U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Technology Commercialization Awardee: EWT Americas Inc.

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by EWT Americas, Inc., for technology commercialization. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NREL on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2024 Inverter Listing Awardee: Eocycle America Corporation

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Eocycle America Corporation for Inverter Listing. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NLR on behalf of DOE, CIP helps advance wind energy as a cost-effective, distributed generation technology option.

17 WIND ENERGY↗

U.S. Department of Energy Competitiveness Improvement Project 2024 Technology Commercialization Awardee: Intelligent Energy Systems

This fact sheet describes the 2024 Competitiveness Improvement Project (CIP) award received by Intelligent Energy Systems for technology commercialization. The U.S. Department of Energy's (DOE's) CIP awards cost-shared subcontracts and technical support to manufacturers of small and medium-sized wind turbines. Managed by NLR on behalf of DOE's Wind Energy Technologies Office, CIP helps advance wind energy as a cost-effective, distributed-generation technology option.

17 WIND ENERGY↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part II: Statistical Downscaling

Abstract Capacity factors (CFs) derived from daily expected power at 22 operating wind farms in different regions of North America are used as predictands to train statistical downscaling algorithms using output from ERA5. The statistical downscaling models are then used to make CF projections for a suite of CMIP6 Earth System Models (ESMs). Downscaling is performed using a hybrid statistical approach that employs synoptic types derived using k -means clustering applied to sea level pressure fields with variance corrections applied as a function of the pressure gradient intensity. ESMs exhibit marked variability in terms of the skill with which the frequency of synoptic types and pressure gradients are reproduced relative to ERA5, and that differential skill is used to infer differential credibility in the associated CF projections. Projections of median annual mean CF [P50(CF)] in each 20-yr period from 1980 to 2099 show evidence of declines at most wind farms except in parts of the southern Great Plains, although the magnitude of the changes is strongly dependent on the ESM. For example, P50(CF) in 2080–99 deviate from those in 1980–99 by from −3.1 to +0.2 percentage points in the Northeast. The largest-magnitude declines in P50(CF) ranging from −3.9 to −2 percentage points are projected for the southern West Coast. CF trends exhibit marked seasonality and are strongly linked to changes in the relative intensity of future synoptic patterns, with much less impact from shifts in the occurrence of synoptic types over time. Internal climate modes continue to play a significant role in inducing interannual variability in wind power production, even under high radiative forcing scenarios. Significance Statement We describe how future climate changes may affect wind resources and wind power generation. Near-term changes in projected wind power electricity generation potential at operating wind farms over North America are small, but by the end of the current century electricity production is projected to decrease in many areas but may increase in parts of the southern Great Plains. The amount of change in projected wind power production is a strong function of the Earth system model that is downscaled and also depends on the continued presence of internally forced climate variability. An additional dependence on the amount of greenhouse gas–induced global warming indicates the transition of the energy sector to low-carbon sources may assist in maintaining the abundant U.S. wind resource.

Meteorology & Atmospheric Sciences↗

Climate change impacts on the energy system: a model comparison

Increasing renewable energy use is an essential strategy for mitigating climate change. Nevertheless, the sensitivity of renewable energy to climatic conditions means that the energy system’s vulnerability to climate change can also become larger. In this research, we used two integrated assessment models and data from four climate models to analyse climate change impacts on primary energy use at a global and regional scale under a low-level (RCP2.6) and a medium-level (RCP6.0) climate change scenario. The impacts are analysed on the energy system focusing on four renewable sources (wind, solar, hydropower, and biomass). Globally, small climate impacts on renewable primary energy use are found in both models (5% for RCP2.6 and 6% for RCP6.0). These impacts lead to a decrease in the use of fossil sources for most regions, especially for North America and Europe under the RCP60 scenario. Overall, IMAGE and GCAM provide a similar signal impact response for most regions. E.g. in Asia (excluding China and India), climate change induces an increase in wind and hydropower use under the RCP6.0 scenarios; however, for India, a decrease in solar energy use can be expected under both scenarios and models.

54 ENVIRONMENTAL SCIENCES↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗

Modeling and control of nuclear–renewable integrated energy systems: Dynamic system model for green electricity and hydrogen production

The need for decarbonization and diversification of energy resources has led to the development of integrated energy systems (IESs), where multiple resources supply more than one energy sector. Here, one such IES with small modular nuclear reactors and renewables (wind and solar) as generating resources, catering to the demand of the electric grid while producing hydrogen for industries, is modeled in this paper. The physics-based component models are represented using the Modelica language and interconnected to form the IES. The control and coordination of the overall system are ensured by designing a suitable control architecture composed of individual subsystem-level controls and supervisory control. The dynamic performance and the load-following capability of the IES are evaluated, while satisfying the safe operational limits of the components. Different configurations and modes of IES operation are considered, where the adaptability of the control system in the presence of varying demands and renewable generations is validated. The simulation results indicate that hydrogen as a flexible load facilitates the supply of varying grid demand. Additionally, the renewables are also accommodated into the IES owing to the flexibility of the balance of plant associated with the nuclear reactors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mapping and Characterizing the Visual Impacts of the Existing US Wind Turbine Fleet

