Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of the Prototype Holographic Atmospheric Scanner for Environmental Remote Sensing (PHASERS)

This study represents the first successful employment of the Holographic Optical Telescope and Scanner (HOTS) technology to make atmospheric backscattering measurements in a scanning mode. In several independent attempts the system successfully detected the return signal from atmospheric structures as they moved across the field-of-view (FOV) of the rotating Holographic Optical Element (HOE). Future plans include the addition of a narrow band filter and the necessary optics for day-time measurements, along with additional automation of the system and its data handling. In part, due to the success of this demonstration of the HOTS technology a new class of light weight scanning telescopes for lidar remote sensing from air and space craft platforms are under development and being tested for additional applications.

Guerra, David V.↗

Beam emittance measurements in RHIC

The RHIC proton polarimeters can operate in scanning mode, giving polarization profiles and transverse beam intensity profile (beam emittance) measurements. The polarimeters function as wire scanners, providing a very good signal/noise ratio and high counting rate. This allows accurate bunch-by-bunch emittance measurements during fast target sweeps (<1 s) through the beam. Very thin carbon strip targets make these measurements practically non-destructive. Bunch by bunch emittance measurements are a powerful tool for machine set-up; in RHIC, individual proton beam transverse emittances can only be measured by CNI polarimeter scans. We discuss the consistency of these measurements with Ionization Profile Monitors (IPMs) and vernier scan luminosity measurements. Absolute accuracy limitations and cross-calibration of different techniques are also discussed.

43 PARTICLE ACCELERATORS↗

Nano-cell Fabrication Using the Behavior of Point Defects Induced by Ion Implantation

The authors' finding that cellular structure is formed on the GaSb, InSb and Ge surfaces by ion implantation is introduced. A novel nano-fabrication technique based on the authors' discovery, which consists of a top-down process and a bottom-up process, is performed on a GaSb surface using focused ion beam. In the top-down procedure, a two-dimensional lattice of voids (initial structure) is created by irradiation with a focused ion beam. Then, the bottom-up process for developing the initial structure into nano-cell structures is performed using the image scanning mode of FIB. The structure is observed by FIB and SEM. The possibilities of the new technique are examined, varying the ion acceleration voltage and the ion dose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters

Purpose: To investigate the effect of energy (kVp) and filters (no filter, half Bowtie, and full Bowtie) on the dose response curves of the Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters (OSLDs) in CBCT dose fields. To measure surface and internal doses received during x-ray volume imager (XVI) (Version R4.5) and on board imager (OBI) (Version 1.5) CBCT imaging protocols using these two types of dosimeters. Methods: Gafchromic XRQA2 film and nanoDot OSLD dose response curves were generated at different kV imaging settings used by XVI (software version R4.5) and OBI (software version 1.5) CBCT systems. The settings for the XVI system were: 100 kVp/F0 (no filter), 120 kVp/F0, and 120 kVp/F1 (Bowtie filter), and for the OBI system were: 100 kVp/full fan, 125 kVp/full fan, and 125 kVp/half fan. XRQA2 film was calibrated in air to air kerma levels between 0 and 11 cGy and scanned using reflection scanning mode with the Epson Expression 10000 XL flat-bed document scanner. NanoDot OSLDs were calibrated on phantom to surface dose levels between 0 and 14 cGy and read using the inLight{sup TM} MicroStar reader. Both dosimeters were used to measure in field surface and internal doses in a male Alderson Rando Phantom. Results: Dose response curves of XRQA2 film and nanoDot OSLDs at different XVI and OBI CBCT settings were reported. For XVI system, the surface dose ranged between 0.02 cGy in head region during fast head and neck scan and 4.99 cGy in the chest region during symmetry scan. On the other hand, the internal dose ranged between 0.02 cGy in the head region during fast head and neck scan and 3.17 cGy in the chest region during chest M20 scan. The average (internal and external) dose ranged between 0.05 cGy in the head region during fast head and neck scan and 2.41 cGy in the chest region during chest M20 scan. For OBI system, the surface dose ranged between 0.19 cGy in head region during head scan and 4.55 cGy in the pelvis region during spot light scan. However, the internal dose ranged between 0.47 cGy in the head region during head scan and 5.55 cGy in the pelvis region during spot light scan. The average (internal and external) dose ranged between 0.45 cGy in the head region during head scan and 3.59 cGy in the pelvis region during spot light scan. Both Gafchromic XRQA2 film and nanoDot OSLDs gave close estimation of dose (within uncertainties) in many cases. Though, discrepancies of up to 20%-30% were observed in some cases. Conclusions: Dose response curves of Gafchromic XRQA2 film and nanoDot OSLDs indicated that the dose responses of these two dosimeters were different even at the same photon energy when different filters were used. Uncertainty levels of both dosimetry systems were below 6% at doses above 1 cGy. Both dosimetry systems gave almost similar estimation of doses (within uncertainties) in many cases, with exceptions of some cases when the discrepancy was around 20%-30%. New versions of the CBCT systems (investigated in this study) resulted in lower imaging doses compared with doses reported on earlier versions in previous studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-A-12A-12: Improved Airway Measurement Accuracy for Low Dose Quantitative CT (qCT) Using Statistical (ASIR), at Reduced DFOV, and High Resolution Kernels in a Phantom and Swine Model

