Retrofitting stoves with forced jets of primary air improves speed, emissions, and efficiency: Evidence from six types of biomass cookstoves

Incorporating jets of forced air into biomass cookstove combustion has been shown to potentially decrease harmful emissions, leading to a variety of designs in recent years. These have shown mixed success in terms of real-world performance, usability, and durability. The Jet-Flame forced draft retrofit accessory was recently developed to implement forced jets of primary air at a low cost into a wide range of types of cookstoves using a small 1.5-W fan housed in a low-cost cast iron body to be inserted beneath the fuel bed of a biomass cooking fire. This research sought to quantify the potential efficiency and emissions performance impacts of the Jet-Flame when installed in six different types of biomass cookstoves (three open or shielded fires and three rocket stoves) versus the natural draft performance of each. The effect of the operating fan voltage was also measured. A series of tests following a modified ISO 19867-1:2018 protocol were performed in the laboratory using the Aprovecho Laboratory Emissions Measurement System (LEMS) equipped with additional oxygen and temperature sensors. Results for each stove carefully tended with a single layer of sticks showed that the global average PM 2.5 reduction with the Jet-Flame was 89 % relative to the natural draft cases, with larger relative improvements seen in the most rudimentary stoves. CO was reduced by a global average of 74 %, reaching tier 4 or 5 for all stoves. Thermal efficiency was also improved by 34 % when calculated without taking into account the energy content of the remaining char (or 21 % with char), illustrating the value of burning char to provide cooking energy rather than leaving it unburned in the combustion chamber as is common in many natural draft stoves. Time to boil was also reduced by 8 %. In addition, adjusting the voltage of the jet-flame assisted in modulating firepower, improving the usability of the stove. These results indicate a strong potential for the Jet-Flame to help reduce emissions and fuel consumption in a wide range of cookstove designs at a relatively low cost or need for changes in behavior, fuel, or cooking device. The unit also provides enhanced usability in terms of ease of startup, cooking speed, low PM emissions at high power, and burning char. Additional studies are needed to measure performance in the field and under a variety of operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insights from FEED studies for retrofitting existing fossil power plants with carbon capture technology

Recent United States Department of Energy (DOE) sponsored front-end engineering design (FEED) studies for retrofitting existing fossil-fueled power plants with state-of-the-art carbon capture technology contain previously overlooked real-world design considerations for near-term deployment of carbon capture. Insights from examining seven recently published FEED study reports are summarized in this paper. This includes a discussion of the design, performance, and cost implications associated with (1) location-specific considerations such as water availability, land availability, and accessibility; (2) host-plant-specific factors such as flue gas specifications, allowable degree of integration between the capture system and host plant, and operational mode; and (3) miscellaneous factors such as market conditions, permitting requirements, and business case incentives. In conclusion, this manuscript highlights (1) water availability as a key design and cost driver, with host plant steam extraction increasing capture system cooling water availability, (2) modularization and constructability impacts on the number of capture trains, (3) the impacts of host plant operational mode and capacity factor on the business case for installing capture, and (4) the merit of continued research, development, and demonstration efforts addressing steam extraction, host plant tie-in at the stack, solvent reclamation and air emissions control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal power plant upgrade via a rotating detonation combustor and retrofitted turbine with optimized endwalls

