The Grain Boundary Relaxation (GBR) Approach for Manufacturing High Strength Nanocrystalline Lightweight Metals

The overarching goal of the project was to conduct research and development work as proposed in the Statement of Project Objective (SOPO) of the award document DE-FE-0009116. The project had 4 tasks and 12 milestones. All the milestone deliverables were completed. The accomplishments of the project objectives and technical discussions are described in Sections 3 and 4, respectively. The modeling and simulation work indicated that to increase the strength and stability of nanocrystalline aluminum (Al), selection of dopants, such as Mg, is necessary. It was predicted that the crystallite size should be less than 50 nm to give high strength. On the basis of modeling, cryo-milling of Al was conducted with the addition of Mg as a function of different times. The crystallite size of the cryo-milled powders was determined by XRD and TEM. Both measurements showed that the actual crystallite size of the grain was <40 nm. The thermal stability of the grain size was established as a function of temperature. It was established that the grain size was < 50 nm up to 500C. The crystallite size of the bulk sample prepared by spark plasma sintering (SPS) and cold spray (CS) additive manufacturing was less than <40 nm. The mechanical properties of the bulk samples prepared by SPS and CS, showed excellent microhardness, good tensile properties (>200 MPa) with moderate ductility and improved fatigue performance. Adding yttria stabilized zirconia (YSZ) improved the build thick of the CS sample, however the YSZ was getting embedded into the sample. A highly dense SPS samples sent for 3rd party testing to the Innovation Testing Services showed a minimum hardness of 180 HV with an average tensile strength of 512.5 MPa. The high cycle fatigue tests also showed an endurance limit of 179.5 MPa. The Energy cost evaluations showed an overall energy cost of around $\$$17.05 for the cryomilling and SPS processes and the total manufacturing cost calculations of $\$$78.14 for 1 kg of sample. The energy cost to prepare a Kg of CS sample is $\$$17.60 and the overall manufacturing cost is $\$$86.85.

36 MATERIALS SCIENCE↗

Metabolite, Protein, and Lipid Extraction (MPLEx): a method that simultaneously inactivates Middle East respiratory syndrome coronavirus and allows analysis of multiple host cell components following infection

Mass spectrometry (MS)-based, integrated proteomics, metabolomics, and lipidomics (collectively, multi-omics) studies provide a very detailed snap shot of virus-induced changes to the host following infection and can lead to the identification of novel prophylactic and therapeutic targets for preventing or lessening disease severity. Multi-omics studies with Middle East respiratory syndrome coronavirus (MERS-CoV) are challenging as the requirements of Biosafety Level 3 containment limit the numbers of samples that can be safely managed. To address these issues, the multi-omics sample preparation technique MPLEx (metabolite, protein, and lipid extraction) was developed to partition a single sample into three distinct parts (metabolites, proteins and lipids) for multi-omics analysis, while simultaneously inactivating MERS-CoV by solubilizing and disrupting the viral envelope and denaturing viral proteins. Here we describe the MPLEx protocol, highlight the step of inactivation, and describe the details of downstream processing, instrumental analysis of studies with Middle East respiratory syndrome coronavirus (MERS-CoV) are challenging as the requirements of Biosafety Level 3 containment limit the numbers of samples that can be safely managed. To address these issues, the multi-omics sample preparation technique MPLEx (metabolite, protein, and lipid extraction) was developed to partition a single sample into three distinct parts (metabolites, proteins and lipids) for multi-omics analysis, while simultaneously inactivating MERS-CoV by solubilizing and disrupting the viral envelope and denaturing viral proteins. Here we describe the MPLEx protocol, highlight the step of inactivation, and describe the details of downstream processing, instrumental analysis of the three separate analytes and their subsequent informatics pipelines.

