Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft X-ray imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

123 records · Page 7

Universal chemomechanical design rules for solid-ion conductors to prevent dendrite formation in lithium metal batteries

Dendrite formation during electrodeposition while charging lithium metal batteries compromises their safety. Although high-shear-modulus ( G s ) solid-ion conductors (SICs) have been prioritized to resolve the pressure-driven instabilities that lead to dendrite propagation and cell shorting, it is unclear whether these or alternatives are needed to guide uniform lithium electrodeposition, which is intrinsically density-driven. Here, we show that SICs can be designed within a universal chemomechanical paradigm to access either pressure-driven dendrite-blocking or density-driven dendrite-suppressing properties, but not both. This dichotomy reflects the competing influence of the SIC’s mechanical properties and the partial molar volume of Li + $(V_{\mathrm{Li}^+})$ relative to those of the lithium anode ( G Li and V Li ) on plating outcomes. Within this paradigm, we explore SICs in a previously unrecognized dendrite-suppressing regime that are concomitantly ‘soft’, as is typical of polymer electrolytes, but feature an atypically low $(V_{\mathrm{Li}^+})$ that is more reminiscent of ‘hard’ ceramics. Li plating (1 mA cm -2 ; T = 20 °C) mediated by these SICs is uniform, as revealed using synchrotron hard X-ray microtomography. As a result, cell cycle life is extended, even when assembled with thin Li anodes (~30 µm) and either high-voltage NMC-622 cathodes (1.44 mAh cm -2 ) or high-capacity sulfur cathodes (3.02 mAh cm -2 ).

25 ENERGY STORAGE↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Topology-dependent stability of vortex-antivortex structures

The non-trivial topology of magnetic structures such as vortices and skyrmions is considered as a key concept to explain the stability of those structures. The stability, dictated by non-trivial topology, provides great potential for device applications. Although it is a very critical scientific and technological issue, it is elusive to experimentally study the topology-dependent stability owing to the difficulties in establishing stably formed magnetic structures with different topologies. Here, we establish a platform for vortex-antivortex structures with different topological charges within Ni 80 Fe 20 rectangular elements thick enough to stabilize a unique three-dimensional magnetic structure with non-uniform magnetization along the thickness of the elements. The detailed magnetization configurations of the three-dimensional vortex-antivortex structures and their annihilations during their field-driven motions are investigated by utilizing magnetic transmission soft x-ray microscopy and micromagnetic simulation. We demonstrate that the stability of vortex-antivortex structures significantly depends on their topologies and the topology-dependent stability is associated with their different annihilation mechanisms. Furthermore, we believe that this work provides in-depth insight into the stability of magnetic structures and its topology dependence.

36 MATERIALS SCIENCE↗

Pair Cascades in Magnetar Magnetospheres

Resonant inverse Compton scattering (RICS) of soft thermal photons by relativistic particles on closed magnetic field loops has been proposed to explain the hard emission observed up to and beyond 200 keV from magnetars. If particles injected at the base of the loops have Lorentz factors ≳10 2 , the RICS spectra will be attenuated by both one-photon pair production and photon splitting in the ultrastrong magnetar fields, producing additional spectral components from pair synchrotron radiation and split photons that produce further generations of pairs and split photons. We investigate such cascades initiated by the primary injected electrons through a Monte Carlo simulation, and study the cascade spectra and pair distributions. For most observer angles, the pair synchrotron and split-photon spectra dominate the RICS primary spectra and produce complex polarization signals. In particular, the synchrotron spectra are highly polarized with degree 40%–80%, are softer than the RICS spectra, and may account for the high polarization of some magnetar spectra observed by the Imaging X-ray Polarimetry Explorer above 3 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

A coded aperture microscope for X-ray fluorescence full-field imaging

The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

36 MATERIALS SCIENCE↗

Simulation-guided analysis of resonant soft X-ray scattering for determining the microstructure of triblock copolymers