Purpose: Quantitative accuracy of Iodine Hounsfield Unit (HU) in conventional single-kVp scanning is susceptible to beam-hardening effect. Dual-energy CT has unique capabilities of quantification using monochromatic CT images, but this scanning mode requires the availability of the state-of-the-art CT scanner and, therefore, is limited in routine clinical practice. Purpose of this work was to develop a beam-hardening-correction (BHC) for single-kVp CT that can linearize Iodine projections at any nominal energy, apply this approach to study Iodine response with respect to keV, and compare with dual-energy based monochromatic images obtained from material-decomposition using 80kVp and 140kVp. Methods: Tissue characterization phantoms (Gammex Inc.), containing solid-Iodine inserts of different concentrations, were scanned using GE multi-slice CT scanner at 80, 100, 120, and 140 kVp. A model-based BHC algorithm was developed where Iodine was estimated using re-projection of image volume and corrected through an iterative process. In the correction, the re-projected Iodine was linearized using a polynomial mapping between monochromatic path-lengths at various nominal energies (40 to 140 keV) and physically modeled polychromatic path-lengths. The beam-hardening-corrected 80kVp and 140kVp images (linearized approximately at effective energy of the beam) were used for dual-energy material-decomposition in Water-Iodine basis-pair followed by generation of monochromatic images. Characterization of Iodine HU and noise in the images obtained from singlekVp with BHC at various nominal keV, and corresponding dual-energy monochromatic images, was carried out. Results: Iodine HU vs. keV response from single-kVp with BHC and dual-energy monochromatic images were found to be very similar, indicating that single-kVp data may be used to create material specific monochromatic equivalent using modelbased projection linearization. Conclusion: This approach may enable quantification of Iodine contrast enhancement and potential reduction in injected contrast without using dual-energy scanning. However, in general, dual-energy scanning has unique value in material characterization and quantification, and its value cannot be discounted. GE Healthcare Employee.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gold, Copper and Platinum Nanoparticles Dispersed on CeOx/TiO2(110) Surfaces: High Water-Gas Shift Activity and the Nature of the Mixed-Metal Oxide at the Nanometer Level

