Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Global satellite measurements of water vapour, wind speed and wave height

The results of global measurements of atmospheric water vapor by the Seasat Scanning Multichannel Microwave Radiometer and wave height and wind speed by the Seasat altimeter (ALT) are reported. The 13.5 GHz ALT has a 3.125 ns pulsewidth and 1022 Hz repetition rate, and measures surface height to a resolution exceeding 10 cm celative to a reference ellipsoid. Full ALT data comprise 135 km equatorial groundtracks, with about a 50 cm difference of sea wave height compared to buoy reference measurements, and windspeed accuracy to within 0.25-1.58 m/sec up to 20 m/sec. Highest water vapor concentrations were observed in the tropics and the lowest at high latitudes. Wind speeds were highest for the north-east and south-east tradewinds in both the Atlantic and Pacific oceans. Average wave height is small in the summer North Hemisphere and the largest waves are in the winter Southern ocean, and lowest in western Atlantic and Pacific ocean areas where winds are lightest.

Chelton, D. B.↗

In situ measurement of stratospheric nitric oxide using a balloon-borne tunable diode laser spectrometer

The stratospheric mixing ratio of nitric oxide at an altitude of 36 km has been measured using a balloon-borne tunable diode laser (TDL) instrument operating in the 5.2-micron wavelength region. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species simultaneously: NO, NO2, O3, and H2O. During the NO measurements reported here, the second TDL operating near 6.2 microns was used to monitor water vapor concentration in the vicinity of the gondola by observing the 1889.57 per cm line absorption in the reference channel path length (1 m).

Webster, C. R.↗

A simulation model for the analysis of Space Station gas-phase trace contaminants

A simulation model for the analysis of gas-phase trace contaminants in the cabin air of the NASA Space Station Reference Configuration was developed at the NASA Langley Research Center. The model predicts changes in trace contaminant concentrations from both physical and chemical sources and sinks as a function of time. Simulations were performed in which values for relative humidity, temperature, radiation intensity, pressure, and initial species concentrations were constrained to values for these parameters measured and modeled in the continental tropics at the earth's surface. Species concentrations simulated using the model compared favorably with concentrations in the continental tropics which demonstrated that the chemical mechanism in the trace contaminant model approximates changes in atmospheric species concentrations. The sensitivity of initial species concentrations to producing changes in additional species concentrations was also assessed. Results from the model indicated that chemical reactions will be important in determining the composition of cabin air in the Space Station. It is anticipated that the trace contaminant model will be useful in assessing the impact of experiments and commercial operations on the composition of the cabin air in the Space Station.

Brewer, Dana A.↗

The Pathway to a Safe and Effective Medication Formulary for Exploration Spaceflight

PURPOSE: Exploration space missions pose several challenges to providing a comprehensive medication formulary designed to accommodate the size and space limitations of the spacecraft; while addressing the individual medications needs and preferences of the Crew; the negative outcome of a degrading inventory over time, the inability to resupply before expiration dates; and the need to properly forecast the best possible medication candidates to treat conditions that will occur in the future. METHODS: The Pharmacotherapeutics Discipline has partnered with the Exploration Medical Capabilities (ExMC) Element to develop and propose a research pathway that is comprehensively focused on evidence-based models and theories, as well as on new diagnostic tools and treatments or preventive measures aimed at closure of the Med02 “Pharmacy” Gap; defined in the Human Research Program’s (HRP) risk-based research strategy. The Med02 Gap promotes the challenge to identify a strategy to ensure that medications used to treat medical conditions during exploration space missions are available, safe, and effective. It is abundantly clear that pharmaceutical intervention is an essential component of risk management planning for astronaut healthcare during exploration space. However, the quandary still remains of how to assemble a formulary that is comprehensive enough to prevent or treat anticipated medical events; and is also chemically stable, safe, and robust enough to have sufficient potency to last for the duration of an exploration space mission. In cases where that is not possible, addressing this Gap requires exploration of novel drug development techniques, dosage forms, and dosage delivery platforms that enhance chemical stability as well as therapeutic effectiveness. RESULTS: The proposed research pathway outlines the steps, processes, procedures, and a research portfolio aimed at identifying a capability that will provide a safe and effective pharmacy for any specific exploration Design Reference Mission (DRM). The proposed approach to building this research portfolio is to seek research projects that concentrate on four major focus areas; (1) Formulary selection, (2) Formulary potency and shelf life, (3) Formulary safety and toxicity, and (4) Novel technology and innovation such as portable real-time chemical analysis innovative drug therapies and dosage and delivery platforms. CONCLUSION: The research pathway has been completed and presented to the HRP. In spring 2017, it is scheduled to be reviewed by a panel of pharmaceutical and clinical experts that will evaluate the scientific merit and operational feasibility of the research pathway, as well as make suggestions for any warranted additions or improvements. Once finalized, the ExMC Element will proceed with the execution of this research pathway with the goal of gathering as much data, and learning as much as possible, to provide a safe and effective pharmaceutical formulary for use during exploration missions.

