Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Qualifying the Instrument Thimble 11 Test Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Findings in Qualifying the Instrument Thimble 11 Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Demonstration of a laser-driven, narrow spectral bandwidth x-ray source for collective x-ray scattering experiments

X-ray Thomson scattering (XRTS) is a powerful diagnostic technique that involves an x-ray source interacting with a dense plasma sample, resulting in a spectrum of elastically and inelastically scattered x-rays. Depending on the plasma conditions, one can measure a range of parameters from the resulting spectrum, including plasma temperature, electron density, and ionization state. To achieve sensitivity to collective electron oscillations, XRTS measurements require limited momentum transfer where the spectral separation of elastic and inelastic scattering is small. Such measurements require an x-ray probe source with a narrow bandwidth in order to reduce the spectral overlap between scattering contributions, allowing for the different features to be more precisely deconvolved. In this investigation, we discuss the theory behind how the bandwidth for a common XRTS probe, Zn He-α emission at 9 keV, can be reduced using a Cu K-edge filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Predictable circuit response is a critical prerequisite for accurate electronic measurements. Here, we describe a powerful yet straightforward experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic-impedance background-correction procedure to measure the temperature-dependent impedance (magnitude and phase) of up to ten individual passive circuit elements in a single cryostat run. We show how the model unambiguously identified a ∼20× drop in capacitance for 22 μF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with a parasitic capacitance of ∼300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to measure 10 and 22 pF thin-film capacitors and 100 MΩ thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, we showed that the simple data-acquisition method, coupled with our analysis model, enabled the measurement of component parasitics, and effectively extended the accuracy of a commercial LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies. We also showed that, in the current configuration, our simple approach is limited to a capacitance accuracy of ∼10 pF.

Carpenter, R. J. [Santa Clara Univ., Santa Clara, ↗

Excitation functions and isomeric cross-section ratios of (d,xn) reactions on 86 Sr

Excitation functions of the 86 Sr(d,n) 87m,87g Y, 86 Sr(d,2n) 86m,86g Y and 86 Sr(d,3n) 85m,85g Y reactions on enriched 86 Sr target were measured by the activation technique up to deuteron energies of 49 MeV. The isomeric cross-section ratios as a function of projectile energy were deduced from the measured data for 87m Y, 87g Y(cum), 86m Y, 86g Y(cum), 85m Y and 85g Y pairs for the same energy range. All measurements are reported for the first time. The experimental data were compared with the data from the TENDL library which is based on TALYS calculation with default parameters. No satisfactory agreement was observed. Nuclear model calculations were then performed using the codes TALYS and EMPIRE with some parameter adjustments, and compared with the experimental data. The quality of the agreement between experimental data and model calculations was numerically quantified. In general, the data as well as the isomeric cross-section ratios are partially reproduced by the model calculations, provided the input model parameters are properly chosen and the level structure of the product nucleus is thoughtfully considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metal Sulfide Ion Exchangers: High Acid Stability of Na 2 x Mg 2 y – x Sn 4– y S 8 (NMS) and Topotactic Conversion to 2D Solid Acids with Semiconducting Character

Metal sulfide ion exchange materials (MSIEs) are of interest for nuclear waste remediation applications. Here, we report the high stability of two structurally related metal sulfide ion exchange materials, Na 2x Mg 2y–x Sn 4–y S 8 (Mg-NMS) and Na 2 SnS 3 (Na-NMS), in strongly acid media, in addition to the preparation of Na 2x Ni 2y–x Sn 4–y S 8 (Ni-NMS). Their formation progress during synthesis is studied with in-situ methods, with the target phases appearing in <15 min, reaction completion in <12 h, and high yields (75–80%). Upon contact with nitric or hydrochloric acid, these materials topotactically exchange Na + for H + , proceeding in a stepwise protonation pathway for Na 5.33 Sn 2.67 S 8 . Na-NMS is stable in 2 M HNO 3 and Mg-NMS is stable in 4 M HNO 3 for up to 4 h, while both NMS materials are stable in 6 M HCl for up to 4 days. However, the treatment of Mg-NMS and Na-NMS with 2–6 M H 2 SO 4 reveals a much slower protonation process since after 4 h of contact both NMS and HMS are present in the solution. The resultant protonated materials, H 2x Mg 2y–x Sn 4–y S 8 and H 4x [(H y Na y–1 ) 1.33x Sn 4––1.33x ]S 8 , are themselves solid acids and readily react with and intercalate a variety of organic amines, where the band gap of the resultant adduct is influenced by amine choice and can be tuned within the range of 1.88(5)–2.27(5) eV. The work function energy values for all materials were extracted from photoemission yield spectroscopy in air (PYSA) measurements and range from 5.47 (2) to 5.76 (2) eV, and the relative band alignments of the materials are discussed. DFT calculations suggest that the electronic structure of Na 2 MgSn 3 S 8 and H 2 MgSn 3 S 8 makes them indirect gap semiconductors with multi-valley band edges, with carriers confined to the [MgSn 3 S 8 ] 2– layers. Light electron effective masses indicate high electron mobilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Survey of Photonuclear Measurements for 239 Pu

