Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “redox signaling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

118 records · Page 7

Shot noise sets the limit of quantification in electrochemical measurements

Detection of single molecules, particles, and rapid redox events is a challenge of electrochemical investigations and requires either an amplification strategy or significant averaging for the electrochemical current to exceed the noise level. We consider the minimum number of electrons required to reach the limit of quantification in these electrochemical measurements. A survey of the literature indicates that the state-of-the-art limit in current detection for different types of measurements (e.g. voltammetry, single-molecule redox cycling, ion channel recordings of single molecules, metal nanoparticle collision, and phase nucleation) is independent of the nature of the measurement and increases linearly with reciprocal response time, Δt -1 , over ~5 orders of magnitude (from ~10 to ~10 6 s -1 ). This paper demonstrates that the practical limit of quantification requires cumulative measurement of ~2100 electrons during Δt and is determined by statistics of counting electrons, that is, the shot noise in the current.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The mechanosensory calcium-selective ion channel: key component of a plasmalemmal control centre?

Mechanosensory calcium-selective ion channels probably serve to detect not only mechanical stress but also electrical, thermal, and diverse chemical stimuli. Because all stimuli result in a common output, most notably a shift in second messenger calcium concentration, the channels are presumed to serve as signal integrators. Further, insofar as second messenger calcium in turn gives rise to mechanical, electrical, and diverse chemical changes, the channels are postulated to initiate regulatory feedbacks. It is proposed that the channels and the feedback loops play a wide range of roles in regulating normal plant function, as well as in mediating disturbance of normal function by environmental stressors and various pathogens. In developing evidence for the physiological performance of the channel, a model for a cluster of regulatory plasmalemmal proteins and cytoskeletal elements grouped around a set of wall-to-membrane and transmembrane linkers has proved useful. An illustration of how the model might operate is presented. It is founded on the demonstration that several xenobiotics interfere both with normal channel behaviour and with gravitropic reception. Accordingly, the first part of the illustration deals with how the channels and the control system within which they putatively operate might initiate gravitropism. Assuming that gravitropism is an asymmetric expression of growth, the activities of the channels and the plasmalemmal control system are extrapolated to account for regulation of both rate and allometry of cell expansion. Finally, it is discussed how light, hormones, redox agents and herbicides could in principle affect growth via the putative plasmalemmal control cluster or centre.

NASA Program Space Biology↗

Oxidation States of Grim Glasses in EET79001 Based on Vanadium Valence

Gas-rich impact-melt (GRIM) glasses in SNC meteorites are very rich in Martian atmospheric noble gases and sulfur suggesting a possible occurrence of regolith-derived secondary mineral assemblages in these samples. Previously, we have studied two GRIM glasses, 506 and 507, from EET79001 Lith A and Lith B, respectively, for elemental abundances and spatial distribution of sulfur using EMPA (WDS) and FE-SEM (EDS) techniques and for sulfur-speciation using K-edge XANES techniques. These elemental and FE-SEM micro-graph data at several locations in the GRIM glasses from Shergotty (DBS), Zagami 994 and EET79001, Lith B showed that FeO and SO3 are positively correlated (SO3 represents a mixture of sulfide and sulfate). FE-SEM (EDS) study revealed that the sulfur-rich pockets in these glasses contain numerous micron-sized iron-sulfide (Fe-S) globules sequestered throughout the volume. However, in some areas (though less frequently), we detected significant Fe-S-O signals suggesting the occurrence of iron sulfate. These GRIM glasses were studied by K-edge microXANES techniques for sulfur speciation in association with iron in sulfur-rich areas. In both samples, we found the sulfur speciation dominated by sulfide with minor oxidized sulfur mixed in with various proportions. The abundance of oxidized sulfur was greater in 506 than in 507. Based on these results, we hypothesize that sulfur initially existed as sulfate in the glass precursor materials and, on shock-impact melting of the precursor materials producing these glasses, the oxidized sulfur was reduced to predominately sulfide. In order to further test this hypothesis, we have used microXANES to measure the valence states of vanadium in GRIM glasses from Lith A and Lith B to complement and compare with previous analogous measurements on Lith C (note: 506 and 507 contain the largest amounts of martian atmospheric gases but the gas-contents in Lith C measured by are unknown). Vanadium is ideal for addressing this re-dox issue because it has multiple valence states and is a well-studied element. Ferrous-dominated iron valences determined by microXANES on the Lith A and Lith B glasses provide little redox sensitivity. Vanadium valence measurements for impact glass in Lith C at three different locations yielded valence values of 3.1, 3.2 and 3.4 with inferred fO2 values of IW-0.7, IW-0.1 and IW+0.7, respectively. This range of oxygen-fugacity values is understandable because the glasses are shock-molten impact glasses which are heterogeneous in nature. Oxygen fugacity values obtained from the analysis of Fe-Ti oxides and Eu partitioning in pyroxenes from EET79001 Lith A and Lith B (host lithologies) were in the range of IW+0.3 to IW+1.9 suggesting that V in the Lith C impact glass was reduced in the impact process. Here, we examine whether the 506 from Lith A and 507 from Lith B GRIM glasses yield similar or different fO2 values from those of Lith C using the vanadium K-edge microXANES technique.

