Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raster”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Infrared imaging of Jupiter in the 8-14-micrometer spectral region

High-spatial-resolution images of Jupiter were produced on the Hale 200-in. telescope. A programmable wobbling secondary was used to raster-scan the planet with 64 by 64 1-arcsec pixels. Images were made with broadband (8-14 microns) and several 1- and 2-micron-wide filters. All images reveal a belt-and-ozone structure similar to visible photographs. Belts in the broadband data appear to be about 2 K hotter than zones, but contrast varies markedly in different parts of the 8-14-micron spectral region. The lowest belt-zone contrast is found in the hydrogen-opacity-dominated region at 12.5 microns, while images at 9.5 microns exhibit the greatest contrast. Isolated areas are observed to be as much as 4 K hotter than surrounding areas at 9.5 microns. This large contrast is probably due to variations in the distribution of the ammonia clouds in the upper atmosphere.

Terrile, R. J.↗

Dynamics and control simulation of the Spacelab Experiment Pointing Mount

Computer simulations were developed to evaluate the performance of four Experiment Pointing Mounts (EPM) being considered for Spacelab experiments in the 1980-1990 time frame. The system modeled compromises a multibody system consisting of the shuttle, a mechanical isolation device, the EPM, celestial and inertial sensors, bearings, gimbal torque motors and associated nonlinearities, the experiment payload, and control and estimator algorithms. Each mount was subjected to a common disturbance (shuttle vernier thruster firing and man push off) and command (stellar pointing or solar raster scan) input. The fundamental limitation common to all mounts was found to be sensor noise. System dynamics and hardware nonlinearities have secondary effects on pointing performance for sufficiently high bandwidth.

Marsh, E. L.↗

Multiple-input land-use system concept

Image based information system would accept data in a variety of formats and convert it to registered raster-scan with single format. Images could then be manipulated by system processor to read out desired information. Existing methods of digital-image processing could be modified to develop necessary software and hardware needed to implement system.

Billingsley, F. C.↗

Measurement of subcoat thickness by characteristic x-rays

Technique employs x-ray scanning system to measure thickness of topcoat and subcoat of heat shields and other ceramic materials. System scans sample in raster pattern and depicts image of structure on cathode-ray-tube for viewing or photocopying within seconds.

Harris, W. J.↗

Holographic analyzer and image scanner

The characteristics, components, and operating procedures are described for a holographic camera real images projection displayer and scanner unit having the capability to upgrade to multiple types of automated raster scan patterns. Schematics of the optical components are included with a diagram of the electric circuit connections.

Source record↗

Preliminary design analysis for the solar optical telescope main mirror actuator

The resolution of the SOT Gregorian telescope was maintained if the conic foci of the elliptical secondary and parabolic primary were made to coincide within plus or minus 38 microns across the prime focus plane and to within 5 microns in focus. An error in coincidence across the focal plane caused all point images to show additional coma with all the comatic tails pointing in the same direction. An error in focus became magnified by the square of the magnification of the secondary and simply increased the diameter of the point source. Offsetting or rastering the sun may be accomplished by swinging the primary in an arc about the point of coincidence of the conic foci so long as the coincidence is kept to within the tolerance stated.

Dunn, R. B.↗

Digital image centering. II

Digital image centering algorithms were compared in a test involving microdensitometer raster scans of a refractor parallax series consisting of 22 stars on 26 plates. The highest accuracy in determining stellar image positions was provided by an algorithm which involved fitting of a symmetric Gaussian curve and a flat background to the image marginal density distributions. Algorithms involving transmission marginals instead of density marginals were found to be less accurate. The repeatability and computational efficiency of the digital image centering technique were also studied.

Auer, L. H.↗

Coupling apparatus for ultrasonic medical diagnostic system

An apparatus for the ultrasonic scanning of a breast or other tissue is reported that contains a cavity for receiving the breast, a vacuum for drawing the breast into intimate contact with the walls of the cavity, and transducers coupled through a fluid to the cavity to transmit sound waves through the breast. Each transducer lies at the end of a tapered chamber which has flexible walls and which is filled with fluid, so that the transducer can be moved in a raster pattern while the chamber walls flex accordingly, with sound transmission always occurring through the fluid.

Frazer, R. E.↗

Application of an electron beam facility for heat transfer measurements in capillary tubes

A unique method was developed for the determination of heat transfer coefficients for water flowing through capillary tubes using a rastered electron beam heater. Heat flux levels of 150 and 500 watts/sq cm were provided on the top surface of four square tubes. Temperature gradient along the tube length and mass flow rates versus pressure drop were measured.

Lunde, A. R.↗

Effects of space environment on composites: An analytical study of critical experimental parameters

A generalized methodology currently employed at JPL, was used to develop an analytical model for effects of high-energy electrons and interactions between electron and ultraviolet effects. Chemical kinetic concepts were applied in defining quantifiable parameters; the need for determining short-lived transient species and their concentration was demonstrated. The results demonstrates a systematic and cost-effective means of addressing the issues and show qualitative and quantitative, applicable relationships between space radiation and simulation parameters. An equally important result is identification of critical initial experiments necessary to further clarify the relationships. Topics discussed include facility and test design; rastered vs. diffuse continuous e-beam; valid acceleration level; simultaneous vs. sequential exposure to different types of radiation; and interruption of test continuity.