Over the past decade, pressure gain combustion research has promised over 10 percentage-points of increase in power plant thermal efficiency. Alas, to realize such potential gain, one must effectively couple the turbine with the detonation combustor, whose exhaust conditions differ substantially from current state of the art gas turbines. This paper presents a modeling approach that enables a superior thermodynamic cycle with a rotating detonation combustor and a retrofitted gas turbine by including a diffuser downstream of the combustor and by contouring the turbine endwall, while preserving the airfoil geometry. We propose a multi-step optimization strategy, parametrizing the endwall geometry with a few control points, without altering the airfoil geometry, and with the stage turbine efficiency as objective function. In a first step the turbine performance is assessed with steady inlet conditions by solving the steady three-dimensional Reynolds-Averaged Navier-Stokes equations. In a second step, the inlet conditions are unsteady, as predicted from a detonation combustor and a diffuser, and three-dimensional full unsteady simulations are performed with an unsteady Reynolds-Averaged Navier-Stokes solver. By altering the vane endwall, the steady optimization yielded an efficiency increase of 12% relative to the baseline, while the unsteady optimization resulted in 21% increase compared to the datum turbine. Finally, a full engine analysis demonstrated the superiority of pressure gain combustion which included a realistic thermodynamic cycle of the combustor, the diffuser and the optimized turbine components.

42 ENGINEERING↗

Building Efficiency Targeting Tool for Energy Retrofits (BETTER) Web Application (BETTER Web App) v1.0

The Building Efficiency Targeting Tool for Energy Retrofits (BETTER) V.1.0 web application identifies cost-saving energy and emissions reductions in buildings and portfolios, without site visits or complex modeling. With minimal data entry, BETTER benchmarks a building's or portfolio's energy use against peers; quantifies energy, cost, and greenhouse gas (GHG) reduction potential; and recommends energy efficiency measures for individual buildings or portfolios, targeting specific energy savings levels. The source code of BETTER's modular, cross-platform analytical engine has previously been disclosed (2019-001) and is available on GitHub and can be adopted, redeveloped, and redistributed freely under an open-source license, allowing users to incorporate BETTER's analytical capabilities into their own software platforms and tools. The BETTER V.1.0 web application, developed with the Django web-framework and the Model-View-Controller (MVC) architecture being disclosed here, provides a graphical user interface (GUI) for any user to view the software tutorials, download and upload a data entry template, configure and run the BETTER analyses, and view the final analytical reports.

Szum, Carolyn↗

Mapping ammonia-diesel combustion on a single-cylinder 107 mm bore diesel engine retrofitted for ammonia port-fuel injection

Ammonia is garnering significant interest from the international maritime sector as an alternative fuel. It is attractive as a hydrogen carrier and as a fuel because it has a higher volumetric energy density compared with gaseous or liquid hydrogen, making it easier to store and transport without requiring high pressures or cryogenic storage. Ammonia has significant toxicity concerns, but safe handling procedures have already been established because it is one of the most widely produced chemicals worldwide for use as a fertilizer. Barriers to consuming NH 3 as a fuel in engines include (1) less favorable ignition energy and flame speed compared with conventional fuels; (2) emissions challenges, including potentially high NH 3 , NO X , and N 2 O emissions; and (3) fuel delivery and handling challenges. Although NH 3 has been used to fuel compression-ignition marine engines in limited demonstration projects, technical barriers still exist. The use of NH 3 as a fuel in smaller-bore, high-speed auxiliary engines for large vessels and for smaller inland and coastal marine applications remains unaddressed. This work investigates a late-injection diesel pilot ignition dual-fuel NH 3 strategy using a single-cylinder, high-speed Cummins four-stroke diesel engine platform with a 107 mm bore and 1.1 L displacement per cylinder. The engine was modified for port fuel injection of heated gaseous anhydrous NH 3 . The diesel fuel injection system and the combustion geometry were unmodified to represent a retrofit application, which would minimize additional hardware to maximize diesel fuel displacement with NH 3 . Furthermore, the results show the applicability of a late injection diesel pilot strategy to overcome the challenging fuel properties of NH 3 over the engine operating envelope. Mapping results focusing on emissions are presented, and comparisons are made to a conventional diesel combustion baseline.