Sutton, S. R.↗

A Multi-Sensor, Low Volume, Automated Culture System for Space Biology Experiments

Optical density (absorbance) is commonly used in microbiology to measure cell concentration and other colorimetric indicators. It is the main type of bioscience data returned from the BioSentinel small spacecraft mission, which was recently launched as a secondary payload on Artemis I. The flight unit takes absorbance measurements of yeast cultures at 570 nm, 630 nm, and 850 nm to track cell concentration and oxidation-reduction (redox) state of the metabolic indicator dye alamarBlue over time [1]. Because the data returned from a small spacecraft mission is necessarily limited, BioSentinel uses a specialized ground-based experiment apparatus to map the absorbance data onto several other parameters. This culture apparatus is composed of a polycarbonate base and lid which contain ports for several commercial sensors, including a standard 12 mm dissolved oxygen probe, gaseous CO2, fluid pressure, and two micro-probes for measuring pH and redox potential. It also contains a pressure relief valve, a rubber membrane for culture interaction, and a 12mm port for the custom optical probe designed to match in-flight measurements. Modules in two corners expand the culture volume into narrow columns, enabling solid-state optical density measurement and dielectric spectroscopy. The apparatus can be fit to a plate for magnetic stirring. The apparatus’s optical probe allows mapping between the flight unit’s optical data and the additional parameters measured by the ground-based experiments. Within the probe, a linear actuator pulls a plunger, drawing culture volume into the optical path. The actuator then pushes out the plunger and culture volume, cleaning any stray yeast from the inside surface of the probe. The probe chassis is 3D-printed from biocompatible resin with the optoelectronics cured inside an optically clear conformal coat which functions as a lens. To optimize the probe’s dimensions, including optical path, a test harness was developed to manipulate and measure distance while the LED light sources and photodiode detector are in operation. The test harness was composed of two 3/64” thick polycarbonate plates mounted to a set of calipers. The LEDs and photodiode were mounted on the outside of each plate. A cuvette of sample fluid was then clamped between the plates in line between the LEDs and photodiode. The test harness generated a 78% signal change between water and a dye standard for the green (570 nm) LED, a 90% signal change for the red (630 nm) LED, and a 25% signal change between water and overgrown yeast for the infrared (850 nm) LED. The improvements to the ground experiment apparatus (culture volume reduction, inclusion of an optical probe to measure flight-like optical data, and magnetic stirring for culture homogeneity) allow for more flight-like measurements to be taken and more accurate mapping of these additional parameters to the optical data returned from the flight unit. This enhancement to mission science return will give insight into how deep space radiation may affect human biology for future long-term space exploration.