We have performed a limited survey of available experimental data for photonuclear cross sections on 239 Pu. In this initial survey, we excluded ratio measurements. We took inventory of a) the available measured observables and corresponding energy range of the measurements; b) the source of the irradiated photons and the methodology used for the measurement; and c) any discrepancies between the original published data and corresponding EXFOR entry. This activity is not an assessment of the quality of the data, only the availability and verifiability of the data in the EXFOR library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detecting damage in composites using volume decomposition analysis of tomographic data

Detection of damage in a single tow ceramic matrix composite specimen has been achieved using orthogonal decomposition of volumetric tomographic datasets collected at four tensile loads. This decomposition approach has been applied at two different length scales: (i) individual fibres and (ii) bulk volumes containing fibres and matrix material. Volumes were first decomposed to feature vectors, orders of magnitude smaller than the original volume they describe, and then comparisons between datasets at different load levels were made in feature vector space. The results show quantitative measurements of damage location, damage morphology and the relative growth of this damage with increased load when compared with a dataset with less or no damage. No prior knowledge of the dataset or training of algorithms is required for damage to be detected, it is only necessary that at least two datasets are available for comparison, e.g. from in situ or repeated scanning measurements. Results are generated on significantly shorter timescales when compared with previous automated approaches to tomography data processing. This approach has the potential to be applied to damage detection in a range of materials through comparisons of volumetric datasets from a range of measurement or computational techniques.

Middleton, Ceri A.↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Local self-motion of water through the Van Hove function

Here, we show that the self-part of the Van Hove Function the correlation function describing the dynamics of a single molecule of water can be determined through a high-resolution inelastic X-ray scattering experiment. The measurement of inelastic X-ray scattering up to 10 Å -1 makes it possible to convert the inelastic X-ray scattering spectra into the Van Hove function, and its self-part is extracted from the short-range correlations. The diffusivity estimated from the short-range dynamics of water molecules is different from the long-range diffusivity measured by other methods. This approach using the experimentally determined self-part of the Van Hove function will be useful to the study of the local dynamics of atoms and molecules in liquids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of inoculation with prion dilutions within the dynamic range of ELISA absorbance on prion incubation period

This study examines the effect of various infectious prion titers within the dynamic range as measured by ELISA on incubation period. We inoculated ovinized transgenic mice with seven decreasing dilutions of a fast-incubating scrapie strain. The highest inoculum group was a 20% w/v brain homogenate from a sheep with scrapie. The subsequent six inoculum dilutions ranged from the highest ELISA optical density reading of 4.000 to a dilution where scrapie prions were not detectable by ELISA. Multiple comparison analysis demonstrated variation in the incubation periods between some inoculum groups. Incubation periods were similar between inoculum groups unless their optical density differed by more than ≈2 units of absorbance. These data will inform the interpretation of future studies that compare incubation periods in experimentally inoculated animals for TSE research.

60 APPLIED LIFE SCIENCES↗

Magnetically driven short-range order can explain anomalous measurements in CrCoNi

Significance High-entropy alloys, an exciting new class of structural materials involving many concentrated elements, are generally assumed to be chemically disordered. This work reveals how magnetic interactions can drive atomic-scale ordering in a mechanically interesting system that has been widely studied as a model for many promising alloys. The formation of short-range order in this manner is used to explain experimental anomalies, suggesting that many related materials could contain similarly impactful ordering under standard conditions. This possibility offers solutions to outstanding questions concerning CrCoNi and emphasizes the importance of magnetism and short-range order in related high-entropy alloys.