At small coverages of ceria on TiO{sub 2}(110), the CeO{sub x} nanoparticles have an unusual coordination mode. Scanning tunneling microscopy and density-functional calculations point to the presence of Ce{sub 2}O{sub 3} dimers, which form diagonal arrays that have specific orientations of 0, 24, and 42{sup o} with respect to the [1 -1 0] direction of the titania substrate. At high coverages of ceria on TiO{sub 2}(110), the surface exhibits two types of terraces. In one type, the morphology is not very different from that observed at low ceria coverage. However, in the second type of terrace, there is a compact array of ceria particles with structures that do not match the structures of CeO{sub 2}(111) or CeO{sub 2}(110). The titania substrate imposes on the ceria nanoparticles nontypical coordination modes, enhancing their chemical reactivity. This phenomenon leads to a larger dispersion of supported metal nanoparticles (M = Au, Cu, Pt) and makes possible the direct participation of the oxide in catalytic reactions. The M/CeO{sub x}/TiO{sub 2}(110) surfaces display an extremely high catalytic activity for the water-gas shift reaction that follows the sequence Au/CeO{sub x}/TiO{sub 2}(110) < Cu/CeO{sub x}/TiO{sub 2}(110) < Pt/CeO{sub x}/TiO{sub 2}(110). For low coverages of Cu and CeO{sub x}, Cu/CeO{sub x}/TiO{sub 2}(110) is 8-12 times more active than Cu(111) or Cu/ZnO industrial catalysts. In the M/CeO{sub x}/TiO{sub 2}(110) systems, there is a strong coupling of the chemical properties of the admetal and the mixed-metal oxide: The adsorption and dissociation of water probably take place on the oxide, CO adsorbs on the admetal nanoparticles, and all subsequent reaction steps occur at the oxide-admetal interface. The high catalytic activity of the M/CeO{sub x}/TiO{sub 2}(110) surfaces reflects the unique properties of the mixed-metal oxide at the nanometer level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gold, Copper, and Platinum Nanoparticles Dispersed on CeOx/TiO2(110) Surfaces: High Water-Gas Shift Activity and the Nature of the Mixed-Metal Oxide at the Nanometer Level

At small coverages of ceria on TiO{sub 2}(110), the CeO{sub x} nanoparticles have an unusual coordination mode. Scanning tunneling microscopy and density-functional calculations point to the presence of Ce{sub 2}O{sub 3} dimers, which form diagonal arrays that have specific orientations of 0, 24, and 42{sup o} with respect to the [1 -1 0] direction of the titania substrate. At high coverages of ceria on TiO{sub 2}(110), the surface exhibits two types of terraces. In one type, the morphology is not very different from that observed at low ceria coverage. However, in the second type of terrace, there is a compact array of ceria particles with structures that do not match the structures of CeO{sub 2}(111) or CeO{sub 2}(110). The titania substrate imposes on the ceria nanoparticles nontypical coordination modes, enhancing their chemical reactivity. This phenomenon leads to a larger dispersion of supported metal nanoparticles (M = Au, Cu, Pt) and makes possible the direct participation of the oxide in catalytic reactions. The M/CeO{sub x}/TiO{sub 2}(110) surfaces display an extremely high catalytic activity for the water-gas shift reaction that follows the sequence Au/CeO{sub x}/TiO{sub 2}(110) < Cu/CeO{sub x}/TiO{sub 2}(110) < Pt/CeO{sub x}/TiO{sub 2}(110). For low coverages of Cu and CeO{sub x}, Cu/CeO{sub x}/TiO{sub 2}(110) is 8-12 times more active than Cu(111) or Cu/ZnO industrial catalysts. In the M/CeO{sub x}/TiO{sub 2}(110) systems, there is a strong coupling of the chemical properties of the admetal and the mixed-metal oxide: The adsorption and dissociation of water probably take place on the oxide, CO adsorbs on the admetal nanoparticles, and all subsequent reaction steps occur at the oxide-admetal interface. The high catalytic activity of the M/CeO{sub x}/TiO{sub 2}(110) surfaces reflects the unique properties of the mixed-metal oxide at the nanometer level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗

Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP-SAIL)

The Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP) project was conducted to help improve the understanding of precipitation formation in orographically influenced terrain. Special focus is put on the two processes of riming and secondary ice production and their external drivers. Two instruments, a polarimetric W-band simultaneous transmission simultaneous reception (STSR) Doppler cloud radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP), from now on named LIMRAD94, and the video in situ snowfall sensor (VISSS), were deployed at the U. S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) site in Gothic, Colorado between November 2022 and June 2023 during the second SAIL winter. Note that the exact dates of data availability differ between the instruments. Both instruments arrived at Gothic on November 2, 2022, 09:20 local time. VISSS, described by Maahn et al., is equipped with two camera systems with telecentric lenses. The two cameras are at a 90° angle to each other. This configuration allows for size-independent measurements by capturing images of hydrometeors from two sides at a high frame rate of 250 Hz. With a minimum detection size of 200 μm, VISSS provides valuable insights into particle size, number, shape, complexity, and fall velocity. The VISSS was deployed on the grassland next to the ARM facility with the amazing help of the ARM employees on site. The setup started on November 2, 2022, and was finished on November 5, 2022, without major problems. VISSS measurements were started on November 6, 2022. LIMRAD94 was installed on a scaffolding platform near Orehouse (Gothic) on November 9, 2022, with the great help of RMBL staff. LIMRAD94 was mounted on a cold temperature scanner prototype. After a short test of the setup on November 9, 2022, the digital control of the scanner elevation stopped working for (at that time) unknown reasons. All attempts to resolve the problem failed. This malfunction made it impossible to operate LIMRAD94 in scanning mode. The scanner was then manually moved to zenith pointing mode and between November 10 and November 15, 2022, vertical observations for polarimetric calibration were performed. On November 15, 2022, after the polarimetric calibration was applied, the scanner was manually moved to 40° elevation with azimuthal view towards the Ka-band ARM Zenith Radar (KAZR) and measurements were continued at constant elevation. Investigation of the scanner malfunction on February 6, 2023, by Benn Schmatz revealed a disengagement between the cogwheel of the elevation motor and the cogwheel moving the scanner in elevation. This mechanical issue was temporarily solved by re-engaging the cogwheels. This made the scanner operational again for about four weeks, until mechanical force disengaged the cogwheels again on March 15, 2023. This repeated scanner failure remained undetected for about three weeks until April 8, 2023; during this time the scanner was stuck at 72° elevation. However, the radar software continued to produce data files falsely indicating that the scanner was still operational. After the scanner failure was noticed, scanning was stopped again, and we returned to constant elevation measurements. On May 15, 2023, the cogwheels of the elevation motor were secured with additional screws sent by the manufacturer. At some point in May, the cogwheels of the azimuth motor were also disengaged by mechanical force, which still allowed for range height indicator (RHI) but no plan position indicator (PPI) scans in the last weeks of the campaign. The azimuth motor was repaired in Germany after the end of the campaign. Throughout the campaign, RMBL and ARM staff kept the radar and the VISSS free of snow.