Multi-Sensor↗

Sulfur speciation in dacitic melts using X-ray absorption near-edge structure spectroscopy of the S K -edge (S-XANES): Consideration of radiation-induced changes and the implications for sulfur in natural arc systems

Abstract The synchrotron technique of micro X-ray absorption near-edge structure spectroscopy at the sulfur K-edge (S-XANES) provides a unique opportunity to measure the proportion of different oxidation states of sulfur (S) in silicate glasses. Although applied extensively in the analysis of basaltic silicate glasses, few S-XANES studies have investigated variations in S oxidation states with fO2 in felsic silicate glasses. In addition, no study has systematically compared the S-XANES results obtained from the same samples at different photon flux densities to quantify the relationship between exposure time and changes in S speciation in silicate glass, as has been done for Fe and V. This study evaluates observed differences in S speciation measured in experimentally produced H2O-saturated dacitic glasses over a range of reducing to oxidizing conditions (from log fO2 = ΔFMQ-0.7 to ΔFMQ+3.3; FMQ is the fayalite-magnetite-quartz mineral redox buffer) and equilibrated at 1000 °C and 300 MPa. S-XANES spectra were collected at three different photon flux densities using three microspectroscopy beamlines. As is observed in S-XANES analyses of basaltic silicate glasses, beam-induced changes to the S6+/ΣS are observed as a function of photon flux density and beam exposure time. Our results demonstrate that silicate glasses of dacitic composition undergo beam-induced photo-reduction in samples equilibrated at ΔFMQ > +1.75 and photo-oxidation if equilibrated at ΔFMQ < +1. The time required to observe beam-induced changes in the spectra varies as a function of flux density, and our study establishes an upper photon density limit at ~1.0 × 1012 photons/µm2. The S6+/ΣS calculated from spectra collected below this absorbed photon limit at intermediate flux densities (~1–4 × 109 photons/s per µm2) are affected by beam damage, as no conditions were found to be completely free of beam-induced changes. However, the S6+/ΣS ratios calculated below the limit at intermediate flux densities are consistent with thermodynamic constraints, demonstrating that S6+/ΣS ratios calculated from S-XANES spectra can be considered reliable for estimating the oxygen fugacity. Our results carry important implications for the S budget of felsic magmas and dissolution mechanisms in evolved melts. While our results from all three flux densities show the presence of S4+ dissolved in relatively oxidized (ΔFMQ > +1.75) dacitic glass, even in the spectra exposed to the lowest photon densities, we are unable to rule out the possibility that the S4+ signal is the result of instantaneous X-ray irradiation induced beam damage using S-XANES alone. When our spectra are compared to S-XANES spectra from basaltic silicate glasses, important differences exist in the solubility of S2– and S6+ between dacitic silicate melts, pointing to differences in solubility mechanisms as melt composition changes. This study highlights the need for further investigation into beam damage systematics, presence of S4+, and the solubility mechanisms of different oxidation states of S as silicate melt composition changes.

Geochemistry & Geophysics↗

Functional roles of the [2Fe-2S] clusters in Synechocystis PCC 6803 Hox [NiFe]-hydrogenase reactivity with ferredoxins

The HoxEFUYH complex of Synechocystis PCC 6803 (S. 6803) consists of a HoxEFU ferredoxin:NAD(P)H oxidoreductase subcomplex and a HoxYH [NiFe]-hydrogenase subcomplex that catalyzes reversible H2 oxidation. Prior studies have suggested that the presence of HoxE is required for reactivity with ferredoxin; however, it is unknown how HoxE is functionally integrated into the electron transfer network of the HoxEFU:ferredoxin complex. Deciphering electron transfer pathways is challenged by the rich iron-sulfur cluster content of HoxEFU, which includes a [2Fe-2S] cluster in each subunit, along with multiple [4Fe-4S] clusters and a flavin cofactor. To resolve the role of HoxE, we determined the biophysical and thermodynamic properties of each [2Fe-2S] cluster in HoxEFU using steady-state and potentiometric EPR analysis in combination with square wave voltammetry (SWV). The temperature-dependence of the EPR signal for HoxE confirmed the coordination of a single [2Fe-2S] cluster that was shown by SWV to have an E m = -424 mV (versus SHE). Strikingly, when the E m of the HoxE [2Fe-2S] cluster was analyzed in HoxEFU titrations, it was shifted by >100 mV to an E m < -525 mV (versus SHE). EPR titrations of HoxEFU gave an E m value for the [2Fe-2S] cluster of HoxF, E m = -419 mV and HoxU, E m = -349 mV. These values were used to re-analyze the diaphorase kinetics in reactions performed with ferredoxins with varying E m 's. The results are formulated into a model of HoxEFU:ferredoxin reactivity and the role of HoxE in mediating electron transfer within the HoxEFU:ferredoxin complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating Electron Storage and Distribution within the Pentaheme Scaffold of Cytochrome c Nitrite Reductase (NrfA)