Daniels, V. R.↗

A bibliography on the search for extraterrestrial intelligence

This report presents a uniform compilation of works dealing with the search for extraterrestrial intelligence. Entries are by first author, with cross-reference by topic index and by periodical index. This bibliography updates earlier bibliographies on this general topic while concentrating on research related to listening for signals from extraterrestrial intelligence.

Mallove, E. F.↗

Isoelectric focusing of proteins and peptides

Egg-white solution was chosen as the reference solution in order to assess the effects of operational parameters (voltage, flow rate, ampholine pH range and concentration, and protein concentration) of the RIEF apparatus on protein resolution. Topics of discussion include: (1) comparison of RIEF apparatus to conventional IEF techniques (column and PAG) with respect to resolution and throughput; (2) peptide and protein separation (AHF, Thymosin - Fraction 5, vasoactive peptide, L-asparaginase and ACP); and (3) detection of peptides - dansyl derivatives of amino acids and peptides, post-focusing fluorescent labeling of amino acids, peptides and proteins, and ampholine extraction from focused gels.

Egen, N.↗

High temperature durable catalyst development

A program has been carried out to develop a catalytic reactor capable of operation in environments representative of those anticipated for advanced automotive gas turbine engines. A reactor consisting of a graded cell honeycomb support with a combination of noble metal and metal oxide catalyst coatings was built and successfully operated for 1000 hr. At an air preheat temperature of 740 K and a propane/air ratio of 0.028 by mass, the adiabatic flame temperature was held at about 1700 K. The graded cell monolithic reaction measured 5 cm in diameter by 10.2 cm in length and was operated at a reference velocity of 14.0 m/s at 1 atm. Measured NOx levels remained below 5 ppm, while unburned hydrocarbon concentrations registered near zero and carbon monoxide levels were nominally below 20 ppm.

Snow, G. C.↗

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as liquid pumping and internal compression. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

A. J Juhasz↗

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as 'liquid pumping and internal compression'. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

Juhasz, A. J.↗

Observations of condensation nuclei in the 1987 airborne Antarctic ozone experiment

The condensation nucleus counter (CNC) flown of the NASA ER-2 in the Airborne Antarctic Ozone Experiment provides a measurement of the number mixing ratio of particles which can be grown by exposure to supersaturated n-butyl alcohol vapor to diameters of a few microns. Such particles are referred to as condensation nuclei (CN). The ER-2 CNC was calibrated with aerosols of known size and concentration and was found to provide an accurate measure of the number concentration of particles larger than about 0.02 micron. Since the number distribution of stratospheric aerosols is usually dominated by particles less than a few tenths of micron in diameter, the upper cutoff of the ER-2 CNC has not been determined experimentally. However, theory suggests that the sampling and counting efficiency should remain near one for particles as large as 1 micron in diameter. Thus, the CN mixing ratio is usually a good measure of the mixing ratio of submicron particles.

Wilson, J. C.↗

Critical needs of fringe-order accuracies in two-color holographic interferometry

Requirements for the fringe order accuracy in two-color holographic interferometry are discussed with reference to crystal growth. A simple test cell (rectangular parallelepiped) containing a fluid is considered. The temperature and concentration variations are related to the fringe orders from the two interference patterns, and the uncertainties in the fringe orders are related to errors in the temperature and concentration determination. The formulation developed here is applied to the particular case of an aqueous solution of triglycerine sulfate as an example.

Vikram, C. S.↗

Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four standards, and to within +/- 5% for all six standards.