Resonant soft X-ray scattering (RSoXS) probes structure with chemical sensitivity that is useful for determining the morphology of multiblock copolymers. However, the hyperspectral scattering data produced by this technique can be challenging to interpret. Here, in this study, we use computational scattering simulations to extract the microstructure of a model triblock copolymer from the energy-dependent scattering from RSoXS. An ABC triblock terpolymer formed from poly(4-methylcaprolactone) (P4MCL), poly(2,2,2-trifluoroethylacrylate) (PTFEA), and poly (dodecylacrylate) (PDDA), P4MCL-block-PTFEA-block-PDDA, was synthesized as the model triblock system. Through quantitative evaluation of simulated scattering data from a physics-informed set of candidate structure models against experimental RSoXS data, we find the best agreement with hexagonally packed core–shell cylinders. This result is also consistent with electron-density reconstruction from hard X-ray scattering data evaluated against electron-density maps generated with the same model set. These results demonstrate the utility of simulation-guided scattering analysis to study complex microstructures that are challenging to image by microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed laser synthesis of mesoporous metal chalcogenide thin films

Mesoporous films of the metal chalcogenide B-FeSe were grown on MgO substrates by KrF pulsed laser deposition (PLD) in an argon background. At 100 mTorr, gated intensified charge-coupled device imaging and ion probe measurements showed that the plasma plume responsible for crystal growth initially comprised three components, with distinct expansion velocities. Plume interactions with the substrate heater and ablation target gave rise to complex dynamics, including collisions between the charged leading edge—rebounding between the substrate and the target—and slower-moving species in the plume interior. Film growth was dominated by species with kinetic energies ≤0.5 eV/atom. X-ray reflectivity revealed that films grown in this environment—with a substrate temperature of 350 ° C, a laser fluence of 1.0 J cm −2 , and a 7.5 mm 2 spot area—formed a porous framework with 15% porosity. Atomic force microscopy showed surface features that suggest pore sizes below 100 nm. X-ray diffraction indicated that the porous films were epitaxial with respect to the substrate and likely grew by oriented-attachment of gas-phase molecular clusters or very small nanoparticles, in contrast to the conventional epitaxy of vacuum films from atomic constituents. The in-plane orientation of the mesoporous films was B-FeSe [100]||[110] MgO, attributed to the soft landing of pre-formed crystallites on the MgO substrates, where protruding Se rows of B-FeSe aligned with corrugations of the MgO surface. In conclusion, this work implies that growth of candidate electrocatalyst materials by PLD in inert gas background may allow mesoporous frameworks with a single crystallographic orientation that expose specific crystal facets for electrochemical reactions and active site engineering.

cluster epitaxy↗

The 100-month Swift catalogue of supergiant fast X–ray transients

Supergiant fast X-ray transients (SFXTs) are high mass X-ray binaries (HMXBs) displaying X-ray outbursts that can reach peak luminosities up to 10 38 erg s -1 and spend most of their lives in more quiescent states with luminosities as low as 10 32 -10 33 erg s -1 . During the quiescent states, less luminous flares are also frequently observed with luminosities of 10 34 -10 35 erg s -1 . The main goal of the comprehensive and uniform analysis of the SFXT Swift triggers presented in this paper is to provide tools to predict whether a transient that has no known X-ray counterpart may be an SFXT candidate. These tools can be exploited for the development of future missions exploring the variable X-ray sky through large field-of-view instruments. We examined all available data on outbursts of SFXTs that triggered the Swift/Burst Alert Telescope (BAT) collected between 2005 August 30 and 2014 December 31, in particular those for which broad-band data, including the Swift/X-ray Telescope (XRT) data, are also available. This work complements and extends our previous catalogue of SFXT flares detected by BAT from 2005 February 12 to 2013 May 31, since we now include the additional BAT triggers recorded until the end of 2014 (i.e. beyond the formal first 100 months of the Swift mission). Due to a change in the mission’s observational strategy, virtually no SFXT triggers obtained a broad-band response after 2014. We processed all BAT and XRT data uniformly by using the Swift Burst Analyser to produce spectral evolution dependent flux light curves for each outburst in the sample. The BAT data allowed us to infer useful diagnostics to set SFXT triggers apart from the general γ-ray burst population, showing that SFXTs uniquely give rise to image triggers and are simultaneously very long, faint, and ‘soft’ hard-X-ray transients. We find that the BAT data alone can discriminate very well the SFXTs from other classes of fast transients, such as anomalous X-ray pulsars and soft gamma repeaters. On the contrary, the XRT data collected around the time of the BAT triggers are shown to be decisive for distinguishing SFXTs from, for instance, accreting millisecond X-ray pulsars and jetted tidal disruption events. The XRT observations of 35 (out of 52 in total) SFXT BAT triggers show that in the soft X-ray energy band, SFXTs display a decay in flux from the peak of the outburst of at least three orders of magnitude within a day and rarely undergo large re-brightening episodes, favouring in most cases a rapid decay down to the quiescent level within three to five days (at most).

