Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development and Testing of a Superconducting Ground Plane on Transition Edge Sensors

Much of the normal matter in the universe is thought to exist as diffuse hot gas near 1.0 × 10 6 K, which can be detected through its 0.1–0.5 keV line emission. Distinguishing among multiple temperature regions and emission mechanisms along a line of sight requires resolving individual spectral lines in this particularly crowded spectral range. This requires 1–2 eV spectral resolution, which is currently only possible using grating spectrometers, which are suitable only for point sources, but not for the diffuse sources we wish to observe. We aim to measure individual spectral lines in this energy band using transition edge sensors (TES) that have the required 1–2 eV non-dispersive spectral resolution on a sounding rocket. While TESs offer sufficient energy resolution, they are very sensitive to ambient magnetic fields, e.g. from earth’s field and stray fields from the adiabatic demagnetization refrigerator (ADR) that is used to cool TESs to their ∼70 mK transition temperature. Strict space and weight limitations on the sounding rocket payload will limit the use of conventional high permeability magnetic shielding. Further design challenges arise in designing shielding with at least a 45∘ field of view, which is required to maintain a large enough throughput to obtain a useful spectrum on a brief (∼300 s) sounding rocket flight. Here we explore adding a superconducting ground plane (SGP) to the backside of the TES to reduce its field sensitivity and minimize attenuation requirements for the external shielding, which is based on prior work from (de Wit et al. 2022). We tested the feasibility of SGPs with novel materials, geometries, and on larger TESs with different biasing conditions.

Astrophysics↗

Analytical-HZETRN Model for Rapid Assessment of Active Magnetic Radiation Shielding

The use of active radiation shielding designs has the potential to reduce the radiation exposure received by astronauts on deep-space missions at a significantly lower mass penalty than designs utilizing only passive shielding. Unfortunately, the determination of the radiation exposure inside these shielded environments often involves lengthy and computationally intensive Monte Carlo analysis. In order to evaluate the large trade space of design parameters associated with a magnetic radiation shield design, an analytical model was developed for the determination of flux inside a solenoid magnetic field due to the Galactic Cosmic Radiation (GCR) radiation environment. This analytical model was then coupled with NASA's radiation transport code, HZETRN, to account for the effects of passive/structural shielding mass. The resulting model can rapidly obtain results for a given configuration and can therefore be used to analyze an entire trade space of potential variables in less time than is required for even a single Monte Carlo run. Analyzing this trade space for a solenoid magnetic shield design indicates that active shield bending powers greater than 15 Tm and passive/structural shielding thicknesses greater than 40 g/cm2 have a limited impact on reducing dose equivalent values. Also, it is shown that higher magnetic field strengths are more effective than thicker magnetic fields at reducing dose equivalent.

Washburn, S. A.↗

The New Anechoic Shielded Chambers Designed for Space and Commercial Applications at LIT

The main objective of this paper is to present the capabilities of the new anechoic shielded rooms designed for space and commercial applications as part of the Integration and Testing Laboratory (LIT, Laboratorio de Integracao e Testes) in Brazil. A new anechoic shielded room named CBA2 has been in full operation since March 2007 and a remodeled chamber CBA1 is planned to be ready by the end of 2008, replacing an old facility which was in operation for the last 18 years. The Brazilian Space Program started with very small and simple satellites and the old CBA1 chamber was conceived in 1987 to accomplish the EMI/EMC tests not requiring significant volumes. Since the very beginning this facility was also used by the private sector for other applications mainly due to the absorption of digital electronics in all kind of products. The intense use of this facility during the last years, operating three shifts a day, caused a normal degradation and imposed several limitations. Therefore, a new totally remodeled chamber was designed considering the state of the art in terms of absorbers and associated instrumentation. On the other hand the facility CBA2 was conceived, designed and implemented to test large satellites taking into account the advance of the technology in terms of RF frequencies, power level, testing methodologies and several other factors. A very interesting and unique aspect of this project was the partnership between the private sector and governmental institution. As a result, the total investment was shared between several companies and consequently a time-sharing use of the facility as well.