54 ENVIRONMENTAL SCIENCES↗

Undercooling minimization in ultrasound coupled DTA measurements of molten salts

Molten salts are ionic liquids that are used for the electrolytic pyroprocessing of metals and as heat transfer fluids in very high temperature processes. Recently, halide-based molten salt reactors (MSR) have gained momentum for high density and environmentally responsible electricity generation. The function of these reactors and their fuel cycle depend on a knowledge of the halide salt’s thermodynamic properties [1]. Therefore, high accuracy phase equilibria of MSR relevant base halide and actinide containing salts are needed. Modern thermal analysis of the phase transitions of halide salts is usually done during heating at relatively high scan rates with commercial devices. Normally such measurements are adequate for pure or pseudo-binary salts. However, as the number of components in the mixture increases, accurately resolving the liquidus becomes increasingly difficult. Reversing the scanning mode greatly increases the sensitivity of phase transition measurements but can decrease accuracy due to undercooling [2] — a common occurrence in molten halide systems [3]. This work presents the development of a differential thermal analysis (DTA) cell intended for use in radiological gloveboxes. Non-contact ultrasonic agitation of the halide salt is implemented to limit kinetic limitations on crystallization during cooling to minimize undercooling [4]. Measurements on halide salts are also presented to elucidate the effect of non-contact mixing on undercooling. Reference [1] S. Boyd and C. Taylor, “3 - Chemical fundamentals and applications of molten salts,” in Molten Salt Reactors and Thorium Energy, T. J. Dolan, Ed., Woodhead Publishing, 2017, pp. 29–91. doi: 10.1016/B978-0-08-101126-3.00003-8. [2] K. Nitsch, A. Cihlár, and M. Rodová, “Molten state and supercooling of lead halides,” J. Cryst. Growth, vol. 264, no. 1, pp. 492–498, Mar. 2004, doi: 10.1016/j.jcrysgro.2004.01.011. [3] L. Rycerz, “Practical remarks concerning phase diagrams determination on the basis of differential scanning calorimetry measurements,” J. Therm. Anal. Calorim., vol. 113, no. 1, pp. 231–238, Jul. 2013, doi: 10.1007/s10973-013-3097-0. [4] Md. H. Zahir, S. A. Mohamed, R. Saidur, and F. A. Al-Sulaiman, “Supercooling of phase-change materials and the techniques used to mitigate the phenomenon,” Appl. Energy, vol. 240, pp. 793–817, Apr. 2019, doi: 10.1016/j.apenergy.2019.02.045.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

47 OTHER INSTRUMENTATION↗

Gas discharge plasma treatment of poly(ethylene glycol-co-1,3/1,4 cyclohexanedimethanol terephthalate) for enhanced paint adhesion

Low-energy hydrogen-ions and tetrafluoromethane-ions produced from a gas discharge ion source were irradiated to poly(ethylene glycol-co-1,3/1,4 cyclohexanedimethanol terephthalate) (PETG) sheets for enhancing paint adhesion. The ion beams were characterized using a cast steel mass spectrometer, while the untreated and treated samples were characterized using Fourier transform infrared spectroscopy, scanning electron microscopy, contact angle measurements, and profilometry. The paint adhesion was determined by using the standard method for evaluating adhesion by knife [ASTM D6677-07, Standard Test Method for Evaluating Adhesion by Knife (ASTM International, West Conshohocken, PA, 2012)] and was correlated with the calculation of the work of adhesion derived from the Young–Dupré equation. After plasma treatment, a significant decrease in the contact angle was observed in all samples, except for the CF{sub 4} ion-treated samples with the discharge current of 3 mA and an irradiation time of 30 min. At longer irradiation times, the treated samples showed lesser changes in the contact angle measurement. The increase in the average and root-mean-square surface roughness was observed on the samples after plasma treatment. The samples treated with either H{sub 2} or CF{sub 4} ions for 15 min showed a direct correlation between the discharge current and surface roughness. The samples treated for 30 min showed no significant correlation between the surface roughness and discharge current, which can be attributed to the possible melting of the samples since PETG has a low melting point. The observation made in this study on the relationship of wettability and surface roughness is consistent with the Wenzel wetting mode. Scanning electron micrographs showed surface etching on the hydrogen ion-treated samples while no significant surface changes were observed for the CF{sub 4} ion-treated samples. In general, paint adhesion was stronger for samples that exhibited enhanced wettability and high work of adhesion. The optimal work of adhesion to double the paint adhesion performance was at least 84.79 mN/m. The increase in the surface roughness after the treatment provided an increased friction between the paint and the PETG surface. The increase in the paint adhesion was also due to the covalent, hydrogen, and van der Waals bonding that are typically observed for highly wettable surfaces.

