Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Three-Dimensional Geometry of Collagenous Tissues by Second Harmonic Polarimetry

Collagen is a biological macromolecule capable of second harmonic generation, allowing label-free detection in tissues; in addition, molecular orientation can be determined from the polarization dependence of the second harmonic signal. Previously we reported that in-plane orientation of collagen fibrils could be determined by modulating the polarization angle of the laser during scanning. We have now extended this method so that out-of-plane orientation angles can be determined at the same time, allowing visualization of the 3-dimensional structure of collagenous tissues. This approach offers advantages compared with other methods for determining out-of-plane orientation. First, the orientation angles are directly calculated from the polarimetry data obtained in a single scan, while other reported methods require data from multiple scans, use of iterative optimization methods, application of fitting algorithms, or extensive post-optical processing. Second, our method does not require highly specialized instrumentation, and thus can be adapted for use in almost any nonlinear optical microscopy setup. It is suitable for both basic and clinical applications. We present three-dimensional images of structurally complex collagenous tissues that illustrate the power of such 3-dimensional analyses to reveal the architecture of biological structures.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring Roughnesses Of Optical Surfaces

Report discusses use of scanning tunneling microscopy and atomic force microscopy to measure roughnesses of optical surfaces. These techniques offer greater spatial resolution than other techniques. Report notes scanning tunneling microscopes and atomic force microscopes resolve down to 1 nm.

Coulter, Daniel R.↗

Path Scan Operational Data-Based Test Report

The TTP program is managed by DHS S&T Cyber Division and facilitates the transition of technology from the research lab to the Homeland Security Enterprise. It serves as a connection point for cyber security researchers, the Federal Government, and the private sector. Technologies targeted are those that are likely to transition successfully to the commercial market and expected to have notable impact on the cyber security of our Nation’s networks or systems. The test element of the TTP program aids in the technology transfer process and is not intended to be adversarial. Additional information on the TTP program and the iterative process used can be found in Appendix A - TTP Program Overview.

97 MATHEMATICS AND COMPUTING↗

Report on the comparison of the scan strategies employed by the Patrick Air Force Base WSR-74C/McGill radar and the NWS Melbourne WSR-88D radar

The objective of this investigation is to determine whether the current standard WSR-88D radar (NEXRAD) scan strategies permit the use of the Melbourne WSR-88D to perform the essential functions now performed by the Patrick Air Force Base (PAFB) WSR-74C/McGill radar for evaluating shuttle weather flight rules (FR) and launch commit criteria (LCC). To meet this objective, the investigation compared the beam coverage patterns of the WSR-74C/McGill radar located at PAFB and the WSR-88D radar located at the Melbourne National Weather Service (NWS) Office over the area of concern for weather FR and LCC evaluations. The analysis focused on beam coverage within four vertical 74 km radius cylinders (1 to 4 km above ground level (AGL), 4 to 8 km AGL, 8 to 12 km AGL, and 1 to 12 km AGL) centered on Kennedy Space Center (KSC) Launch Complex 39A. The PAFB WSR-74C/McGill radar is approximately 17 km north-northeast of the Melbourne WSR-88D radar. The beam coverage of the WSR-88D using VCP 11 located at the Melbourne NWS Office is comparable (difference in percent of the atmosphere sampled between the two radars is 10 percent or less) within the area of concern to the beam coverage of the WSR-74C/McGill radar located at PAFB. Both radars provide good beam coverage over much of the atmospheric region of concern. In addition, both radars provide poor beam coverage (coverage less than 50 percent) over limited regions near the radars due to the radars' cone of silence and gaps in coverage within the higher elevation scans. Based on scan strategy alone, the WSR-88D radar could be used to perform the essential functions now performed by the PAFB WSR-74C/McGill radar for evaluating shuttle weather FR and LCC. Other radar characteristics may, however, affect the decision as to which radar to use in a given case.

Taylor, Gregory↗

Experiment To Test Raster Scanning With RUM Actuator

Report describes proposed experiment to demonstrate feasibility of using rotating-unbalanced-mass (RUM) actuator to effect raster scanning of instrument mounted in two-axis gimbal. Conceptual RUM and auxiliary RUM control mechanism described in "Auxiliary Mechanisms for Rotating-Unbalanced-Mass Actuators" (MFS-28817).