da Silva, Benjamim↗

International Space Station (ISS) Meteoroid/Orbital Debris Shielding

Design practices to provide protection for International Space Station (ISS) crew and critical equipment from meteoroid and orbital debris (M/OD) Impacts have been developed. Damage modes and failure criteria are defined for each spacecraft system. Hypervolocity Impact -1 - and analyses are used to develop ballistic limit equations (BLEs) for each exposed spacecraft system. BLEs define Impact particle sizes that result in threshold failure of a particular spacecraft system as a function of Impact velocity, angles and particle density. The BUMPER computer code Is used to determine the probability of no penetration (PNP) that falls the spacecraft shielding based on NASA standard meteoroid/debris models, a spacecraft geometry model, and the BLEs. BUMPER results are used to verify spacecraft shielding requirements Low-weight, high-performance shielding alternatives have been developed at the NASA Johnson Space Center (JSC) Hypervelocity Impact Technology Facility (HITF) to meet spacecraft protection requirements.

Christiansen, Eric L.↗

Radiation shielding methods

System aids in charged-particle radiation transport analysis and shielding design. System can be adapted for shielding design and analysis in any charged-particle radiation environment.

Davis, H. S.↗

Second Target Station (STS) Project: Analysis of Bunker Shielding–Preliminary Design

At the Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. The simulations in this report used the ST11 beamline source, primarily the ST11 neutron source, because that source provides conservative prompt total dose rate estimates for all beamlines. Prompt total dose rates (i.e., neutron plus photon dose rates when the beam is on) were calculated on top of the bunker roof, outside the bunker wall, and in the basement below the bunker and instrument floor. Design changes were made to ensure the prompt total dose rate in these areas does not exceed 0.25 mrem/h. This report documents the required shielding thicknesses to meet this dose rate limit. There is one exception to this: for a combination of open and closed beamlines, the prompt total dose rate outside the bunker across from the closed beamline, where there is less shielding due to the lack of beamline shielding, slightly exceeds 0.25 mrem/h. A future analysis will document the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 0.25 mrem/h once more details regarding the STS high density concrete density and composition are known. Finally, prompt total dose rates inside the bunker were simulated. The results of this simulation show that the majority of prompt total dose rate in the bunker is due to neutrons, and a few percent of the total is caused by secondary photons created by the neutrons. The contribution to prompt total dose rate inside the bunker by the primary photons that enter each beamline from the target/moderator area is at least two orders of magnitude less than the neutron contribution. This means prompt total dose rate contributions due to primary photons inside and outside the bunker can be neglected.

42 ENGINEERING↗

Designing space vehicle shields for meteoroid protection - A new analysis

A new analysis for designing dual-layer shields is presented which is based on energy and momentum conservation, fundamental electromagnetic radiation physics, and the observation of results of extensive experimental impact studies performed at relatively low velocities (near 7 km/s). An important finding is that most of the kinetic energy of a meteoroid striking a dual-layer shield is expended as radiation at the stagnation zone on the face plate of the underlying structure. Systematic procedures for evaluating the response of shield designs for a given impact threat are described. It is noted that similar applications of the analysis can be employed to support a mathematically rigorous procedure for optimum shield design.

Swift, H. F.↗

Simbol-X Mirror Module Thermal Shields: I - Design and X-Ray Transmission

The Simbol-X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X-ray transmission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗

Starprobe thermal shield system design concepts

The mission goals, flight trajectory, and material durability requirements for the NASA Starprobe spacecraft are reviewed. The spacecraft will use a Jovian gravity assist to pass within four solar radii of the sun to study fields and particles near the sun, perform experiments dealing with relativity and gravity, and observe the structure of the solar atmosphere from the photosphere to the corona. Constraints on the system size and mass design are given, and the system is noted to be required to withstand 2500 K at perihelion, thermally insulate the instrument payload, have a tube for optical measurements, and provide protection from meteorite damage. A secondary shield is also required to dispense thermal radiation that passes the primary shield and could endanger the payload. Design options are discussed, along with temperature control requirements and a conical carbon-carbon primary shield with mass-loss rate characteristics sufficient to meet a 2.5 mg/sec criterion.