36 MATERIALS SCIENCE↗

Helicopter Flight Test of a Compact, Real-Time 3-D Flash Lidar for Imaging Hazardous Terrain During Planetary Landing

A second generation, compact, real-time, air-cooled 3-D imaging Flash Lidar sensor system, developed from a number of cutting-edge components from industry and NASA, is lab characterized and helicopter flight tested under the Autonomous Precision Landing and Hazard Detection and Avoidance Technology (ALHAT) project. The ALHAT project is seeking to develop a guidance, navigation, and control (GN&C) and sensing system based on lidar technology capable of enabling safe, precise crewed or robotic landings in challenging terrain on planetary bodies under any ambient lighting conditions. The Flash Lidar incorporates a 3-D imaging video camera based on Indium-Gallium-Arsenide Avalanche Photo Diode and novel micro-electronic technology for a 128 x 128 pixel array operating at a video rate of 20 Hz, a high pulse-energy 1.06 μm Neodymium-doped: Yttrium Aluminum Garnet (Nd:YAG) laser, a remote laser safety termination system, high performance transmitter and receiver optics with one and five degrees field-of-view (FOV), enhanced onboard thermal control, as well as a compact and self-contained suite of support electronics housed in a single box and built around a PC-104 architecture to enable autonomous operations. The Flash Lidar was developed and then characterized at two NASA-Langley Research Center (LaRC) outdoor laser test range facilities both statically and dynamically, integrated with other ALHAT GN&C subsystems from partner organizations, and installed onto a Bell UH-1H Iroquois "Huey" helicopter at LaRC. The integrated system was flight tested at the NASA-Kennedy Space Center (KSC) on simulated lunar approach to a custom hazard field consisting of rocks, craters, hazardous slopes, and safe-sites near the Shuttle Landing Facility runway starting at slant ranges of 750 m. In order to evaluate different methods of achieving hazard detection, the lidar, in conjunction with the ALHAT hazard detection and GN&C system, operates in both a narrow 1deg FOV raster-scanning mode in which successive, gimbaled images of the hazard field are mosaicked together as well as in a wider, 4.85deg FOV staring mode in which digital magnification, via a novel 3-D superresolution technique, is used to effectively achieve the same spatial precision attained with the more narrow FOV optics. The lidar generates calibrated and corrected 3-D range images of the hazard field in real-time and passes them to the ALHAT Hazard Detection System (HDS) which stitches the images together to generate on-the-fly Digital Elevation Maps (DEM's) and identifies hazards and safe-landing sites which the ALHAT GN&C system can then use to guide the host vehicle to a safe landing on the selected site. Results indicate that, for the KSC hazard field, the lidar operational range extends from 100m to 1.35 km for a 30 degree line-of-sight angle and a range precision as low as 8 cm which permits hazards as small as 25 cm to be identified. Based on the Flash Lidar images, the HDS correctly found and reported safe sites in near-real-time during several of the flights. A follow-on field test, planned for 2013, seeks to complete the closing of the GN&C loop for fully-autonomous operations on-board the Morpheus robotic, rocket-powered, free-flyer test bed in which the ALHAT system would scan the KSC hazard field (which was vetted during the present testing) and command the vehicle to landing on one of the selected safe sites.

Roback, VIncent E.↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Size‐Tunable Synthesis of Hollow Gold Nanospheres through Control of Reaction Temperature

Here, it is demonstrated that the size tunable hollow gold nanospheres (HGNs) of ≈24–122 nm in diameter can be facilely achieved by controlling a signal parameter, reaction temperature, in the synthesis. The varied particle sizes of HGNs result in highly tunable surface plasmon resonance (SPR) absorption in the entire visible to near infrared region of the spectrum, with maximum peak position from 565 to 850 nm when the reaction temperature is varied from 80 to 10 °C. The particle size and structural properties are determined using dynamic light scattering, transmission‐mode scanning electron microscopy, and high‐resolution transmission electron microscopy. The optical properties are characterized using UV–vis spectroscopy. A mechanism behind the temperature‐dependent HGN synthesis is explained by the thermodynamics of homogeneous nuclei formation of the cobalt scaffold. Discrete dipole approximation calculations are performed to simulate the SPR spectrum and provide insight into the relation between the SPR absorption and structural details of the HGNs. This study demonstrates a simple yet effective method based on temperature control for synthesizing produce size tunable HGNs with varying properties of interest for different applications.

Pu, Ying‐Chih↗