Lightsey, W. D.↗

SU-E-T-815: In Vivo Dosimetry and Daily Arc Junction Verification Using EBT3 Gafchromic Film for Pediatric Cranio-Spinal Irradiation

Purpose: Perform dosimetric comparison between planned and delivered dose in the junction area, measure daily dose variation in the arc junction area for pediatric patients treated for medulloblastoma using Craniospinal axis irradiation(CSI) Material and methods Dose comparison in the junction area, daily dose variation in the arc junction area for a Rando Phantom and 5 pediatric patients treated using CSI technique were analyzed. Plans were created using the Eclipse treatment planning system. Two arcs for cranium and 1 arc for spine region were used. Planar dose matrix was created by projecting phantom and patient plan into the ArcCheck phantom. EBT3 film was placed in the middle of ArcCheck plug to measure dose distribution in the junction areaDuring patient treatment, strip of EBT3 film was placed daily at each junction area for verification. EBT3 films were scanned using a flatbed scanner, Epson Expression 10000 XL. Film QA pro software was used to analyze film. Scanning and analysis was performed according to vendor recommendations and AAPM TG-55 report. Films were scanned and analyzed daily after each treatment and at the end of treatment course. Planar dose distributions from films were compared with planar dose distribution from treatment planning system. Results: Comparison of planned vs. measured dose distributions for patients have passing rates of 90%–100% with 3% and 3 mm gamma analysis. In some of the treatment fractions, daily setup film showed variation in dose distribution in the junction area. Conclusion: It is critical to measure dose distribution in the arc junction area and use additional quality assurance measures to verify daily setup for CSI patient where one or more junctions are present. EBT3 film prove to be a good tool to achieve this task considering flexibility associated with the film such as symmetry, self-developing and ease of use.

60 APPLIED LIFE SCIENCES↗

Imaging charge carriers in potential-induced degradation defects of c-Si solar cells by scanning capacitance microscopy

We report on nm-resolution imaging of charge-carrier distribution around local potential-induced degradation (PID) shunting defects using scanning capacitance microscopy. We imaged on cross sections of heavily field-degraded module areas, cored out and selected by mm-scale photoluminescence imaging. We found localized areas with abnormal carrier behavior induced by the PID defects: the apparent n-type carrier extends vertically into the absorber to ~1-2 um from the cell surface, and laterally in similar lengths; in defect-free areas, the n-type carrier extends ~0.5 um, which is consistent with the junction depth. For comparison, we also investigated areas of the same module exhibiting the least PID stress, and we found no such heavily damaged junction area. Instead, we found slightly abnormal carrier behavior, where the carrier-type inversion in the absorber did not occur, but the p-type carrier concentration changed slightly in a much smaller lateral length of ~300 nm. These nano-electrical findings may indicate a possible mechanism that the existing extended defects, which may not be significantly harmful to cell performance, can be changed by PID to heavily damaged junction areas.

14 SOLAR ENERGY↗

Far-infrared scans of the Galactic plane

Results are reported for balloon-borne scans of the Galactic plane between longitudes of 348 and 32.5 deg, which were made in two broad spectral bands from 60 to 300 microns and from 150 to 300 microns. These results indicate that there are many bright H II regions embedded in a diffuse underlying band of emission in the examined longitude range, that the color temperatures range from 30 to 90 K, and that the width of the plane is at least 2 deg of arc in both spectral bands. A lower-limit IR luminosity of the order of 1 billion suns is computed for both the bright complex of sources at the nucleus and the underlying diffuse emission out to about + or -15 deg of arc from the nucleus. The strong relationship between far-IR emission and radio continuum expected for discrete sources is illustrated, and the results are compared with those of previous studies. It is concluded that the total far-IR luminosity of the central part of the Galaxy is understandable solely in terms of known distributions of stars and dust.

Low, F. J.↗

Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low noise, low heat dissipation, high gain AC-DC front end amplification for scanning probe microscopy.

