Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ray trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SHADOW4: the popular ray tracing revived for evolving synchrotron sources in fourth-generation storage rings

We present SHADOW4, a new version of the popular ray tracing code. The SHADOW kernel has been completely rewritten in Python applying modern concepts of software engineering. A new user interface is available in the OASYS ecosystem. The new tool has been designed and implemented preparing the future needs both in computing (cloud computing, AI integration) and in the transit to fourth generation sources and beyond.

Sanchez del Rio, Manuel↗

SU-E-T-85: Comparison of Treatment Plans Calculated Using Ray Tracing and Monte Carlo Algorithms for Lung Cancer Patients Having Undergone Radiotherapy with Cyberknife

Purpose: The latest publications indicate that the Ray Tracing algorithm significantly overestimates the dose delivered as compared to the Monte Carlo (MC) algorithm. The purpose of this study is to quantify this overestimation and to identify significant correlations between the RT and MC calculated dose distributions. Methods: Preliminary results are based on 50 preexisting RT algorithm dose optimization and calculation treatment plans prepared on the Multiplan treatment planning system (Accuray Inc., Sunnyvale, CA). The analysis will be expanded to include 100 plans. These plans are recalculated using the MC algorithm, with high resolution and 1% uncertainty. The geometry and number of beams for a given plan, as well as the number of monitor units, is constant for the calculations for both algorithms and normalized differences are compared. Results: MC calculated doses were significantly smaller than RT doses. The D95 of the PTV was 27% lower for the MC calculation. The GTV and PTV mean coverage were 13 and 39% less for MC calculation. The first parameter of conformality, as defined as the ratio of the Prescription Isodose Volume to the PTV Volume was on average 1.18 for RT and 0.62 for MC. Maximum doses delivered to OARs was reduced in the MC plans. The doses for 1000 and 1500 cc of total lung minus PTV, respectively were reduced by 39% and 53% for the MC plans. The correlation of the ratio of air in PTV to the PTV with the difference in PTV coverage had a coefficient of −0.54. Conclusion: The preliminary results confirm that the RT algorithm significantly overestimates the dosages delivered confirming previous analyses. Finally, subdividing the data into different size regimes increased the correlation for the smaller size PTVs indicating the MC algorithm improvement verses the RT algorithm is dependent upon the size of the PTV.

60 APPLIED LIFE SCIENCES↗

Adaptive inverse ray-tracing for accurate and efficient modeling of cross beam energy transfer in hydrodynamics simulations

Integrated hydrodynamics simulations of inertial confinement fusion rely on reduced physics models. To reproduce experimental trends, these models often feature tuning parameters, but this comes with a risk: the over-tuning of one model can hide physics inadequacies in another. The ray-based models of cross-beam-energy transfer (CBET) represent this risk. In this paper, we present an accurate and efficient model of CBET suitable for inline implementation in 3D hydrodynamics simulations. Inverse Ray Tracing (IRT) is used to compute the ray field in a 3D permittivity profile described on an unstructured tetrahedral mesh using the Inline Field Reconstruction and Interaction using Inverse Tracing framework. CBET is accounted for through perturbations to the permittivity associated with ion acoustic waves driven by the overlapped fields. Large gradients in the permittivity are resolved by coupling the IRT to a recursive Adaptive Mesh Refinement (AMR) algorithm. The use of AMR also allows for the resolution of caustics, with accurate field reconstruction performed using the Etalon integral method. Comparisons of the model with wave-based solutions from the Laser Plasma Simulation Environment demonstrate its ability to control energy conservation and gain convergence through the AMR depth only, without the use of ad hoc physical models or artificial tuning parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A model of polarized-beam AGS in the ray-tracing code Zgoubi