Cytochrome c nitrite reductases (CcNIR or NrfA) play important roles in the global nitrogen cycle by conserving the usable nitrogen in the soil. Here, the electron storage and distribution properties within the pentaheme scaffold of Geobacter lovleyi NrfA were investigated via EPR spectroscopy coupled with chemical titration experiments. Initially, a chemical reduction method was established to sequentially add electrons to the fully oxidized protein, one equivalent at a time. The step–by–step reduction of the hemes was then followed using UV–Vis and EPR spectroscopy. EPR–spectral simulations elucidate the sequence of heme reduction within the pentaheme scaffold, and identify the signals of all five hemes in the EPR spectra. Electrochemical experiments ascertain the reduction potentials for each heme, observed in a narrow +11 (Heme 5) to –212 mV (Heme 3) range (vs SHE). Based on quantitative analysis/simulation of the EPR data, we demonstrate that Hemes 4 and 5 are reduced first (before the active site Heme 1) and serve the purpose of an electron storage unit within the protein. To probe the role of the central Heme 3, a H108M NrfA variant was generated where the reduction potential of Heme 3 is shifted positively (from –212 mV to +29 mV). Here, the H108M mutation significantly impacts the distribution of electrons within the pentaheme scaffold and the reduction potentials of the hemes, reducing the catalytic activity of the enzyme to 3% compared to wild–type. We propose that this is due to Heme 3’s important role as an electron gateway in the wild–type enzyme.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

From remotely sensed solar-induced chlorophyll fluorescence to ecosystem structure, function, and service: Part I—Harnessing theory

Solar-induced chlorophyll fluorescence (SIF) is a remotely sensed optical signal emitted during the light reactions of photosynthesis. The past two decades have witnessed an explosion in availability of SIF data at increasingly higher spatial and temporal resolutions, sparking applications in diverse research sectors (e.g., ecology, agriculture, hydrology, climate, and socioeconomics). These applications must deal with complexities caused by tremendous variations in scale and the impacts of interacting and superimposing plant physiology and three-dimensional vegetation structure on the emission and scattering of SIF. At present, these complexities have not been overcome. To advance future research, the two companion reviews aim to (1) develop an analytical framework for inferring terrestrial vegetation structures and function that are tied to SIF emission, (2) synthesize progress and identify challenges in SIF research via the lens of multi-sector applications, and (3) map out actionable solutions to tackle these challenges and offer our vision for research priorities over the next 5-10 years based on the proposed analytical framework. This paper is the first of the two companion reviews, and theory oriented. It introduces a theoretically rigorous yet practically applicable analytical framework. Guided by this framework, we offer theoretical perspectives on three overarching questions: (1) The forward (mechanism) question—How are the dynamics of SIF affected by terrestrial ecosystem structure and function? (2) The inference question: What aspects of terrestrial ecosystem structure, function, and service can be reliably inferred from remotely sensed SIF and how? (3) The innovation question: What innovations are needed to realize the full potential of SIF remote sensing for real-world applications under climate change? In conclusion, the analytical framework elucidates that process complexity must be appreciated in inferring ecosystem structure and function from the observed SIF; this framework can serve as a diagnosis and inference tool for versatile applications across diverse spatial and temporal scales.

59 BASIC BIOLOGICAL SCIENCES↗