We report here on the design, construction and testing of a vacuum compatible AC-DC amplification system for low signal measurements with scanning probes. The most important feature of this new amplification system is incorporated within the head of a scanning tunneling microscope (STM). This is achieved with a very low thermal dissipation radio frequency amplifier at the STM head. The amplifier gain is higher than 40 dB and has a 50 dB maximum. Further, the AC noise figure is 0.7 dB between 100 and 1000 MHz. The noise induced in the DC amplifier is less than 2 pA RMS (root mean square), which enables the microscope to scan over soft insulating molecular layers. Thermal drift at the STM tip-sample interface is below 0.1 nm min{sup -1} both in air and in vacuum operation. Atomic resolution on highly oriented pyrolytic graphite surfaces is reliably achieved. Spin noise measurements are provided as an example of an application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two-Color Ultrafast Photoexcited Scanning Tunneling Microscopy

We report on two-color two-photon photoexcitation of a metal surface driven by ultrafast laser pulses and detected with a scanning tunneling microscope (STM) tip as a proximate anode. Results are presented for two cases: (i) where the tip is retracted from the surface far enough to prohibit tunneling, and (ii) where the tip is within tunneling range of the surface. A delay-modulation technique is implemented to isolate the two-color photoemission from concurrent one-color two-photon photoemission and provide subpicosecond time-resolved detection. When applied with the tip in tunneling range, this approach effectively isolates the two-photon photoexcited current signal from the conventional tunneling current and enables subpicosecond time-resolved detection of the photoexcited surface electrons. The advantage of the two-color approach is highlighted by comparison with the one-color case where optical interference causes thermal modulation of the STM tip length, resulting in tunneling current modulations that are orders of magnitude larger than the current due to photoexcitation of surface electrons. By completely eliminating this interference, and thereby avoiding thermal modulation of the STM tip length, the two-color approach represents an important step toward the ultimate goal of simultaneous subnanometer and subpicosecond measurements of surface electron dynamics by ultrafast-laser-excited STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Southeast-PA-Diabase

Computed tomography and high-resolution core log data associated with the technical report "Computed Tomography Scanning and Geophysical Measurements of the Southeastern Pennsylvania Triassic Diabase Core" Schmitt, R.; Paronish, T.; Crandall, D.; Moore, J.; Neubaum, J.; Andrews, G. "Computed Tomography Scanning and Geophysical Measurements of the Southeastern Pennsylvania Triassic Diabase Core; DOE.NETL-2021.2843; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2021; p 104

Computed Tomography↗

Vibrational spectroscopic evidence for (NO){sub 3} formation on Cu(111)

The formation of (NO){sub 3} on Cu(111) was recently reported based on scanning tunneling microscopy observations [A. Shiotari et al., J. Chem. Phys. 141, 134705 (2014)]. We herein report studies into this system using electron energy loss spectroscopy and verify the above findings through vibrational analysis. For the surface covered with mixed isotopes of N{sup 16}O and N{sup 18}O, we observed four peaks corresponding to N-O stretching vibrations, which were ascribed to the four isotopic combinations of the trimer. Dynamic coupling within the trimer was evaluated from model calculations of the coupled oscillators. Furthermore, we observed hindered rotation and translation modes in the dipole scattering regime, suggesting that the molecular axis is tilted from the surface normal. These results provide spectroscopic support for the formation of (NO){sub 3} on Cu(111).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A conceptual thermal design study of an electronically scanned thinned array radiometer

This report describes conceptual thermal design study for an Electronically Scanned Thinned Array Radiometer (ESTAR). ESTAR is an instrument concept for the measurement of soil moisture from space using synthetic aperture radiometry. The thermal design goal is to minimize the orbital temperature variation of the radiometer receivers using established materials and techniques. Two design approaches have been investigated; the first uses the waveguide as a heat sink, and the second uses a nadir facing radiator on the receiver assembly. The second approach minimizes the receiver's impact on the waveguide temperatures. Predicted temperatures for all receivers are presented for the two cases indicating the transient thermal environments the receivers would experience during an orbit. In addition, the effects of the receiver heat dissipation on the waveguide temperatures are shown.

Gould, D. C.↗

Chemical Silver Coating of Fiber Tips in Near-Field Scanning Optical Microscopy

We report what is believed to be the first experimental demonstration of silver coating by a wet chemical process on tapered fiber tips used in near-field scanning optical microscopy. The process is at room temperature and pressure and takes only a few minutes to complete. Many tips can be simultaneously coated.

Vikram, Chandra S.↗

Scanning radiometer for measurement of forward-scattered light to determine mean diameter of spray particles

A scanning radiometer is reported that measures forward-scattered light to determine the mean diameter of spray particles. An optical scanning method gives a continuous measurement of the light-scattering angle during spray nozzle tests. A method of calibration and a correction for background light are presented. Mean particle diameters of 10 to 500 micrometers can be measured.

Buchele, D. R.↗