A model of the Alternating Gradient Synchrotron, based on the AGS snapramps, has been developed in the stepwise ray-tracing code Zgoubi. It has been used over the past 5 years in a number of accelerator studies aimed at enhancing RHIC proton beam polarization. It is also used to study and optimize proton and Helion beam polarization in view of future RHIC and eRHIC programs. The AGS model in Zgoubi is operational on-line via three different applications, ’ZgoubiFromSnaprampCmd’, ’AgsZgoubiModel’ and ’AgsModelViewer’, with the latter two essentially interfaces to the former which is the actual model ’engine’. All three commands are available from the controls system application launcher in the AGS ’StartUp’ menu, or from eponymous commands on shell terminals. Main aspects of the model and of its operation are presented in this technical note, brief excerpts from various studies performed so far are given for illustration, means and methods entering in ZgoubiFromSnaprampCmd are developed further in appendix.

43 PARTICLE ACCELERATORS↗

Propagation predictions and studies using a ray tracing program combined with a theoretical ionospheric model

Radio wave propagation predictions are described in which modern comprehensive theoretical ionospheric models are coupled with ray-tracing programs. In the computer code described, a network of electron density and collision frequency parameters along a band about the great circle path is calculated by specifying the transmitter and receiver geographic coordinates, time, the day number, and the 2800-MHz solar flux. The ray paths are calculated on specifying the frequency, mode, range of elevation angles, and range of azimuth angles from the great circle direction. The current program uses a combination of the Penn State MKI E and F region models and the Mitra-Rowe D and E region model. Application of the technique to the prediction of satellite to ground propagation and calculation of oblique incidence propagation paths and absorption are described. The implications of the study to the development of the next generation of ionospheric models are discussed.

Lee, M. K.↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Ray tracing studies of Jupiter's magnetosphere

Raypaths for decametric wavelength radiation in Jupiter's magnetosphere were calculated. The model-dependent raypaths with the Voyager observations were compared. Characteristics of the source regions and the influence of propagation effects were deduced. A three dimensional ray tracing program was employed to calculate the raypaths. Families of rays were launched at particular angles with respect to the magnetic field lines to generate conical sheets of radiation for various frequencies and various source locations. As the planet's magnetic field rotates, these warped sheets of radiation sweep past the observer, producing signatures in frequency versus time plots. These signatures match some of those found in the Voyager data. The greatest propagation effects occur in and around the source regions in the Io auroral oval.

Six, N. F.↗

Characteristics of thermospheric infrasound predicted using ray tracing and weakly non-linear waveform analyses

Infrasonic signals refracted by thermal gradients in the rarefied upper atmosphere are modeled using a combination of ray tracing and weak shock theory to develop an understanding of thermospheric infrasound signals produced by energetic, transient sources. Canonical arrival structures in the form of u-wave signatures are identified for returns refracted at lower altitudes within the thermosphere, and possible multi-pathing produced by effective sound speed inflections are investigated to elucidate more complex arrival structures, which are found to be spatially localized. Furthermore, variability in the source characteristics is investigated and it is found that whereas some waveform phase information is lost due to finite amplitude effects, arrival characteristics are strongly dependent on the peak overpressure near the source. Variability in the propagation path is considered using archived atmospheric specifications and implies that despite uncertainties related to the dynamic and sparsely sampled nature of the atmosphere, thermospheric signatures might be useful in estimating the yield for explosive sources. Last, thermospheric arrivals from a failed rocket launch, as well as those from several large chemical explosions, are analyzed and it is found that qualitative trends match those predicted, and analyses here provide additional insight into such signatures.

42 ENGINEERING↗

Ray tracing evaluation of a technique for correcting the refraction errors in satellite tracking data

Errors may be introduced in satellite laser ranging data by atmospheric refractivity. Ray tracing data have indicated that horizontal refractivity gradients may introduce nearly 3-cm rms error when satellites are near 10-degree elevation. A correction formula to compensate for the horizontal gradients has been developed. Its accuracy is evaluated by comparing it to refractivity profiles. It is found that if both spherical and gradient correction formulas are employed in conjunction with meteorological measurements, a range resolution of one cm or less is feasible for satellite elevation angles above 10 degrees.

