Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of the time-integrated C P asymmetry in D 0 → K S 0 K S 0 decays using Belle and Belle II data

We measure the time-integrated C P asymmetry in D 0 → K S 0 K S 0 decays reconstructed in e + e − → c c ¯ events collected by the Belle and Belle II experiments. The corresponding data samples have integrated luminosities of 980 and 428 fb − 1 , respectively. The D 0 decays are required to originate from the D * + → D 0 π + decay, which determines the charm flavor at production time. A control sample of D 0 → K + K − decays is used to correct for production and detection asymmetries. The result, ( − 1.4 ± 1.3 ( stat ) ± 0.1 ( syst ) ) % , is consistent with previous determinations and with C P symmetry. Published by the American Physical Society 2025

Adachi, I. (ORCID:0000000322870173)↗

Measurement of the time-integrated 𝐶⁢𝑃 asymmetry in 𝐷 0 → 𝐾$^{0}_{S}$𝐾$^{0}_{S}$ decays using opposite-side flavor tagging at Belle and Belle II

We measure the time-integrated 𝐶⁢𝑃 asymmetry in 𝐷 0 → 𝐾$^{0}_{S}$𝐾$^{0}_{S}$ decays reconstructed in 𝑒 + ⁢𝑒 − → $c\bar{c}$ events collected by the Belle and Belle II experiments. The corresponding data samples have integrated luminosities of 980 and 428 fb −1 , respectively. To infer the flavor of the 𝐷 0 meson, we exploit the correlation between the flavor of the reconstructed decay and the electric charges of particles reconstructed in the rest of the 𝑒 + ⁢𝑒 − → $c\bar{c}$ event. This results in a sample which is independent from any other previously used at Belle or Belle II. The result, 𝐴 𝐶⁢𝑃 ⁡(𝐷 0 → 𝐾$^{0}_{S}$𝐾$^{0}_{S}$)=(1.3±2.0±0.2)%, where the first uncertainty is statistical and the second systematic, is consistent with previous determinations and with 𝐶⁢𝑃 symmetry.

CP violation↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High temperature flow-through device for rapid solubilization and analysis

Devices and methods for thermally lysing of biological material, for example vegetative bacterial cells and bacterial spores, are provided. Hot solution methods for solubilizing bacterial spores are described. Systems for direct analysis are disclosed including thermal lysers coupled to sample preparation stations. Integrated systems capable of performing sample lysis, labeling and protein fingerprint analysis of biological material, for example, vegetative bacterial cells, bacterial spores and viruses are provided.

59 BASIC BIOLOGICAL SCIENCES↗

High temperature flow-through device for rapid solubilization and analysis

Devices and methods for thermally lysing of biological material, for example vegetative bacterial cells and bacterial spores, are provided. Hot solution methods for solubilizing bacterial spores are described. Systems for direct analysis are disclosed including thermal lysers coupled to sample preparation stations. Integrated systems capable of performing sample lysis, labeling and protein fingerprint analysis of biological material, for example, vegetative bacterial cells, bacterial spores and viruses are provided.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization of the first order gradiometer for small sample magnetization measurements using pulse integrating magnetometer

In the paper we present an analytical calculation method for determination of the sensitivity of a pulse field magnetometer working with a first order gradiometer. Our considerations here are especially focused on a case of magnetic moment measurements of very small samples. Derived in the work analytical equations allow for a quick estimation of the magnetometer's sensitivity and give also the way to its calibration using the sample simulation coil method. On the base of the given in the paper calculations we designed and constructed a simple homemade magnetometer and performed its sensitivity calibration.

36 MATERIALS SCIENCE↗

The Velociprobe: An ultrafast hard X-ray nanoprobe for high-resolution ptychographic imaging

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 x 10 4 resolution elements per second

36 MATERIALS SCIENCE↗

Assessment of Tritium Activities in Bailed versus Pumped Samples from Wells at the Nevada National Security Site

