Owens-Illinois liquid solar collector materials assessment

From the beginning, it was noted that the baseline drawings for the liquid solar collector exhibited a distinct weakness concerning materials specification where elastomers, plastics, and foam insulation materials were utilized. A relatively small effort by a competent design organization would alleviate this deficiency. Based on results obtained from boilout and stagnation tests on the solar simulator, it was concluded that proof testing of the collector tubes prior to use helps to predict their performance for limited service life. Fracture mechanics data are desirable for predicting extended service life and establishing a minimum proof pressure level requirement. The temperature capability of this collector system was increased as the design matured and the coating efficiency improved. This higher temperature demands the use of higher temperature materials at critical locations in the collector.

Nichols, R. L.↗

Modular test system for solar collectors

Portable, recirculating-water-flow, and temperature-control device is used with solar simulator and actual sunlight to test and evaluate several solar-collector panel coatings, panel designs, and scaled-down collector subsystems. System can be pressurized to prevent boiling and allows operation above 100 degrees Centigrade.

Dolan, F. J.↗

Development and testing of a hot-air solar collector

Summarized report on development and testing of hot-air flat-plate solar collector includes structural details, coating selection, and spacing between coating and glass plate. Report gives complete performance specifications and extensive certifications test report.

Caudle, J. M.↗

Indoor test for thermal performance evaluation of the Solaron (air) solar collector

The test procedure used and the results obtained from an evaluation test program, conducted to obtain thermal performance data on a Solaron double glazed air solar collector under simulated conditions in a solar simulator are described. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed. The Solaron collector absorber plate is made of 24-gage steel, the coating is baked-on black paint, the cover consists of two sheets of 1/8-inch low-iron tempered glass, and the insulation is one thickness of 3 5/8-inch fiberglass batting.

Source record↗

Development of flat-plate solar collectors for the heating and cooling of buildings: Executive summary

An efficient, low cost, flat-plate solar collector was developed. Computer aided mathematical models of the heat process in the collector were used in defining absorber panel configuration; determining insulation thickness; and in selecting the number, spacing, and material of the covers. Prototypes were built and performance tested. Data from simulated operation of the collector are compared with predicted loads from a number of locations to determine the degree of solar utilization.

Source record↗

Weathering of a liquid-filled solar collector

Report describes procedures and results of tests for effects of weathering on flat-plate liquid solar collector. Thermal performance was measured before and after natural weathering for 15-1/2 months by using Marshall Space Flight solar simulator.

Source record↗

Performance evaluations of a liquid solar collector

Report presents procedures and results of thermal performance tests on single-covered liquid solar collector under simulated comditions. Test conditions and data are given in tables and graphs for stagnation tests and thermal performance test. In addition, time-constant test and incident-angle modifier test were conducted to determine transient effect and incident-angle effect. Results of collector load tests are also given.

Shih, K.↗

Final report on the concentric-tube solar collector

Report documents 26-month program to optimize performance of commercial high performance concentric tube solar collector. Report discusses program objectives, accomplishments, encountered problems, and final hardware. Certification test results are also included.

Parker, J. C.↗

Preliminary design package for Sunair SEC-601 solar collector

The preliminary design of the Owens-Illinois model Sunair SEC-601 tubular air solar collector is presented. Information in this package includes the subsystem design and development approaches, hazard analysis, and detailed drawings available as the preliminary design review.

Source record↗

Thermal performance of a hot-air solar collector

Report contains procedures and results of thermal-performance tests on double-glazed air solar collector. Four types of tests were carried out including thermal-efficiency and stagnation tests, collector time-constant tests to assess effects of transients, and incident-angle modifier tests. Data are presented in tables and as graphs and are discussed and analyzed.

Source record↗

Performance verification of an air solar collector

Procedures and results of battery of qualification tests performed by independent certification agency on commercial solar collector are presented in report. Reported results were used as basis in judging collector suitable for field installation in residential and commerical buildings.

Miller, D. C.↗

Indoor test and long-term weathering effects on the thermal performance of the solar energy system (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on a liquid solar collector are presented. The narrow flat plate collector with reflective concentrating mirrors uses water as the working fluid. The double-covered collector weighs 137 pounds and has overall dimensions of about 35" by 77" by 6.75". The test program was conducted to obtain the following information: thermal performance data under simulated conditions, structural behavior under static load, and the effects of long term exposure to natural weathering.

Source record↗

Thermal performance of honeywell double covered liquid solar collector

The test procedures and results obtained during an evaluation test program to determine the outdoor performance characteristics of the Honeywell liquid solar collector are presented. The program was based on the thermal evaluation of a Honeywell double covered liquid solar collection. Initial plans included the simultaneous testing of a single covered Honeywell collector. During the initial testing, the single covered collector failed due to leakage; thus, testing continued on the double covered collector only. To better define the operating characteristics of the collector, several additional data points were obtained beyond those requested.

Losey, R.↗

Performance evaluation of a liquid solar collector

Report describes thermal performance and structural-load tests on commercial single glazed flat-plate solar collector with gross area of 63.5 sq ft that uses water as heat-transfer medium. Report documents test instrumentation and procedures and presents data as tables and graphs. Results are analyzed by standard data-reduction methods.

Source record↗

Thermal performance evaluation of the Calmac (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the S. N. 1, (liquid) solar collector are presented. The flat plate collector uses water as the working fluid. The absorber plate is aluminum with plastic tubes coated with urethane black. The glazing consists of .040 in fiberglass reinforced polyester. The collector weight is 78.5 pounds with overall external dimensions of approximately 50.3in. x 98.3in. x 3.8in. The following information is given: thermal performance data under simulated conditions, structural behavior under static loading, and the effects of long term exposure to natural weathering. These tests were conducted using the MSFC Solar Simulator.

Usher, H.↗