36 MATERIALS SCIENCE↗

Intergranular Spin Dependent Tunneling Dominated Magnetoresistance in Helimagnetic Manganese Phosphide Thin Films

Helical magnets are emerging as a novel class of materials for spintronics and sensor applications; however, research on their charge- and spin-transport properties in a thin film form is less explored. Herein, we report the temperature and magnetic field-dependent charge transport properties of a highly crystalline MnP nanorod thin film over a wide temperature range (2 K < T < 350 K). The MnP nanorod films of ~100 nm thickness were grown on Si substrates at 500 °C using molecular beam epitaxy. The temperature-dependent resistivity ρ(T) data exhibit a metallic behavior (dρ/dT > 0) over the entire measured temperature range. However, large negative magnetoresistance (Δρ/ρ) of up to 12% is observed below ~50 K at which the system enters a stable helical (screw) magnetic state. In this temperature regime, the Δρ(H)/ρ(0) dependence also shows a magnetic field-manipulated CONE + FAN phase coexistence. The observed magnetoresistance is dominantly governed by the intergranular spin dependent tunneling mechanism. These findings pinpoint a correlation between the transport and magnetism in this helimagnetic system.

36 MATERIALS SCIENCE↗

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural, Electronic, and Thermal Properties of CdSnAs 2

Structural, electrical, and thermal properties of CdSnAs 2 , with analyses from temperature-dependent transport properties over a large temperature range, are reported. Phase-pure microcrystalline powders were synthesized that were subsequently densified to a high-density homogeneous polycrystalline specimen for this study. Temperature-dependent transport indicates n-type semiconducting behavior with a very high and nearly temperature independent mobility over the entire measured temperature range, attributed to the very small electron effective mass of this material. The Debye model was successfully applied to model the thermal conductivity and specific heat. Furthermore, this work contributes to the fundamental understanding of this material, providing further insight and allowing for investigations into altering this and related physical properties of these materials for technological applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of Distributed Temperature Sensors Using Commercially Available SMF-28 Optical Fiber From 22 °C to 1000 °C

Optical frequency domain reflectometry (OFDR) is a family of optical techniques which can be used to produce distributed temperature measurements from the spectral shift of an interference pattern based on the Rayleigh backscatter signature of an optical fiber. Adaptive signal processing techniques have recently been used with OFDR to record meaningful spectral shift data from commercially available SMF-28 optical fibers heated beyond 950 °C. Furthermore, a correlation between the measured spectral shift and temperature has not yet been developed at these high temperatures. To extend the measurable temperature range of OFDR in SMF-28, this work describes the development of such a correlation from room temperature (22 °C) to 1000 °C. The relationship between spectral shift and temperature change over this range was found to be best characterized by the fourth-order polynomial ΔT=(-4.241 * 10 -11 )S 4 + (-2.017 * 10 -7 )S 3 + (-3.677 * 10 -4 )S 2 + (-0.8057)S, where ΔT represents the temperature difference compared to the reference temperature, and S represents the spectral shift measured by the fibers. The calibration developed in this work assumes that the fiber has been fully annealed by heating the fiber to 1000 °C for a few hours. This paper is the first to demonstrate the calibration and use of SMF-28 distributed optical fiber sensors up to 1000 °C, enabled using adaptive OFDR-based signal processing.

47 OTHER INSTRUMENTATION↗

Measurement of the $K^{+} → π^{+} γγ$ decay

A sample of 3984 candidates of the $K^{+} → π^{+} γγ$ decay, with an estimated background of 291 ± 14 events, was collected by the NA62 experiment at CERN during 2017–2018. In order to describe the observed di-photon mass spectrum, the next-to-leading order contribution in chiral perturbation theory was found to be necessary. The decay branching ratio in the full kinematic range is measured to be (9.61 ± 0.17) x 10 -7 . The first search for production and prompt decay of an axion-like particle with gluon coupling in the process $K^{+} → π^{+} a$, $a → γγ$ is also reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