, however, lies in their limited performance under high energetic loads, when more than one exciton per particle is created. Multiple excitons undergo fast annihilation, causing efficiently roll-off in energy-intensive applications, including high-brightness LEDs, X-ray scintillators, and solar cells. In this prospective, we will highlight an emerging type of low-dimensional semiconductors that allows avoiding such multi-exciton (MX) energy losses. Recently demonstrated colloidal quantum shells benefit from the spatial separation of multiple excitons, which leads to extraordinary improvements to MX lifetimes and MX quantum yield. This makes quantum shell morphology an attractive candidate for solution-processed optical and electrical devices. In this Focus Review, we compare the optoelectronic properties of quantum shells against other low-dimensional semiconductors and discuss their emerging opportunities in solid-state lighting and energy-harvesting applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations and theory of X-rays and gamma-rays from radio-quiet Seyferts

Recent oriented scintillation spectrometer experiment (OSSE) observations of sift gamma-ray emission from radio-quiet Seyfert galaxies as well as their theoretical implications are reviewed. For some Seyferts, the OSSE data can be combined with X-ray data from Ginga and ROSAT. Seyfert 1s have intrinsic power-law spectra with approximately 0.9 extending without a break to at least approximately 200 keV. There is some evidence for a break at higher energies. On top of this intrinsic spectrum there is a Compton reflection component, which corresponds to cold matter covering a approximately 2 pi solid angle as seen by the power-law source. Compton reflection is responsible for a hardening of the spectrum in the approximately 5-30 keV range and a softening at approximately 30-200 keV. This spectrum is then abasorbed by a partially ionized external medium. The spectra of Seyfert 2s are marginally consistent with those of Seyfert 1s modified by strong absorption. However, there are indications that their intrinsic X-ray spectra are harder than those of Seyfert 1s. This is in fact the case for NGC 4151, a Seyfert 1.5. The Seyfert spectra integrated over redshift with cosmological evolution can explain the cosmic X-ray background spectrum from 1 to 100 keV.

Zdziuarski, A. A.↗

Effect of Mechanical Stresses on Characteristics of Chip Tantalum Capacitors

The effect of compressive mechanical stresses on chip solid tantalum capacitors is investigated by monitoring characteristics of different part types under axial and hydrostatic stresses. Depending on part types, an exponential increase of leakage currents was observed when stresses exceeded 10 MPa to 40 MPa. For the first time, reversible variations of leakage currents (up to two orders of magnitude) with stress have been demonstrated. Mechanical stresses did not cause significant changes of AC characteristics of the capacitors, whereas breakdown voltages measured during the surge current testing decreased substantially indicating an increased probability of failures of stressed capacitors in low impedance applications. Variations of leakage currents are explained by a combination of two mechanisms: stress-induced scintillations and stress-induced generation of electron traps in the tantalum pentoxide dielectric.

Teverovsky, Alexander A.↗

Optical characterization of deep-level defects in n-type Al x In y Ga 1- x - y P for the development of solid-state photomultiplier analogs

Characterizing intrinsic defects is an essential step in evaluating materials for novel optoelectronic device applications. For photomultipliers, suppressing dark currents is critical, but a tradeoff is present between maximizing the band gap while remaining sensitive to the wavelength of interest and minimizing the incorporation of fresh defects by growing not-yet-optimized alloys. We present a series of capacitance-based measurements, including deep-level optical spectroscopy, steady-state photocapacitance, and illuminated capacitance-voltage, on photodiodes with lightly n-type Al x In y Ga 1−x−y P absorber regions. Several deep levels are identified, including one near the midgap. Although the inclusion of aluminum increases each trap density by approximately 10×, the hole capture cross-section also appears to decrease, suggesting that Shockley–Read–Hall dark currents may be suppressed. These materials may be good candidates for the development into silicon photomultiplier analogs with a wider bandgap for scintillator applications.

