Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Tool Measuring Remaining Thickness of Notched Acoustic Cavities in Primary Reaction Control Thruster NDI Standards

Stress corrosion cracking in the relief radius area of a space shuttle primary reaction control thruster is an issue of concern. The current approach for monitoring of potential crack growth is nondestructive inspection (NDI) of remaining thickness (RT) to the acoustic cavities using an eddy current or remote field eddy current probe. EDM manufacturers have difficulty in providing accurate RT calibration standards. Significant error in the RT values of NDI calibration standards could lead to a mistaken judgment of cracking condition of a thruster under inspection. A tool based on eddy current principle has been developed to measure the RT at each acoustic cavity of a calibration standard in order to validate that the standard meets the sample design criteria.

Sun, Yushi↗

Pharmacodynamics of Promethazine in Human Subjects

Promethazine (PMZ) is the drug of choice for the treatment of symptoms associated with space motion sickness in astronauts. Side effects of PMZ include sedation, dizziness and cognitive performance impairment. In this study, we examined pharmacodynamics (PD) in human subjects and validated methods for evaluating cognitive performance effects of medications in space. METHODS: PMZ (12.5,25, and 50 mg) or placebo was administered by IM injection to human subjects in a randomized double-blind treatment design. Samples and data were collected for 72 h post dose. PD evaluation was performed using a battery of performance tests administered using WinSCAT (Windows based Space Cognitive Assessment Test) on a laptop computer, and ARES (ANAM Readiness Evaluation System) on a PDA, plasma concentrations of PMZ were measured using a LC-MS method. RESULTS: Results indicate a linear correlation between PMZ concentration and cognitive performance parameters (p<0.01). Test accuracy decreased and test completion time and response time increased significantly with increasing plasma PMZ concentration. CONCLUSIONS: These results suggest a concentration dependent decrement in cognitive performance associated with PMZ. WinSCAT and ARES are sensitive tools for the assessment PMZ PD and may be applicable for such evaluations with other neurocognitive drugs.

Gatlin, K. T.↗

Model Effects on GLAS-Based Regional Estimates of Forest Biomass and Carbon

ICESat/GLAS waveform data are used to estimate biomass and carbon on a 1.27 million sq km study area. the Province of Quebec, Canada, below treeline. The same input data sets and sampling design are used in conjunction with four different predictive models to estimate total aboveground dry forest biomass and forest carbon. The four models include nonstratified and stratified versions of a multiple linear model where either biomass or (square root of) biomass serves as the dependent variable. The use of different models in Quebec introduces differences in Provincial biomass estimates of up to 0.35 Gt (range 4.942+/-0.28 Gt to 5.29+/-0.36 Gt). The results suggest that if different predictive models are used to estimate regional carbon stocks in different epochs, e.g., y2005, y2015, one might mistakenly infer an apparent aboveground carbon "change" of, in this case, 0.18 Gt, or approximately 7% of the aboveground carbon in Quebec, due solely to the use of different predictive models. These findings argue for model consistency in future, LiDAR-based carbon monitoring programs. Regional biomass estimates from the four GLAS models are compared to ground estimates derived from an extensive network of 16,814 ground plots located in southern Quebec. Stratified models proved to be more accurate and precise than either of the two nonstratified models tested.

Nelson, Ross↗

Dynamic Method for Identifying Collected Sample Mass

G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

Carson, John↗

Model Effects on GLAS-Based Regional Estimates of Forest Biomass and Carbon

Ice, Cloud, and land Elevation Satellite (ICESat) / Geosciences Laser Altimeter System (GLAS) waveform data are used to estimate biomass and carbon on a 1.27 X 10(exp 6) square km study area in the Province of Quebec, Canada, below the tree line. The same input datasets and sampling design are used in conjunction with four different predictive models to estimate total aboveground dry forest biomass and forest carbon. The four models include non-stratified and stratified versions of a multiple linear model where either biomass or (biomass)(exp 0.5) serves as the dependent variable. The use of different models in Quebec introduces differences in Provincial dry biomass estimates of up to 0.35 G, with a range of 4.94 +/- 0.28 Gt to 5.29 +/-0.36 Gt. The differences among model estimates are statistically non-significant, however, and the results demonstrate the degree to which carbon estimates vary strictly as a function of the model used to estimate regional biomass. Results also indicate that GLAS measurements become problematic with respect to height and biomass retrievals in the boreal forest when biomass values fall below 20 t/ha and when GLAS 75th percentile heights fall below 7 m.

