Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “smps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Characterizing the performance of a POPS miniaturized optical particle counter when operated on a quadcopter drone

We first validate the performance of the Portable Optical Particle Spectrometer (POPS), a small light-weight and high sensitivity optical particle counter, against a reference scanning mobility particle sizer (SMPS) for a month-long deployment in an environment dominated by biomass burning aerosols. Subsequently, we examine any biases introduced by operating the POPS on a quadcopter drone, a DJI Matrice 200 V2. We report the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when mounted on the UAV and operating on the ground and when hovering at 10 m. When wind speeds are low (less than 2.6 m s –1 ), we find only modest differences in the RMSDs and MADs of 5 % and 3 % when operating at 10 m altitude. When wind speeds are between 2.6 and 7.7 m s –1 the RMSDs and MADs increase to 26.2 % and 19.1 %, respectively, when operating at 10m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10 m altitude, while differences in the coarse mode (here defined by d > 1 µm) are universally larger. Our results suggest that the impact of the UAV rotors on the POPS PNCs are small at low wind speeds, but when operating under a higher wind speed of up to 7.6 m s –1 , larger discrepancies occur. In addition, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.

47 OTHER INSTRUMENTATION↗

Fast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)

New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth's radiative balance as it produces roughly half of global cloud condensation nuclei. However, the time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub-3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods was tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPSs) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.

Cheng, Darren [Carnegie Mellon Univ., Pittsburgh, ↗

Ozone and aerosol size distribution measurements at the Oliktok Point, AK AMF3

Aerosol size distribution measurements at the Oliktok Point, AK AMF3 as measured by a TSI model 3082 scanning mobility particle sizer (SMPS), and ozone measurements at the Oliktok Point, AK AMF3 as measured by a 2B model 205 ozone monitor. 2B specifies a limit of detection (2σ) of 2 ppb and these data were calibrated using a 2B model 306 ozone calibration source. Users of the data are asked to contact PI Pratt prior to use for consultation, discussion of co-authorship, and to ensure that the most up-to-date information is provided.

54 ENVIRONMENTAL SCIENCES↗

Southern Great Plains Merged and Extended Cloud Condensation Nuclei Data

This data set contains best-estimate cloud condensation nuclei (CCN) spectra for five years of data (2009-2013) at the DOE Atmospheric Radiation Measurement Southern Great Plains (SGP) observatory at 45-minute time resolution. All CCN spectra span a wide SSw range, 0.0001% to ~30%, which is not measurable by CCN instrumentation alone. This product has been constructed by combining merged aerosol size distribution data (Marinescu, Peter, and Levin, Ezra. SGP Merged Aerosol Size Distribution (CPC+SMPS+APS). United States: N. p., 2019. Web. doi:10.5439/1511037 discussed in: Marinescu, PJ, EJT Levin, D Collins, SM Kreidenweis, and SC van den Heever. 2019. "Quantifying Aerosol Size Distributions and Their Temporal Variability in the Southern Great Plains, USA." Atmospheric Chemistry and Physics 19(18): 11985–12006, https://doi.org/10.5194/acp-19-11985-2019) with measurements of aerosol hygroscopicity from the humidified tandem differential mobility analyzer (HTDMA) and measured CCN distributions over a limited water supersaturation (SSw) range. Nephelometer and aerosol chemical speciation monitor (ACSM) data are used to resolve discrepancies between the above measurements, and as quality control measures.

54 ENVIRONMENTAL SCIENCES↗

mergedsmpsaps

Merged aerosol particle size distributions for the Aerodynamic Particle Sizer (APS) and Scanning Mobility Particle Sizer (SMPS) instruments

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - Tracegases

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - APS

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - SP2

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - SPAMS

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - CAPS-SSA

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - PASS

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

TRACER-CAT-LANL Aerosol Optics and Chemical Speciation - CCN

Aerosol size distribution, optical properties, and speciation data collected in La Port TX, during TRACER-CAT-LANL, July 2022, with basic trace gas measurements. All sampling was conducted with an identical aerosol inlet as the standard ARM-AOS systems. The TRacking Aerosol Convection interactions ExpeRiment Carbonaceous Aerosols Thrust by Los Alamos National Laboratory (TRACER-CAT-LANL, July 2022) was designed to complement the larger ARM TRACER science goals to understand convective cloud lifecycles and aerosol-convection interactions. TRACER-CAT-LANL is focused on understanding the relationship between particle composition and light absorption and the influence of water uptake on this relationship. This aerosol and trace gas data can be used to understand the relationship between particle composition and light absorption and the influence of water uptake on this relationship. Instruments Include: Picarro GHG Photoacoustic Soot Spectrometer (PASS-3) Humidified-cavity attenuated phase shift-single scattering albedo particulate matter monitor (H-CAPS-PMSSA) Soot Particle Aerosol Mass Spectrometer (SPAMS) Single-Particle Soot Photometer (SP2) Cloud Condensation Nuclei Counter (CCNc) Aerodynamic Particle Sizer (APS) Scanning Mobility Particle Sizer (SMPS)

54 ENVIRONMENTAL SCIENCES↗

aafsmps (b1)

The scanning mobility particle sizer (SMPS) is a particle size spectrometer that measures the aerosol number size distribution by sizing particles based on their electrical mobility diameter using a differential mobility analyzer (DMA) and by counting particles using a condensation particle counter (CPC). It measures aerosol concentration and aerosol particle size distribution in the Aitken mode range.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