Ship engines↗

Project Report: School Retrofit Demonstration of Lighting and Outlet Controls with LED Upgrades

A technology demonstration project funded by the U.S. Department of Energy (DOE) was hosted by Boston Public Schools (BPS). This project evaluated wireless controls technology for lighting systems and plug loads (energy consumed by devices plugged into electrical outlets), implemented along with LED lighting retrofits in two classrooms. This study assesses technology readiness and effectiveness to determine the deployment potential of the technology in schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Central Plant Retrofit Assessment Guide for Owners

This document offers support to owners considering optimization upgrades, retrofits, or complete replacement of a central plant, with a particular focus on improving energy efficiency and reliability of the central plant, ultimately leading to reduced energy costs. It outlines recommended steps to prepare for and facilitate a thorough central plant assessment, empowering owners to move forward with the appropriate next steps. While the primary focus is on central plants serving commercial and institutional buildings, the principles and recommendations presented can also be adapted for use in other building types, such as industrial or manufacturing facilities.

42 ENGINEERING↗

Scaling Energy Efficient Retrofits for Small Commercial Apartment Buildings

With support from the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO), the International Center for Appropriate and Sustainable Technology (ICAST) recently completed a three-year cooperative agreement to scale energy efficiency retrofits (EER) on small multifamily (MF) buildings. ICAST EER strategies ranged from low-hanging “direct install” of measures such as LED lighting, low-flow showerheads and aerators, and smart thermostats to major strategies such as HVAC replacement with high-efficiency boilers or heat pumps. As feasible, some projects also included the addition of renewable energy sources such as photo voltaic (PV) solar. When ICAST began the BTO project, it operated in two states and oversaw EER at approximately 80 MF buildings per year. With assistance from BTO, ICAST has grown significantly and now has staff in six states with MF EER projects in another seven, and performed EER on 956 MF buildings. ). ICAST was able to successfully execute this project by 1) Improving viability and efficiency of its processes, 2) Launching two new services and 3) Creating an affiliate program. For the most part, ICAST focused on a specific type of MF property: naturally occurring affordable housing (NOAH), because it is a significantly underserved market within the hard-to-serve MF market. NOAHs are typically smaller properties (5 to 64 units), owned by small organizations or individual investors looking for positive cash flow. ICAST believes the NOAH market can be successfully served with a one-stop-shop approach that makes it easy, hassle-free, and cost-effective for owners to acquire green upgrades for their property(ies). With the assistance of BTO funding, ICAST successfully used the cited EER methods and strategies to scale-up its OSS approach to service a greater number of MF housing and expand into new geographies. Additionally, support from BTO helped ICAST create self-sustaining programs which will not need to rely on on-going funding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Retrofit Wall Performance Predicted from Hygrothermal Simulations to Measurements

Over the past few years ORNL has been showing that WUFI® can be used to predict the moisture performance of walls when exposed to diffusion of water vapor, convection of moist air through the wall, and solar driven moisture. This is accomplished by comparing the hygrothermal simulation results to carefully instruments walls exposed to these phenomena in a climate chamber. In FY 2018, three stick-built walls were succumbed to typical Chicago, Illinois weather conditions in Oak Ridge National Laboratory’s Heat, Air and Moisture chamber. The measured temperature, relative humidity, and moisture content within these walls were compared with WUFI hygrothermal simulation results. In FY 2019, similar experiments and comparisons with WUFI results were completed with two walls, a structural insulated panel-based wall and a concrete masonry unit-based wall. In FY 2020, experiments were completed for a probable exterior retrofit of a wall which included adding cavity and continuous insulation. Two pairs of walls were tested by exposing them to Chicago winter weather with a positive pressure pushing outside air into the wall. The results from the FY 2020 experiments are reported here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Front-End Engineering Design Study for Retrofit Post-Combustion Carbon Capture on a Natural Gas Combined Cycle Power Plant

