SEARCH · Engineering Papers
Results for “soft”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Elastic and conformational softness of a globular protein
Flexibility, or softness, is crucial for protein function and consists of a conformational component, involving jumps between potential wells, and an elastic component, involving fluctuations within the wells. Combining molecular dynamics simulation with incoherent neutron scattering and light scattering measurements on green fluorescent protein, we reveal a relationship between the intrawell fluctuations and elastic moduli of the protein. In conclusion, this finding leads to a simple means of experimentally separating the conformational from the elastic atomic displacements.
Finite-Temperature Hydrogen Adsorption and Desorption Thermodynamics Driven by Soft Vibration Modes
Not Available
High-power few-cycle Cr:ZnSe mid-infrared source for attosecond soft x-ray physics
The development of mid-infrared, high-energy pulses of extremely short pulse duration is of great importance to the strong-field physics community, as it enables extension of the high-harmonic cutoff towards the keV range of photon energies. Here we demonstrate a C r 2 + : Z n S e laser amplifier delivering 7 mJ, 100 fs pulses at 1 kHz repetition rate and 2.4 µm central wavelength with excellent energy stability and beam quality. These pulses are post-compressed to 39 fs, 6.2 mJ, and 115 GW peak power in a novel nonlinear compression scheme. The laser system was used to generate coherent soft x-ray radiation up to 0.6 keV covering the entire water window, which is of high importance for bio-relevant applications. The obtained results open a wide range of applications in nonlinear optics, attosecond and strong-field physics, and remote sensing.
Research Performance Progress Report - DOE Solar Program, Soft Costs, National Lab Projects: Promotion of PV Soft Cost Reductions in the Southeastern US
Beginning in 2014, the installed solar capacity in South Carolina (SC) grew from less than 20 megawatts to more than 300 megawatts today. Concurrently, the number of customer-sited, load-centered solar generation is expected to grow from less than 500 statewide to as many as 10,000 by 2021. This growth is the direct result of a landmark state policy initiative, Act 236, passed by the South Carolina General Assembly and signed into law by the Governor in June of 2014. Today, local policy makers in South Carolina are ill-equipped to handle the onslaught of solar permitting and zoning requests expected to come with such quick growth of an emerging market. Similarly, the state’s building inspectors, first responders, and tax assessors know little about photovoltaic (PV) technology and best practices. Finally, South Carolina’s workforce and workforce trainers continue to be underprepared to benefit from the tremendous opportunity created by the passage of Act 236. Each of these deficits in knowledge of and preparedness for solar PV translates into higher “soft costs” of installed solar PV in South Carolina.
Soft actuators and soft actuating devices
A soft buckling linear actuator is described, including: a plurality of substantially parallel bucklable, elastic structural components each having its longest dimension along a first axis; and a plurality of secondary structural components each disposed between and bridging two adjacent bucklable, elastic structural components; wherein every two adjacent bucklable, elastic structural components and the secondary structural components in-between define a layer comprising a plurality of cells each capable of being connected with a fluid inflation or deflation source; the secondary structural components from two adjacent layers are not aligned along a second axis perpendicular to the first axis; and the secondary structural components are configured not to buckle, the bucklable, elastic structural components are configured to buckle along the second axis to generate a linear force, upon the inflation or deflation of the cells. Methods of actuation using the same are also described.
Soft actuators and soft actuating devices
A soft buckling linear actuator is described, including: a plurality of substantially parallel bucklable, elastic structural components each having its longest dimension along a first axis; and a plurality of secondary structural components each disposed between and bridging two adjacent bucklable, elastic structural components; wherein every two adjacent bucklable, elastic structural components and the secondary structural components in-between define a layer comprising a plurality of cells each capable of being connected with a fluid inflation or deflation source; the secondary structural components from two adjacent layers are not aligned along a second axis perpendicular to the first axis; and the secondary structural components are configured not to buckle, the bucklable, elastic structural components are configured to buckle along the second axis to generate a linear force, upon the inflation or deflation of the cells. Methods of actuation using the same are also described.
Soft-Collinear Gravity and Soft Theorems
Explore the source record for details and available documents.
Magnetic imaging with full-field soft X-ray microscopies
Explore the source record for details and available documents.
Soft x-ray measurements using photoconductive type-IIa and single-crystal chemical vapor deposited diamond detectors
Photoconductive detectors (PCDs) are routinely used alongside vacuum x-ray diodes (XRDs) to provide an alternative x-ray flux measurement at laser facilities such as HELEN at AWE Aldermaston, UK, and Omega at the Laboratory for Laser Energetics. To evaluate diamond PCDs as an alternative to XRD arrays, calibration measurements made at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory are used to accurately calculate the x-ray flux from a laser-heated target. This is compared to a flux measurement using the Dante XRD diagnostic. Estimates indicate that the photoinduced conductivity from measurements made at Omega are too large, and calculations using the radiometric calibrations made at the NSLS agree with this hypothesis. High-purity, single-crystal, chemical vapor deposited (CVD) diamond samples are compared to natural type-IIa PCDs and show promising high resistivity effects, the corollary of which preliminary results show is a slower response time.
Calibration of a flat field soft x-ray grating spectrometer for laser produced plasmas
We have calibrated the x-ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL and at both the Omega and Omega EP lasers at the University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range of {approx}6-60 A. The calibration results presented here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from the hydrogenlike and heliumlike ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x-ray intensities recorded by the VSG to those simultaneously recorded by an x-ray microcalorimeter spectrometer.
Soft x-ray backlighting of cryogenic implosions using a narrowband crystal imaging system (invited)
A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si He{sub α} line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 μm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.
Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range
We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.
Non-axisymmetric equilibrium reconstruction of a current-carrying stellarator using external magnetic and soft x-ray inversion radius measurements
Non-axisymmetric free-boundary equilibrium reconstructions of stellarator plasmas are performed for discharges in which the magnetic configuration is strongly modified by ohmically driven plasma current. These studies were performed on the compact toroidal hybrid device using the V3FIT reconstruction code with a set of 50 magnetic diagnostics external to the plasma. With the assumption of closed magnetic flux surfaces, the reconstructions using external magnetic measurements allow accurate estimates of the net toroidal flux within the last closed flux surface, the edge safety factor, and the plasma shape of these highly non-axisymmetric plasmas. Lastly, the inversion radius of standard saw-teeth is used to infer the current profile near the magnetic axis; with external magnetic diagnostics alone, the current density profile is imprecisely reconstructed.
FERMI DETECTION OF {gamma}-RAY EMISSION FROM THE M2 SOFT X-RAY FLARE ON 2010 JUNE 12
The Geostationary Operational Environmental Satellite (GOES) M2-class solar flare, SOL2010-06-12T00:57, was modest in many respects yet exhibited remarkable acceleration of energetic particles. The flare produced an {approx}50 s impulsive burst of hard X- and {gamma}-ray emission up to at least 400 MeV observed by the Fermi Gamma-ray Burst Monitor and Large Area Telescope experiments. The remarkably similar hard X-ray and high-energy {gamma}-ray time profiles suggest that most of the particles were accelerated to energies {approx}>300 MeV with a delay of {approx}10 s from mildly relativistic electrons, but some reached these energies in as little as {approx}3 s. The {gamma}-ray line fluence from this flare was about 10 times higher than that typically observed from this modest GOES class of X-ray flare. There is no evidence for time-extended >100 MeV emission as has been found for other flares with high-energy {gamma}-rays.