Gardner, C. S.↗

Ray tracing on the MPP

Generating graphics to faithfully represent information can be a computationally intensive task. A way of using the Massively Parallel Processor to generate images by ray tracing is presented. This technique uses sort computation, a method of performing generalized routing interspersed with computation on a single-instruction-multiple-data (SIMD) computer.

Dorband, John E.↗

SU-E-T-587: Monte Carlo Versus Ray-Tracing for Treatment Planning Involving CNS Tumors On the MultiPlan System for CyberKnife Radiosurgery

Purpose: MultiPlan, the treatment planning system for the CyberKnife Robotic Radiosurgery system offers two approaches to dose computation, namely Ray-Tracing (RT), the default technique and Monte Carlo (MC), an option. RT is deterministic, however it accounts for primary heterogeneity only. MC on the other hand has an uncertainty associated with the calculation results. The advantage is that in addition, it accounts for heterogeneity effects on the scattered dose. Not all sites will benefit from MC. The goal of this work was to focus on central nervous system (CNS) tumors and compare dosimetrically, treatment plans computed with RT versus MC. Methods: Treatment plans were computed using both RT and MC for sites covering (a) the brain (b) C-spine (c) upper T-spine (d) lower T-spine (e) L-spine and (f) sacrum. RT was first used to compute clinically valid treatment plans. Then the same treatment parameters, monitor units, beam weights, etc., were used in the MC algorithm to compute the dose distribution. The plans were then compared for tumor coverage to illustrate the difference if any. All MC calculations were performed at a 1% uncertainty. Results: Using the RT technique, the tumor coverage for the brain, C-spine (C3–C7), upper T-spine (T4–T6), lower T-spine (T10), Lspine (L2) and sacrum were 96.8%, 93.1%, 97.2%, 87.3%, 91.1%, and 95.3%. The corresponding tumor coverage based on the MC approach was 98.2%, 95.3%, 87.55%, 88.2%, 92.5%, and 95.3%. It should be noted that the acceptable planning target coverage for our clinical practice is >95%. The coverage can be compromised for spine tumors to spare normal tissues such as the spinal cord. Conclusion: For treatment planning involving the CNS, RT and MC appear to be similar for most sites but for the T-spine area where most of the beams traverse lung tissue. In this case, MC is highly recommended.

60 APPLIED LIFE SCIENCES↗

Distance corrections for single- and dual-color lasers by ray tracing

The physical arc length difference between the red and blue beam of a dual-color laser generates an error term in determining Delta-n as well as n (the refractive index) and D (the line length). Numerical ray trace examples and theoretical approximations show that the resulting relative error Delta-D/D increases as D-squared. Error reduction by a factor of nearly 10 is possible by using the pressure, temperature, and humidity of both endpoints to calculate n. The present study results from a desire to improve the precision of monitoring the local and regional position of the Lunar Laser Ranging Observatory atop Haleakala, Maui, Hawaii; the monitoring of the earth's crustal deformation and strain is a primary concern of the study.

Berg, E.↗

Indoor Wireless Localization of Uncooperative Sources Using a Ray Tracing Model

Indoor geolocation of radio frequency (RF) trans- mitters is challenging due to site-specific multipath effects, especially when the sources are uncooperative. A source being uncooperative means that a-priori the transmit time, location, and power are unknown. It is proposed to use a site-specific ray tracing model to generate realistic indoor RF responses, perform geolocation using multiple methods, and compare their performance. This work will look at two types of geolocation algorithms: (1) time-difference of arrival (TDOA) and (2) re- ceived signal strength Indicator (RSSI) fingerprinting or pattern- matching-based methods. An indoor space will be simulated with a grid of fixed receivers and a grid of transmit locations using Remcom’s Wireless InSite. Using the output of the Wireless InSite simulation the response from any given transmit location can be generated and used to evaluate geolocation performance.

indoor source localization, Wireless InSite, re- c↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index

