Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ambient Metabolic Profiling and Imaging of Biological Samples with Ultrahigh Molecular Resolution using Laser Ablation Electrospray Ionization 21 Tesla FTICR Mass Spectrometry

Mass spectrometry (MS) has been an indispensable analytical tool in capturing the complexity and array of biomolecules within biological systems. However, conventional MS-based analytical workflows are limited in both throughput and measuring the native molecular state these systems, due in large part to sample handling and preparation. The development of ambient ionization methods capable of sampling directly from tissues circumvent many of these issues but requires the use of high-performance MS to resolve the molecular complexity within these samples. Herein, we demonstrate the unique combination of laser ablation electrospray ionization (LAESI) coupled with a 21 Tesla Fourier transform ion cyclotron resonance (21T-FTICR-MS) for MS imaging applications. This analytical platform provides isotopic fine structure information directly from native tissues, delivering a higher degree of confidence for molecular identification. The ability to capture and visualize the complex metabolic behavior of living organisms in situ is a bioanalytical grand challenge that has yet to be fully realized. Due to their excellent sensitivity and selectivity, mass spectrometry (MS)-based platforms offer a unique opportunity to characterize an array of biomolecules from a variety of biological samples.[1] One method in particular, MS imaging (MSI), has demonstrated the ability to simultaneously determine the spatial distributions for hundreds of biomolecules, e. g., metabolites, lipids, peptides, and xenobiotics, within complex biological systems simultaneously.[2-3] Matrix-assisted laser desorption/ionization (MALDI)-MSI remains the most common of these methods.[4] However, the application of an exogenous matrix, and the limited availability of commercial sources that operate under atmospheric pressure,[5] has significantly prohibited the ability of MALDI to be useful for biomolecular mapping of living systems. Ambient ionization methods that require minimal to no sample preparation, like desorption electrospray ionization (DESI and nano-DESI) and laser ablation electrospray ionization (LAESI), demonstrated the ability to spatially map biomolecule distributions within live organisms.

Mass Spectometry, fourier transform ion cyclostron↗

A Microfluidic DNA Library Preparation Platform for Next-Generation Sequencing

Next-generation sequencing (NGS) is emerging as a powerful tool for elucidating genetic information for a wide range of applications. Unfortunately, the surging popularity of NGS has not yet been accompanied by an improvement in automated techniques for preparing formatted sequencing libraries. To address this challenge, we have developed a prototype microfluidic system for preparing sequencer-ready DNA libraries for analysis by Illumina sequencing. Our system combines droplet-based digital microfluidic (DMF) sample handling with peripheral modules to create a fully-integrated, sample-in library-out platform. In this report, we use our automated system to prepare NGS libraries from samples of human and bacterial genomic DNA. E. coli libraries prepared on-device from 5 ng of total DNA yielded excellent sequence coverage over the entire bacterial genome, with .99% alignment to the reference genome, even genome coverage, and good quality scores. Furthermore, we produced a de novo assembly on a previously unsequenced multi-drug resistant Klebsiella pneumoniae strain BAA-2146 (KpnNDM). The new method described here is fast, robust, scalable, and automated. Our device for library preparation will assist in the integration of NGS technology into a wide variety of laboratories, including small research laboratories and clinical laboratories.

59 BASIC BIOLOGICAL SCIENCES↗

Self-sterilizing canister

Canister, originally conceived for remote sterilization of spacecraft packages, could be used terrestrially to handle samples in biologically hazardous environments. Multiwalled canister includes inner layer of pyrotechnic powder. For sterilization, electrically activated squib ignites powder, raising temperature of outer surface of canister to 230 degrees centigrade for several minutes. Thermal-buffer inner layer prevents inside temperature for exceeding 100 degrees centigrade to protect contents from damage. Samples in field hospitals and other emergency situations could also be handled by equipment.