Nicora, Carrie D.↗

[EC5-Space Suit Assembly Team- Internship]

There were three main projects in this internship. The first pertained to the Bearing Dust Cycle Test, in particular automating the test to allow for easier administration. The second concerned modifying the communication system setup in the Z2 suit, where speakers and mics were adjusted to allow for more space in the helmet. And finally, the last project concerned the tensile strength testing of fabrics deemed as candidates for space suit materials and desired to be sent off for radiation testing. The major duties here are split up between the major projects detailed above. For the Bearing Dust Cycle Test, the first objective was to find a way to automate administration of the test, as the previous version was long and tedious to perform. In order to do this, it was necessary to introduce additional electronics and perform programming to control the automation. Once this was done, it would be necessary to update documents concerning the test setup, procedure, and potential hazards. Finally, I was tasked with running tests using the new system to confirm system performance. For the Z2 communication system modifications, it was necessary to investigate alternative speakers and microphones which may have better performance than those currently used in the suit. Further, new speaker and microphone positions needed to be identified to keep them out of the way of the suit user. Once this was done, appropriate hardware (such as speaker or microphone cases and holders) could be prototyped and fabricated. For the suit material strength testing, the first task was to gather and document various test fabrics to identify the best suit material candidates. Then, it was needed to prepare samples for testing to establish baseline measurements and specify a testing procedure. Once the data was fully collected, additional test samples would be prepared and sent off-site to undergo irradiation before being tested again to observe changes in strength performance. For the Bearing Dust Cycle Test, automation was achieved through use of a servo motor and code written in LabVIEW. With this a small electrical servo controller was constructed and added to the system. For the Z2 communication modifications speaker cases were developed and printed, and new speakers and mics were selected. This allowed us to move the speakers and mics to locations to remain out of the suit users way. For the suit material strength testing, five material candidates were identified and test samples were created. These samples underwent testing, and baseline test results were gathered, though these results are currently being investigated for accuracy. The main process efficiency developed during the course of this internship comes from automation of the Bearing Dust Cycle Test. In particular, many hours of human involvement and precise operation are replaced with a simple motor setup. Thus it is no longer required to man the test, saving valuable employee time. This internship has confirmed a few things for me, namely that I both want to work as an engineer for an aerospace firm and that in particular I want to work for the Johnson Space Center. I am also confirmed in my desire to work with electronics, though I was surprised to enjoy prototyping 3D CAD design as much as I did. Therefore, I will make an effort to build my skills in this area so that I can continue to design mechanical models. In fact, I found the process of hands-on prototyping to be perhaps the most fun aspect of my time working here. This internship has also furthered my excitement for continual education, and I will hopefully be pursuing a masters in my field in the near future.

Maicke, Andrew↗

System Would Acquire Core and Powder Samples of Rocks

A system for automated sampling of rocks, ice, and similar hard materials at and immediately below the surface of the ground is undergoing development. The system, denoted a sample preparation, acquisition, handling, and delivery (SPAHD) device, would be mounted on a robotic exploratory vehicle that would traverse the terrain of interest on the Earth or on a remote planet. The SPAHD device would probe the ground to obtain data for optimization of sampling, prepare the surface, acquire samples in the form(s) of cores and/or powdered cuttings, and deliver the samples to a selected location for analysis and/or storage.

Bar-Cohen, Yoseph↗

Facile One-Pot Nanoproteomics for Label-Free Proteome Profiling of 50–1000 Mammalian Cells

Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.

59 BASIC BIOLOGICAL SCIENCES↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

Handheld Biosensor for COVID-19 Screening

We have made significant progress toward the development of an integrated nucleic acid amplification system for Autonomous Medical Devices Incorporated (AMDIs) Optikus handheld diagnostic device. In this effort, we developed a set of loop-mediated isothermal amplification (LAMP) primers for SARS-CoV-2 and then demonstrate amplification directly on a surface acoustic wave (SAW) sensor. We built associated hardware and developed a C-code to control the amplification process. The goal of this project was to develop a nucleic amplification assay that is compatible with SAW sensors to enable both nucleic and serological testing in a single handheld diagnostic device. Toward this goal, AMDI is collaborating Sandia National Laboratories to develop a rapid, portable diagnostic screening device that utilizes Sandias unique surface acoustic wave biosensor (SAW) for COVID-19 detection. Previously, the SANDIA- AMDI SAW sensor has successfully detected multiple high-profile bacteria viruses, including Ebola, HIV, Sin Nombre, and Anthrax. Over the last two years, AMDI and SANDIA have significantly improved the sensitivity and detection capability of the SAW biosensor and have also developed a modular hand-held, portable platform called the Optikus, which uses CD microfluidics and handheld instrumentation to automate all sample preparation, reagent introduction, sample delivery, and measurement for a number of different assay targets. We propose to use this platform for the development of a rapid (%3C30 minutes), point-of-care diagnostic test for detection of COVID-19 from nasal swab samples.