The Underground Test Area (UGTA) Activity uses a variety of methods to collect groundwater samples to identify radionuclide migration from underground nuclear tests. These include depth-discrete bailing, pumping with low-volume rod pumps, and pumping with electrical submersible pumps. The Nevada National Security Site (NNSS) Integrated Groundwater Sampling Plan specifies that when sampling with a pump, a minimum of three effective well volumes are withdrawn and then samples are collected after water-quality parameters have stabilized. In locations where pumping is not feasible, depth-discrete bailing is used and purging prior to sampling is usually not required. A recent study evaluated three sampling technologies and recommended that historical tritium results be evaluated where both pumped and bailed samples are available to identify preferred sampling protocols for the collection of tritium samples. The tritium ( 3 H) activities were obtained from the UGTA chemistry data base. Wells were identified with known 3 H activities above method detection limits, and then evaluated if both bailed and pumped samples had been collected. Twenty two wells and piezometers with bailed samples, pumped samples, and 3 H activities above background were identified for further consideration. The conclusions from this analysis are: Bailed samples collected for 3 H analysis near the water surface in a well are lower in 3 H activity than bailed samples from within screened intervals and pumped samples. Depth-discrete bailed samples from within the screened intervals are generally in good agreement with pumped samples from developed wells and piezometers. Depth-discrete bailed samples from undeveloped wells and piezometers are in good agreement with the first pumped samples. However, the next pumped samples increased in 3 H activity, resulting in a greater percent difference between the undeveloped bailed samples and later pumped samples. Continuous pumping over extended periods removing large purge volumes from wells can perturbate the surrounding groundwater system for long periods of time. These perturbations can cause large changes in 3 H activities in the aquifer near the well because of the mixing of groundwater with variable 3 H activities. Recommendations include: Bailed samples for 3 H should not be collected near the water surface in the well. Bailed samples should be collected from within the well screen. Logs of temperature, chemistry, and thermal flow should be evaluated to identify optimal depths within the well screen to collect depth-discrete bailer samples. Purging of large volumes of water from the well over extended periods of time should be avoided when collecting 3 H samples. Sufficient time should be allowed after pumping large volumes of water from the well (e.g., after well development) for the surrounding aquifer and 3 H activities to return to ambient conditions

54 ENVIRONMENTAL SCIENCES↗

The top quark, others new phenomena observed at the CDF in {ie359-1} collisions at √s = 1.96 TeV (Review)

Upgraded Tevatron luminosity in Run-II (started 2001) has opened a new level of modern heavy-quark studies compared to that one of Run-I. Now top event samples contain hundreds of event statistics for investigation. This review mainly covers the mass measurements of the top quark produced at √s = 1.96 TeV in {ie359-2} collisions at the Collider Detector of Fermilab with the integrated luminosity samples up to 1 fb{sup −1}. As an example of the top quark mass measurements we consider so-called Matrix Element method in “lepton + jets” and “dilepton” channels of the top-quark decay. The CDF top quark mass obtained in lepton +jets mode is the world most precise single measurement of this important physics parameter. The review summarizes the essential results of the CDF top-quark mass measurement achieved and published for the recent 2003–2008 period. We consider also b-quark baryon discoveries like Σ{sub b }, Σ{sup *}{sub b }, Θ{sub b }as well as first observation of {ie359-3} oscillations. Let us mention here that a CDF/JINR-group created significant contribution to the new CDF complex and physics investigation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydrophysical Evaluation of Wells TW-B, TW-7, UE-6d, U-2gg PSE 3A, U-10L 1, and UE-6e in Yucca Flat

This study evaluated six wells in Yucca Flat in support of the Underground Test Area (UGTA) Activity conducted by the U.S. Department of Energy (DOE) at the Nevada National Security Site (NNSS). Accessibility and groundwater sampling conditions were assessed and if conditions permitted, samples were collected for tritium analysis. Four of the wells, TW-B, UE-6d, UE-6e, and TW-7 were sampled in support of UGTA responses to recommendations made by the Yucca Flat/Climax Mine External Peer Review Committee (Navarro, 2016). In addition to its role in support of these responses, TW-7 was included because it is listed in the NNSS Integrated Groundwater Sampling Plan (DOE, 2014) as a required sampling location, although it had not been sampled since 1994. U-2gg PSE 3A and U-10L 1 were evaluated to determine whether deteriorating well conditions can be addressed so that these wells can be used as additional sampling points in Yucca Flat.