Maag, C. R.↗

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗

HDR brachytherapy of rectal cancer using a novel grooved-shielding applicator design

Purpose: The aim of this work was to design a novel high-dose rate (HDR) ({sup 192}Ir) brachytherapy applicator for treatment of rectal carcinomas that uses tungsten shielding for possibly improved dosimetric results over commercial brachytherapy applicator(s).Methods: A set of 15 single-depth applicators and one dual-depth applicator were designed and simulated using Monte Carlo (MCNPX). All applicators simulated were high-density tungsten alloy cylinders, 16-mm in diameter, and 60-mm long, with longitudinal grooves within which an {sup 192}Ir source can be placed. The single-depth designs varied regarding the number and depth of these grooves, ranging from 8 to 16 and 1-mm to 3-mm, respectively. The dual-depth design had ten channels, each of which had two depths at which the source could be placed. Optimized treatment plans were generated for each design on data from 13 treated patients (36 fractions) with asymmetrical clinical target volumes (CTVs). All results were compared against the clinically treated plans which used intracavitary mold applicator (ICMA), as well as a recently designed, highly automated, and collimated intensity modulation device named dynamic modulated brachytherapy (DMBT) device.Results: All applicator designs outperformed the ICMA in every calculated dosimetric criteria, except the total dwell times (∼30% increase). There were clear, but relative, tradeoffs regarding both the number of channels and the depth of each channel. Overall, the 12-channel, 1-mm depth, and 14-channel 2-mm depth designs had the best results of the simpler designs, sparing the healthy rectal tissues the most while achieving comparable CTV coverage with the dose heterogeneity index and lateral spill doses improving by over 10% and the contralateral healthy rectum dose dropping over 30% compared to ICMA. The ten-channel dual-depth design outperformed each single-depth design, yielding the best coverage and sparing.Conclusions: New grooved tungsten HDR-brachytherapy devices have been designed and simulated. The results of this work attest to the capability of these new, highly anisotropic, intelligently shielded applicators to limit dose to healthy tissues while maintaining a conformal prescription dose to the CTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DESIGN AND SHIELDING OF A BEAM LINE FROM ELENA TO ATRAP USING ELECTROSTATIC QUADRUPOLE LENSES AND BENDS

The construction of the Extra Low ENergy Antiprotons (ELENA) upgrade to the Antiproton Decelerator (AD) ring has been proposed at CERN to produce a greatly increased current of low-energy antiprotons for various experiments including anti-hydrogen studies. This upgrade involves the addition of a small storage ring and electrostatic beam lines. The 5.3-MeV antiproton beams from AD are decelerated down to 100 keV in the compact ring and transported to each experimental apparatus. In this paper, we describe an electrostatic beam line from the ELENA ring to the ATRAP experimental apparatus and magnetic shielding of the low-energy beam line against the ATRAP superconducting solenoid magnet. A possible rough conceptual design of this system is displayed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, fabrication, and structural testing of a lightweight shadow shield for deep-space application

Two full-scale, lightweight, double-sheeted shadow shields were developed as the primary element of a deep-space thermal protection system for liquid-hydrogen propellant tankage. The thermal and mechanical considerations used in s, the method of fabrication, and the environmental testing results on a prototype shield are discussed. Testing consisted of a transient cooldown period, a prolonged cold soak, and a transient warmup. The mechanical and thermal analyses used in the shield design are sufficient to produce a lightweight rugged shadow shield assembly that is structurally adequate for its intended application.

Miao, D.↗

The design of reactive shielded magnet clutches

The design of reactive shielded magnet clutches is considered along with their schematics, design formulas and characteristics of clutches in general. The design method suggested makes it possible to reduce calculation errors to 10%.

Gertsov, S. M.↗

Radiation Modeling of Z1: Validation of a Novel Radioisotope System

This paper presents the development of a radiation model for a novel strontium-90 (Sr-90) radioisotope heat source developed by Zeno Power Systems (Zeno), which demonstrates a groundbreaking fuel and shielding design that significantly reduces weight compared to traditional concepts. A Monte Carlo N-Particle (MCNP) model has been created to assess the effectiveness of this fuel and shielding design, however validation of the MCNP model is desired. Zeno has developed a prototype device (Z1) to aid in this model validation effort. This project is a collaborative effort between Zeno, the University of Dayton Research Institute (UDRI) and Pacific Northwest National Laboratory (PNNL), where the Z1 prototype was constructed and characterized.

RTG↗