Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗

The role of laser coherence in long-range vibration measurements

In this paper, the temporal coherence effect of a laser oscillator will be critically examined using existing laser frequency stability data in the time domain by first converting them to the frequency domain. We limit our discussion to CO2 lasers. To be more specific, our presentation will include the following items: (1) a review of the definitions and representations of laser oscillator frequency stability; (2) a methodology will be developed for determining the dynamic range of vibration measurements; (3) the methodology will show that the conversion of the laser frequency stability from the time domain to the frequency domain can be performed effectively in the optical region; and (4) because of a finite time delay, the phase noise is reduced for offset frequencies close to the carrier frequency.

Eng, R. S.↗

Short-arc orbit determination using coherent X-band ranging data

The use of X-band frequencies in ground-spacecraft and spacecraft-ground telecommunication links for current and future robotic interplanetary missions makes it possible to perform ranging measurements of greater accuracy than previously obtained. It is shown that ranging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. The application of high-accuracy S/X-band and X-band ranging to orbit determination with relatively short data arcs is investigated in planetary approach and encounter scenarios. Actual trajectory solutions for the Ulysses spacecraft constructed from S/X-band ranging and Doppler data are presented; error covariance calculations are used to predict the performance of X-band ranging and Doppler data. The Ulysses trajectory solutions indicate that the aim point for the spacecraft's February 1992 Jupiter encounter was predicted to a geocentric accuracy of 0.20 to 0.23/microrad. Explicit modeling of range bias parameters for each station pass is shown to largely remove systematic ground system calibration errors and transmission media effects from the Ulysses range measurements, which would otherwise corrupt the angle finding capabilities of the data. The Ulysses solutions were found to be reasonably consistent with the theoretical results, which suggest that angular accuracies of 0.08 to 0.1/microrad are achievable with X-band ranging.

Thurman, S. W.↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining Spatial Coordinates By Laser Ranging

Three range-measuring lasers arranged in triangle measure location of point. Set of three measurements of distances (ranges) of retroreflector on object from three rangefinders provides sufficient information to calculate coordinates of retroreflector in coordinate system defined by rangefinders. If at least three noncollinear retroreflectors attached to object, orientation of object also determined. Potential applications include observation and control of large structures, robotics, and machine vision.

Schumacher, Larry L.↗

Applied general relativity

Important relativistic effects and issues are discussed which must be considered in the interpretation of current measurements such as ranging measurements to LAGEOS and to the moon, in the implementation of the Global Positioning System, in the synchronization of clocks near the earth's surface, and in the adoption of appropriate scales of time and length for the communication of scientific results.

Ashby, Neil↗

Pulse spreading and range correction analysis for satellite laser ranging

The pulse spreading resulting from light detection and ranging measurements of the range to earth-orbiting satellites is described. An analysis quantifying this pulse spreading and the calculation of corrections to be applied to the lidar range determination of satellites is detailed.

Schwartz, Jon A.↗

A Long-Range Precision Ranging System

A technique is presented that may be used for precision real-time continuous range measuring at long ranges. The technique uses a carrier that is phase modulated by a pseudo-random binary sequence. The characteristics of the sequence that make it acquirable are discussed. The general form of a receiver capable of tracking the carrier is given and is shown to be a kind of phase-locked loop. A two-loop system capable of tracking a pseudo-random sequence and its clock is given. The combination of the receiver and the sequence tracking system form a ranging receiver. The power division necessary between the carrier and the sidebands is shown to be determined by the noise bandwidths of the two tracking systems. The bandwidths necessary for tracking space probes and Earth satellites are given and some experiments in radar-tracking Earth satellites are described. Based on these experiments, estimates are made of the useful range of such a system in tracking space probes.

Easterling, Mahlon↗

Laser pulse analysis

Methods are presented for locating threshold points by using laser pulse analysis. It was found that there are errors involved in the determination of each of these quantities, and an attempt was made to separate their effects on the overall range correction. Several series of corrected range measurements for fixed reflectors and satellites were obtained. Residuals were computed by fitting the range measurements to either fixed-reflector distances or short arcs of satellite orbits. Root mean square values of these residuals are presented.

Lehr, C. G.↗

Modeling methodology for MLS range navigation system errors using flight test data

Flight test data was used to develop a methodology for modeling MLS range navigation system errors. The data used corresponded to the constant velocity and glideslope approach segment of a helicopter landing trajectory. The MLS range measurement was assumed to consist of low frequency and random high frequency components. The random high frequency component was extracted from the MLS range measurements. This was done by appropriate filtering of the range residual generated from a linearization of the range profile for the final approach segment. This range navigation system error was then modeled as an autoregressive moving average (ARMA) process. Maximum likelihood techniques were used to identify the parameters of the ARMA process.

Karmali, M. S.↗

Characterization of a selective, zero power sensor for distributed sensing of hydrogen in energy applications

The use of hydrogen as a clean and renewable energy source is increasing rapidly for both vehicle and stationary applications. There are safety concerns for the locations in which hydrogen is made, used, and transported (i.e., pipelines and tanker trucks). Sensors are needed to comply with safety regulations and to enable a smooth and safe rollout of hydrogen as an alternative energy. However, hydrogen sensors do not yet exist that have the combined features of small size and low power for easy deployment coupled with high-volume manufacturability and low cost. This is necessary to accommodate the emerging fixed and mobile markets while retaining critical metrological metrics, including measurement range, detection limits, selectivity, fast response, stability, and long lifetime. An amperometric gas sensor for hydrogen (AGS) has been developed using an innovative manufacturing method. The sensor was designed using scalable fabrication strategies based on “Printed Electronics” (PE) methodology which are compatible with large-scale production. Prototype sensors were batch fabricated with multiple individual elements on a substrate compatible in size with a standard 8-inch wafer to enable high-volume, low-cost manufacturing, thereby leveraging PE and semiconductor fabrication infrastructure. This novel AGS was instrumented with control circuitry and evaluated for hydrogen detection in the range of 0–5000 ppmv H2 in air. Specific performance evaluations included assessment of the sensor measurement range, repeatability, and selectivity.