Novelli, P. C.↗

Precision orbit determination using TOPEX/Poseidon TDRSS observations

The TOPEX/Poseidon (T/P) Mission carries a variety of packages to support experimental, precision and operational orbit determination. Included are a GPS transponder, laser retro-reflectors, the French-developed Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) Doppler tracking system and a Tracking Data Relay Satellite System (TDRSS) transponder. Presently, TDRSS tracking is used for operational orbit support and is processed with force and measurement modeling consistent with this purpose. However, the low noise and extensive geographical coverage of the TDRSS/TOPEX data allows an assessment of TDRSS Precision Orbit Determination (POD) capabilities by comparison to the T/P precision orbit determination. The Geodynamics (GEODYN) Orbit Determination System is used to process laser and DORIS data to produce the precision orbits for the T/P Project. GEODYN has been modified recently to support the TDRSS observations. TDRSS data analysis can now benefit from the extensive force modeling and reference frame stability needed to meet the orbit determination (OD) goals of the T/P Mission. This analysis has concentrated on the strongest of the TDRSS measurement types, its two-way average range rate. Both the TDRSS and T/P orbits have been assessed in combination with the global satellite laser ranging (SLR) data and by themselves. These results indicate that significant improvement in the TDRSS ephemerides is obtained when the T/P orbit is well determined by SLR, and the TDRSS/TOPEX Doppler link is used to position TDRSS. Meter-level TDRSS positioning uncertainty is achieved using this approach. When the TDRSS orbit location is provided by this approach, the two-way range rate from a single TDRSS (i.e. West only) can provide T/P orbits with sub-meter radial accuracies and two meter RMS total position agreement with SLR defined orbits. These preliminary results indicate improved modeling of the TDRSS measurement through the elimination of heretofore neglected effects like the motion of the T/P TDRSS antenna and improved modeling of ionospheric and atmospheric refractive effects, and the inclusion of TDRSS East in the analysis are warranted. Through these improvements, TDRSS can make a significant contribution to geopotential recovery and precision OD.

Teles, Jerome↗

A semianalytic radiance model of ocean color

A semianalytical radiance model is developed which predicts the upwelled spectral radiance at the sea surface as a function of the phytoplankton pigment concentration for Morel Case 1 waters. The model is in good agreement with experimental measurements carried out in waters which were not included in the data base used to derive it. It suggests that the observed variability in the radiance is due to variations in the backscattering of plankton and the associated detrital material. The model is extended to include other material in the water, such as dissolved organic material, referred to as yellow substances, and detached coccoliths from coccolithophorids, e.g., Emiliana huxleyi. Potential applications include an improved biooptical algorithm for the retrieval of pigment concentrations from satellite imagery in the presence of interference from detached coccoliths and an improved atmospheric correction for satellite imagery. The model also serves to identify and to interpret deviations from Case 1 waters.

Gordon, Howard R.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Determinants of Market Structure and the Airline Industry

The general economic determinants of market structure are outlined with special reference to the airline industry. Included are the following facets: absolute size of firms; distributions of firms by size; concentration; entry barriers; product and service differentiation; diversification; degrees of competition; vertical integration; market boundaries; and economies of scale. Also examined are the static and dynamic properties of market structure in terms of mergers, government policies, and economic growth conditions.

Raduchel, W.↗

Moderate Resolution Imaging Spectrometer (MODIS) for the NASA Earth Observing System (EOS)

MODIS is intended to provide daily global surveys for the oceans, the atmosphere, and land. To achieve this capability, this instrument requires at least a 1700 km swath width and provides geometric-instantaneous-fields-of-view that are either 214 m, 428 m, or 856 m in size with reference to a 705 km satellite altitude. The range of products to be supported by MODIS includes ocean chlorophyll concentration, ocean primary productivity, dissolved organic matter in the oceans, global SST, total suspended solids, land cover type, land surface temperatures, vegetation indices, and volcanic and fire events. Details of the MODIS-N and MODIS-T instrument concepts are discussed.

Thompson, Leslie L.↗

Rotation Rate of Saturn's Magnetosphere using CAPS Plasma Measurements

We present the present status of an investigation of the rotation rate of Saturn's magnetosphere using a 3D velocity moment technique being developed at Goddard which is similar to the 2D version used by Sittler et al. for SOI and similar to that used by Thomsen et al.. This technique allows one to nearly cover the full energy range of the Cassini Plasma Spectrometer (CAPS) IMS from 1 V . E/Q < 50 kV. Since our technique maps the observations into a local inertial frame, it does work during roll maneuvers. We make comparisons with the bi-Maxwellian fitting technique developed by Wilson et al. and the similar velocity moment technique by Thomsen et al. . We concentrate our analysis when ion composition data is available, which is used to weight the non-compositional data, referred to as singles data, to separate H+, H2+ and water group ions (W+) from each other. The chosen periods have high enough telemetry rates (4 kbps or higher) so that coincidence ion data, similar to that used by Sittler et al. for SOI is available. The ion data set is especially valuable for measuring flow velocities for protons, which are more difficult to derive using singles data within the inner magnetosphere, where the signal is dominated by heavy ions (i.e., proton peak merges with W+ peak as low energy shoulder). Our technique uses a flux function, which is zero in the proper plasma flow frame, to estimate fluid parameter uncertainties. The comparisons investigate the experimental errors and potential for systematic errors in the analyses, including ours. The rolls provide the best data set when it comes to getting 4PI coverage of the plasma but are more susceptible to time aliasing effects. In the future we will then make comparisons with magnetic field observations, Saturn ionosphere conductivities as presently known and the field aligned currents necessary for the planet to enforce corotation of the rotating plasma.

Sittler, E.↗