79 ASTRONOMY AND ASTROPHYSICS↗

Polarized imaging of visible synchrotron emission from runaway electron plateaus in DIII-D

A new approach to estimate the pitch angle of highly energetic postdisruption runaway electrons is presented by imaging the polarized runaway electron synchrotron emission. The vertical to horizontal polarization ratio is found to range between 3 and 14 in image-average studies looking at repeated shots as well as the polarization in a single discharge. Numerical studies with guiding center and full orbit simulations performed with the SOFT and KORC codes are given and compared to the experiment. The pitch angle evolution analyzed using a 1D impurity diffusion model in combination with kinetic simulations is also presented. Furthermore, these studies find agreement in the magnitude of the pitch angle, but not in the temporal rate of change of pitch angle. The measured pitch angle evolution timescale of order 50 ms falls between a modeled timescale of 20 ms in an equilibrium model and >>100 ms in a nonequilibrium model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

Tutorial: Machine-Learning-Based CREASE-2D Analysis of 2D SAXS Profiles to Characterize Anisotropic Nanostructures in Soft Materials

We present a tutorial to guide users on how to extend the Computational Reverse Engineering Analysis of Scattering Experiments-2D (CREASE-2D) framework to interpret their experimental two-dimensional small-angle scattering (SAS) data from soft materials (e.g., polymers, peptide amphiphiles, biomolecular fibrils). Unlike most traditional SAS analysis approaches, which typically rely on azimuthally averaged onedimensional (1D) profiles, CREASE-2D utilizes the complete 2D scattering profile to reveal information about anisotropy in the structure. In past applications, CREASE has provided insights into complex structural features, including the cross-sectional shapes of assembled nanostructures and dispersity in these features, which are difficult to discern with existing analytical models. While (1D- ) CREASE has been applied to SANS and SAXS data, this tutorial shares the steps for implementing CREASE-2D using an example of a dipeptide solution system, for which we have SAXS data. We present details for these steps involved in using CREASE-2D to interpret SAXS profiles: how to preprocess SAXS data, define relevant structural features, generate three-dimensional real-space structures for specific values of these features, train a machine learning (ML) surrogate model to predict scattering profiles for given structural features, and optimize these features using genetic algorithms (GA). Then, we use these steps to interpret complex 2DSAXS data collected from dipeptide solutions that, in microscopy images, exhibit nanoscale structures that could be elliptical tubes/ flat tapes/cylinders or a combination of these cross sections. Open-source codes, computational hardware, and software requirements, as well as the strengths and limitations of this protocol, are also presented. We expect researchers working with (soft) biomaterials, peptide amphiphiles, amphiphilic polymer solutions, polymer nanocomposites, and blends of particles/polymers will find this CREASE-2D method and this tutorial of use.

CREASE↗

CALET Search for Electromagnetic Counterparts of Gravitational Waves during the LIGO/Virgo O3 Run

The CALorimetric Electron Telescope (CALET) on the International Space Station consists of a high-energy cosmic-ray CALorimeter (CAL) and a lower-energy CALET Gamma-ray Burst Monitor (CGBM). CAL is sensitive to electrons up to 20 TeV, cosmic-ray nuclei from Z = 1 through Z ~ 40, and gamma rays over the range 1 GeV–10 TeV. CGBM observes gamma rays from 7 keV to 20 MeV. The combined CAL-CGBM instrument has conducted a search for gamma-ray bursts (GRBs) since 2015 October. We report here on the results of a search for X-ray/gamma-ray counterparts to gravitational-wave events reported during the LIGO/Virgo observing run O3. No events have been detected that pass all acceptance criteria. We describe the components, performance, and triggering algorithms of the CGBM—the two Hard X-ray Monitors consisting of LaBr 3 (Ce) scintillators sensitive to 7 keV–1 MeV gamma rays and a Soft Gamma-ray Monitor BGO scintillator sensitive to 40 keV–20 MeV—and the high-energy CAL consisting of a charge detection module, imaging calorimeter, and the fully active total absorption calorimeter. The analysis procedure is described and upper limits to the time-averaged fluxes are presented.

79 ASTRONOMY AND ASTROPHYSICS↗