08 HYDROGEN↗

Measurements of dynamic surface changes by digital holography for in situ plasma erosion applications

There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO 2 laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode’s synthetic wavelength allows the measurable range to be expanded by a factor of ~400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ~50 nm to ~4 μm in single laser mode and up to ~400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.

Smith, Cary↗

Tests of gravity Using Lunar Laser Ranging

Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the pa~t four decades. The three retrorefiector arrays put on the Moon by the Apollo astronauts and the French built array on the second Soviet Lunokhod rover continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point :3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly. it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retrorefiectors are limiting the precision of the range measurements. In this article. we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.

Merkowitz, Stephen M.↗

Application of high-precision two-way ranging to Galileo Earth-1 encounter navigation

The application of precision two-way ranging to orbit determination with relatively short data arcs is investigated for the Galileo spacecraft's approach to its first Earth encounter (December 8, 1990). Analysis of previous S-band (2.3-GHz) ranging data acquired from Galileo indicated that under good signal conditions submeter precision and 10-m ranging accuracy were achieved. It is shown that ranging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. A range data filtering technique, in which explicit modeling of range measurement bias parameters for each station pass is utilized, is shown to largely remove the systematic ground system calibration errors and transmission media effects from the Galileo range measurements, which would otherwise corrupt the angle-finding capabilities of the data. The accuracy of the Galileo orbit solutions obtained with S-band Doppler and precision ranging were found to be consistent with simple theoretical calculations, which predicted that angular accuracies of 0.26-0.34 microrad were achievable. In addition, the navigation accuracy achieved with precision ranging was marginally better than that obtained using delta-differenced one-way range (delta DOR), the principal data type that was previously used to obtain spacecraft angular position measurements operationally.

Pollmeier, V. M.↗

Short Range Correlation measurements in the quasielastic region with an 11 GeV beam

Electron scattering is a powerful tool for studying high momentum nucleon and quark distributions in nuclei. Thomas Jefferson National Accelerator Facility (JLab) with its 11 GeV beam is capable of studying high momentum nucleons with unmatched precision. The role of short range nucleon configurations and quark distributions is significant for understanding the dynamics of nuclei and their underlying components. Scattering cross section measurements in the kinematic regime x > 1, a region forbidden to the free nucleon, are sensitive to high momentum nucleons, which are believed to come from short range correlations (SRCs). SRCs are strongly interacting, high momentum nucleons with a low center-of-mass momentum that are highly decoupled from the nuclear environment. The focus of this research is on precision measurements of 2N SRCs, the observation of 3N SRCs, and the measurement of parton distribution functions at x > 1

Morean, Casey↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Seasonal Variations of the Earth's Gravitational Field: An Analysis of Atmospheric Pressure, Ocean Tidal, and Surface Water Excitation

Seasonal variations in the Earth's gravitational field are investigated through the analysis of LAGEOS I satellite laser ranging measurements spanning 1984 to 1992. Global surface pressure data are analyzed; a self-consistent equilibrium ocean tide model is used to compute the effect of the gravitational field on tides. Laser ranging measurements are used to model gravitational field effects.

Laser↗

Lidar Remote Sensing of Forests: New Instruments and Modeling Capabilities

Lidar instruments provide scientists with the unique opportunity to characterize the 3D structure of forest ecosystems. This information allows us to estimate properties such as wood volume, biomass density, stocking density, canopy cover, and leaf area. Structural information also can be used as drivers for photosynthesis and ecosystem demography models to predict forest growth and carbon sequestration. All lidars use time-in-flight measurements to compute accurate ranging measurements; however, there is a wide range of instruments and data types that are currently available, and instrument technology continues to advance at a rapid pace. This seminar will present new technologies that are in use and under development at NASA for airborne and space-based missions. Opportunities for instrument and data fusion will also be discussed, as Dr. Cook is the PI for G-LiHT, Goddard's LiDAR, Hyperspectral, and Thermal airborne imager. Lastly, this talk will introduce radiative transfer models that can simulate interactions between laser light and forest canopies. Developing modeling capabilities is important for providing continuity between observations made with different lidars, and to assist the design of new instruments. Dr. Bruce Cook is a research scientist in NASA's Biospheric Sciences Laboratory at Goddard Space Flight Center, and has more than 25 years of experience conducting research on ecosystem processes, soil biogeochemistry, and exchange of carbon, water vapor and energy between the terrestrial biosphere and atmosphere. His research interests include the combined use of lidar, hyperspectral, and thermal data for characterizing ecosystem form and function. He is Deputy Project Scientist for the Landsat Data Continuity Mission (LDCM); Project Manager for NASA s Carbon Monitoring System (CMS) pilot project for local-scale forest biomass; and PI of Goddard's LiDAR, Hyperspectral, and Thermal (G-LiHT) airborne imager.

Cook, Bruce D.↗