III–V↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Hydrogen Particles and Flow Rates Analyzed for Atomic Fuels

The experiments were conducted at Glenn's Small Multipurpose Research Facility (SMIRF, ref. 5). The experimental setup was placed in the facility's vacuum tank to prevent heat leaks and subsequent boiloff of the liquid helium. Supporting systems maintained the temperature and pressure of the liquid helium bath where the solid particles were created. Solid hydrogen particle formation was tested from February 23 to April 2, 2001. Millimeter-sized solid-hydrogen particles were formed in a Dewar of liquid helium as a prelude to creating atomic fuels and propellants for aerospace vehicles. Atomic fuels or propellants are created when atomic boron, carbon, or hydrogen is stored in solid hydrogen particles. The current testing characterized the solid hydrogen particles without the atomic species, as a first step to creating a feed system for the atomic fuels and propellants. This testing did not create atomic species, but only sought to understand the solid hydrogen particle formation and behavior in the liquid helium. In these tests, video images of the solid particle formation were recorded, and the total mass flow rate of the hydrogen was measured. The mass of hydrogen that went into the gaseous phase was also recorded using a commercially available residual gas analyzer. The temperatures, pressures, and flow rates of the liquids and gases in the test apparatus were recorded as well. Testing conducted in 1999 recorded particles as small as 2 to 5 mm in diameter. The current testing extended the testing conditions to a very cold Dewar ullage gas of about 20 to 90 K above the 4 K liquid helium. With the very cold Dewar gas, the hydrogen freezing process took on new dimensions, in some cases creating particles so small that they seemed to be microscopic, appearing as infinitesimally small scintillations on the videotaped images.

Palaszewski, Bryan A.↗

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) aims to provide a broad physics program primarily addressed to probing CP violation in the neutrino sector and identifying the neutrino mass hierarchy. The search for proton decay, the observation of supernova neutrino bursts, and the investigation of solar neutrinos represent other additional goals of DUNE experiment, which can be enhanced by the use and the high performances of the Photon Detection System (PDS). Using the technology based on liquid argon Time Projection Chamber (LArTPC), the experiment plans to observe neutrino interactions inside detectors located 1300 km away from the Long Baseline Neutrino Facility (LBNF) at Fermi National Accelerator Laboratory (FNAL), where the neutrinos are produced. The experiment consists of two main parts, respectively the far and near detectors. The far site will comprise four detector modules. The first module is constituted by a vertical drift single-phase LArTPC, while the second module provides a horizontal drift single-phase LArTPC. The configurations of the other modules are still under definition. Neutrino detection in LArTPCs is achieved by identifying the charge and light generated from its interactions with liquid argon. The wire planes of the instrumented anode and the PDS detect these signals, respectively. The PDS in the first two modules, detailed in the present document, uses a modified version of the so-called ARAPUCA technology, named X-ARAPUCA. This system consisting of a highly reflecting box with an entrance window made by dichroic filters and wavelength shifters, creates a trap to detect the VUV (128 nm) scintillation photons. The X-ARAPUCA of the first module is called Supercell, and it has dimensions of 488×100 mm 2 , while Megacell is the second module version, with an active area of 60×60 cm 2 . This latter configuration also represents a significant technological advancement. Since half of the modules are placed on the cathode at high voltage, they are powered and read out using innovative power-over-fiber (PoF) and signal-over-fiber (SoF) technologies. Meanwhile, the other half are installed in a membrane behind the field cage, with a total transparency of around 70%.

Neutrino detectors↗

Performance and Reliability of Solid Tantalum Capacitors at Cryogenic Conditions

Performance of different types of solid tantalum capacitors was evaluated at room and low temperatures, down to 15 K. The effect of temperature on frequency dependencies of capacitance, effective series resistances (ESR), leakage currents, and breakdown voltages has been investigated and analyzed. To assess thermo-mechanical robustness of the parts, several groups of loose capacitors and those soldered on FR4 boards were subjected to multiple (up to 500) temperature cycles between room temperature and 77 K. Experiments and mathematical modeling have shown that degradation in tantalum capacitors at low temperatures is mostly due to increasing resistance of the manganese cathode layer, resulting in substantial decrease of the roll-off frequency. Absorption currents follow a power law, I approximately t(sup -m), with the exponent m varying from 0.8 to 1.1. These currents do not change significantly at cryogenic conditions and the value of the exponent remains the same down to 15 K. Variations of leakage currents with voltage can be described by Pool-Frenkel and Schottky mechanisms of conductivity, with the Schottky mechanism prevailing at cryogenic conditions. Breakdown voltages of tantalum capacitors increase and the probability of scintillations decreases at cryogenic temperatures. However, breakdown voltages measured during surge current testing decrease at liquid nitrogen (LN) compared to room-temperature conditions. Results of temperature cycling suggest that tantalum capacitors are capable of withstanding multiple exposures to cryogenic conditions, but the probability of failures varies for different part types.

Teverovsky, Alexander↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