54 ENVIRONMENTAL SCIENCES↗

Soil gas probes for monitoring trace gas messengers of microbial activity

Abstract Soil microbes vigorously produce and consume gases that reflect active soil biogeochemical processes. Soil gas measurements are therefore a powerful tool to monitor microbial activity. Yet, the majority of soil gases lack non-disruptive subsurface measurement methods at spatiotemporal scales relevant to microbial processes and soil structure. To address this need, we developed a soil gas sampling system that uses novel diffusive soil probes and sample transfer approaches for high-resolution sampling from discrete subsurface regions. Probe sampling requires transferring soil gas samples to above-ground gas analyzers where concentrations and isotopologues are measured. Obtaining representative soil gas samples has historically required balancing disruption to soil gas composition with measurement frequency and analyzer volume demand. These considerations have limited attempts to quantify trace gas spatial concentration gradients and heterogeneity at scales relevant to the soil microbiome. Here, we describe our new flexible diffusive probe sampling system integrated with a modified, reduced volume trace gas analyzer and demonstrate its application for subsurface monitoring of biogeochemical cycling of nitrous oxide (N 2 O) and its site-specific isotopologues, methane, carbon dioxide, and nitric oxide in controlled soil columns. The sampling system observed reproducible responses of soil gas concentrations to manipulations of soil nutrients and redox state, providing a new window into the microbial response to these key environmental forcings. Using site-specific N 2 O isotopologues as indicators of microbial processes, we constrain the dynamics of in situ microbial activity. Unlocking trace gas messengers of microbial activity will complement -omics approaches, challenge subsurface models, and improve understanding of soil heterogeneity to disentangle interactive processes in the subsurface biome.

04 OIL SHALES AND TAR SANDS↗

Derivative-free stochastic optimization via adaptive sampling strategies

In this paper, we present a novel derivative-free framework for solving unconstrained stochastic optimization problems. Many problems in fields ranging from simulation optimization to reinforcement learning to quantum computing involve settings where only stochastic function values are obtained via a zeroth-order oracle, which has no available gradient information and necessitates the usage of derivative-free optimization methodologies. Our approach includes estimating gradients using stochastic function evaluations and integrating adaptive sampling techniques to control the accuracy in these stochastic approximations. Our framework encapsulates several gradient estimation techniques, including standard finite-difference, Gaussian smoothing, sphere smoothing, randomized coordinate finite-difference, and randomized subspace finite-difference methods. We provide theoretical convergence guarantees for our framework and analyze the worst-case iteration and sample complexities associated with each gradient estimation method. Finally, we demonstrate the empirical performance of the methods on logistic regression and nonlinear least squares problems.

Adaptive sampling↗

Characterization of the Triassic Newark Basin of New York and New Jersey for Geologic Storage of Carbon Dioxide

The project Characterization of the Triassic Newark Basin of New York and New Jersey for Geologic Storage of Carbon Dioxide is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. Sandia Technologies, LLC, and co-investigator Conrad Geoscience Corporation, examined the potential for large-scale, permanent CO2 storage in sedimentary strata within the Newark Rift Basin. The Newark Rift Basin underlies an industrialized, developed region comprising parts of New York, New Jersey, and Pennsylvania. The project characterized and investigated the suitability of Triassic age sedimentary formations for potential geologic CO2 storage. The project team drilled and cored two test wells to define the sedimentary geologic formations underlying the basin and to document or reach basement rock. With this geologic characterization phase, an integration of seismic, geologic, borehole, and formation core results provided a higher resolution assessment of CO2 storage potential. The Stockton Formation is known to be a potentially favorable geologic storage formation in the basin. In 2011, the 1-NYSTA Tandem Lot stratigraphic test well was drilled to a depth of 6,855 feet in the northern portion of the Newark Basin in southern New York State. Approximately 9 miles south-southeast on the Lamont Doherty Campus, TW-4 was drilled and cored in 2013 to a depth of 1,802 feet and contacted apparent igneous basement at a depth of 1,712 feet. Both wells penetrated the Palisades Sill ranging from 800 feet thick in the eastern well to approximately 1,800 feet in thickness at the 1-NYSTA Tandem Lot deep drill site. A diabase sill can provide an excellent seal and dense confining layer for potential CO2 storage reservoirs and flow layers that are situated beneath it within the Stockton Sandstone. The Stockton Sandstone was encountered beneath the sill in the TW-4 well on the Lamont campus, and data integration suggests that it was likely observed near total depth in the deep 1-NYSTA Tandem Lot well. The test wells confirm and define reservoirs are present beneath the sill and offer CO2 storage potential. The integration of geologic and reservoir characterization of well logs, formation cores, and formation fluids indicated Triassic age lacustrine playa lake and mudbank shales of the Upper Passaic Group can provide an effective seal for the porous and permeable underlying sandstone reservoir layers. This project acquired seismic data, drilled borehole well logs, acquired core samples, and integrated these findings to provide a better understanding of the subsurface geologic formations in the Newark Rift Basin. These findings have contributed to a higher degree of accuracy in predicting potential geologic storage opportunities, while refining geologic storage capacity estimates for the indicated reservoirs and flow units.