47 OTHER INSTRUMENTATION↗

Field Scoping Study of Gamma-Ray Measurement of UF 6 Cristillini Samples with CZT and HPGe Detectors

A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF 6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Downhole Elemental Analysis with LIBS

In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a vertical stage; a second actuator at the top of the downhole probe allows radial scanning of the borehole. Analysis of iron and titanium in lunar simulant with LIBS was performed in air using the method of standard addition. The results for lunar simulant NU-LHT-2M show a value for the concentration of iron ranging between 2.29% and 3.05% depending on the atomic line selected. The accepted value for the sample analyzed is 2.83%, showing the capability for the system in development to provide qualitative and semi-quantitative analysis in real-time.

Moreschini, Paolo↗

Rust Contamination from Water Leaks in the Cosmic Dust Lab and Lunar and Meteorite Thin Sections Labs at Johnson Space Center

On the early morning of September 15th, 2016, on the first floor of Building 31 at NASA-Johnson Space Center, the hose from a water chiller ruptured and began spraying water onto the floor. The water had been circulating though old metal pipes, and the leaked water contained rust-colored particulates. The water flooded much of the western wing of the building's ground floor before the leak was stopped, and it left behind a residue of rust across the floor, most notably in the Apollo and Meteorite Thin Section Labs and Sample Preparation Lab. No samples were damaged in the event, and the affected facilities are in the process of remediation. At the beginning of 2016, a separate leak occurred in the Cosmic Dust Lab, located in the same building. In that lab, a water leak occurred at the bottom of the sink used to clean the lab's tools and containers with ultra-pure water. Over years of use, the ultra-pure water eroded the metal sink piping and leaked water onto the inside of the lab's flow bench. This water also left behind a film of rusty material. The material was cleaned up and the metal piping was replaced with PVC pipe and sealed with Teflon plumber's tape. Samples of the rust detritus were collected from both incidents. These samples were imaged and analyzed to determine their chemical and mineralogical compositions. The purpose of these analyses is to document the nature of the detritus for future reference in the unlikely event that these materials occur as contaminants in the Cosmic Dust samples or Apollo or Meteorite thin sections.

Kent, J. J.↗

Physical and Biological Properties of Cobalt- and Copper-Doped Calcium Phosphates as Bone Substitute Materials

Arthritis, osteoporosis, and other bone diseases and defects are common medical issues worldwide. By utilizing ceramic biomaterials as bone substitutes to treat these diseases, bone regeneration can be promoted and toxicity from the substitute material can be limited. Calcium phosphate (CaP) ceramics have become popular as bone substitutes due to their biocompatibility and similarity in composition to natural bone. The purpose of this research was to investigate the physical properties and biological responses of CaP-based bone substitutes, doped with metal ions. Some metal ions are present in natural bone in small amounts, and recent studies show they affect the biological responses of CaPs significantly. Dopants such as magnesium (Mg), strontium (Sr), silicon (Si) and iron (Fe) alter the phase composition, mechanical properties, osteogenesis and angiogenesis properties of CaPs, depending on their concentration and method of addition. In the present study, the effects of cobalt (Co) and copper (Cu) on the physical and biological properties of two main CaP materials, brushite cement (BrC) and tricalcium phosphate (TCP), have been investigated. Different concentrations of dopants in forms of oxide and/or chloride were selected and their effect on phase composition, sintering behavior, density, setting time, compressive strength and in vitro interaction with osteosarcoma and osteoblast cells were studied. Different techniques of sample preparation, challenges during cement preparation and compact sample pressing, sintering, and methods of dopant addition are discussed. The presence of Cu in tricalcium phosphate was found to increase thermal stability of the material and decrease the impact of sintering temperature on porosity. In addition, Cu caused a reduction in expression of inflammatory gene markers by human osteoblast cells and an increased expression at early time points due of osteoinductive markers.The addition of Cu and Co to brushite cement caused an increase in thermal stability of the material, and the addition of Cu caused significant increase in setting time. Small dopant amounts of Co caused decrease in setting time, but higher amounts caused an increase. In addition, Cu dopant in small amounts resulted in an increase of compressive strength. Both Cu and Co led to a decrease in expression of inflammatory gene markers by osteoblast and osteosarcoma cells respectively, and Cu also caused an increase in osteoinductive marker expression. Thus, these results indicate that Cu and Co have a positive impact on the physical, mechanical and biological properties of calcium phosphate biomaterials.