Gupta, A.↗

The XUV spectroheliometer on SMM

The XUV spectroheliometer for the Solar Maximum Mission (SMM) is described. This instrument is a grazing-incidence polychromatic photoelectric spectrometer illuminated by a grazing-incidence telescope mirror. The wavelength range is 20-1336 A, the spectral resolution is between 0.1 and 0.3 A, and the spatial resolution is 4 arcsec. Simultaneous spectroheliograms in twelve spectral lines are obtained by rastering the instrument at variable rates. The scientific objectives and the mission operations concept are also described.

Reeves, E. M.↗

Soft X-ray emission from the Lupus Loop and Sn 1006 supernova remnants

X-ray maps of the Lupus region have been obtained in a raster scan observation from SAS 3. These show the Lupus Loop to be a faint extended source of soft X-rays with a temperature about 2.5 million K. The most prominent feature of the region is the A.D. 1006 supernova remnant, which is unexpectedly bright at 0.2-1.0 keV. One speculative interpretation of the low-energy flux from SN 1006 is as blackbody radiation from a hot neutron star.

Winkler, P. F., Jr.↗

Thermal design concept for a high resolution UV spectrometer

The thermal design concept described has been developed for the High Resolution UV Spectrometer/Polarimeter to be flown on the Solar Maximum Mission. Based on experience gained from a similar Orbiting Solar Observatory mission payload, it has been recognized that initial protection of the optical elements, contamination control, reduction of scattered light, tight bulk temperature, and gradient constraints are key elements that must be accommodated in any thermal control concept for this class of instrument. Salient features of the design include: (1) a telescope door providing contamination protection of an aplanatic Gregorian telescope; (2) a rastering system for the secondary mirror; (3) a unique solar heat absorbing device; (4) heat pipes and special radiators; (5) heaters for active temperature control and optics contamination protection; and (6) high precision platinum resistance thermometers. Viability of the design concept has been established by extensive thermal analysis and some subsystem testing. A summary of analytical and test results is included.

Caruso, P.↗

The JPL flux mapper

The flux mapper is a device that can map the intensity distribution in three dimensions of concentrated solar energy at the focus of a concentrator. Intensities to 10,000 solar constants can be measured. Constructed to assist in concentrator and receiver development, it consists of a radiometer which is moved through the concentrated sunlight in a series of planes perpendicular to the optical axis by means of a mechanical rastering device. Various radiometer probes can be utilized depending on the time and accuracy requirements of the program. Energy levels are recorded as a function of location. Reduction of this data can be in various formats, e.g., contour maps, digital arrays, isometric visualizations and other displays as the user requires.

Owen, W. A.↗

A study of acoustic heating and forced convection in the solar corona

The S055 EUV spectra was used to perform emission measure and line intensity ratio analyses of loop plasma conditions in a study on the thermodynamics of magnetic loops in the solar corona. The evidence that loops contain plasma hotter than the background corona, and thus, require enhanced local dissipation of magnetic or mechanical energy is discussed. The S055 EUV raster pictures were used to study physical conditions in cool ultraviolet absorbing clouds in the solar corona, and optical data were used to derive constraints on the dimension, time scales and optical depths in dark opaque clouds not seen in H alpha and CaK as filaments or prominences. Theoretical modelling of propagation of magnetically guided acoustic shocks in the solar chromosphere finds it still unlikely that high frequency acoustic shocks could reach the solar corona. Dynamic modelling of spicules shows that such guided slow mode shocks can explain the acceleration of cool spicular material seen high in the corona.

Foukal, P. V.↗

Procurement specification color graphic camera system

The performance and design requirements for a Color Graphic Camera System are presented. The system is a functional part of the Earth Observation Department Laboratory System (EODLS) and will be interfaced with Image Analysis Stations. It will convert the output of a raster scan computer color terminal into permanent, high resolution photographic prints and transparencies. Images usually displayed will be remotely sensed LANDSAT imager scenes.

Prow, G. E.↗

Solar maximum ultraviolet spectrometer and polarimeter

The objectives of the UVSP experiment are to study solar ultraviolet radiations, particularly from flares and active regions, and to measure constituents in the terrestrial atmosphere by the extinction of sunlight at satellite dawn and dusk. The instrument is designed to observe the Sun at a variety of spectral and spatial resolutions in the range from 1150 to 3600 A. A Gregorian telescope with effective focal length of 1.8 m is used to feed a 1 m Ebert-Fastie spectrometer. A polarimeter containing rotatable magnesium fluoride waveplates is included behind the spectrometer entrance slit and will allow all four Stokes parameters to be determined. Velocities on the Sun can also be measured. The instrument is controlled by a computer which can interact with the data stream to modify the observing program. The observing modes, including rasters, spectral scans, velocity measurements, and polarimetry, are also described along with plans for mission operations, data handling, and analysis of the observations.

Tandberg-Hanssen, E.↗

The Ultraviolet Spectrometer and Polarimeter on the Solar Maximum Mission

The Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission spacecraft is described, including the experiment objectives, system design, performance, and modes of operation. The instrument operates in the wavelength range 1150-3600 A with better than 2 arcsec spatial resolution, raster range 256 x 256 sq arcsec, and 20 mA spectral resolution in second order. Observations can be made with specific sets of four lines simultaneously, or with both sides of two lines simultaneously for velocity and polarization. A rotatable retarder can be inserted into the spectrometer beam for measurement of Zeeman splitting and linear polarization in the transition region and chromosphere.

Woodgate, B. E.↗