Yang, L. C.↗

Fluence Uniformity Measurements in an Electron Accelerator Used for Irradiation of Extended Area Solar Cells and Electronic Circuits for Space Applications

It is common to have liquid crystal displays and electronic circuit boards with area sizes of the order of 20x20 sq cm on board of satellites and space vehicles. Usually irradiating them at different fluence values assesses the radiation damage in these types of devices. As a result, there is a need for a radiation source with large spatial fluence uniformity for the study of the damage by radiation from space in those devices. Kent State University s Program on Electron Beam Technology has access to an electron accelerator used for both research and industrial applications. The electron accelerator produces electrons with energies in the interval from 1 to 5 MeV and a maximum beam power of 150 kW. At such high power levels, the electron beam is continuously scanned back and forth in one dimension in order to provide uniform irradiation and to prevent damage to the sample. This allows for the uniform irradiation of samples with an area of up to 1.32 sq m. This accelerator has been used in the past for the study of radiation damage in solar cells (1). However in order to irradiate extended area solar cells there was a need to measure the uniformity of the irradiation zone in terms of fluence. In this paper the methodology to measure the fluence uniformity on a sample handling system (linear motion system), used for the irradiation of research samples, along the irradiation zone of the above-mentioned facility is described and the results presented. We also illustrate the use of the electron accelerator for the irradiation of large area solar cells (of the order of 156 sq cm) and include in this paper the electrical characterization of these types of solar cells irradiated with 5 MeV electrons to a total fluence of 2.6 x 10(exp 15) e/sq cm.

Uribe, Roberto M.↗

Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical/mineralogical makeup of organic host phases to help determine deposition and preservation factors. (4) Chemical Stratigraphy Analyze the fine spatial distribution and variation of key species with depth.

Mars↗

Advanced detector signal acquisition and electron beam scanning for high resolution SEM imaging

We report the advancement of materials science at the mesoscale requires improvements in both sampling volumes/areas and spatial resolution in order to make statistically significant measurements of microstructures that influence higher-order material properties, such as fatigue and fracture. Therefore, SEM-based techniques have become desirable due to improvements in imaging resolution, large sample handling capability, and flexibility for in-situ instrumentation. By using fast sampling of SEM electron detector signals, intrinsic beam scanning defects have been identified that are related to the response time of the SEM electron beam deflectors and electron detectors. Mitigation of these beam scanning defects using detector sampling approaches and an adaptive model for settling time is shown to produce higher resolution SEM images, at faster image acquisition times, with a means to quantify the different response functions for various beam deflectors and detectors including those for electrons and ions.

47 OTHER INSTRUMENTATION↗

Development of the XFP beamline for x-ray footprinting at NSLS-II

For over a decade, synchrotron-based footprinting studies at the NSLS X28C beamline have provided unique insights and approaches for examining the solution-state structures of large macromolecular assemblies, membrane proteins, and soluble proteins, for time-resolved studies of macromolecular dynamics, and most recently for in vivo studies of RNA-protein complexes. The transition from NSLS to NSLS-II has provided the opportunity to create an upgraded facility for the study of increasingly complex systems; progress on the development of the XFP (X-ray Footprinting for In Vitro and In Vivo Structural Studies of Biological Macromolecules) beamline at NSLS-II is presented here. The XFP beamline will utilize a focused 3-pole wiggler source to deliver a high flux density x-ray beam, where dynamics can be studied on the microsecond to millisecond timescales appropriate for probing biological macromolecules while minimizing sample perturbation. The beamline optics and diagnostics enable adaptation of the beam size and shape to accommodate a variety of sample morphologies with accurate measurement of the incident beam, and the upgrades in sample handling and environment control will allow study of highly sensitive or unstable samples. The XFP beamline is expected to enhance relevant flux densities more than an order of magnitude from that previously available at X28C, allowing static and time-resolved structural analysis of highly complex samples that have previously pushed the boundaries of x-ray footprinting technology. XFP, located at NSLS-II 17-BM, is anticipated to become available for users in 2016.

43 PARTICLE ACCELERATORS↗

Study of sample drilling techniques for Mars sample return missions

To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.