Nelson, Ross F.↗

Boeing: Arc Jet Exposure of Ablative Non-Oxide CMC TPS for Planetary Probe and Sample Return Applications

NASA Game Changing Development (GCD) provided Boeing support under a Space Act Agreement (SAA) for arc jet sample design, CFD support and arc jet test time of stagnation and shear models for 3 Boeing TPS materials: BLA (Boeing Lightweight Ablator, 18, 21 and 22 densities), BPA (Boeing Phenolic Ablator, standard, graded density, or without reinforcement) and Non-oxide high temperature ceramic composite for structurally integrated TPS (SITPS). Results: For BLA, tested successfully to 500 W/cm² heat flux and heat loads up to 12 kJ/cm² with shear loads up to 370 Pa. The BPA 2017 formulation tested successfully to 1500 W/cm² and 80 kJ/cm², with shear loads up to 250 Pa. For SITIPS, Boeing fabricated C/SiC laminate materials survived testing in shear.

commercial space↗

Refining Lucy Mission Delta-V During Spacecraft Design Using Trajectory Optimization Within High-Fidelity Monte Carlo Maneuver Analysis

Recent advances linking medium-fidelity trajectory optimization and high-fidelity trajectory propagation/maneuver design software with Monte Carlo maneuver analysis and parallel processing enabled realistic statistical delta-V estimation well before launch. Completing this high-confidence, refined statistical maneuver analysis early enabled release of excess delta-V margin for increased dry mass margin for the Lucy Jupiter Trojan flyby mission. By 3.3 years before launch, 16 of 34 TCMs had 1000 re-optimized trajectory design samples, yielding tens of m/s lower 99%-probability delta-V versus targeting maneuvers to one optimal trajectory. One year later, 1000 re-optimized samples of all deterministic maneuvers and subsequent flybys further lowered estimated delta-V.

Trojan↗

Half of global methane emissions come from highly variable aquatic ecosystem sources

Atmospheric methane is a potent greenhouse gas that plays a major role in controlling the Earth’s climate. The causes of the renewed increase of methane concentration since 2007 are uncertain given the multiple sources and complex biogeochemistry. Here, we present a metadata analysis of methane fluxes from all major natural, impacted and human-made aquatic ecosystems. Our revised bottom-up global aquatic methane emissions combine diffusive, ebullitive and/or plant-mediated fluxes from 15 aquatic ecosystems. We emphasize the high variability of methane fluxes within and between aquatic ecosystems and a positively skewed distribution of empirical data, making global estimates sensitive to statistical assumptions and sampling design. We find aquatic ecosystems contribute (median) 41% or (mean) 53% of total global methane emissions from anthropogenic and natural sources. We show that methane emissions increase from natural to impacted aquatic ecosystems and from coastal to freshwater ecosystems. We argue that aquatic emissions will probably increase due to urbanization, eutrophication and positive climate feedbacks and suggest changes in land-use management as potential mitigation strategies to reduce aquatic methane emissions.

aquatic ecosystem↗

Envisioning the Future of International Earth Observations Collaboration: Area and Map Accuracy Estimation by Sampling

- Maps have errors, sometimes a lot of errors ⇒ obtaining information directly from map problematic; any use of the map will benefit from information about errors/uncertainty - IPCC: unbiasedness and uncertainty - By randomly drawing a sample from the study area, observing reference conditions at drawn locations, and constructing estimators – easily estimate areas and map accuracy ± uncertainty - Sampling design and analysis, relatively easy – collecting reference observations is not. Cloud-based solutions, e.g. AREA2, Collect Earth Online, facilitate the collection of reference observations - More research and guidance needed!