The objective of the project is to conduct a Front-End Engineering Design (FEED) study to determine the technical and economic feasibility of installing a retrofit, post-combustion, carbon capture facility on a commercially operating, natural gas-fired, combined cycle (NGCC) power plant. The Electric Power Research Institute (EPRI), California Resources Corporation (CRC), and Fluor Corporation used Fluor's Econamine FG Plus SM (EFG+) conducted the FEED study for capturing CO 2 produced by CRC's 550 MWe Elk Hills Power Plant (EHPP), located in the Elk Hills Oil Field near Tupman, Kern County, California. The EHPP was commissioned in 2003 and is powered by two General Electric 7FA gas turbines, with two heat recovery steam generators (HRSGs) providing steam to a General Electric D11 steam turbine. The target capture amount is 4,000 tonnes CO 2 /day for use in either enhanced oil recovery or dedicated geological saline storage located on CRC property at or nearby EHPP. This CO 2 is captured from a combination of the CO 2 emitted from the flue gas from EHPP and the flue gas generated from a natural gas-fired auxiliary boiler that supplies steam to the EFG+ process.

03 NATURAL GAS↗

Aleut Community Store Refrigeration Efficiency Retrofit with Heat Recovery (Final Report)

The Project Goal is to improve the energy efficiency of the Aleut Community Store by installing deep energy retrofits. Project Objectives are: 1) Replace refrigeration equipment and display cases with an energy efficient refrigeration system and energy efficient refrigeration display cases; utilize waste heat to heat the building; and 2) Lower cost of energy and maintenance for Aleut Community Store by $44,385 (energy and maintenance)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GE 1.5 ESS Wind Turbine Retrofit Controller Development (CRADA Final Report)

National Renewable Energy Laboratory (NREL) and Bachmann electronic corp. will collaborate on the development of a software application to be used on an existing aftermarket Bachmann controller, utilizing and existing Bachmann software platform, which will be used on the General Electric (GE) 1.5 ESS wind turbine. This retrofit will significantly enhance NREL’s ability to control experiments it is planning to conduct on the GE 1.5 wind turbine as part of the Gearbox Reliability Collaborative, Atmosphere to Electrons and other future R&D. The proposed work is leveraging ongoing Department of Energy (DOE) Annual Operating Plan activities on the GE 1.5 ESS wind turbine at the National Wind Technology Center.

17 WIND ENERGY↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Countrywide LED Lighting Retrofit for Safety, Visibility, and Energy Efficiency (Final Technical Report)

The project supported national clean energy goals by reducing electricity demand and improving energy efficiency in public infrastructure. Tasks defined in the Statement of Project Objectives included site assessments, retrofit planning, lighting design optimization, installation, monitoring, and reporting. All milestones and go/no-go decision points were successfully met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic Estimation of CO2 Emission Reductions Due to Building Retrofit

Constant CO2 emission factors of electricity are often used to study the emissions of buildings. However, in the era of increased renewable energy for power generation, emission factors of electricity are dynamically changing. This study is to investigate the impact of dynamic CO2 emission factors, which are more realistic than constant ones, on the emission reductions due to building retrofits. The results reveal that if dynamic CO2 emission factors are used for U.S. medium office buildings, improving the efficiency of lighting or electric equipment will lead to more emission reductions in locations with high wind power penetration (e.g., 12% more reductions in Rochester) and fewer reductions in locations with high solar power penetration (e.g., 8% fewer reductions in San Diego). As for improving envelope insulation, dynamic CO2 emission factors have more impact on the emission reductions in hot climates than in cold climates.

Lou, Yingli↗

Apparatus and process of retrofitting a combined cycle power plant

A process for retrofitting an electric power plant that uses two 60 Hertz large frame heavy duty industrial gas turbine engines to drive electric generators and produce electricity, where each of the two industrial engines can produce up to 350 MW of output power. The process replaces the two 350 MW industrial engines with one twin spool industrial gas turbine engine that is capable of producing at least 700 MW of output power. Thus, two prior art industrial engines can be replaced with one industrial engine that can produce power equal to the two prior art industrial engines.

20 FOSSIL-FUELED POWER PLANTS↗