.las↗

Precision Compton polarimetry for the QWeak experiment at Jefferson Lab

The Q Weak experiment, scheduled to run in 2010-2012 in Hall C at Jefferson Lab, will measure the parity-violating asymmetry in elastic electron-proton scattering at 1.1 GeV to determine the weak charge of the proton, Q{sub Weak}{sup p} = 1 - 4 sin{sup 2} {theta}{sub W}. The dominant experimental systematic uncertainty will be the knowledge of the electron beam polarization. With a new Compton polarimeter we aim to measure the beam polarization with a statistical precision of 1% in one hour and a systematic uncertainty of 1%. A low-gain Fabry-Perot cavity laser system provides the circularly polarized photons. The scattered electrons are detected in radiation-hard diamond strip detectors, and form the basis for a coincidence trigger using distributed logic boards. The photon detector uses a fast, undoped CsI crystal with simultaneous sampling and integrating read-out. Coincident events are used to cross-calibrate the photon and electron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. An example method for operating an integrated thermal cycling system includes depositing samples into the integrated thermal cycling system that includes a thermal cycling device and an electronic interface. The thermal cycling device includes multiple wells to receive the samples to be thermally cycled, a thermoelectric cooling (TEC) element connected to the multiple wells, a substrate on which the TEC element is positioned, and a controller coupled to the TEC element. The multiple wells are positioned within the substrate that includes a thermally conductive ground positioned between adjacent wells. Supplying power to the integrated thermal cycling system, via the electronic interface, allows the multiple wells to exchange heat with the substrate and for each well to operate independently from other wells.

Beer, N. Reginald↗

CALIBRATING UV STAR FORMATION RATES FOR DWARF GALAXIES FROM STARBIRDS

Integrating our knowledge of star formation (SF) traced by observations at different wavelengths is essential for correctly interpreting and comparing SF activity in a variety of systems and environments. This study compares extinction corrected integrated ultraviolet (UV) emission from resolved galaxies with color–magnitude diagram (CMD) based star formation rates (SFRs) derived from resolved stellar populations and CMD fitting techniques in 19 nearby starburst and post-starburst dwarf galaxies. The data sets are from the panchromatic Starburst Irregular Dwarf Survey and include deep legacy GALEX UV imaging, Hubble Space Telescope optical imaging, and Spitzer MIPS imaging. For the majority of the sample, the integrated near-UV fluxes predicted from the CMD-based SFRs—using four different models—agree with the measured, extinction corrected, integrated near-UV fluxes from GALEX images, but the far-UV (FUV) predicted fluxes do not. Furthermore, we find a systematic deviation between the SFRs based on integrated FUV luminosities and existing scaling relations, and the SFRs based on the resolved stellar populations. This offset is not driven by different SF timescales, variations in SFRs, UV attenuation, nor stochastic effects. This first comparison between CMD-based SFRs and an integrated FUV emission SFR indicator suggests that the most likely cause of the discrepancy is the theoretical FUV–SFR calibration from stellar evolutionary libraries and/or stellar atmospheric models. We present an empirical calibration of the FUV-based SFR relation for dwarf galaxies, with uncertainties, which is ∼53% larger than previous relations.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray Emission Spectroscopy as an in Situ Diagnostic Tool for X-ray Crystallography of Metalloproteins Using an X-ray Free-Electron Laser

Serial femtosecond crystallography (SFX) using the ultrashort X-ray pulses from a X-ray free-electron laser (XFEL) provides a new way of collecting structural data at room temperature that allows for following the reaction in real time after initiation. XFEL experiments are conducted in a shot-by-shot mode as the sample is destroyed and replenished after each X-ray pulse, and therefore, monitoring and controlling the data quality by using in situ diagnostic tools is critical. To study metalloenzymes, we developed the use of simultaneous collection of X-ray diffraction of crystals along with X-ray emission spectroscopy (XES) data that is used as a diagnostic tool for crystallography, by monitoring the chemical state of the metal catalytic center. We have optimized data analysis methods and sample delivery techniques for fast and active feedback to ensure the quality of each batch of samples and the turnover of the catalytic reaction caused by reaction triggering methods. Here, we describe this active in situ feedback system using Photosystem II as an example that catalyzes the oxidation of H2O to O2at the Mn4CaO5active site. We used the first moments of the Mn Kβ1,3emission spectra, which are sensitive to the oxidation state of Mn, as the primary diagnostics. This approach is applicable to different metalloproteins to determine the integrity of samples and follow changes in the chemical states of the reaction that can be initiated by light or activated by substrates and offers a metric for determining the diffraction images that are used for the final data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