Optical images of transparent three-dimensional objects can be different from a replica of the object’s cross section in the image plane, due to refraction at the surface or in the body of the object. Simulations of the object’s image are thus needed for the visualization and validation of physical models. We report ray tracing image simulations that achieved high physical fidelity, reproducing optical behaviors and image features not rendered in previous studies. We replicated brightfield microscopy images of drops with complex shapes, and images of pressure and shock waves traveling inside them. For high physical fidelity, the simulations must replicate the spatial and angular distribution of illumination rays, and both the experiment and the simulation must be designed for accurate optical modeling. The simulations are highly sensitive to the properties of the drops and can be used to diagnose and refine fluid dynamics models. The simulated images can also be optimized to extract multiple 3D properties from experimental images. Compared to specialized single-shot 3D imaging methods, this approach has the advantage that it preserves the experimental simplicity, the high resolution, and the visual interpretability characteristic to basic optical imaging. The techniques introduced here are directly applicable to optical microscopy, so they can be used in other fields, such as microfluidics and biology, to expand the type and the accuracy of three-dimensional information that can be extracted from basic optical images.

Cavitation↗

A parameterized ray-tracing model for evaluation of hemispherical lensing of a uniform, telecentric object aperture -- performance improvement estimates for segmented scintillators with miniature lens arrays

A parametric model describing the collimation of radiation from a uniform circular aperture by a hemispherical lens of the same radius has been developed for rapid estimation of the potential benefit of miniature dielectric lens arrays in lens-coupled gamma ray cameras (GRCs) with segmented scintillators. A simplified ray-tracing approach is adopted that makes use of small angle approximations relevant to GRCs used in nuclear science at Los Alamos National Laboratory and elsewhere. Application of this analysis technique in a first-pass design optimization process results in the optimistic estimate that miniature lenses fabricated from typical optical quality glass might boost optical coupling by as much as a factor of 4 (6 dB gain). However, this is not likely to be economically attractive compared to other techniques, such as reduction of the GRC lens f-number.

47 OTHER INSTRUMENTATION↗

Reasonable Beam Deviation Envelope for Ray-tracing

At NSLS-II the unused dipole radiation is intercepted by the photon absorbers installed inside the vacuum chamber. The water-cooled absorbers are designed to take away the heat therefore the temperature is kept within the safety limit. However, if the beam orbit is severely perturbed, the radiation fan could pass through the geometry and strikes on the vacuum chamber components. This ray-leakage is a possible reason of the accelerator component temperature rise observed during the high-current operations. The goal of this work is to find the maximum beam deviation at the dipole hence ray-tracing can be re-examined under the operational constraints. The beam is confined to the orbit by the bending and focusing magnets. At NSLS-II the orbit is further controlled by a real time orbit feedback loop. Beam could be lost in any unpredictable direction if the magnet malfunctions. Consequently reasonable assumptions must be made to define the deviation envelope. It was determined that the dipole radiation is not powerful enough to cause damage within 10 ms, for example, if the rf power is shut off and the beam deviates from the orbit. Therefore we consider the radiation produced by the stored beam only; temporarily processes, such as unstable oscillating beam, should not be a concern. The orbit of the stored beam can be altered during magnet failures. The dipole current is interlocked to a small range of ±2% from the nominal value. If the dipole current changes slowly the beam energy automatically adjusts and the orbit remains the same. If the dipole current changes rapidly the beam will not be stable. Therefore dipole variation need not to be considered. For the other magnets we consider one magnet failure at a time because it is unlikely that two fail at the same time. It was found that the beam lifetime drops dramatically if one quadrupole power supply is turned off; therefore this scenario does not meet the stable beam condition. The current of one quadrupole could drop but will not result in orbit change with the feedback on. Beam could survive if one sextupole power supply is turned off, but the orbit will not be changed. Magnet could partially fail, for example, one or part of the coil shorts due to break-down. This is a low probability event and will not be considered. During daily operations the orbit is changed by the correctors and the rf frequency. In this work the correctors and the rf frequency are varied to explore the deviation envelope.

36 MATERIALS SCIENCE↗