Visual impacts of wind turbines have been a persistent concern for wind energy development in the United States (US) for decades and remain a major source of project delays and cancellations. Assessments of visual impacts are frequently performed at a local scale for individual projects, but a comprehensive understanding of broader geographic patterns in visual impacts across the US is lacking. This paper presents a visual impact assessment of the existing land-based wind turbine fleet of the contiguous United States (CONUS). The assessment combines geographic information systems and 3D simulation methods to account for key factors driving the visual magnitude of impacts from the installed turbines. The results indicate that, despite the deployment of approximately 70,000 turbines and over 144 gigawatts of land-based wind in the CONUS, the visual impacts are very small when measured as a proportion of land area, population, and sensitive visual resources. Nonetheless, visual impacts are not evenly distributed: people experience a concentrated share in a small number of natural settings, primarily including plains, prairies, and deserts. Finally, we find that although increased density of wind development consistently leads to visual impacts across a greater proportion of land, it does not always lead to impacts to a greater share of the population. These findings suggest that visual impacts from wind energy are generally well-mitigated across the CONUS to date but also highlight the need for a deeper understanding of landscape sensitivity and individual perceptions of wind turbines in the most heavily impacted natural settings.

3D simulation↗

Load assessment of a wind farm considering negative and positive yaw misalignment for wake steering

Wake steering strategies are employed to increase the overall power production of wind farms by deflecting wakes of upstream turbines away from downstream ones. The gain in net power comes at the expense of increased fatigue loads experienced by downstream turbines. In this work we investigate performance and fatigue loading characteristics of a small farm consisting of five aligned International Energy Agency Wind Technology Collaboration Programme 15 MW wind turbines. A parametric study is performed where, for every wind direction from −20 to 20°, the yaw misalignment angle varies from −25 to 25°. This setup allows us to investigate asymmetries and identify optimal conditions for a given wind direction. In general, we find that positive yaw configurations are preferred and that yaw configurations that result in attractive power differences when compared to a baseline no-yaw scenario (25 %) come with significant increase in fatigue loading (we use the standard deviation and damage-equivalent load (DEL) of the blade-root, low-speed shaft, and tower-base moments as proxies for fatigue load). We find that for any given positive wind inflow angle, yaw angles between −2.5 and 15° yield power differences of 10 %–20 % over a no-yaw baseline, and positive yaw is preferred because of lower fatigue loading. For any given negative wind inflow angles, positive yaw also results in lower magnitudes of standard deviation and DEL for the channels investigated. A small power loss of up to 2 % is observed for some positive yaw angles under negative wind directions (as compared to symmetric negative yaw and positive wind cases), but improvements in terms of loads exceed 25 % and may be enough to justify a positive yaw configuration under negative winds as well. We show that such behavior can be explained by partial waking and the direction of the rotation of the rotor.

17 WIND ENERGY↗

Oblique and rippled heliosphere structures from the Interstellar Boundary Explorer

Abstract Past analysis has shown that the heliosphere structure can be deduced from correlations between long-scale solar wind pressure evolution and energetic neutral atom emissions. However, this required spatial and temporal averaging that smoothed out small or dynamic features of the heliosphere. In late 2014, the solar wind dynamic pressure increased by roughly 50% over a period of 6 months, causing a time and directional-dependent rise in around 2–6 keV energetic neutral atom fluxes from the heliosphere observed by the Interstellar Boundary Explorer. Here, we use the 2014 pressure enhancement to provide a simultaneous derivation of the three-dimensional heliospheric termination shock (HTS) and heliopause (HP) distances at high resolution from Interstellar Boundary Explorer measurements. The analysis reveals rippled HTS and HP surfaces that are oblique with respect to the local interstellar medium upwind direction, with significant asymmetries in the heliosphere structure compared to steady-state heliosphere models. We estimate that the heliosphere boundaries contain roughly ten astronomical unit-sized spatial variations, with slightly larger variations on the HTS surface than the HP and a large-scale, southwards-directed obliquity of the surfaces in the meridional plane. Comparisons of the derived HTS and HP distances with Voyager observations indicate substantial differences in the heliosphere boundaries in the northern versus southern hemispheres and their motion over time.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Categorizing distributed wind energy installations in the United States to inform research and stakeholder priorities