Mitchell, D. C.↗

Maximum Sample Temperature for Mars Sample Return: A Historical Perspective

Since the first Mars Sample Return (MSR) report published by the Jet Propulsion Laboratory (JPL) in 1974 [1], a series of panels, reports, and white papers have recognized the importance of sample temperature and offered an informed sample maximum temperature (henceforth SMT) limit for returning martian samples to Earth. The Mars Sample Handling and Requirements Panel (MSHARP, 1999) stated that "[t]he main issue in sample preservation is temperature" [2]. More recently, the Mars Exploration Program Analysis Group (MEPAG)'s "Science Priorities for Mars Sample Return" report (2008), declared that "[s]ignificant loss, particularly to biological studies, occurs if samples reach +50C for three hours", whereby "scientific objectives related to life goals could be seriously compromised" [3]. By contrast, the Mars 2020 mission has adopted a SMT of +60C as spelled out in Beaty et al., 2016 [4]. Samples will be collected and then deposited on the surface in sealed tubes for possible retrieval and return to Earth. Beaty et al. [4] calculates that the samples will experience maximum temperatures of ~+30 to +60C, depending on latitude. At present, there is no mission requirement for the measurement/data logging of sample temperature during this period. We will explore the history of martian SMTs, as they have been recorded since 1974 [1], effectively representing input across multiple generations of Mars scientists. Ten separate publications present SMTs for MSR samples [1-10]. One report [10] is for a mission concept specifically designed to exclude life detection investigations, and recommended an SMT of 50C. Another did not specify a temperature, recommending "Mars ambient temperature" [5]. Of the remaining eight, SMTs are given as: -30C [1], -20C [3], 60C [4], -73 to 41C depending on sample type [6], -40C [7], -43 to 13C depending on type [2,8], and -33C [9]. If we restrict the temperatures to samples highlighted in the Mars 2020 mission goals, i.e. organics-bearing and sedimentary rocks, then the average SMT is -28+/-39C (n=8). Applying a Dixon's Q Test at P=0.05 (two-tailed), the 60C SMT [4] fails with Q=0.602 versus Qcrit=0.526. Excluding the outlier produces an average SMT of -40+/-17C (n=7). Therefore, the average SMT expressed by the Mars science community over the past 44 years (two generations) is a sample temperature no greater than -40C. The difference in chemical reaction rates between this average SMT and Beaty et al [4] can be estimated using the Arrhenius equation. Assuming a generic chemical reaction with an activation energy of 50 kJ/mol and a pre-exponential factor invariant with temperature, this reaction will proceed 2300x faster at 60C than at -40C. To illustrate the effects of the increased reaction rate, consider 10 ppb of alanine in a Mars 2020 cache, and assume that it becomes unmeasurable if it degrades to 1 ppb, as per the Mars 2020 Organic Contamination Panel contamination limits [11]. If we illustrate the effect with an arbitrary degradation rate such that the alanine will become undetectable in ten years at -40C, then the same 10 ppb alanine degrades beyond detectability in only 38 days at 60C. Further research is required to quantify expected analyte losses in the cached samples due to thermal processing.

Fries, Marc↗

A Laser-Based Method for On-Site Analysis of UF6 at Enrichment Plants

The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DA samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.

LAARS↗

Will MSR Samples Cached on the Martian Surface Experience Significantly Greater Thermal Degradation than Samples Retained in the Rover?

Since the first Mars Sample Return (MSR)-related report published by the Jet Propulsion Laboratory (JPL) in 1974, a series of panels, reports, and white papers have recognized the importance of sample temperature in meeting mission goals and defined a sample maximum temperature (henceforth SMT) limit. The Mars Sample Handling and Requirements Panel (MSHARP, 1999) flatly stated that “[t]he main issue in sample preservation is temperature”. The Mars Exploration Program Analysis Group (MEPAG)’s “Science Priorities for Mars Sample Return” report (2008), declared that “[s]ignificant loss, particularly to biological studies, occurs if samples reach +50°C for three hours ” whereby “scientific objectives related to life goals could be seriously compromised”. Overall, a total of seven panels, white papers, and conference reports adopted a SMT of -40±17°C to preserve samples sufficiently to confidently achieve success in studies of past or present Martian life (see more detail in [5]). In contrast, the Mars 2020 rover (M2020) mission adopted a SMT of +60°C for samples stored on the Martian surface and +50°C for samples retained inside the rover, as stated in a conference poster presented by Beaty et al., 2016. M2020 is currently collecting samples for MSR in tubes. Half of those tubes will be retained within the M2020 rover body (hereafter rover samples, or RS) and half will be deposited on the Martian surface (cached samples or CS), with a currently undetermined number of each collected up to ten years later for return to Earth. CS samples can be expected to experience significantly higher temperatures than RS samples based on their exposed location in sunlight. This work will explore differences in deleterious chemical reaction rates due to thermal environment of both tube types. The findings here should be debated openly and considered when deciding which samples to return to Earth.

