Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

Operational Analysis of the Eastern Interconnection at Very High Renewable Penetrations

The primary objective of the study reported here is to build on work by Mai et al. (2012) and Brinkman (2015) by performing detailed modeling of the U.S. Eastern Interconnection operations with approximately 70% of all energy coming from wind and solar generation. The study assesses the ability to balance supply and demand for electricity using a unit commitment and economic dispatch model with a five-minute time resolution. In addition, the study explores the implications of different amounts of physical and institutional flexibility for balancing. We also present an analysis of system “stress” by quantifying various metrics, such as the amount of spare online capacity, penetration levels of non-synchronous generators, day-ahead compared to real-time curtailment, and start-ups of peaking generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced Long-Duration Energy Storage Modeling [Slides]

As our power grid evolves toward a more renewable future, energy storage is poised to take a larger role in meeting growing energy needs. Energy storage could help keep the power system reliable even through potential outages, periods of extreme weather, and when generation from variable renewable technologies like wind and solar is low. Given the different durations of these stressors, grid analysts at the National Renewable Energy Laboratory (NREL) are working to better understand the role and benefits of long-duration energy storage - or storage technologies with 8-24 hours of storage capacity - in high variable renewable energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evolving Metrics for Resource Adequacy Assessment

Resource adequacy analysis quantifies the likelihood of capacity shortfall on a power system in a probabilistic manner. Using a combination of statistical techniques and power system fundamentals, the analysis typically evaluates hundreds or thousands of stochastic random samples (replications) of varying load, generator outages, variable renewable energy availability, and other aspects of power system uncertainty. In this range of uncertainty, there are - at times - periods where the power system's available resources are insufficient to meet system demand, referred to as a shortfall event. Today's power systems' rapidly evolving generation mix is changing the types of data needed by system planners and regulators, which can often render traditional resource adequacy metrics insufficient for ensuring resource adequacy for tomorrow's grid. In this paper we provide a critical assessment of traditional measures of shortfall risk in power systems, discussing their shortcomings and how they compare to metrics used in other domains. From this analysis we propose four steps forward for improving power system resource adequacy risk metrics in the future.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Beyond Expected Values Evolving Metrics for Resource Adequacy Assessment

Resource adequacy analysis quantifies the likelihood of capacity shortfall on a power system in a probabilistic manner. Using a combination of statistical techniques and power system fundamentals, the analysis typically evaluates hundreds or thousands of stochastic random samples (replications) of varying load, generator outages, variable renewable energy availability, and other aspects of power system uncertainty. In this range of uncertainty, there are - at times - periods where the power system's available resources are insufficient to meet system demand, referred to as a shortfall event. Today's power systems' rapidly evolving generation mix is changing the types of data needed by system planners and regulators, which can often render traditional resource adequacy metrics insufficient for ensuring resource adequacy for tomorrow's grid. In this paper we provide a critical assessment of traditional measures of shortfall risk in power systems, discussing their shortcomings and how they compare to metrics used in other domains. From this analysis we propose four steps forward for improving power system resource adequacy risk metrics in the future.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Wind and Solar on the Value of Energy Storage

This analysis evaluates how the value of energy storage changes when adding variable generation (VG) renewable energy resources to the grid. A series of VG energy penetration scenarios from 16% to 55% were generated for a utility system in the western United States. This operational value of storage (measured by its ability to reduce system production costs) was estimated in each VG scenario, considering provision of different services and with several sensitivities to fuel price and generation mix. Overall, the results found that the presence of VG increases the value of energy storage by lowering off-peak energy prices more than on-peak prices, leading to a greater opportunity to arbitrage this price difference. However, significant charging from renewables, and consequently a net reduction in carbon emissions, did not occur until VG penetration was in the range of 40%-50%. Increased penetration of VG also increases the potential value of storage when providing reserves, mainly by increasing the amount of reserves required by the system. Despite this increase in value, storage may face challenges in capturing the full benefits it provides. Due to suppression of on-/off-peak price differentials, reserve prices, and incomplete capture of certain system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit (reduction in production costs) provided to the system. Furthermore, it is unclear how storage will actually incentivize large-scale deployment of renewables needed to substantially increase VG penetration. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.

14 SOLAR ENERGY↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees

With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling, control, and dynamic performance analysis of a reverse osmosis desalination plant integrated within hybrid energy systems

An RO (reverse osmosis) desalination plant is proposed as an effective, FLR (flexible load resource) to be integrated into HES (hybrid energy systems) to support various types of ancillary services to the electric grid, under variable operating conditions. To study the dynamic (transient) analysis of such system, among the various unit operations within HES, special attention is given here to the detailed dynamic modeling and control design of RO desalination process with a spiral-wound membrane module. The model incorporates key physical phenomena that have been investigated individually into a dynamic integrated model framework. In particular, the solution-diffusion model modified with the concentration polarization theory is applied to predict RO performance over a large range of operating conditions. Simulation results involving several case studies suggest that an RO desalination plant, acting as a FLR, can provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess electrical energy. Here, the incorporation of additional commodity (fresh water) produced from a FLR allows a broader range of HES operations for maximizing overall system performance and profitability. For the purpose of assessing the incorporation of health assessment into process operations, an online condition monitoring approach for RO membrane fouling supervision is addressed in the case study presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Balancing Act

Explore the source record for details and available documents.