Abstract Background Distributed wind energy adoption in the United States can contribute to the diverse portfolio of energy technologies needed to achieve ambitious decarbonization goals. However, with limited deployment to date, the current distributed wind market must be better understood; these efforts will support the range of stakeholders who will drive successful deployment. This article first distinguishes three categories of distributed wind from existing literature: (1) behind the meter, (2) intended for explicit local load, and (3) physically distributed. A novel methodology to classify individual wind installations into each of these categories is then presented and applied to two data sets of wind installations in the United States to categorize and illuminate distinct segments in the distributed wind market. Results Physically distributed installations, constituted by small to moderately sized projects serving local loads on distribution systems solely because of their proximity to them, account for the highest amount of capacity but the lowest number of installations out of the three categories. The inverse is true for behind-the-meter installations, which are used to serve on-site loads. Installations intended for explicit local load, which are interconnected on the utility side of the distribution system and intentionally built to provide energy to loads on the same distribution system, rank in the middle for both installed capacity and number of installations. Conclusions Distributed wind energy deployment in the United States is geographically widespread, but the extent to which a single category is developed in each state varies. Policies, wind resources, and broad energy technology trends contribute to these deployment patterns. By identifying the extent to which each category of installations exists, decision-makers are empowered with data necessary to tailor research and development programs and address stakeholder priorities through policy and other means, ultimately supporting future deployment.

17 WIND ENERGY↗

Wind Turbine Gearbox Failure Detection Through Cumulative Sum of Multivariate Time Series Data

The wind energy industry is continuously improving their operational and maintenance practice for reducing the levelized costs of energy. Anticipating failures in wind turbines enables early warnings and timely intervention, so that the costly corrective maintenance can be prevented to the largest extent possible. It also avoids production loss owing to prolonged unavailability. One critical element allowing early warning is the ability to accumulate small-magnitude symptoms resulting from the gradual degradation of wind turbine systems. Inspired by the cumulative sum control chart method, this study reports the development of a wind turbine failure detection method with such early warning capability. Specifically, the following key questions are addressed: what fault signals to accumulate, how long to accumulate, what offset to use, and how to set the alarm-triggering control limit. We apply the proposed approach to 2 years’ worth of Supervisory Control and Data Acquisition data recorded from five wind turbines. We focus our analysis on gearbox failure detection, in which the proposed approach demonstrates its ability to anticipate failure events with a good lead time.

17 WIND ENERGY↗

Analysis of Fire-Induced Circulations during the FireFlux2 Experiment

Despite recent advances in both coupled fire modeling and measurement techniques to sample the fire environment, the fire–atmosphere coupling mechanisms that lead to fast propagating wildfires remain poorly understood. This knowledge gap adversely affects fire management when wildland fires propagate unexpectedly rapidly and shift direction due to the fire impacts on local wind conditions. In this work, we utilized observational data from the FireFlux2 prescribed burn and numerical simulations performed with a coupled fire–atmosphere model WRF-SFIRE to assess the small-scale impacts of fire on local micrometeorology under moderate wind conditions (10–12 m/s). The FireFlux2 prescribed burn provided a comprehensive observational dataset with in situ meteorological observations as well as IR measurements of fire progression. To directly quantify the effects of fire–atmosphere interactions, two WRF-SFIRE simulations were executed. One simulation was run in a two-way coupled mode in which the heat and moisture fluxes emitted from the fire were injected into the atmosphere, and the other simulation was performed in a one-way coupled mode for which the atmosphere was not affected by the fire. The difference between these two simulations was used to analyze and quantify the fire impacts on the atmospheric circulation at different sections of the fire front. The fire-released heat fluxes resulted in vertical velocities as high as 10.8 m/s at the highest measurement level (20 m above ground level) gradually diminishing with height and dropping to 7.9 m/s at 5.77 m. The fire-induced horizontal winds indicated the strongest fire-induced flow at the lowest measurement levels (as high as 3.3 m/s) gradually decreasing to less than 1 m/s at 20 m above ground level. The analysis of the simulated flow indicates significant differences between the fire-induced circulation at the fire head and on the flanks. The fire-induced circulation was much stronger near the fire head than at the flanks, where the fire did not produce particularly strong cross-fire flow and did not significantly change the lateral fire progression. However, at the head of the fire the fire-induced winds blowing across the front were the strongest and significantly accelerated fire progression. The two-way coupled simulation including the fire-induced winds produced 36.2% faster fire propagation than the one-way coupled run, and more realistically represented the fire progression.

Benik, Jeremy T.↗

DigiFloat (Final Scientific/Technical Report)

This purpose of this report is to document the development of a floating offshore wind platform Digital Twin for the ARPA-E-funded DigiFloat project led by Principle Power, Inc. In Offshore Wind, Digital Twins are aimed at reducing farm-wide OPEX expenditures through reduced-basis inspection, assessing life extension methods, and obtaining better knowledge of the deployed assets for future product optimization. There is a high level of technical effectiveness and economic feasibility for the technology investigated, as it uses commercial off-the-shelf sensors, and a commercial software package. A substantial portion of the project goals are improvement of existing technology for use with floating wind turbines, and new application of an existing technology to a rapidly-growing sector. A few sensors applied to a small number of units bring benefit to the entire fleet of floating wind turbines in a given farm, and in other future wind farms. The benefits to the public of this project are further optimization and maturation of floating wind technology, to bring it to the U.S. market faster and cheaper.

17 WIND ENERGY↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