M Fries↗

Sample processing and analysis methods and apparatus

Sample handling, processing and analysis methods and apparatus are described. According to one aspect, a sample processing method includes providing a sample, providing a reference frame which comprises a plurality of markers arranged in a predefined pattern, wherein individual ones of the markers are uniquely identifiable from others of the markers, and associating the reference frame comprising the markers with the sample. The markers are amenable to human or machine reading and for computational manipulation in some examples.

36 MATERIALS SCIENCE↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Oxygen stable isotopes in the nuclear fuel cycle: Assessment of the potential for determining the fabrication and provenance history of anhydrous and hydrous uranium oxides

Determining the origin and history of interdicted nuclear materials is a central challenge in nuclear forensics. The oxygen stable isotope composition of uranium oxide compounds has emerged as a promising forensic signature, attracting increasing attention since the early 2000s. This review examines analytical techniques for measuring oxygen isotope compositions in uranium oxides and evaluates how the nuclear fuel production cycle introduces or modifies these isotopic signatures. The potential for forensic geolocation is explored through workflows that calibrate the relationship between environmental water oxygen isotopes and those found in uranium oxides. Key strengths and limitations of this approach are assessed, including gaps in knowledge related to isotope fractionation during specific stages of the fuel cycle, and processing facility water inputs. The importance of proper sample handling and storage under inert atmospheres, as well as a deeper understanding of both intra-sample oxygen isotope heterogeneity, and hydrous uranium oxide phase formation, is highlighted for improving the reliability of forensic interpretations. In conclusion, the development of uranium oxide standards with well-characterized δ 18 O values and international collaboration toward consensus on their use are identified as essential steps for advancing the field.

Attribution↗

SNS Sample Activation Calculator Flux Recommendations and Validation

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples. The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.

43 PARTICLE ACCELERATORS↗

SNS Sample Activation Calculator Experimental Validation - Paper 79

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of all samples after they have been exposed to the neutron beam in any of the neutron scattering instruments at the SNS beamlines. The SAC web page takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and then calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and beamline scientists and users have noticed discrepancies in the predicted activation of their samples. As a part of the Neutronics Analysis Group at SNS, we were tasked with validating the SAC tool and diagnosing the origin of the discrepancies seen by the beamline scientists and the users. In the process of performing these measurements, we additionally found that several aspects of realistic neutron scattering operations, and thus sample exposure, cannot be captured with current configuration of the SAC tool. Typical neutron scattering samples are irradiated for multiple periods with different neutron energy ranges; the realities of accelerator operation indicate that not all of those periods will be at the same accelerator power, and scattering samples are frequently not fully illuminated by the well-collimated neutron beam. Finally, we will explore whether neutron beams, as modified by neutron guide systems with energy-dependent intensity modifications and by precise energy-band defining mechanical choppers, are suitably analyzed with multigroup cross section libraries in which there are typically very few energy groups below one eV. (authors)

43 PARTICLE ACCELERATORS↗

Probabilistic Round Trip Contamination Analysis of a Mars Sample Acquisition and Handling Process Using Markovian Decompositions

A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.

Hudson, Nicolas↗

Curation of Frozen Samples

NASA's Johnson Space Center (JSC) and the Astromaterials Curator are charged by NPD 7100.10D with the curation of all of NASA s extraterrestrial samples, including those from future missions. This responsibility includes the development of new sample handling and preparation techniques; therefore, the Astromaterials Curator must begin developing procedures to preserve, prepare and ship samples at sub-freezing temperatures in order to enable future sample return missions. Such missions might include the return of future frozen samples from permanently-shadowed lunar craters, the nuclei of comets, the surface of Mars, etc. We are demonstrating the ability to curate samples under cold conditions by designing, installing and testing a cold curation glovebox. This glovebox will allow us to store, document, manipulate and subdivide frozen samples while quantifying and minimizing contamination throughout the curation process.

Fletcher, L. A.↗