Cummings, Haley V.↗

Micro- and nano-scale techniques to explore bacteria and fungi interactions with silicate minerals

Biogeochemical interfaces such as bacteria-mineral, fungi-mineral, and water-mineral are hot spots for important processes and reactions in all environments. Studying these interfaces are useful over a range of spatial and temporal scales in order to understand elemental cycles, soil formation, restoration, and bioremediation. Advancement of micro- and nano-scale techniques lead to new discoveries about reactions and interactions at the heterogeneous interface of bacteria, fungi, and minerals. The current state-of-art of analytical techniques allows to study solid, liquid, and gas phases and their interactions with biological components and often permits simultaneous study of chemical and physical properties in a site-specific manner. Improved techniques not only increased spatial and temporal resolution with site specificity but also decreased sample preparation, artifact generation, sample size requirements and analytical time. There are limitations and challenges that still need to be overcome while studying the very heterogeneous microbe-mineral interface, but improved accessibility to beam time at the synchrotron facilities and instrument time at the user laboratories offer some solutions. This review chapter focuses on a subset of the available micro- and nano-scale techniques: electron and atomic force microscopy, and X-ray based spectroscopy of traditional and synchrotron-based applications.

Slicate minerals, microscopy, microbes↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

High efficiency active environmental sampling of chemical traces

A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).

Junghans, Ann↗

The sensitive surface chemistry of Co-free, Ni-rich layered oxides: identifying experimental conditions that influence characterization results

Recent studies have suggested that Co-free, Ni-rich layered cathodes (e.g., doped LiNiO2) can provide promising battery performance for practical applications. However, these layered cathodes suffer from significant surface instability during various stages of the sample history, which generates inherent challenges for achieving stable battery performance and obtaining statistically representative characterization results. To reliably report the surface chemistry of these materials, delicate controls of stepwise sample preparation are required. In this study, we aim to reveal how the surface chemistry of LiNiO2 based materials changes with various environments, including human exhalation, sample storage, sample preparation, electrochemistry cycling, and surface doping. Our results demonstrate that the surface of these materials is highly reactive and prone to alter at various stages of sample handling and characterization. The sensitive surface could impact the interpretation of the surface chemical and structural information, including surface carbonate formation, transition metal reduction and dissolution, and surface reconstruction. Importantly, the heterogeneity of the surface degradation calls for a consolidation of nanoscale, high-resolution characterization, and ensemble-averaged methods in order to improve statistical representation. Furthermore, the doping chemistry can effectively mitigate the surface degradation and improve overall battery performance due to the enhanced surface oxygen retention. Our study highlights the necessity of strict measurements through complementary characterizations at multiple length scales to eliminate unintentional biased conclusions.

surface chemistry, Co-free Ni-rich cathodes, Istab↗

Stardust Interstellar Preliminary Examination II: Curating the Interstellar Dust Collector, Picokeystones, and Sources of Impact Tracks

We discuss the inherent difficulties that arise during "ground truth" characterization of the Stardust interstellar dust collector. The challenge of identifying contemporary interstellar dust impact tracks in aerogel is described within the context of background spacecraft secondaries and possible interplanetary dust particles and beta-meteoroids. In addition, the extraction of microscopic dust embedded in aerogel is technically challenging. Specifically, we provide a detailed description of the sample preparation techniques developed to address the unique goals and restrictions of the Interstellar Preliminary Exam. These sample preparation requirements and the scarcity of candidate interstellar impact tracks exacerbate the difficulties. We also illustrate the role of initial optical imaging with critically important examples, and summarize the overall processing of the collection to date.

Dust↗