Pontus Olofsson↗

Determination of Chlorophyll Content in Selected Grass Communities of Krkonoše Mts. Tundra Based on Laboratory Spectroscopy and Aerial Hyperspectral Data

The study focuses on the determination of chlorophyll content in four prevailing grasses in the relict arctic-alpine tundra located in the Krkonoše Mountains National Park, Czech Republic. We compared two methods for determination of leaf chlorophyll content (LCC) – spectrophotometric determination in the laboratory, and the LCC assessed by fluorescence portable chlorophyll meter CCM-300. Relationships were established between the LCCs and vegetation indices calculated from leaf spectra acquired with contact probe coupled with an ASD FieldSpec4 Wide-Res spectroradiometer. Canopy chlorophyll contents (CCC) were computed from the LCCs and green leaf area index (LAI), and modelled based on the field spectra measured by the spectroradiometer and the hyperspectral images acquired by Headwall Nano-Hyperspec® mounted on the DJI Matrice 600 Pro drone. The calculations are performed on datasets acquired in June, July and August 2020 together and separately for species and months. In general, the correlations based on June datasets work the best at both levels: median R 2 for all indices was 0.52 for all species together at leaf level and median R 2 = 0.47 at the canopy level (vegetation indices computed from field spectra). Canopy chlorophyll content map was created based on the results of stepwise multiple linear regression. The R 2 was 0.42 when using four wavelengths from the red and red edge spectral region. We attribute the weak model performance to a combination of several factors: leaf structure may bias LCC from laboratory measurements, effects of LAI variability on CCC, and the sampling design, probably not covering the whole phenology equally for all studied species.

L. Cervena↗

Mars Rover Sample Return Orbiter design concepts

The observational orbiter of the Mars Rover Sample Return mission will observe the (10x10 km) landing sites and provide data that will be used in the decision to commit the landing vehicles to a landing at a chosen site. To provide observational data from orbit at a surface resolution consistent with the hazard tolerance of the landing vehicles, the orbiter imaging subsystem must be capable of 0.25 meters resolution per picture element (pixel). The design of the imaging, pointing, and data subsystems capable of providing this capability has been completed in this study. The rationale for these requirements and the more detailed derived requirements affecting the spacecraft design are discussed.

Randolph, J. E.↗

Design of a sample acquistion system for the Mars exobiological penetrator

The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

Thomson, Ron↗

The Antaeus Project - An orbital quarantine facility for analysis of planetary return samples

A design is presented for an earth-orbiting facility for the analysis of planetary return samples under conditions of maximum protection against contamination but minimal damage to the sample. The design is keyed to a Mars sample return mission profile, returning 1 kg of documented subsamples, to be analyzed in low earth orbit by a small crew aided by automated procedures, tissue culture and microassay. The facility itself would consist of Spacelab shells, formed into five modules of different sizes with purposes of power supply, habitation, supplies and waste storage, the linking of the facility, and both quarantine and investigation of the samples. Three barriers are envisioned to protect the biosphere from any putative extraterrestrial organisms: sealed biological containment cabinets within the Laboratory Module, the Laboratory Module itself, and the conditions of space surrounding the facility.

Sweet, H. C.↗

OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

OSIRIS-REX TOUCH-AND-GO (TAG) MISSION DESIGN FOR A↗

Synchronized Lunar Pole Impact Plume Sample Return Trajectory Design

The presented trajectory design enables two maneuverable spacecraft launched onto the same trans-lunar injection trajectory to coordinate a steep impact of a lunar pole and subsequent sample return of the ejecta plume to Earth. To demonstrate this concept, the impactor is assumed to use the LCROSS missions trajectory and spacecraft architecture, thus the permanently-shadowed Cabeus crater on the lunar south pole is assumed as the impact site. The sample-return spacecraft is assumed to be a CubeSat that requires a complimentary trajectory design that avoids lunar impact after passing through the ejecta plume to enable sample-return to Earth via atmospheric entry.

impact plume↗